• 제목/요약/키워드: 3D LCD

검색결과 232건 처리시간 0.032초

Characterization of one Time-Sequential Stereoscopic 3D Display - Part I: Temporal Analysis -

  • Pierre, Boher;Thierry, Leroux;Collomb-Patton, Veronique
    • Journal of Information Display
    • /
    • 제11권2호
    • /
    • pp.57-62
    • /
    • 2010
  • A method of characterizing time-sequential stereoscopic 3D displays based on the measurement of the temporal behavior of the systems vs. the grey levels is proposed. An Nvidia 3D vision kit with a 3D-ready SAMSUNG 2233RZ LCD display is characterized in the paper. OPTISCOPE SA especially designed for the precise measurements of the luminance and temporal behavior of LCD displays was used. The transmittance and response time of the shutter glasses was first evaluated. Then the grey-to-grey response times of the display were measured. The 2D and 3D behaviors of the display were then compared. Finally, the temporal behavior of the complete system was modeled, and the grey-level variations on one view were deduced as a function of the synchronization and level of the other eye. The main sources of imperfection were identified and quantified, and a full computation of the system performances was done.

3차원 내시경술을 위한 양안 입체 영상처리 및 디스플레이 방법 (Method of Display and Processing of Binocular Stereoscopic Image for 3D Endoscopy)

  • 송철규
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권5호
    • /
    • pp.531-538
    • /
    • 1998
  • 본 논문은 내시경 수술시 입체영상을 제공하여 수술의 편리성과 정확성을 향상시키기 위한 고화질 3차원 내시경 영상의 처리와 디스플레이 방법을 연구하였다. 기존의 3타원 내시경 수술을 위한 디스플레이 방법은 안경 차용의 무게감과 플리커가 심한 전자셔터 방식으로 사용의 불편함이 많았다 된 연구에서는 기존 내시경 영상의 3D 디스플레이 방식인 전자셔터식에 대한 입체 영상의 특징을 분석하고, 이에 대한 문제점을 보완하기 위한 편광방식의 입체 영상처리와 재현 방법에 대하여 연구하였다. 또한 설계한 디스플레이 시스템의 성능 평가를 수행하여 기존 방식인 CRT방식에 의한 영상재현 방법에 비해 화질과 시야각 특성에서 우수함을 확인하였다.

  • PDF

LCD Module내 COF Bending에 따른 Lead Broken Failure의 개선 (Improvement of COF Bending-induced Lead Broken Failure in LCD Module)

  • 심범주;최열;이준신
    • 한국전기전자재료학회논문지
    • /
    • 제21권3호
    • /
    • pp.265-271
    • /
    • 2008
  • TCP(Tape Carrier Package), COG (Chip On Glass), COF(Chip On Film) are three methods for connecting LDI(LCD Driver IC) with LCD panels. Especially COF is growing its portion of market place because of low cost and fine pitch correspondence. But COF has a problem of the lead broken failure in LCD module process and the usage of customer. During PCB (Printed Circuit Board) bonding process, the mismatch of the coefficient of thermal expansion between PCB and D-IC makes stress-concentration in COF lead, and also D-IC bending process during module assembly process makes the level of stress in COF lead higher. As an affecting factors of lead-broken failure, the effects of SR(Solder Resister) coating on the COF lead, surface roughness and grain size of COF lead, PI(Polyimide) film thickness, lead width and the ACF(Anisotropic Conductive Film) overlap were studied, The optimization of these affecting manufacturing processes and materials were suggested and verified to prevent the lead-broken failure.

용접방식을 적용한 평면디스플레이용 화학기상증착기의 알루미늄 진공챔버 제조에 관한 연구 (Study on the Fabrication of Aluminum Vacuum Chamber of Chemical Vapor Depositor for Flat Display with Welding Method)

