• Title/Summary/Keyword: 3D Desktop

Search Result 71, Processing Time 0.036 seconds

Design and Implementation of a 3D Virtual Desktop System based on Windows Operation System (윈도우즈 운영체제 기반의 3D 가상 데스크톱 시스템 설계 및 구현)

  • Hong, Seung-Pyo;Oh, Myeong-Jin;Shin, Jung-Hoon;Lee, Sang-Jun
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.12
    • /
    • pp.1249-1253
    • /
    • 2010
  • As personal computers have been recently improved in performance, the multi tasking of running several applications at the same time has been generalized. Since only one task space is provided for performing such tasks on Windows operating system, a number of computer users feel inconvenient. In this paper, we propose a 3D Virtual Desktop System which can show a process of switching task spaces in 3D motion using DirectX. The proposed system can provide a computer user with more task spaces and the intuitive UI(User Interlace) such as Compiz of Linux.

Evaluation of Usefulness and Availability for Orthopedic Surgery using Clavicle Fracture Model Manufactured by Desktop 3D Printer (보급형 3D 프린터로 제작한 쇄골 골절 모델을 이용한 정형외과 수술에 대한 유용성과 활용가능성 평가)

  • Oh, Wang-Kyun
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.203-209
    • /
    • 2014
  • Usefulness and clinical availability for surgery efficiency were evaluated by conducting pre-operative planning with a model manufactured by desktop 3D printer by using clavicle CT image. The patient-customized clavicle fracture model was manufactured by desktop 3D printer of FDM wire laminated processing method by converting the CT image into STL file in Open Source DICOM Viewer Osirix. Also, the model of the original shape before damaged was restored and manufactured by Mirror technique based on STL file of not fractured clavicle of the other side by using the symmetry feature of the human body. For the model, the position and size, degree of the fracture was equally printed out. Using the clavicle model directly manufactured with low cost and less time in Department of Radiology is considered to be useful because it can reduce secondary damage during surgery and increase surgery efficiency with Minimal invasive percutaneous plate osteosynthesis(MIPO).

Comparative Study on the Interface and Interaction for Manipulating 3D Virtual Objects in a Virtual Reality Environment (가상현실 환경에서 3D 가상객체 조작을 위한 인터페이스와 인터랙션 비교 연구)

  • Park, Kyeong-Beom;Lee, Jae Yeol
    • Korean Journal of Computational Design and Engineering
    • /
    • v.21 no.1
    • /
    • pp.20-30
    • /
    • 2016
  • Recently immersive virtual reality (VR) becomes popular due to the advanced development of I/O interfaces and related SWs for effectively constructing VR environments. In particular, natural and intuitive manipulation of 3D virtual objects is still considered as one of the most important user interaction issues. This paper presents a comparative study on the manipulation and interaction of 3D virtual objects using different interfaces and interactions in three VR environments. The comparative study includes both quantitative and qualitative aspects. Three different experimental setups are 1) typical desktop-based VR using mouse and keyboard, 2) hand gesture-supported desktop VR using a Leap Motion sensor, and 3) immersive VR by wearing an HMD with hand gesture interaction using a Leap Motion sensor. In the desktop VR with hand gestures, the Leap Motion sensor is put on the desk. On the other hand, in the immersive VR, the sensor is mounted on the HMD so that the user can manipulate virtual objects in the front of the HMD. For the quantitative analysis, a task completion time and success rate were measured. Experimental tasks require complex 3D transformation such as simultaneous 3D translation and 3D rotation. For the qualitative analysis, various factors relating to user experience such as ease of use, natural interaction, and stressfulness were evaluated. The qualitative and quantitative analyses show that the immersive VR with the natural hand gesture provides more intuitive and natural interactions, supports fast and effective performance on task completion, but causes stressful condition.

Research On Solutions To Slicing Errors In FDM 3D Printing Of Thin-walled Structures

  • QINGYUAN ZHANG;Byung-Chun Lee
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.176-181
    • /
    • 2024
  • The desktop-level 3D printing machines makes it easier for independent designers to produce collectible models. Desktop 3D printers that use FDM (Fused Deposition Modeling) technology usually use a minimum nozzle diameter of 0.4mm. When using FDM printers to make Gunpla models, Thin slice structures are prone to slicing errors, which lead to deformation of printed objects and reduction in structural strength. This paper aims to analyze the printing model that produces errors, control a single variable among the three variables of slice layer height, slice wall thickness and filament type for comparative testing, and find a way to avoid gaps. To provide assistance for using FDM printers to build models containing thin-walled structures.

Effective 3D Object Selection Interface in Non-immersive Virtual Environment (비몰입형 가상환경에서 효과적인 3D객체선택 인터페이스)

  • 한덕수;임윤호;최윤철;임순범
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.5
    • /
    • pp.896-908
    • /
    • 2003
  • Interaction technique in .3D virtual environment is a decisive factor that affects the immersion and presence felt by users in virtual space. Especially, in fields that require exquisite manipulation of objects such as electronic manuals in desktop environment, interaction technique that supports effective and natural manipulation of object is in demand. In this paper, 3D scene graph can be internally divided and reconstructed to a list defending on the users selection and through moving focus among the selection candidate objects list, the user can select 3D object more accurately Also, by providing various feedbacks for each manipulation stage, more effective manipulation is possible. The proposed technique can be used as 3D user interface in areas that require exquisite object manipulation.

