• 제목/요약/키워드: 3D Measuring System

검색결과 541건 처리시간 0.038초

3차원 레이저스캐너의 거리측정 정밀도 향상을 위한 시스템의 구조분석과 신호처리 (Structure analysis and signal process to improve distance measuring accuracy of 3D laser scanner)

  • 오동근;유현국;김호섭
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2010년 춘계학술발표회 논문집
    • /
    • pp.245-247
    • /
    • 2010
  • This research presents both system structure analysis to improve performance of 3D laser scanner, which has time of flight method, and scheme to minimize distance measurement errors during signal process. With the help of reference source, we minimized the instability of electronic signal processing time and possibility of distance measurement errors. Furthermore, it helps easy alignment and accuracy of system by using fiber delay line and coupler.

  • PDF

3차원 정보가 반영된 브래지어 패턴 설계 -Ruled surface의 활용- (Brassiere Pattern Design Using the 3D Information - Application of Ruled Surface-)

  • 이예진;홍경희
    • 한국의류학회지
    • /
    • 제28권11호
    • /
    • pp.1536-1543
    • /
    • 2004
  • Garment is made by a 2D pattern and should be fitted to a human body which has 3D characteristics. Therefore, to design a pattern more effectively, the use of 3D information of a human body and the investigation of relationship between the 3D garment and 2D pattern are necessary. In this work, ruled surface method was used to reflect the 3D information of a human body for a pattern design. The images of the brassiere line on the woman's dress form were captured by phase-shifting projection moire system and the 3D information on the design line was obtained. 2D patterns on the various parts of the brassiere were developed directly from the 3D data by the ruled surface method. In addition, design line, the area and the amount of dart were quantified. And then we verify the appropriateness of the ruled surface method to the 2D pattern development by measuring the distribution of the space between women's figure and segmented clothing item. It was found that the ruled surface method is useful to transform the 3D design line to the 2D pattern, if we followed the steps suggested in this paper.

중소기업성장지원 OLAP 데이터베이스 시스템 구축 -중소기업기술개발지원사업을 중심으로- (Development of an OLAP Database System for SME Growth Support -Centering around the Small Business R&D Support Project-)

  • 황만모;최인수
    • 한국컴퓨터정보학회논문지
    • /
    • 제17권1호
    • /
    • pp.235-245
    • /
    • 2012
  • 본 연구에서는 중소기업성장을 지원할 OLAP 데이터베이스 시스템을 구축하는 것을 목적으로 하고 있다. 본 연구의 특징은 중소기업의 크기를 측정할 모델을 작성하는 것이다. 이 모델은 고용인력, 매출액, 수출액, 기술보유, 매출액 대비 기술개발투자비 비율 등의 5가지 기업크기 측정지표로 구성된다. 또한 단계적 기술개발자금 지원을 가능케 할 FREQUENCY 차원 테이블을 설계하는 것이다. FREQUENCY 차원을 포함한 3개 차원과 기업크기 측정모델을 사용하여 OLAP 데이터베이스 시스템을 구축한 것이다. 그리고 이 OLAP 데이터베이스 시스템을 이용하여 기 시행된 중소기업기술개발지원사업의 적정성을 평가해 보고 있다.

Measurement of 3-D range-image of object diagnolly moving against semiconductor laser light beam

  • Shinohara, Shigenobu;Ichioka, Yoshiyuki;Ikeda, Hiroaki;Yoshida, Hirofumi;Sumi, Masao
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.299-302
    • /
    • 1995
  • Recently, we proposed a 3-D range-image measuring system for a slowly moving object by mechanically scanning a laser light beam emitted from a self mixing laser diode. In this paper, we introduced that every object moves along a straight line course, which is set diagonally against the semiconductor laser beam so that we can recognize each shape and size parameters of objects separately from the acquired 3-D range-image. We measured a square mesa on a square plane as an object. The measured velocity was 4.44mm/s and 4.63mm/s with an error of 0.56mm/s to 0.37mm/s. And thickness error of the mesa was 0.5mm to 0.6mm, which was obtained from the 3-D range-image of the standstill or moving object with thickness of 17.Omm.

  • PDF

3-D Surface Profile Measurement Using An Acousto-optic Tunable Filter Based Spectral Phase Shifting Technique

  • Kim, Dae-Suk;Cho, Yong-Jai
    • Journal of the Optical Society of Korea
    • /
    • 제12권4호
    • /
    • pp.281-287
    • /
    • 2008
  • An acousto-optic tunable filter based 3-D micro surface profile measurement using an equally spaced 5 spectral phase shifting is described. The 5-bucket spectral phase shifting method is compared with a Fourier-transform method in the spectral domain. It can provide a fast measurement capability while maintaining high accuracy since it needs only 5 pieces of spectrally phase shifted imaging data and a simple calculation in comparison with the Fourier transform method that requires full wavelength scanning data and relatively complicated computation. The 3-D profile data of micro objects can be obtained in a few seconds with an accuracy of ${\sim}10nm$. The 3-D profile method also has an inherent benefit in terms of being speckle-free in measuring diffuse micro objects by employing an incoherent light source. Those simplicity and practical applicability is expected to have diverse applications in 3-D micro profilometry such as semiconductors and micro-biology.