  • 정나겸;김훈식;김상준;장기범;장관섭
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2018년도 춘계학술대회 논문집
    • /
    • pp.76-76
    • /
    • 2018
  • LCD 디스플레이 크기는 점차 대형화를 이루면서, 현재 LCD 디스플레이 크기는 3,000*3,320mm 크기까지 증가하여 개발이 활발이 이루어지고 있다. 디스플레이의 크기가 증가함에 따라 제조 장비의 크기도 증가되어야 하므로, LCD 디스플레이 CVD 공정에 사용되는 4,200*3,300mm 크기의 대형 Aluminium Vacuum Chamber 에 피막두께 $15{\mu}m$ 이상을 구현함과 동시에 두께 균일도가 우수하며 염수분무시험으로 168시간 이상의 내식성 확보가 가능한 양극산화조건 개발을 위하여 양극산화 피막의 각종 특성 평가를 실시하였다. 양극산화 피막 두께 측정은 와전류(Eddy Current)의 원리를 이용한 비파괴식 두께 측정법(ISO 2360, ASTM D 7091)을 적용하였으며, 염수분무시험 방법은 (KS D 9502)을 적용하였으며, HCl bubble stream 시험 방법은 HCl 5% 농도를 투명 아크릴 튜브에 채운후 bubble stream 을 종점으로 하여 평가를 실시하였으며, 열충격을 이용한 도금밀착성(KS D 0254), 도장접착력(ASTM D 3359) 등을 이용하여 전해조건 및 전해액 농도에 따른 피막 특성 비교평가를 실시하여 최적의 대형 Aluminium Vacuum Chamber 양극산화 전해 조건을 개발하여 4,200*3,300mm 크기의 대형 Aluminium Vacuum Chamber 제조를 목적으로 하였다.

  • PDF

15-4 : Development of an Advanced Double-Sided LCD Using a Single LC Panel and Two Lighting Systems for Mobile Applications

  • Kang, Seung-Gon;Cho, Yong-Ku;Hong, Han-Young;Hwang, Hyun-Ha;Kim, Sung-Ho;Park, Jong- Sool
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.294-297
    • /
    • 2006
  • Using a single LC panel and two lighting systems, we have developed an advanced LCD system called "Double-Sided LCD." It has only one LC panel and two lighting systems, but it can display images of the same size and resolution on both the front and the rear side. Furthermore, utilizing a simple and thin lighting system we have reduced dramatically its module thickness up to 3.0mm, much thinner than that of conventional dual-type LCD, which is quite appropriate for the use of mobile applications.

  • PDF

TFT-LCD의 3차원 영상출력을 위한 렌티큘러 렌즈 최적설계 (Optimal Design of Lenticular Lens Sheet for the 3D Display on TFT-LCDs)

  • 김일주;박우상
    • 한국전기전자재료학회논문지
    • /
    • 제22권3호
    • /
    • pp.257-261
    • /
    • 2009
  • In this study, we have researched the optimum design method of the lenticular lens sheet for 3D displays on a TFT-LCD panel, to offer a more stable stereoscopic image, improved 3D quality, and a wider viewing zone. Especially, we have defined the viewing zone width (a parameter denoted as Z) to apply it to the optimum design. The results of this new design method have been compared with the existing design method. As a result, it is revealed that the proposed design method improves the stereoscopic image quality by reducing the black matrix zone width.

12주 동안의 저열량식사와 행동수정요법이 비만여성의 체격지수와 생화학적 영양상태에 미치는 영향 (Effect of 12-week Low Calorie Diet and Behavior Modification on the Anthropomeric Indices and Biochemical Nutritional Status of Obese Woman)

  • 손숙미;김희준
    • 대한지역사회영양학회지
    • /
    • 제10권4호
    • /
    • pp.525-535
    • /
    • 2005
  • This study was conducted to investigate the effect of a 3 week low calorie diet (LCD) and a 9 week of behavior modification (BM) program on the weight loss, mineral and vitamin status in 22 obese women. The subject were healthy, obese (PIBW> $120\%$) women aged 20 - 50 Yr and not taking any medications known to influence body composition, mineral or vitamin metabolism During the LCD program, subjects were provided commercial liquid formulas with 125 kcal per pack and were instructed to have a formula for replacement of one meal and at least one regular meal per day within the range of daily 800 - 1200 kcal intake. During the BM program the subjects weekly attended the group nutrition counseling session to encourage themselves to modify their eating behavior and spontaneously restrict their energy intakes. The BM program focused on stimulus control, control of portion sizes and modification of binge eating and other adverse habits. The initial mean energy intake of subjects was 2016.9 $\pm$ 129.8 kcal ($100.8\%$ of RDA) and dropped to 1276.5 $\pm$ 435.7 kcal at the end of a 3 week of LCD program and elevated to 1762 $\pm$ 329.3 kcal at the end of a 9 week of BM program. Carbohydrate, protein and fat intakes were significantly decreased at the end of the LCD but carbohydrate was the only macro nutrient that showed significant decrease (p < 0.05) at the end of the BM program compared to baseline. Calcium and iron intakes decreased significantly (p < 0.01, respectively) with no significant changes in other micronutrients at the end of the LCD. The mean weight of the subjects decreased from 73.8 $\pm$ 8.0 kg to 69.2 $\pm$ 7.7 kg with LCD and ended up with 67.7 $\pm$ 7.1 kg after 9 weeks of BM. The 3 weeks of LCD reduced most of the anthropometric indices such as BMI, PIBW, fat weight, wast-to-hip ratio and subscapular and suprailiac skinfold thickness. The 9 weeks of behavior modification showed slight change or maintenance of each anthropometric measurements. Weight loss and decreased WHR with the diet program induced significantly decreased systolic blood pressure. SGOT, SGPT and serum insulin levels with improved serum lipid profiles. Biochemical parameters related to iron status such as hemoglobin, hematocrit were significantly decreased (p < 0.01) at the end of the LCD. But their mean values were within normal range. The mean serum 25 (OH) vitamin $D_3$ level significantly increased after whole diet program. Serum folate level significantly decreased after 12 weeks of diet program. In conclusion 3 weeks of LCD brought 4.6 kg reduction in body weight without risk of iron, zinc or vitamin D deficiency and 9 weeks of the BM was effective to maintain nutritional status with slightly more weight reduction (1.5 kg). However calcium intake and serum folate should be monitored during the LCD and BM because of increased risk of deficiencies.