  • PDF

3D Spatial Information Service Methodologies of Landslide Area Using Web and Desktop Application (Web 및 Desktop Application을 이용한 산사태 지역의 3차원 공간정보서비스 방안)

  • Kim, Dong-Moon;Park, Jae-Kook;Yang, In-Tae
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2010.04a
    • /
    • pp.379-380
    • /
    • 2010
  • GIS has the basic ability to process high-dense and precise digital data like LiDAR. But the software that common users can use when necessary is expensive and practically impossible for actual use. Thus this study set out to research the methodologies to process and service time series LiDAR data for landslide monitoring.

  • PDF

Utilization of desktop 3D printer-fabricated "Cost-Effective" 3D models in orthognathic surgery

  • Narita, Masato;Takaki, Takashi;Shibahara, Takahiko;Iwamoto, Masashi;Yakushiji, Takashi;Kamio, Takashi
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.24.1-24.7
    • /
    • 2020
  • Background: In daily practice, three-dimensional patient-specific jawbone models (3D models) are a useful tool in surgical planning and simulation, resident training, patient education, and communication between the physicians in charge. The progressive improvements of the hardware and software have made it easy to obtain 3D models. Recently, in the field of oral and maxillofacial surgery, there are many reports on the benefits of 3D models. We introduced a desktop 3D printer in our department, and after a prolonged struggle, we successfully constructed an environment for the "in-house" fabrication of the previously outsourced 3D models that were initially outsourced. Through various efforts, it is now possible to supply inexpensive 3D models stably, and thus ensure safety and precision in surgeries. We report the cases in which inexpensive 3D models were used for orthodontic surgical simulation and discuss the surgical outcomes. Review: We explained the specific CT scanning considerations for 3D printing, 3D printing failures, and how to deal with them. We also used 3D models fabricated in our system to determine the contribution to the surgery. Based on the surgical outcomes of the two operators, we compared the operating time and the amount of bleeding for 25 patients who underwent surgery using a 3D model in preoperative simulations and 20 patients without using a 3D model. There was a statistically significant difference in the operating time between the two groups. Conclusions: In this article, we present, with surgical examples, our in-house practice of 3D simulation at low costs, the reality of 3D model fabrication, problems to be resolved, and some future prospects.

OpenGL ES 2.0 Emulation on Desktop PCs (데스크탑 상에서의 OpenGL ES 2.0 에뮬레이션)

  • Baek, Nakhoon
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.3 no.4
    • /
    • pp.125-128
    • /
    • 2014
  • OpenGL ES(OpenGL for Embedded System) 2.0 is one of the most widely used 3D graphics API(application progrma interface) standard for smart phones and tablet PCs at this time. During programming with this API, they prefer desktop environment rather than the target mobile environment, which has relatively low computing power. Thus, we need to emulate the OpenGL ES 2.0 API on the desktop PCs, where only OpenGL API libraries are available. In this paper, we present technical difficulties and their solutions to emulate OpenGL ES 2.0 on desktop PCs. Our final implementation of OpenGL ES 2.0 emulation library works on desktop PCs and passed over more than 96% of the official CTS(conformance test suites) to prove the correctness of our implementation. Additionally, for the commercially available benchmark programs, our implementation shows equivalent execution speeds to the previous commercial OpenGL ES 2.0 implementations.

Client Rendering Method for Desktop Virtualization Services

  • Jang, Su Min;Choi, Won Hyuk;Kim, Won Young
    • ETRI Journal
    • /
    • v.35 no.2
    • /
    • pp.348-351
    • /
    • 2013
  • Cloud computing has recently become a significant technology trend in the IT field. Among the related technologies, desktop virtualization has been applied to various commercial applications since it provides many advantages, such as lower maintenance and operation costs and higher utilization. However, the existing solutions offer a very limited performance for 3D graphics applications. Therefore, we propose a novel method in which rendering commands are not executed at the host server but rather are delivered to the client through the network and are executed by the client's graphics device. This method prominently reduces server overhead and makes it possible to provide a stable service at low cost. The results of various experiments prove that the proposed method outperforms all existing solutions.

Effect of the volumetric dimensions of a complete arch on the accuracy of scanners

  • Kim, Min-Kyu;Son, KeunBaDa;Yu, Beom-Young;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.6
    • /
    • pp.361-368
    • /
    • 2020
  • PURPOSE. The present study aimed to evaluate the accuracy of a desktop scanner and intraoral scanners based on the volumetric dimensions of a complete arch. MATERIALS AND METHODS. Seven reference models were fabricated based on the volumetric dimensions of complete arch (70%, 80%, 90%, 100%, 110%, 120%, and 130%). The reference models were digitized using an industrial scanner (Solutionix C500; MEDIT) for the fabrication of a computer-aided design (CAD) reference model (CRM). The reference models were digitized using three intraoral scanners (CS3600, Trios3, and i500) and one desktop scanner (E1) to fabricate a CAD test model (CTM). CRM and CTM were then superimposed using inspection software, and 3D analysis was conducted. For statistical analysis, one-way analysis of variance was used to verify the difference in accuracy based on the volumetric dimensions of the complete arch and the accuracy based on the scanners, and the differences among the groups were analyzed using the Tukey HSD test as a post-hoc test (α=.05). RESULTS. The three different scanners showed a significant difference in accuracy based on the volumetric dimensions of the complete arch (P<.05), but the desktop scanner did not show a significant difference in accuracy based on the volumetric dimensions of the complete arch (P=.808). CONCLUSION. The accuracy of the intraoral scanners was dependent on the volumetric dimensions of the complete arch, but the volumetric dimensions of the complete arch had no effect on the accuracy of the desktop scanner. Additionally, depending on the type of intraoral scanners, the accuracy differed according to the volumetric dimensions of the complete arch.