• Title/Summary/Keyword: 3D Curved Surface

Search Result 97, Processing Time 0.027 seconds

Root and Canal Morphology of Maxillary Primary Molar using CBCT and 3D CT (CBCT 및 3D CT를 활용한 상악 유구치 치근과 근관 형태)

  • Kim, Joon Hee;Kim, Hyuntae;Shin, Teo Jeon;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Song, Ji-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.4
    • /
    • pp.437-448
    • /
    • 2021
  • The purpose of this study is to analyze morphological characteristics of maxillary primary molar's root and root canal. 268 children aged 3 - 7 years (175 boys, 93 girls) who had CBCT (152 children) and 3D CT (116 children) taken in Seoul National University Dental Hospital from January 2006 to April 2020 were included. The number of roots and root canals were analyzed in 1002 teeth without any root resorption or periapical pathologies. Curvature, angulation, length of root and root canal, as well as cross-sectional shapes of the root canal were analyzed in 218 teeth. By using Mimics and 3-Matics software, volume, surface area, and volume ratio of root canal was analyzed in 48 teeth. More than half of maxillary primary molars have 3 roots and 3 root canals. The degree of symmetry of root canal type was about 0.63 (Cohen's kappa coefficient). The most frequent shape of roots and canals was linear in 1st primary molars and curved in 2nd primary molars. Angulation, length of root and root canals was the largest on palatal roots. Most teeth showed ovoid or round shapes at apex. The largest root canal volume, surface area, volume ratio was found in the palatal roots.

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

A Study on the Cutting Forces and Tool Deformation when Flat-ended Pocket Machining (평엔드밀 포켓가공시 절삭력과 공구변형에 관한 연구)

  • Choi, Sung-Yun;Kwon, Dae-Gyu;Park, In-Su;Wang, Duck-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.2
    • /
    • pp.28-33
    • /
    • 2017
  • Recently, the operation of precision pocket machining has been studied for the high speed and accuracy in industry to increase production and quality. Moreover, the demand for products with complex 3D free-curved surface shapes has increasing rapidly in the development of computer systems, CNC machining, and CAM software in various manufacturing fields, especially in automotive engineering. The type of aluminum (Al6061) that is widely used in aerospace fields was used in this study, and end-mill down cutting was conducted in fillet cutting at a corner with end-mill tools for various process conditions. The experimental results may demonstrate that the end mill cutter with four blades is more advantageous than that of the two blades on shape forming in the same condition precise machining conditions. It was also found that cutting forces and tool deformation increased as the cutting speed increased. When the tool was located at $45^{\circ}$ (four locations), the corner was found to conduct the maximum cutting force rather than the start point of the workpiece. The experimental research is expected to increase efficiency when the economical precision machining methods are required for various cutting conditions in industry.

Bactericidal Effect of a 275-nm UV-C LED Sterilizer for Escalator Handrails: Optimization of Optical Structure and Evaluation of Sterilization of Six Bacterial Strains

  • Kim, Jong-Oh;Jeong, Geum-Jae;Son, Eun-Ik;Jo, Du-Min;Kim, Myung-Sub;Chun, Dong-Hae;Kim, Young-Mog;Ryu, Uh-Chan
    • Current Optics and Photonics
    • /
    • v.6 no.2
    • /
    • pp.202-211
    • /
    • 2022
  • In the pasteurization of escalator handrails using ultraviolet (UV) sterilizers, a combination of light distribution and escalator speed has priority over other important factors. Furthermore, since part of the escalator handrail has a curved structure, proper design is needed to improve the sterilization rate on the surfaces touched by users. In this paper, two types of sterilizers satisfying these conditions are manufactured with 275-nm UV-C LEDs, after modeling the three-dimensional (3D) structure of an escalator handrail and simulating optical distributions of UV-C irradiation on the handrail's surface according to light-emitting diode (LED) positions and reflector variations in the sterilizers. Pasteurization experiments with the UV-C LED sterilizers are conducted on six types of gram-positive and gram-negative bacteria, with exposure times of 0.2, 5, and 15 s at an actual installation distance of 20 mm. The sterilization rates for the gram-positive bacteria are 10.63% to 27.94% at 0.2 s, 89.44% to 96.30% at 5 s, and 99.64% to 99.88% at 15 s. Those for the gram-negative bacteria are 57.70% to 77.63% at 0.2 s, 98.90% to 99.49% at 5 s, and 99.88% to 99.99% at 15 s. The power consumption of the UV-C LED sterilizer is about 8 W, which can be supplied by a self-generation module instead of an external power supply.

