• Title/Summary/Keyword: 3D MOTION ANALYSIS

Search Result 743, Processing Time 0.03 seconds

Analysis of Lumbar Spine Load during Golf Swing in Pro. Golfer

  • Park, Sung-Kyu;Cho, Woong;An, Ho-Jung
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.1 no.2
    • /
    • pp.162-168
    • /
    • 2010
  • Low back pain is a common phenomenon among the golfers. In an attempt to understand low back pain, the kinematic changes and golf swing motion analysis has been performed to focus on lumbar spine in pro. golfers. According to the swing pattern, significant variations of the lumbar joint forces and loads has related with muscles activities so the motion analysis of lumbar spine were discussed. The purpose of this study was to analyze motion of lumbar spine and it was to compare joint force during golf swing in pro. golfers. The swing motion of the subjects was tracked using a 3D motion analysis system by Motion Analysis Ltd. and SIMM software. The angle changes of lumbar spine rapidly in vx direction during the top back swing and the finish and in vy direction during the follow through and in vz direction during the down swing and the impact(Subject A). The angle changes of lumbar spine rapidly in vx direction during the top back swing and in vy direction during the down swing, the impact and the follow through and in vz direction during the down swing(Subject B). In conclusion, subject A and B both show sudden angle changes between 1st-3rd lumbar spine and 4th-5th lumbar spine during the stage from address to top back swing which caused by over upper body twisting.

  • PDF

Motion Behavior of Platform Supply Vessels Running Under Regular Wave Conditions in RANS Model

  • Park, Huiseung;Jang, Hoyun;Ahn, Namhyun;Yoon, Hyunsik
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.3
    • /
    • pp.366-372
    • /
    • 2019
  • This study performed a numerical analysis of a 3D unsteady viscous flow in order to investigate ship motion responses running through regular waves of the platform supply vessel. The feasibility of numerical analysis was tested under the three regular wave conditions of the KRISO container ship (KCS) suggested at the 2010 Gothenburg CFD Workshop. The resulting resistance coefficient, heave motion, and pitch angle were compared with the model test of the harmonic analysis. Also, the ship motion response characteristics of the platform supply vessel were performed using the proven method of the KRISO container ship (KCS). The ship motions including the resistance coefficient, heave motion, and pitch angle according to the time series were investigated via harmonic analysis under regular waves condition of ${\lambda}/LPP=1.87$ and $H_S=0.078m$.

A Study on Performance Improvement of Target Motion Analysis using Target Elevation Tracking and Fusion in Conformal Array Sonar (컨포멀 소나에서의 표적고각 추적 및 융합을 이용한 표적기동분석 성능향상 연구)

  • Lee, HaeHo;Park, GyuTae;Shin, KeeCheol;Cho, SungIl
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.320-331
    • /
    • 2019
  • In this paper, we propose a method of TMA(Target Motion Analysis) performance improvement using target elevation tracking and fusion in conformal array sonar. One of the most important characteristics of conformal array sonar is to detect a target elevation by a vertical beam. It is possible to get a target range to maximize advantages of the proposed TMA technology using this characteristic. And the proposed techniques include target tracking, target fusion, calculation of target range by multipath as well as TMA. A simulation study demonstrates the outstanding performance of proposed techniques.

3D Object's shape and motion recovery using stereo image and Paraperspective Camera Model (스테레오 영상과 준원근 카메라 모델을 이용한 객체의 3차원 형태 및 움직임 복원)

  • Kim, Sang-Hoon
    • The KIPS Transactions:PartB
    • /
    • v.10B no.2
    • /
    • pp.135-142
    • /
    • 2003
  • Robust extraction of 3D object's features, shape and global motion information from 2D image sequence is described. The object's 21 feature points on the pyramid type synthetic object are extracted automatically using color transform technique. The extracted features are used to recover the 3D shape and global motion of the object using stereo paraperspective camera model and sequential SVD(Singuiar Value Decomposition) factorization method. An inherent error of depth recovery due to the paraperspective camera model was removed by using the stereo image analysis. A 30 synthetic object with 21 features reflecting various position was designed and tested to show the performance of proposed algorithm by comparing the recovered shape and motion data with the measured values.

Feasibility Study of Gait Recognition Using Points in Three-Dimensional Space

  • Kim, Minsung;Kim, Mingon;Park, Sumin;Kwon, Junghoon;Park, Jaeheung
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.13 no.2
    • /
    • pp.124-132
    • /
    • 2013
  • This study investigated the feasibility of gait recognition using points on the body in three-dimensional (3D) space based on comparisons of four different feature vectors. To obtain the point trajectories on the body in 3D, gait motion data were captured from 10 participants using a 3D motion capture system, and four shoes with different heel heights were used to study the effects of heel height on gait recognition. Finally, the recognition rates were compared using four methods and different heel heights.

Analysis of Skin Movements with Respect to Bone Motions using MR Images

  • Ryu, Jae-Hun;Miyata, Natsuki;Kouchi, Makiko;Mochimaru, Masaaki;Lee, Kwan H.
    • International Journal of CAD/CAM
    • /
    • v.3 no.1_2
    • /
    • pp.61-66
    • /
    • 2003
  • This paper describes a novel experiment that measures skin movement with respect to the flexional motion of a hand. The study was based on MR images in conjunction with CAD techniques. The MR images of the hand were captured in 3 different postures with surface markers. The surface markers attached to the skin where employed to trace skin movement during the flexional motion of the hand. After reconstructing 3D isosurfaces from the segmented MR images, the global registration was applied to the 3D models based on the particular bone shape of different postures. Skin movement was interpreted by measuring the centers of the surface markers in the registered models.

