• Title/Summary/Keyword: 3D Finite Element Method

Search Result 1,367, Processing Time 0.032 seconds

Study on Buckling of Composite Laminated Cylindrical Shells with Transverse Rib (횡리브로 보강된 복합적층 원통형 쉘의 좌굴거동에 관한 연구)

  • Chang, Suk Yoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.4 s.71
    • /
    • pp.493-500
    • /
    • 2004
  • In this study, the effects of ring stiffeners for buckling of cylindrical shells with composite materials were analyzed. The finite element method was used: 3-D beam elements were used for stiffeners and flat shell elements were used for cylindrical shells and were improved by introducing a substitute shear strain. The ring stiffeners were of the transverse rib type. The buckling behaviors of the cylindrical shells were analyzed based on various parameters, such as locations and sizes of stiffeners, diameter/length ratios and boundary conditions of shells, and fiber-reinforced angles. Effective reinforcement was examined by understanding the exact behaviors for buckling. The results of the analysis may serve as references for designs and future investigations.

Calculation Method and Influence Factor for Speed Change of a Vehicle Impacting Small Sign Post (소형지주에 충돌하는 차량의 속도변화 산정방법과 영향인자)

  • Ko, Man-Gi;Kim, Kee-Dong;Jun, Sung-Min;Sung, Jung-Gon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.47-52
    • /
    • 2008
  • Important factor in designing a breakaway sign support is the velocity change of the impact vehicle. It is measured from the crash test or can be calculated by 3-D Finite Element Analysis. It can also be calculated with relative ease utilizing energy and momentum conservation. In this paper a formula to calculate the velocity change of a car during the time of impact against a small sign is derived utilizing the energy and momentum balance. Using the formula, parametric studies were conducted to find that impact speed, separation force and Breakaway Fracture Energy(BFE) of the posts which represent the degree of fixedness to the foundation are the important factor to vehicle's speed change. It is shown that speed change is larger in the lower speed impact and to the posts with large separation force and BFE.

The stress analysis of supporting tissues according to crown restorative materials in Brånemark osseointegrated implant (Brånemark 골유착성 매식체의 금관 수복재료에 따른 지지조직의 응력분석)

  • Jeong, Gwan-Ho;Bae, Tae Seong;Song, Kwang-Yeob;Park, Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.199-215
    • /
    • 1990
  • This study was to analyze the stress distribution of implant and supporting tissue in $Br{\aa}nemark$ osseointegration implant. The analysis has been conducted by using the axisymmetric finite element method and type of model according to crown material. Tests have been performed at 1 kg load on central fossa of crown portion. Each type of model was designed differently according to crown material. 1) Porcelain fused to metal crown(Model A) 2) Composite resin veneered crown(Model B) 3) Acrylic resin veneered crown(Model C) 4) Type III gold crown(Model D) The displacements and stresses of implant and supporting structures were analyzed to investigate the influence of the type of crown material. The results were obtained as follows : 1. Displacement of implant was shown uniformly downward displacement in all models and abutments were observed distally downward displacement. 2. In supporting tissues, stress was concentrated on the crest of compact bone and the spongy bone below implant. 3. The PFM and the type III gold crown showed the largest concentration of stress at the crest of compact bone and the spongy bone below implant, respectively. Acrylic resin artificial teeth and composite resin veneered crown indicated almost the same distribution of stress. 4. The gold screw, the abutment screw and the top of abutment showed the concentration of stress in implants of every model.

