• Title/Summary/Keyword: 3D Film Factor

Search Result 60, Processing Time 0.021 seconds

A Study on The Comic Presentation Through Three-Dimensional Shot (입체적인 쇼트를 통한 코믹연출연구)

  • Hwang, Kil-Nam;Kim, Jae-Woong
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.2
    • /
    • pp.91-99
    • /
    • 2008
  • When making a comic film, the comic presentation that uses stress and exaggeration is the important subject among other things. In this study we tried to investigate the comic effect using the movement of three-dimensional shot. To conduct this study, we extracted the shot manufactured through the Flow Motion of a 3D Production Program Virtual Camera and a High Speed Motion Picture Camera. The shot manufactured applying this manufacturing skill and using three-dimensional production method for the video contents efficiently made was classified into several scenes. The focus of this study is to search for the factor that makes the atmosphere of a story comic through three-dimensional production shot. According to the shot analysis, three-dimensional production method plays a role in developing more stories on space and time by visualizing stories in three dimensions, which makes the most use of the movement of camera, lens and the utilization of focus. In addition, in the presentation where many comic and exaggerated factors are provided, we used the technology that stresses a scene using the size of a shot and the lasting time and presented the method that exaggerates space using a 3D Production Program Virtual Camera and a High Speed Motion Picture Camera. By reviewing the qualitative improvement and the efficient method on making comic films through the possibility that the atmosphere of this three-dimensional shot can apply to the effect for comic presentation, we tried to approach the comic presentation.

Characteristics of Groundwater Quality for Agricultural Irrigation in Plastic Film House Using Multivariate Analysis (다변량분석법을 이용한 시설재배지 지하수 수질 특성)

  • Kim, Jin-Ho;Choi, Chul-Mann;Lee, Jong-Sik;Yun, Sun-Gang;Lee, Jung-Taek;Cho, Kwang-Rae;Lim, Su-Jung;Choi, Seung-Chul;Lee, Gyeong-Ja;Kwon, Yeu-Seok;Kyung, Ki-Chon;Uhm, Mi-Jeong;Kim, Hee-Kwon;Lee, You-Seok;Kim, Chan-Yong;Lee, Seong-Tae;Ryu, Jong-Su
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • The main purpose of this study is to accumulate the fundamental data representing groundwater of plastic film houses by means of water quality and its multivariate statistical analysis. Groundwater samples were collected in every two years since 2000 to 2004 from total 211 sites. According to the result of water quality analysis, ground water quality was suitable for irrigation purpose averagely. Correlation analysis showed that EC was highest positively correlated with $Mg^{2+}$ to 0.810(p<0.01), 0.776(p<0.01) in April and July, respectively. $NO_3-N$ was highest positively correlated with T-N to 0.794(p<0.01) in October. This result shows that it can lead to a different result even in similar case sometimes. Four factors were extracted through factor analysis in April and July, but five factors were extracted in October. The proportions of cumulative variance by the factor were 64.9, 60.2, and 70.7 in April, July, and October, respectively. The first factor was highly related to anions and cations such as $Ca^{2+},\;Mg^{2+},\;Cl^-,\;{SO_4}^{2-}$, and EC in contrast to that of stream water. According to the cluster analysis, 211 sites are classified into four groups. Common type of ground water quality was shown in group A. The pH and $PO_4-P$ were highest in Group B. The anions and cations were highest in Group C. $COD_{Cr}$ was highest in Group D.

