• 제목/요약/키워드: 3D Film Factor

검색결과 60건 처리시간 0.028초

Spinal Cord Partial Block Technique Using Dynamic MLC

  • Cho, Sam-Ju;Yi, Byong-Yong;Back, Geum-Mun;Lee, Sang wook;Ahn, Seung-Do;Kim, Jong-Hoon;Kwon, Soo-Il;Park, Eun-Kyung
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.138-140
    • /
    • 2002
  • The spinal cord dose is the one of the limiting factor for the radiation treatment of the head & neck (H&N) or the thorax region. Due to the fact that the cord is the elongated shaped structure, it is not an easy task to maintain the cord dose within the clinically acceptable dose range. To overcome this problem, the spinal cord partial block technique (PBT) with the dynamic Multi-Leaf Collimator (dMLC) has been developed. Three dimension (3D) conformal beam directions, which minimize the coverage of the normal organs such as the lung and the parotid gland, were chosen. The PBT field shape for each field was designed to shield the spinal cord with the dMLC. The transmission factors were determined by the forward calculation method. The plan comparisons between the conventional 3D conformal therapy plan and the PTB plan were performed to evaluate the validity of this technique. The conformity index (CI) and the dose volume histogram (DVH) were used as the plan comparison indices. A series of quality assurance (QA) was performed to guarantee the reliable treatment. The QA consisted of the film dosimetry for the verification of the dose distribution and the point measurements. The PBT plan always generated better results than the conventional 3D conformal plan. The PBT was proved to be useful for the H&N and thorax region.

  • PDF

RF Sputtering을 이용한 전류 민감성 차단 디바이스에 관한 연구 (The Study on a sensitive current limiting breaking device using RF Sputtering)

  • 이세현;정광희;박두기;김용락;이종철;구경완;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1088-1092
    • /
    • 1995
  • In this paper, we evaluated the sputter-deposited Cr/Cu thin film fuses on $Al_2O_3$ substrates by the adhesive, breaking and repetitive over-current test as a function of temperature on them. Each Cr and Cu was deposited $1700{\pm}300{\AA},\;3700{\pm}300{\AA}$ using RF sputtering unit. The electroplated Cu of $25{\mu}m$ thickness was added in order to make sensitive thin film fuse of the normal current 15[A]. The adhesive strength and the number of repetition were Increasing and then decreasing with the temperature. The maximum adhesive strength of over $9kgf/9mm^2$ was obtained at $400^{\circ}C$. In the breaking test, the post-arc time characteristic was better than any other factor.

  • PDF

페닐기 함유 열경화성 폴리유기실록산 코팅제 특성 (Characteristics of Heat Curable Polyorganosiloxane Coating Materials)

  • 이진혁;강두환;강호종
    • 폴리머
    • /
    • 제39권3호
    • /
    • pp.499-505
    • /
    • 2015
  • Dimethyldimethoxysilane(DMDMS), methyltrimethoxysilane(MTMS)과 phenyltrimethoxysilane(PTMS)을 이용하여 폴리유기실록산 열 경화성 코팅액을 제조하고 가교도와 페닐기 함량이 코팅액과 도막 물성에 미치는 영향을 살펴보았다. Si-NMR 측정에서 얻어진 D $T^{Me}$ $T^{Ph}$ 구조 코팅액 조성비가 사용된 DMDMS, MTMS, PTMS의 몰 비로부터 얻어진 이론치와 일치함을 확인할 수 있었다. 가교밀도가 높을수록 그리고 페닐 함량이 낮을수록 실록산 결합의 증가에 의하여 코팅액 분자량이 증가됨을 알 수 있으며 페닐기 증가는 코팅액 굴절률 증가에 매우 큰 영향을 미침을 알 수 있었다. 가교밀도가 높을수록, 페닐기 함량이 감소할수록 코팅도막 경도는 증가되었으며 내열특성 또한 우수해짐을 확인할 수 있었다. 이상의 결과로부터 같은 실록산 결합을 갖는 폴리유기실록산 코팅제라도 치환도에 따른 가교도 조절과 페닐기 함량에 따라 코팅액 물성이 달라짐을 확인할 수 있었다.

