• 제목/요약/키워드: 3D PD

검색결과 305건 처리시간 0.023초

Evaluation of the marginal and internal fit of a single crown fabricated based on a three-dimensional printed model

  • Jang, Yeon;Sim, Ji-Young;Park, Jong-Kyoung;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권5호
    • /
    • pp.367-373
    • /
    • 2018
  • PURPOSE. To evaluate the fit of a crown produced based on a 3D printed model and to investigate its clinical applicability. MATERIALS AND METHODS. A master die was fabricated with epoxy. Stone dies were fabricated from conventional impressions (Conventional stone die group: CS, n=10). Digital virtual dies were fabricated by making digital impressions (Digital Virtual die group: VD, n=10). 3D data obtained from the digital impression was used to fabricate 3D printed models (DLP die group: DD, n=10, PolyJet die group: PD, n=10). A total of 40 crowns were fabricated with a milling machine, based on CS, VD, DD and PD. The inner surface of all crowns was superimposed with the master die files by the "Best-fit alignment" method using the analysis software. One-way and 2-way ANOVA were performed to identify significant differences among the groups and areas and their interactive effects (${\alpha}=.05$). Tukey's HSD was used for post-hoc analysis. RESULTS. One-way ANOVA results revealed a significantly higher RMS value in the 3D printed models (DD and PD) than in the CS and DV. The RMS values of PD were the largest among the four groups. Statistically significant differences among groups (P<.001) and between areas (P<.001) were further revealed by 2-way ANOVA. CONCLUSION. Although the fit of crowns fabricated based on the 3D printed models (DD and PD) was inferior to that of crowns prepared with CS and DV, the values of all four groups were within the clinically acceptable range (<$120{\mu}m$).

AE Sensor를 적용한 C-GIS내의 PD 특성 (PD Characteristics in C-GIS Using AE Sensor)

  • 이용희;신양섭;장수형;서정민;이용희;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1652-1654
    • /
    • 2002
  • The defects making partial discharge(PD) in a C-GIS(Cubicle Insulated Switchgear) initiate acoustic wave which can be detected using acoustic emission sensor placed outside or inside the C-GIS enclosure. In this paper, partial discharge property for 2 locations for AE sensor and 3 locations for defects in C-GIS are presented and PD waveforms were analyzed by PRPDA(Partial Resolved Partial Discharge Analysis). As a result, using post amplifier having gain of 10,000 and band pass filter having $20kHz{\sim}300kHz$, resolution of waveforms AE sensor signal by detected was good. Noise level was about 80 mV.

  • PDF

고성능 광각 3차원 스캐닝 라이다를 위한 스터드 기술 기반의 대면적 고속 단일 광 검출기 (Large-area High-speed Single Photodetector Based on the Static Unitary Detector Technique for High-performance Wide-field-of-view 3D Scanning LiDAR)

  • 한문현;민봉기
    • 한국광학회지
    • /
    • 제34권4호
    • /
    • pp.139-150
    • /
    • 2023
  • 다양한 구조의 라이다(light detection and ranging, LiDAR)가 존재함에도 불구하고 넓은 화각을 유지하면서 장거리 측정과 수직, 수평 방향 모두에서 높은 해상도를 만족하는 LiDAR를 구현하는 것은 매우 어렵다. 스캐닝 구조는 장거리 탐지 및 수직, 수평 방향에 대한 높은 해상도를 만족하는 고성능 LiDAR를 구현하는 데 유리하지만, 넓은 화각을 확보하기 위해서는 검출 속도에 불리한 대면적 광 검출기(photodetector, PD)가 필수적이다. 따라서 이러한 문제점을 해결하기 위해 다수의 소면적 PD를 고속의 단일 대면적 PD로 작동할 수 있는 static unitary detector(STUD) 기술 기반의 PD를 제안하였다. 본 논문에서 제안하는 InP/InGaAs STUD PIN-PD는 1,256 ㎛×19 ㎛의 단위 면적을 가지는 32개 소면적 PD를 활용하여 1,256 ㎛×949 ㎛ 이내에서 다양한 형태로 설계 및 제작하였다. 이후 다양한 형태로 제작된 STUD PD의 특성과 감도는 물론 이를 활용한 LiDAR 수신 보드의 잡음 및 신호 특성에 대해 측정 및 분석하였다. 마지막으로 STUD PD가 적용된 LiDAR 수신 보드를 1.5-㎛ master oscillator power amplifier 레이저를 광원으로 활용하는 3차원 스캐닝 LiDAR 시제품에 적용하였고, 이를 통해 대각 32.6도의 광각에서 50 m 이상의 장거리 물체를 정밀하게 탐지하면서 320 px×240 px의 고해상도 3차원 영상을 동시에 확보하였다.