Dose Distribution and Design of Dynamic Wedge Filter for 3D Conformal Radiotherapy (방사선 입체조형치료를 위한 동적쐐기여과판의 고안과 조직내 선량분포 특성)

  • 추성실
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.77-88
    • /
    • 1998
  • Wedge shaped isodoses are desired in a number of clinical situations. Hard wedge filters have provided nominal angled isodoses with dosimetric consequences of beam hardening, increased peripheral dosing, nonidealized gradients at deep depths along with the practical consequendes of filter handling and placement problems. Dynamic wedging uses a combination of a moving collimator and changing monitor dose to achieve angled isodoses. The segmented treatment tables(STT) that monitor unit setting by every distance of moving collimator, was induced by numerical formular. The characteristics of dynamic wedge by STT compared with real dosimetry. Methods and Materials : The accelerator CLINAC 2100C/D at Yonsei Cancer Center has two photon energies (6MV and 10MV), currently with dynamic wedge angles of 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$ and 60$^{\circ}$. The segmented treatment tables(STT) that drive the collimator in concert with a changing monitor unit are unique for field sizes ranging from 4.0cm to 20.0cm in 0.5cm steps. Transmission wedge factors were measured for each STT with an standard ion chamber. Isodose profiles, isodose curves, percentage depth dose for dynamic wedge filters were measured with film dosimetry. Dynamic wedge angle by STT was well coincident with film dosimetry. Percent depth doses were found to be closer to open field but more shallow than hard wedge filter. The wedge transmission factor were decreased by increased the wedge angle and more higher than hard wedge filters. Dynamic wedging probided more consistent gradients across the field compared with hard wedge filters. Dynamic wedging has practical and dosimetric advantages over hard filters for rapid setup and keeping from table collisions. Dynamic wedge filters are positive replacement for hard filters and introduction of dynamic conformal radiotherapy and intensity modulation radiotherapy in a future.

  • PDF

Plasma-Assisted Molecular Beam Epitaxy of InXGa1-XN Films on C-plane Sapphire Substrates (플라즈마분자선에피탁시법을 이용한 C-면 사파이어 기판 위질화인듐갈륨박막의 에피탁시 성장)

  • Shin, Eun-Jung;Lim, Dong-Seok;Lim, Se-Hwan;Han, Seok-Kyu;Lee, Hyo-Sung;Hong, Soon-Ku;Joeng, Myoung-Ho;Lee, Jeong-Yong;Yao, Takafumi
    • Korean Journal of Materials Research
    • /
    • v.22 no.4
    • /
    • pp.185-189
    • /
    • 2012
  • We report plasma-assisted molecular beam epitaxy of $In_XGa_{1-X}N$ films on c-plane sapphire substrates. Prior to the growth of $In_XGa_{1-X}N$ films, GaN film was grown on the nitride c-plane sapphire substrate by two-dimensional (2D) growth mode. For the growth of GaN, Ga flux of $3.7{\times}10^{-8}$ torr as a beam equivalent pressure (BEP) and a plasma power of 150 W with a nitrogen flow rate of 0.76 sccm were fixed. The growth of 2D GaN growth was confirmed by $in-situ$ reflection high-energy electron diffraction (RHEED) by observing a streaky RHEED pattern with a strong specular spot. InN films showed lower growth rates even with the same growth conditions (same growth temperature, same plasma condition, and same BEP value of III element) than those of GaN films. It was observed that the growth rate of GaN is 1.7 times higher than that of InN, which is probably caused by the higher vapor pressure of In. For the growth of $In_xGa_{1-x}N$ films with different In compositions, total III-element flux (Ga plus In BEPs) was set to $3.7{\times}10^{-8}$ torr, which was the BEP value for the 2D growth of GaN. The In compositions of the $In_xGa_{1-x}N$ films were determined to be 28, 41, 45, and 53% based on the peak position of (0002) reflection in x-ray ${\theta}-2{\theta}$ measurements. The growth of $In_xGa_{1-x}N$ films did not show a streaky RHEED pattern but showed spotty patterns with weak streaky lines. This means that the net sticking coefficients of In and Ga, considered based on the growth rates of GaN and InN, are not the only factor governing the growth mode; another factor such as migration velocity should be considered. The sample with an In composition of 41% showed the lowest full width at half maximum value of 0.20 degree from the x-ray (0002) omega rocking curve measurements and the lowest root mean square roughness value of 0.71 nm.