  • PDF

FE validation of the equivalent diameter calculation model for grouped headed studs

  • Spremic, Milan;Pavlovic, Marko;Markovic, Zlatko;Veljkovic, Milan;Budjevac, Dragan
    • Steel and Composite Structures
    • /
    • v.26 no.3
    • /
    • pp.375-386
    • /
    • 2018
  • Existing design codes for steel-concrete composite structures give only general information about the shear connection provided by headed studs in group arrangement. Grouting of the openings in prefabricated concrete slabs, where the grouped headed studs are placed in the deck pockets is alternative to cast-in-place decks to accomplish fast execution of composite structures. This paper considers the possibility to reduce the distance between the studs within the group, bellow the Eurocode limitations. This may lead to increased competitiveness of the prefabricated construction because more studs are placed in the group if negative effectives of smaller distances between studs are limited. The main purpose of this work is to investigate these limits and propose an analytical calculation model for prediction of the shear resistance of grouped stud arrangements in the deck pockets. An advanced FEA model, validated by results of push-out experiments, is used to analyze the shear behavior of the grouped stud with smaller distance between them than recommended by EN 1994-1. Calculation model for shear resistance, which is consistent with the existing Eurocode rules, is proposed based on a newly introduced equivalent diameter of the stud group, $d_G$. The new calculation model is validated by comparison to the results of FE parametric study. The distance between the studs in the longitudinal direction and the number of stud rows and columns in the group are considered as the main variables.

Effects of Axial Misalignments on the Torque Specimens Using Finite Element Analysis (유한요소해석기법을 이용한 토크 시편의 축 오열 영향 분석)

  • Kim, Ju-Hee;Kim, Yun-Jae;Huh, Yong-Hak
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.11
    • /
    • pp.1461-1469
    • /
    • 2011
  • Using three-dimensional (3-D) FE analyses, this paper provides a method for analyzing the effects on stresses and strains produced by angular and concentric misalignment of a test specimen for a torsion test. To quantitativele compare of the FE results, the average bending strain for the angular, concentric, and combined misalignment was proposed. To verify the effects of axial misalignment of the test specimens, we used both circular and tubular specimens. From the FE results, we proposed general predictions for the effects caused by the various types of axial misalignment and its direction. In addition, we confirmed the effect of initial yielding moment based on the initial yielding condition for axial misalignment of specimens in torsion tests.

Numerical Analysis of Welding Residual Stresses for Ultra-Thick Plate of EH40 Steel Joined by Tandem EGW (극후판 EH40 TMCP강재 Tandem EGW 용접부의 잔류응력 해석)

  • Hwang, Se-Yun;Lee, Jang-Hyun;Kim, Byung-Jong;Yang, Yong-Sik
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.6
    • /
    • pp.821-830
    • /
    • 2010
  • Deck plates and hatch coming of large container carrier and offshore structures are joined by ultra-thick plates whose thickness is more than 60mm. Traditionally FCAW has been used to join the thick plates in butt joint. However, FCAW has been replaced with EGW since the welding efficiency of EGW is higher than that of FCAW. Tandem EGW using two electrodes has been applied to vertical position welding by several shipyards. EGW requires one or two layers of bead whereas FCAW requires more than 20 layers of weld bead in thick welding. However, high welding residual stresses are generated by EGW since it uses higher heat input than FCAW. In the present study, a finite element model is suggested to predict the residual stresses induced by the tandem EGW. Butt specimen of EH40 TMCP shipbuilding steel plates vertical welding was modeled by a three-dimensional model. Residual stresses were measured by X-ray diffraction method and to verify the numerical result. The results show a good agreement with experimental result.

Numerical modeling of uplift resistance of buried pipelines in sand, reinforced with geogrid and innovative grid-anchor system