AlN 기판을 이용한 RF 고전력 증폭기 모듈 (RF High Power Amplifier Module using AlN Substrate)

  • 김승용;남충모
    • 한국전기전자재료학회논문지
    • /
    • 제22권10호
    • /
    • pp.826-831
    • /
    • 2009
  • In this paper, a high power RF amplifier module using AlN substrate of high thermal conductivity has been proposed. This RF amplifier module has the advantage of compact size and effective heat dissipation for the packaging of high power chip. To fabricate the thru-hole and scribing line on AlN substrate, the key parameters of $CO_2$ laser were experimented. And then, microstrip lines and spiral planar inductors were fabricated on an AlN substrate using the thin-film process. The fabricated microstrip lines on the AlN substrate has an attenuation value of 0.1 dB/mm up to 10 GHz. The fabricated spiral planar inductor has a high quality factor, a maximum of about 62 at 1 GHz for a 5.65 nH inductor. Packaging of a RF power amplifier was implemented on an AlN substrate with thru-hole. From the measured results, the gain is 24 dB from 13 to 15 GHz and the output power is 33.65 dBm(2.3 W).

Thermoelectric properties of multi-layered Bi-Te/In-Se/Bi-Te thin film deposited by RF magnetron sputter

  • ;;;;;;김진상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.231-231
    • /
    • 2010
  • Thermoelectric properties of a multi-layered thin film, which was composed with indium selenide and bismuth telluride, were investigated. The structure of the layered thin film is Bi-Te /In-Se/Bi-Te and it was prepared on sapphire substrate by RF magnetron sputter using stoichiometric $Bi_2Te_3$ (99.9%) and $In_2Se_3$(99.99%) target at room temperature. Then, it was annealed at temperature range of 150 - $500^{\circ}C$ in Ar ambient. Structural characterizations were done using X-ray diffraction(XRD, BRUKER, D8, 60kW) and transmission electron microscopy (TEM, FEI, Tecnai, F30 S-Twin), respectively. Cross-section of multi-layer structure was observed by Scanning electron microscopy (SEM). The resistivity and Seebeck coefficient of these samples were also measured by conventional equipment at room temperature. The maximum value of power factor was $1.16\;{\mu}W/k^2m$ at annealing temperature of $400^{\circ}C$.

  • PDF

방사선수술을 위한 3차원 정위 시스템 및 방사선량 측정 시스템 개발 (Development of 3-D Stereotactic Localization System and Radiation Measurement for Stereotactic Radiosurgery)

  • 서태석;서덕영;박승훈;장홍석;최보영;윤세철;신경섭;박용휘;김일환;강위생;하성환;박찬일
    • Journal of Radiation Protection and Research
    • /
    • 제20권1호
    • /
    • pp.25-36
    • /
    • 1995
  • The purpose of this research is to develop stereotactic localization and radiation measurement system for the efficient and precise radiosurgery. The algorithm to obtain a 3-D stereotactic coordinates of the target has been developed using a Fisher CT or angio localization. The procedure of stereotactic localization was programmed with PC computer, and consists of three steps: (1) transferring patient images into PC; (2) marking the position of target and reference points of the localizer from the patient image; (3) computing the stereotactic 3-D coordinates of target associated with position information of localizer. Coordinate transformation was quickly done on a real time base. The difference of coordinates computed from between Angio and CT localization method was within 2 mm, which could be generally accepted for the reliability of the localization system developed. We measured dose distribution in small fields of NEC 6 MVX linear accelerator using various detector; ion chamber, film, diode. Specific quantities measured include output factor, percent depth dose (PDD), tissue maximum ratio (TMR), off-axis ratio (OAR). There was small variation of measured data according to the different kinds of detectors used. The overall trends of measured beam data were similar enough to rely on our measurement. The measurement was performed with the use of hand-made spherical water phantom and film for standard arc set-up. We obtained the dose distribution as we expected. In conclusion, PC-based 3-D stereotactic localization system was developed to determine the stereotactic coordinate of the target. A convenient technique for the small field measurement was demonstrated. Those methods will be much helpful for the stereotactic radiosurgery.

  • PDF

CP-EAPap 생체모방 작동기의 제조 및 성능 (CP-EAPap biomimetic actuator fabrication and performance)

  • 이곡파;김재환;데시판데
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.360-363
    • /
    • 2005
  • Biomimetic actuators composed of cellophane with an electrically conducting polyaniline(PANI) film have been fabricated and tested in air ambience conditions doped with two different counter ions such as perchlorate (${ClO_4}^-$) and tetrafluoroborate (${BF_4}^-$). Fabrication of the trilayer CP//CELLOPHANE//CP substantially enhanced the tip displacement (13.2mm) compared to the small displacement (8.3mm) of the bilaye. CP//CELLOPHANE. The ion migration among layers is the main factor behind the expansion of cellophane, while the expansion/contraction of PANI are dependent on the redox reaction of the polymer. The displacement of the composite is dominated by the humidity content. This implies that the actuation principle is possibly due to the assistance of water existing.