Simplistic QA for an Enhanced Dynamic Wedge using the Reversed Wedge Pair Method (역방향 조사방식을 통한 동적쐐기의 품질관리)

  • Lee Jeong Woo;Hong Semie;Suh Tae Suk
    • Progress in Medical Physics
    • /
    • v.15 no.3
    • /
    • pp.161-166
    • /
    • 2004
  • A simplistic quality assurance (QA) method was designed for a Linac built-in enhanced dynamic wedge (EDW), which can be utilized to make wedged beam distributions. For the purpose of implementing the EDW symmetry QA, a film dosimetry system, low speedy dosimetry film, film densitometer and 3D RTP system were used, and the films irradiated by means of a 60$^{\circ}$ Reversed wedge pair (REWP) method. The profiles were then analyzed in terms of their symmetries, including partial treatment, which is the case of stopping it abruptly during EDW irradiation, and the measured and calculated values compared using the Cad Plan Golden Segmented Treatment Table (Golden STT). The result of this experiment was in good agreement, within 1 %, of the 'reversed wedge pair counterbalance effect'. For the QA of the effective wedge factor (EWF), the authors measured EWFs in relation to the 10$^{\circ}$, 15$^{\circ}$, 20$^{\circ}$, 25$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$ and 60$^{\circ}$ EDW, which were compared with the calculated values using the correction factor derived from the Golden STT and the log files produced automatically during the process of EDW irradiation. By means of this method it was capable of check up the safety of effective wedge factor without any other dosimetry system. The EDW QA was able to be completed within 1 hour from irradiation to analysis as a consequence of the simplified QA procedure, with maximized effectiveness. Unlike the metal wedge system, the EDW system was heavily dependent on the dose rates and jaw movements; therefore, its features could potentially cause inaccuracy. The frequent simplistic QA for the EDW is essential, and could secure against the flaw of dynamic treatment that uses the EDW.

  • PDF

Comparison of Treatment Planning System(TPS) and actual Measurement on the surface under the electron beam therapy with bolus (전자선 치료 시 Bolus를 적용한 경우 표면선량의 Treatment Planning System(TPS) 계산 값과 실제 측정값의 비교)

  • Kim, Byeong Soo;Park, Ju Young;Park, Byoung Suk;Song, Yong Min;Park, Byung Soo;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.163-170
    • /
    • 2014
  • Purpose : If electron, chosen for superficial oncotherapy, was applied with bolus, it could work as an important factor to a therapy result by showing a drastic change in surface dose. Hence the calculation value and the actual measurement value of surface dose of Treatment Planning System (TPS) according to four variables influencing surface dose when using bolus on an electron therapy were compared and analyzed in this paper. Materials and Methods : Four variables which frequently occur during the actual therapies (A: bolus thickness - 3, 5, 10 mm, B: field size - $6{\time}6$, $10{\time}10$, $15{\time}15cm2$, C: energy - 6, 9, 12 MeV, D: gantry angle - $0^{\circ}$, $15^{\circ}$) were set to compare the actual measurement value with TPS(Pinnacle 9.2, philips, USA). A computed tomography (lightspeed ultra 16, General Electric, USA) was performed using 16 cm-thick solid water phantom without bolus and total 54 beams where A, B, C, and D were combined after creating 3, 5 and 10 mm bolus on TPS were planned for a therapy. At this moment SSD 100 cm, 300 MU was investigated and measured twice repeatedly by placing it on iso-center by using EBT3 film(International Specialty Products, NJ, USA) to compare and analyze the actual measurement value and TPS. Measured film was analyzed with each average value and standard deviation value using digital flat bed scanner (Expression 10000XL, EPSON, USA) and dose density analyzing system (Complete Version 6.1, RIT, USA). Results : For the values according to the thickness of bolus, the actual measured values for 3, 5 and 10 mm were 101.41%, 99.58% and 101.28% higher respectively than the calculation values of TPS and the standard deviations were 0.0219, 0.0115 and 0.0190 respectively. The actual values according to the field size were $6{\time}6$, $10{\time}10$ and $15{\time}15cm2$ which were 99.63%, 101.40% and 101.24% higher respectively than the calculation values and the standard deviations were 0.0138, 0.0176 and 0.0220. The values according to energy were 6, 9, and 12 MeV which were 99.72%, 100.60% and 101.96% higher respectively and the standard deviations were 0.0200, 0.0160 and 0.0164. The actual measurement value according to beam angle were measured 100.45% and 101.07% higher at $0^{\circ}$ and $15^{\circ}$ respectively and standard deviations were 0.0199 and 0.0190 so they were measured 0.62% higher at $15^{\circ}$ than $0^{\circ}$. Conclusion : As a result of analyzing the calculation value of TPS and measurement value according to the used variables in this paper, the values calculated with TPS on 5 mm bolus, $6{\time}6cm2$ field size and low-energy electron at $0^{\circ}$ gantry angle were closer to the measured values, however, it showed a modest difference within the error bound of maximum 2%. If it was beyond the bounds of variables selected in this paper using electron and bolus simultaneously, the actual measurement value could differ from TPS according to each variable, therefore QA for the accurate surface dose would have to be performed.