Biomechanical Analysis and Evaluation Technology Using Human Multi-Body Dynamic Model (인체 다물체 동역학 모델을 이용한 생체역학 분석 및 평가 기술)

  • Kim, Yoon-Hyuk;Shin, June-Ho;Khurelbaatar, Tsolmonbaatar
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.494-499
    • /
    • 2011
  • This paper presents the biomechanical analysis and evaluation technology of musculoskeletal system by multi-body human dynamic model and 3-D motion capture data. First, medical image based geometric model and material properties of tissue were used to develop the human dynamic model and 3-D motion capture data based motion analysis techniques were develop to quantify the in-vivo joint kinematics, joint moment, joint force, and muscle force. Walking and push-up motion was investigated using the developed model. The present model and technologies would be useful to apply the biomechanical analysis and evaluation of human activities.

Relationship between 3D Ground Reaction Force and Leg Length Discrepancy during Gait among Standing Workers

  • Kim, Yong-Wook
    • PNF and Movement
    • /
    • v.20 no.1
    • /
    • pp.59-66
    • /
    • 2022
  • Purpose: The aim of this research was to verify the relationship between three-dimensional (3D) ground reaction force (GRF) and severity of leg length discrepancy (LLD) while walking at a normal speed. It used a 3D motion analysis system with force platforms in standing workers with LLD. Methods: Subjects comprising 45 standing workers with LLD were selected. Two force platforms were used to acquire 3D GRF data based on a motion analysis system during gait. Vicon Nexus and Visual3D v6 Professional software were used to analyze kinetic GRF data. The subjects were asked to walk on a walkway with 40 infrared reflective markers attached to their lower extremities to collect 3D GRF data. Results: The results indicated the maximal force in the posterior and lateral direction of the long limb occurring in the early stance phase during gait had significant positive correlation with LLD severity (r = 0.664~0.738, p <0.01). In addition, the maximal force medial direction of the long limb occurring in the late stance phase showed a highly positive correlation with the LLD measurement (r = 0.527, p <0.01). Conclusion: Our results indicate that greater measured LLD severity results in more plantar pressure occurring in the foot area during heel contact to loading response of the stance phase and the stance push-off period during gait.

Development of an Advanced Deformable Phantom to Analyze Dose Differences due to Respiratory Motion

  • Shin, Dong-Seok;Kang, Seong-Hee;Kim, Dong-Su;Kim, Tae-Ho;Kim, Kyeong-Hyeon;Koo, Hyun-Jae;Cho, Min-Seok;Ha, Jin-Suk;Yoon, Do-Kun;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.28 no.1
    • /
    • pp.1-10
    • /
    • 2017
  • The difference between three-dimensional (3D) and four-dimensional (4D) dose could be affected by factors such as tumor size and motion. To quantitatively analyze the effects of these factors, a phantom that can independently control each factor is required. The purpose of this study is to develop a deformable lung phantom with the above attributes and evaluate the characteristics. A phantom was designed to simulate diaphragm motion with amplitude in the range 1~7 cm and period up to ${\geq}2s$ of regular breathing. To simulate different tumors sizes, custom molds were created using a 3D printer and filled with liquid silicone. The accuracy of the phantom diaphragm motion was assessed by comparing measured motion with predicted motion. Because the phantom diaphragm motion is not identical to the tumor motion, the correlation between the diaphragm and tumor motions was calculated by a curve fitting method to emulate user-intended tumor motion. Tumors of different sizes were located at same position, and tumor set-up positions were evaluated. The accuracy of phantom diaphragm motion was better than 1 mm. The diaphragm-tumor correlation showed that the tumor motion in the superior-inferior direction increased with increasing diaphragm motion. The tumor motion was larger in the $10cm^3$ tumor than in the $90cm^3$ tumor. The range of difference between the tumor set-up positions was 0 to 0.45 cm. This phantom showed independently adjusting factors such as tumor size and motion to facilitate quantitative analysis of the dosimetric impact of respiratory motion according to these factors.

Comparison and Analysis of Motion Capture and Key Animation - Focused on Animation of Countenance - (모션 캡처와 키 애니메이션의 비교분석 - 얼굴표정애니메이션을 중심으로 -)

  • Jang, Wook;Choi, Sung-Kyu;Lee, Tae-Gu
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.4
    • /
    • pp.160-169
    • /
    • 2007
  • Main problem in the domestic motion capture type production is that motion data are used even in the case when the human sensibility is needed. In other words it fails to give human images to the work, and production method only use motion capture data unconditionally and impetuously. Even though motion capture is effective and are various and applicable to various areas, it would cause enormous lose of capital and manual labor if these problems are not solved. In the present study, we compare motion capture with key animation production and analyze the merits and short comings of them. Also, we analyze them through the actual production and present the efficient method of key animation production when the expensive motion capturing devices are not available.