  • PDF

진공증착중합법을 이용한 6FDA/4-4'DDE 폴리이미드 박막의 제조와 전기적 특성 (Electrical Properties and Preparation of 6FDA/4-4'DDE Polyimide Thin Films by Vapor Deposition Polymerization Method)

  • 황선양;이붕주;김형권;김영봉;박강식;임헌찬;강대하;박광현;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1487-1489
    • /
    • 1998
  • In this paper, thin films of PI were fabricated VDPM of dry processes which are easy to control the film's thickness and hard to pollute due to volatile solvents. From FT-lR, PAA thin films fabricated by VDP were changed to PI thin films by thermal curing. From SEM, AFM and Ellipsometer experimental, as the higher curing temperatures the films thickness decreases and reflectance increases. Therefore, Pl could be fabricated stable by increasing curing temperature. The relative permitivity and dissipation loss factor were 3.7 and 0.008. Also, the resistivity was about $1.05{\times}10^{15}{\Omega}cm$ at $30^{\circ}C$.

  • PDF

DC Magnetron Sputtering 방법으로 증착한 Fe-N 박막의 구조와 자기적 성질 (Structure and Magnetic Properties of Fe-N Films Deposited by Dc Magnetron Sputtering)

  • 이종화;이원종
    • 한국자기학회지
    • /
    • 제3권2호
    • /
    • pp.87-93
    • /
    • 1993
  • 질화철(Fe-N) 박막을 DC magenetron sputtering 방법으로 증착하였다. 스퍼터링 기체중의 질소유량비와 스퍼터링 power가 박막의 구조와 조성, 자기적 특성에 미치는 영향을 조사하였다. 증착 박막중의 질소원자 함유량은 박막의 구조, 생성상 및 자기적 특성을 결정짓는 지배적인 인자이다. 낮 은 질소 유량비에서 증착하였을 경우 박막은 질소 침입형 $\alpha$-Fe 결정구조를 갖으며, 질소원자 함유량에 비례하여 격자변형은 증가하고 포화자화값은 감소하였다. 격자변형이 어느 정도 심하게 일어 나면 주상정으로의 성장이 억제되어 평탄한 표면형상과 균일한 미세구조를 갖게되며, 자구벽의 이동이 용이하게 되어 보자력의 급격한 감소를 가져왔다. 질소유량비가 증가하여 박막내의 질소함유량이 15 at.%가 되면 격자정수 d(110)이 5% 증가하게 되며 이때 $Fe_{2-3}N$ 상으로의 상변화가 일어나 포화 자화값은 급격히 감소한다.

  • PDF

인체 감지용 강유전체 박막 초전형 적외선 센서의 제작 (Pyroelectric Infrared Microsensors Made for Human Body Detection)

  • 최준림
    • 센서학회지
    • /
    • 제7권2호
    • /
    • pp.103-110
    • /
    • 1998
  • 강유전체 박막과 마이크로 가공기술을 이용하여 초전형 적외선 센서를 제작하였다. 초전형 적외선 센서는 $Pb_{l-x}La_{x}Ti_{1-x/4}O_{3}$ (x=0.05) (PLT) 강유전체 박막 커패시터를 RF 마그네트론 스퍼터링 방식으로 백감 전극이 증착된 MgO 기판상에 결정 성장시킨 구조를 갖고 있다. 스퍼터링된 PLT 박막은 높은 c-축 결정 구조를 가지므로 센서로 사용하기 위한 분극 처리 과정이 필요 없다. 이는 적외선 이미지 센서를 구현함에 있어서 수율 향상에 필수적인 요소이다. 또한 마이크로 가공 기술을 사용하여 센서의 열용량을 극소화함으로서 센서의 효율을 최대화하였다. 제작된 센서의 상부에 폴리이미드를 코팅하고 MgO 기판을 선택적으로 식각하여 코팅된 폴리이미드와 MgO가 강유전체 박막 커패시터를 지지하고 있는 구조를 구현하였다. 이렇게 제작된 센서의 감도는 상온에서 $8.5{\times}10^{8}cm{\cdot}\sqrt{Hz}/W$로 측정되었으며 이는 마이크로 가공 기술을 사용하지 않은 경우보다 약 100 배의 감도 향상을 가져왔다. 2차원 배열 구조를 갖는 센서를 가지고 인체의 유 무 뿐만 아니라 위치까지 감별할 수 있는 센싱 시스템을 구현하였다.