A Zinc Porphyrin Sensitizer Modified with Donor and Acceptor Groups for Dye-Sensitized Solar Cells

  • Lee, Seewoo;Sarker, Ashis K.;Hong, Jong-Dal
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.10
    • /
    • pp.3052-3058
    • /
    • 2014
  • In this article, we have designed and synthesized a novel donor-${\pi}$-acceptor (D-${\pi}$-A) type porphyrin-based sensitizer (denoted UI-5), in which a carboxyl anchoring group and a 9,9-dimethyl fluorene were introduced at the meso-positions of porphyrin ring via phenylethynyl and ethynyl bridging units, respectively. Long alkoxy chains in ortho-positions of the phenyls were supposed to reduce the degree of dye aggregation, which tends to affect electron injection yield in a photovoltaic cell. The cyclic voltammetry was employed to determine the band gap of UI-5 to be 1.41 eV based on the HOMO and LUMO energy levels, which were estimated by the onset oxidation and reduction potentials. The incident monochromatic photon-to-current conversion efficiency of the UI-5 DSSC assembled with double-layer (20 nm-sized $TiO_2$/400 nm-sized $TiO_2$) film electrodes appeared lower upon overall ranges of the excitation wavelengths, but exhibited a higher value over the NIR ranges (${\lambda}$ = 650-700 nm) compared to the common reference sensitizer N719. The UI-5-sensitized cell yielded a relatively poor device performance with an overall conversion efficiency of 0.74% with a short circuit photocurrent density of $3.05mA/cm^2$, an open circuit voltage of 0.54 mV and a fill factor of 0.44 under the standard global air mass (AM 1.5) solar conditions. However, our report about the synthesis and the photovoltaic characteristics of a porphyrin-based sensitizer in a D-${\pi}$-A structure demonstrated a significant complex relationship between the sensitizer structure and the cell performance.

Usefulness Evaluation of Mammographic Image (유방촬영 영상의 유용성 평가)

  • Kang, Se-Ssik
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.49-54
    • /
    • 2004
  • Purpose : To valuate the usefulness of mammographic image by using phantom 1,2 to controls the enhancement of image quality. Procedure : Set up same equipments for experiment (all the qualification must be the same). Control group and 4 other experiment the developing mammographys by using the image system with film/intensifying screen and distribute marks on each test objects of phantom 1, 2. Result : The results of the experiment using phantom 1, 2 on control group and 4 others are : 1. phantom 1's valuation with 3 items. - control group received 29 out of 32 - group A received 25 - group B received 16 - group C received 11.5 - group D received 28.5 The evaluation shows that the system has proved to display excellent image quality except group B and C. 2. Phantom 2's valuation with 4 items. - control group received 38 out of 38 - group A received 30 - group B received 16 - group C received 12.5 - group D received 38 Even with phantom 2, group B and C has displayed poor image quality. Conclusion : Both experiments using phantom 1 and 2 have shown that the most strong factor that control and influence the image quality are the filming equipments. Especially, the developing system has most powerful influence above all.