정밀 삼차원 측정을 위한 백색광 간섭 광학 프로브 개발 (Optical Probe of white Light Interferometry for Precision Coordinate Metrology)

  • 김승우;진종한;강민구
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.195-198
    • /
    • 2002
  • Demand for high precision measurement of large area is increasing in many industrial fields. White-light Scanning Interferometer(WSI) is a well-known method for 3D profile measurement. However WSI has some limitations in a measurement range because of the sensing mechanism. Therefore, in this paper we use a heterodyne laser interferometer to get over the limitations of a short measurement range in WSI, We suggest a new WSI system combined with heterodyne laser interferometer. This system is aimed at eliminating Abbe error with measuring the focus point directly. With the use of triggering functionality of WSI, we can use this system as a probe of a precision stage such as a probe of CMM. The suggested system gives a repeatability of 87 nm in the absolute distance measurement test under the laboratory environment.

  • PDF

제연구역 출입문의 차압 및 개방력 측정기준의 실효성 분석에 관한 연구 (Study on the Analysis of Differential Pressure of the Access Door for a Smoke Control Zone and the Effectiveness of the Measurement Criteria of its Opening Force)

  • 이재오;최충석
    • 한국화재소방학회논문지
    • /
    • 제26권4호
    • /
    • pp.24-30
    • /
    • 2012
  • 본 연구에서는 화재실과 인접부 제연구역의 차압 및 방화문의 개방력을 측정할 때의 문제점을 분석하고, 객관적인 방법에 의해 측정된 실측값을 제시하는데 있다. NFSC 501A의 제연설비 가동 시 출입문의 개방에 필요한 힘은 110 N 이하로 규정하고 있다. 제연설비가 설치된 공간에서 제연설비가 작동하지 않을 때는 KS F 2805의 시험방법에 의해서 개방력의 측정이 가능하지만 제연설비가 작동되었을 때는 화재실과 제연실의 차압에 의해 발생되는 추가적인 힘이 필요하므로 기준에서 제시하는 시험방법은 신뢰성이 부족함을 알 수 있다. 제연설비 가동 전 완전히 폐쇄된 상태의 개방력은 아날로그측정기($F_a$) 27.8 N, 디지털측정기($F_d$) 27.4 N을 각각 나타냈다. 그리고 문이 $5^{\circ}$ 개방된 상태의 개방력 $F_a$는 33 N, $F_d$는 33.6 N을 나타냈다. 제연설비가 작동되고 완전히 폐쇄된 상태의 개방력 $F_a$는 45.3 N, $F_d$는 46.9 N을 나타냈고, 문이 $5^{\circ}$ 개방된 상태의 개방력 $F_a$는 77.6 N, $F_d$는 76.0 N 등으로 확인되었다. 따라서 현재의 KS F 2805에서 제시하고 있는 기준과 상이하므로 적절한 기준의 검토가 요구된다.

RDS(Robotic Drilling System)용 TCP 정밀계측을 위한 iGPS 3D Probe 개발에 관한 연구 (A Study on the Development of iGPS 3D Probe for RDS for the Precision Measurement of TCP)

  • 김태화;문성호;강성호;권순재
    • 한국기계가공학회지
    • /
    • 제11권6호
    • /
    • pp.130-138
    • /
    • 2012
  • There are increasing demands from the industry for intelligent robot-calibration solutions, which can be tightly integrated to the manufacturing process. A proposed solution can simplify conventional robot-calibration and teaching methods without tedious procedures and lengthy training time. iGPS(Indoor GPS) system is a laser based real-time dynamic tracking/measurement system. The key element is acquiring and reporting three-dimensional(3D) information, which can be accomplished as an integrated system or as manual contact based measurements by a user. A 3D probe is introduced as the user holds the probe in his hand and moves the probe tip over the object. The X, Y, and Z coordinates of the probe tip are measured in real-time with high accuracy. In this paper, a new approach of robot-calibration and teaching system is introduced by implementing a 3D measurement system for measuring and tracking an object with motions in up to six degrees of freedom. The general concept and kinematics of the metrology system as well as the derivations of an error budget for the general device are described. Several experimental results of geometry and its related error identification for an easy compensation / teaching method on an industrial robot will also be included.

Measurement Data Comparison of Fast SAR Measurement System by Probe Arrays with Robot Scanning SAR Measurement System

  • Kim, Jun Hee;Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • 제14권4호
    • /
    • pp.336-341
    • /
    • 2014
  • Dosimetry of radiating electromagnetic wave from mobile devices to human body has been evaluated by measuring Specific Absorption Rate (SAR). Usual SAR measurement system scans the volume by robot arm to evaluate RF power absorption to human body from wireless devices. It is possible to fast estimate the volume SAR by software deleting robot moving time with the 2D surface SAR data acquired by arrayed probes. This paper shows the principle of fast SAR measurement and the measured data comparison between the fast SAR system and the robot scanning system. Data of the fast SAR is well corresponding with data of robot scanning SAR within ${\pm}3$ dB, and its dynamic range covers from 10 mW/kg to 30 W/kg with 4.8 mm probe diameter.

Application of 3-D Scanner to Analysis of Functional Instability of the Ankle

  • Han, Cheng-Chun;Kubo, Masakazu;Matsusaka, Nobuou;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1971-1975
    • /
    • 2003
  • This paper describes a technique, which analyzes the functional instability of the ankle using three-dimensional scanner. The technique is based on the structured light pattern projection method, which is performed by using one digital still camera and one LCD projector. This system can be easily realized with the low cost. The measuring result has high accuracy. The measuring error is about 0.2 mm or less. Using this technique the three-dimensional posture of the leg and foot of the target person are measured and analyzed.

  • PDF