이부프로펜에 의해 유발된 급성 위궤양에 있어 Platycodin D의 보호효과 (Protective Effect of Platycodin D in the Acute Gastric Ulcer Induced by Ibuprofen in Rats)

  • 유리;신원호;김솔;손규희;곽동미;김상룡;류시윤;박상준
    • 한국임상수의학회지
    • /
    • 제30권1호
    • /
    • pp.5-11
    • /
    • 2013
  • 급성 위궤양은 위점막에서 세포증식과 세포사멸의 불균형으로 발병되어진다. 현재 Platycodin D (PD)는 항산화 및 항염증 등의 다양한 약리효능을 가진다고 보고되고 있다. 본 실험은 ibuprofen에 의해 유발된 급성 위궤양이 전처치한 PD에 의해 위궤양 보호효과를 가지는 가를 알아보기 위해 실시하였다. PD의 효능은 위점막에서의 COX-2의 발현과 더불어 위점막상피세포의 증생과 세포사멸정도에 의해서 평가하였다. 실험군은 정상대조군, ibuprofen 유발 위궤양군, 2.5 mg/kg PD 전처치군, 5 mg/kg PD 전처치군으로 분류하였다. 급성위궤양은 200 mg/kg의 ibuprofen을 하루에 3번 8시간 간격으로 경구 투여하여 유발하였다. PD는 5일간 경구로 하루에 한 번씩 전처치하였다. PD의 전처치가 ibuprofen에 의해 유발된 위궤양 병변을 유의적으로 감소시켰으며 과도한 위점액 분비로 인한 점액질의 소실을 억제하였다. 또한 PD 전처치가 위점막의 상피세포증식층에서 Ki-67 양성세포의 감소 및 세포사멸을 억제하였다. 추가적으로 PD의 전처치가 위궤양에 의해 증가된 COX-2 발현을 감소시켰다. 이상의 연구결과는 PD의 전처치가 ibuprofen에 의해 유발된 위점막손상에 있어 COX-2의 발현조절을 통하여 위점막세포의 증식과 사멸에 관여할 것으로 보여진다.

Application of Neural Network and 3D Pattern Matching in Partial Discharge Signal

  • Lim Jang-seob;Park Young-sik;Kim Cheol-su
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.361-364
    • /
    • 1996
  • Aging diagnosis system using partial discharge(PD) is being highlighted as a research area. But the application of PD requires complicated analysis method because the PD has complex progressing forms. In this paper, It has been developed to the PD diagnosis system using neural network(NN). As a result after NN learning, the recognized rate was represented about 85%. The safety area is possible to express the second output of NN in this experiments.

  • PDF

알콜리즘 환자(患者)의 인격특성(人格特性)에 관(關)한 임상적(臨床的) 고찰(考察) -MMPI와 사상체질(四象體質)을 중심(中心)으로- (Clinical Study on Personality Characteristics of the Alcoholic Patients -with MMPI & Sasang Constitution(四象體質)-)

  • 김종우;김지혁;황의완
    • 동의신경정신과학회지
    • /
    • 제3권2호
    • /
    • pp.65-85
    • /
    • 1992
  • To study the personality characteristics of alcoholic patients, they were screned with the MAST(Michigan Alcoholism Screening Test) and administered with the MMPI (Minnesota Multiphasic Personality Inventory) in the Dept. of Neuropsychiatry, Oriental Medical Hospital in Kyung Hee Univ. form March 1991 to June 1991. Patients admitted for alcoholism were examined and analyzed using the above tests and then studied by Sasang Constitutional approach. Results were as follows; 1. In the MAST score, the cases of obvious alcohol dependence was 53.3% and overall mean score was 28.1 point. 2. In the MMPI scale, the mean of the T-scores for 2(D)-4(Pd) profile was high, but it was not statistically significant. 3. The results obtained by multivariate cluster analysis of MMPI T-scores can be divided into 3 subgroups; 1) 9% showed the psychiatric tendency of F-6(Pa)-9(Ma)profile, 2) 44.2% showed no significant profile, 3)46.5% showed the neurotic tendency of 1(Hs)-2(D)-3(Hy)-4(Pd) profile. 4. Since 44.2% showed no significant profile on the MMPI, much more alcoholic patients were caused not by personality factors but by social tolerance, and also by increasing apportunities of drinking in Korean society. 5. When analyzed with Sasang Constituional approach, 1) for the Soyangin (少陽人): 6(Pa) scale was particularly high, 1(Hs) and 3(Hy) scales were low compared to others, 2) for the Taiumin(太陰人): 1(Hs)-2(D)-3(Hy)-4(Pd) neurotic profile was high, the K-scale and 4(Pd)scale were high compared to the Soyangin, 3) for the Soumin(少陰人): 1(Hs)-2(D)-3(Hy)-4(Pd) neurotic profile and 7(Pt) scale were also high.