  • PDF

Electrical and Optical Properties for TCO/Si Junction of EWT Solar Cells (TCO/Si 접합 EWT 태양전지에 관한 전기적 및 광학적 특성)

  • Song, Jinseob;Yang, Jungyup;Lee, Junseok;Hong, Jinpyo;Cho, Younghyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.39.2-39.2
    • /
    • 2010
  • In this work we have investigated electrical and optical properties of interface for ITO/Si with shallow doped emitter. The ITO is prepared by DC magnetron sputter on p-type monocrystalline silicon substrate. As an experimental result, The transmittance at 640nm spectra is obtained an average transmittance over 85% in the visible range of the optical spectrum. The energy bandgap of ITO at oxygen flow from 0% to 4% obtained between 3.57eV and 3.68eV (ITO : 3.75eV). The energy bandgap of ITO is depending on the thickness, sturcture and doping concentration. Because the bandgap and position of absorption edge for degenerated semiconductor oxide are determined by two competing mechanism; i) bandgap narrowing due to electron-electron and electron-impurity effects on the valance and conduction bands (> 3.38eV), ii) bandgap widening by the Burstein-Moss effect, a blocking of the lowest states of the conduction band by excess electrons( < 4.15eV). The resistivity of ITO layer obtained about $6{\times}10^{-4}{\Omega}cm$ at 4% of oxygen flow. In case of decrease resistivity of ITO, the carrier concentration and carrier mobility of ITO film will be increased. The contact resistance of ITO/Si with shallow doped emitter was measured by the transmission line method(TLM). As an experimental result, the contact resistance was obtained $0.0705{\Omega}cm^2$ at 2% oxygen flow. It is formed ohmic-contact of interface ITO/Si substrate. The emitter series resistance of ITO/Si with shallow doped emitter was obtained $0.1821{\Omega}cm^2$. Therefore, As an PC1D simulation result, the fill factor of EWT solar cell obtained above 80%. The details will be presented in conference.

  • PDF

Conventional and Inverted Photovoltaic Cells Fabricated Using New Conjugated Polymer Comprising Fluorinated Benzotriazole and Benzodithiophene Derivative

  • Kim, Ji-Hoon;Song, Chang Eun;Kang, In-Nam;Shin, Won Suk;Zhang, Zhi-Guo;Li, Yongfang;Hwang, Do-Hoon
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.5
    • /
    • pp.1356-1364
    • /
    • 2014
  • A new conjugated copolymer, poly{4,8-bis(triisopropylsilylethynyl)benzo[1,2-b:4,5-b']dithiophene-alt-4,7- bis(5-thiophen-2-yl)-5,6-difluoro-2-(heptadecan-9-yl)-2H-benzo[d][1,2,3]triazole} (PTIPSBDT-DFDTBTz), is synthesized by Stille coupling polycondensation. The synthesized polymer has a band gap energy of 1.9 eV, and it absorbs light in the range 300-610 nm. The hole mobility of a solution-processed organic thin-film transistor fabricated using PTIPSBDT-DFDTBTz is $3.8{\times}10^{-3}cm^2V^{-1}s^{-1}$. Bulk heterojunction photovoltaic cells are fabricated, with a conventional device structure of ITO/PEDOT:PSS/polymer:$PC_{71}BM$/Ca/Al ($PC_{71}BM$ = [6,6]-phenyl-$C_{71}$-butyric acid methyl ester); the device shows a power conversion efficiency (PCE) of 2.86% with an open-circuit voltage ($V_{oc}$) of 0.85 V, a short-circuit current density ($J_{sc}$) of 7.60 mA $cm^{-2}$, and a fill factor (FF) of 0.44. Inverted photovoltaic cells with the structure ITO/ethoxylated polyethlyenimine/ polymer:$PC_{71}BM/MoO_3$/Ag are also fabricated; the device exhibits a maximum PCE of 2.92%, with a $V_{oc}$ of 0.89 V, a $J_{sc}$ of 6.81 mA $cm^{-2}$, and an FF of 0.48.