  • Mahdi, Majid;Katebi, Hooshang
    • Geomechanics and Engineering
    • /
    • v.9 no.6
    • /
    • pp.757-774
    • /
    • 2015
  • Reinforcing soils with the geosynthetics have been shown to be an effective method for improving the uplift capacity of granular soils. The pull-out resistance of the reinforcing elements is one of the most notable factors in increasing the uplift capacity. In this paper, a new reinforcing element including the elements (anchors) attached to the ordinary geogrid for increasing the pull-out resistance of the reinforcement, is used. Thus, the reinforcement consists of the geogrid and anchors with the cylindrical plastic elements attached to it, namely grid-anchors. A three-dimensional numerical study, employing the commercial finite difference software FLAC-3D, was performed to investigate the uplift capacity of the pipelines buried in sand reinforced with this system. The models were used to investigate the effect of the pipe diameter, burial depth, soil density, number of the reinforcement layers, width of the reinforcement layer, and the stiffness of geogrid and anchors on the uplift resistance of the sandy soils. The outcomes reveal that, due to a developed longer failure surface, inclusion of grid-anchor system in a soil deposit outstandingly increases the uplift capacity. Compared to the multilayer reinforcement, the single layer reinforcement was more effective in enhancing the uplift capacity. Moreover, the efficiency of the reinforcement layer inclusion for uplift resistance in loose sand is higher than dense sand. Besides, the efficiency of reinforcement layer inclusion for uplift resistance in lower embedment ratios is higher. In addition, by increasing the pipe diameter, the efficiency of the reinforcement layer inclusion will be lower. Results demonstrate that, for the pipes with an outer diameter of 50 mm, the grid-anchor system of reinforcing can increase the uplift capacity 2.18 times greater than that for an ordinary geogrid and 3.20 times greater than that for non-reinforced sand.

Design of Axial Flux Permanent Magnetic Motor Using Soft Magnetic Composite Core (연자성 분말코어를 적용한 축방향 영구 자속형 전동기 설계)

  • Choi, Myung-Wook;Yang, Seung-Jin;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.4
    • /
    • pp.607-616
    • /
    • 2022
  • A new axial flux permanent magnet machine with soft magnetic composited cores is proposed for electric vehicle application in this paper. The windings and soft magnetic composited cores can be designed to form a very compact structure, and; thus, the torque density can be improved greatly. To obtain the a good flux concentrating ability, two toroidally wound internal stator machines are designed and analyzed, and the designed motor is with NdFeB magnet for high-performance electric vehicle application. The 3-D finite-element method is used to analyze the electromagnetic parameter and performance, for performance comparison, a commercial axial flux permanent magnet machine is used. The proposed motor reduced weight about 5.8%, produced torque higher than about 8Nm for existing motor.

Numerical Investigation of Load Carrying Capacity of Geogrid-Encased Stone Columns under Foundation Load (구조물 기초하중 작용시 지오그리드 보강 쇄석말뚝의 하중지지 특성에 관한 수치해석 연구)

  • Yoo, Chung-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.11
    • /
    • pp.75-86
    • /
    • 2009
  • This paper presents the results of a numerical investigation on load carrying capacity of geogrid-encased stone columns to use as load carrying column(s) supporting a foundation load. A validated 3D stress-pore pressure coupled model that can effectively show rapid drainage capability of stone columns and encasement effect of geogrid was adopted and a parametric study was carried out on a number of influencing factors. It is shown that the geogrid encased stone columns can be effectively used as foundation load supporting columns in soft ground. The results of numerical investigation were presented so that the relationship between the load carrying capacity of geogrid-encased stone columns and the influencing factors can be identified. Practical implications of the findings are also discussed.

Investigation on Support Mechanism of Geogrid-Encased Stone Columns in Soft Ground (연약지반에 시공되는 지오그리드 감쌈 스톤컬럼의 하중 지지 메카니즘에 관한 연구)

  • Yoo, Chung-Sik;Kim, Sun-Bin
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.12
    • /
    • pp.93-101
    • /
    • 2008
  • This paper presents the results of numerical investigation on support mechanism of geogrid-encased stone columns for use in soft ground improvement. A number of cases were analyzed using a 3D stress-pore pressure coupled model that can effectively model construction sequence and drainage as well as reinforcing effects of geogrid-encased stone columns. The results indicated that the geogrid encasement provides additional confinement effect that reduces vertical stress in the soft ground, thus resulting in less excess pore water pressures and associated settlement. Also revealed was that such a confinement effect depends on encasement length and stiffness of geogrid. It is also shown that there exist critical encasement length and stiffness of geogrid for a given condition.