3차원 동영상을 구현하기 위한 실시간 홀로그램의 제작 (Fabrication of Real-Time Hologram for the Implementation of 3-D Moving Picture)

  • 배장근;박세준;김수중
    • 전자공학회논문지T
    • /
    • 제36T권1호
    • /
    • pp.25-31
    • /
    • 1999
  • CCD 카메라와 LCD를 사용하여 실시간 홀로그램 제작방법을 제안하였다. 본 시스템은 백색광을 사용하여 3차원 영상을 재생하기 위한 무지개 홀로그램 방법을 사용하였으며, CCD카메라의 낮은 해상도를 감안하여 간섭패턴의 간격을 크게 할 수 있는 in-line 홀로그램 제작방법을 사용하였다. 제안한 구성도로 간섭된 간섭패턴은 CCD카메라에 감지되고 비디오신호로 변환되어 LCD에 입력된다. 간섭패턴이 입력된 LCD에 백색광을 조사하여 영상을 재생하면 입체영상을 볼 수 있으며, 입력영상의 위치를 변화하면 재생영상도 같이 움직이는 실시간 홀로그램이 된다. 본 논문에서 제안된 방법이 백색광을 사용한 실시간 홀로그램 제작에 유용함을 확인하기 위하여 해상도가 높은 홀로그래픽 필름에 먼저 기록하여 재생해보고, 이를 다시 LCD에 기록하고 재생한 후 그 결과를 비교하였다. 또 기록시 기준파와 물체파의 세기비를 변화시켜 최적의 간섭조건을 도출하였다.

  • PDF

LCD 모듈전용 충격해석시스템 개발 (Development of LCD-Oriented Impact Analysis System)

  • 최성식;이정권
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1419-1424
    • /
    • 2003
  • Impact analysis of TFT-LCD module is very complicated because the structure is assisted with thin, small and non-uniform geometry. Especially, finite element modeling is more difficult and need time-consuming efforts. In this study, we developed LCD Impact Analysis System (LIAS) for the purpose of reducing the analysis time without accuracy reduction. This system contains pre-meshing data, material database, shock condition, auto-reporting etc. PATRAN and DYNA3D is used for meshing and solving. Previously, we performed impact test and reviewed the accuracy of analysis results. Simply we can control design parameters, the procedure such as meshing, running and reporting which are partially auto-prepared. By adopting proposed system, it is expected to achieve efficient impact analysis of LCD module.

  • PDF

TFT-LCD 모듈의 충격해석을 통한 내충격설계 연구 (Study on Shock Resistance Design of TFT-LCD Module using Explicit Impact Analysis)

  • 김진곤;이재곤
    • 동력기계공학회지
    • /
    • 제14권5호
    • /
    • pp.24-29
    • /
    • 2010
  • TFT-LCD module with thin, small and layered structure makes its shock analysis very difficult and complicated. As TFT-LCD becomes more thinner, it is more difficult to assure its required shock resistance. Recently, the drop/impact simulation using the commercial explicit dynamic analysis software such as LS-DYNA3D is actively applied to assess the shock characteristics of TFT-LCD. In this study, the effects of analysis parameters and design modifications in the drop/impact simulation are carefully studied. the reliability of the present analysis results can be assured through the experimental verification.