  • PDF

이소옥사졸과 그의 유도체들이 배위된 팔라듐(Ⅱ)과 백금(Ⅱ) 착물의 항암활성에 관한 이론적 연구 (Theoretical Study on Antitumor Activity of Palladium(II) and Platinum(II) Complexes with Isoxazole and Its Derivatives)

  • 김정성;송영대
    • 대한화학회지
    • /
    • 제42권4호
    • /
    • pp.369-377
    • /
    • 1998
  • 이소옥사졸과 그의 유도체가 배위된 팔라듐(II) 및 백금(II)착물$([M(L)_2X_2]$, M=Pd(II), Pt(II); L=isoxazole(isox), 3,5-dimethylisoxazole(3,5-diMeisox), 3-methyl, 5-phenylisoxazole(3-Me, 5-Phisox), and 4-am-ino 3,5-dimethylisoxazole(4-ADI); X=Cl, Br)의 항암활성을 분자역학(MM2)법으로 최소에너지를 갖는 구조를 구한 후 확장분자궤도함수(EHMO)법으로 조사하였다. 중심금속의 $d_x^{2-}_y^2$ 궤도함수와 할로겐 원자의 $p_x$ 궤도함수 사이의 ${\sigma}MO$ 에너지준위$(E_{{\sigma}(Pd,Pt-X)})$가 질소원자의 $p_x$ 궤도함수 사이의 ${\sigma}MO$ 에너지준위 $(E_{\sigma}(Pd,Pt-N))$보다 예외없이 더 높아서 결합이 약함을 알 수 있었다. 아울러 같은 착물에서 cis- 보다 trans-착물에서 $(E_{\sigma}(Pd,Pt-X))$ 값이 더 높아서 결합이 약함을 알았다. 또한 평면형 리간드가 배위될 경우 cis-, trans- 이성체 모두 백금착물에서보다 팔라듐착물에서 $X^-$ 이온의 이탈이 더 용이했다. 다라서 $X^-$ 이온으로 떨어져 나가는 용이성이 항암활성과 어떤 관계가 있을 것으로 생각하고 $E_{{\sigma}(Pd,Pt-N)}-E_{{\sigma}(Pd,Pt-X)}({\Delta}E_{{\sigma}(N-X)})$과 저해활성 계수인 logIA의 값를 도시하였던바 실험치와 상관 계수가 0.96인 좋은 직선성이 성립함을 알 수 있었다.

  • PDF

절연계의 결함별 부분방전 패턴분석 (Analysis of PD Patterns Depending on Defect Types in Insulation System)

  • 박찬용;김황국;김성욱;지홍근;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.912-918
    • /
    • 2009
  • In this paper, we carried out a comparative analysis of partial discharge(PD) patterns caused by deterioration of cast-resin and oil insulation systems. Various electrode systems were fabricated such as needle-needle, needle-plane and plane-plane to simulate defects that may exist in the insulation system of transformers. A low-noise amplifier which has a gain of 40 dB and a frequency bandwidth of 500 kHz $\sim$ 30 MHz (-3 dB) was designed to detect small PD signals. From the analysis of acquired PD signals, we could find that a unique PD pattern is formed according to types of defect. These data will be applied usefully to diagnose insulation condition of transformers.

  • PDF

파킨슨병 환자의 골밀도 영향요인 (Factors Affecting Bone Mineral Density of the Femur in Parkinson's Disease Patients)

  • 김상희;이은남;박은영;김재우
    • 근관절건강학회지
    • /
    • 제19권3호
    • /
    • pp.350-361
    • /
    • 2012
  • Purpose: The purpose of this study is to explore the level of bone mineral densities of the femur neck and to identify factors affecting bone mineral density of the femur in Parkinson's disease (PD) patients. Methods: Participants were 121 PD patients visiting the outpatient clinic of D University Hospital in B City. Bone mineral density was measured at the femur neck by using a dual-energy x-ray absorptiometry. The serum vitamin D level, the amounts of milk intake, caffeine intake, cigaret smoking, and alcohol consumption, and the number of steps taken daily were measured. Past and present disease history, the medication history, and duration of the disease were also collected. The level of disability was obtained by neurologists using the Hoehn and Yahr stage and the Unified Parkinson's Disease Rating Scale. Results: Among PD patients, 57% had osteopenia and 15.7% had osteoporosis. The bone mineral density of the femur was associated with weight, serum vitamin D level, age, and working status. Conclusion: The identification of weight and serum vitamin D level as important predictive factors emphasizes the importance of balanced nutrition for PD patients.

Effects of Sputtering Parameters on the Properties of Co/Pd Multilayered Films

  • Shin, J. N.;Hong, D. H.;Lee, T. D.
    • Journal of Magnetics
    • /
    • 제8권4호
    • /
    • pp.146-148
    • /
    • 2003
  • Multilayered films of Co/Pd have been studied as a candidate material for a high density perpendicular recording medium due to higher anisotropy energy. However, high exchange coupling among grains results in large transition noise. To reduce the exchange coupling and grain size, addition of 3rd elements and physical separation of grains have been attempted. In the present paper, effects of sputtering pressure, Co sublayer thickness and Pd underlayer thickness on magnetic properties and microstructures were studied. It was found that by increasing sputtering pressure from 5 mTorr to 25 mTorr, Ms decreased to one half and coercivity increased more than 5000 Oe. The increase of the coercivity is associated with physical separation of grains by high pressure sputtering. Ms per volume of Co for Co/Pd multilayered film deposited at 25 mTorr shows continuous decrease with increasing Co sublayer thickness. This was related to void formation and intermixing of Co/Pd interface. Also, effect of Pd underlayer thickness on magnetic properties will be discussed.