A STUDY ON IN VIVO AND IN VITRO AMALGAM CORROSION (아말감의 구강내 부식 및 인공 부식에 관한 연구)

  • Lim, Byong-Mok;Kwon, Hyuk-Choon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.1-33
    • /
    • 1997
  • The objective of this study was to analyze the in vitro and in vivo corrosion products of low and high copper amalgams. The four different types of amalgam alloy used in this study were Fine cut, Caulk spherical, Dispersalloy, and Tytin. After each amalgam alloy and Hg were triturated according to the directions of the manufacturer by means of the mechanical amalgamator(Amalgam mixer. Shinhung Co. Korea), the triturated mass was inserted into a cylindrical metal mold which was 12mm in diameter and 10mm in height. The mass was condensed by 150Kg/cm compressive force. The specimen was removed from the mold and aged at room temperature for about seven days. The standard surface preparation was routinely carried out by emery paper polishing under running water. In vitro amalgam specimens were potentiostatically polarized ten times in a normal saline solution at $37^{\circ}C$(potentiostat : HA-301. Hukuto Denko Corp. Japan). Each specimen was subjected to anodic polarization scan within the potential range -1700mV to+400mV(SCE). After corrosion tests, anodic polarization curves and corrosion potentials were obtained. The amount of component elements dissolved from amalgams into solution was measured three times by ICP AES(Inductive Coupled Plasma Atomic Emission Spectrometry: Plasma 40. Perkim Elmer Co. U.S.A.). The four different types of amalgam were filled in occlusal and buccal class I cavities of four human 3rd molars. After about five years the restorations were carefully removed after tooth extraction to preserve the structural details including the deteriorated margins. The occlusal surface, amalgam-tooth interface and the fractured surface of in vivo amalgam corrosion products were analyzed. In vivo and in vitro amalgam specimens were examined and analyzed metallographically by SEM(Scanning Electron Microscope: JSM 840. Jeol Co. Japan) and EDAX(Energy Dispersive Micro X-ray Analyser: JSM 840. Jeol Co. Japan). 1. The following results are obtained from in vitro corrosion tests. 1) Corrosion potentials of all amalgams became more noble after ten times passing through the in vitro corrosion test compared to first time. 2) After times through the test, released Cu concentration in saline solution was almost equal but highest in Fine cut. Ag and Hg ion concentration was highest in Caulk spherical and Sn was highest in Dispersalloy. 3) Analyses of surface corrosion products in vitro reveal the following results. a)The corroded surface of Caulk spherical has Na-Sn-Cl containing clusters of $5{\mu}m$ needle-like crystals and oval shapes of Sn-Cl phase, polyhedral Sn oxide phase. b)In Fine cut, there appeared to be a large Sn containing phase, surrounded by many Cu-Sn phases of $1{\mu}m$ granular shapes. c)Dispersalloy was covered by a thick reticular layer which contained Zn-Cl phase. d)In Tytin, a very thin, corroded layer had formed with irregularly growing Sn-Cl phases that looked like a stack of plates. 2. The following results are obtained by an analysis of in vivo amalgam corrosion products. 1) Occlusal surfaces of all amalgams were covered by thick amorphous layers containing Ca-P elements which were abraded by occlusal force. 2) In tooth-amalgam interface, Ca-P containing products were examined in all amalgams but were most clearly seen in low copper amalgams. 3) Sn oxide appeared as a polyhedral shape in internal space in Caulk spherical and Fine cut. 4) Apical pyramidal shaped Sn oxide and curved plate-like Sn-Cl phases resulted in Dispersalloy. 5) In Tytin, Sn oxide and Sn hydroxide were not seen but polyhedral Ag-Hg phase crystal appeared in internal space which assumed a ${\beta}_l$ phase.

  • PDF

Digital Restoration of Ring-Pommeled Sword by Using Technology of 3D Shape Information Processing (3차원 형상정보 처리기술을 이용한 환두대도의 디지털 원형복원)

  • Kim Young-Won;Jun Byung-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.4
    • /
    • pp.133-140
    • /
    • 2005
  • Culture Technology is the basic technology which produces cultural contents in a narrow sense. All nations do their best in order to create new contents which can form international and cultural sympathy. If a variety of contents are created by applying Korean proper cultural heritages, they will be creative and competitive internationally. Therefore, technology of original cultural restoration is an essential and crucial skill. In this paper, 'gilt bronze dragon-phoenix ring-pommeled sword', a cultural heritage of baekje age, will be restored to the original form digitally on the basis of three-dimensional shape-information processing technology and the scientifically analyzed data. First of all, data from three-dimensional scanning is revised using stuffing and smoothing methods after sampling, extracting characteristics, and align. Then, they are modeled in a curved surface with NURBS and B-Spline. Secondly, textures are edited by estimating the color of components and the quality of materials, and then they are mapped. Original form model which was made was revised and corrected by specialists' examinations. The digitally revised ring-pommeled sword was combined with information technology, and it can be used to revise damaged cultural heritages by constructing formal database of ring-pommeled sword with regard to age, area and type. It can be also used as educational contents in archaeology or preservation science and cultural contents such as movies, broadcasts, games, animations and so on.

  • PDF

Geodesic Shape Finding Algorithm for the Pattern Generation of Tension Membrane Structures (막구조물의 재단도를 위한 측지선 형상해석 알고리즘)

  • Lee, Kyung-Soo;Han, Sang-Eul
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.1
    • /
    • pp.33-42
    • /
    • 2010
  • Patterning with a geodesic line is essential for economical or efficient usage of membrane materialsin fabric tension membrane structural engineering and analysis. The numerical algorithm to determine the geodesic line for membrane structures is generally classified into two. The first algorithm finds a non-linear shape using a fictitious geodesic element with an initial pre-stress, and the other algorithm is the geodesic line cutting or searching algorithm for arbitrarily curved 3D surface shapes. These two algorithms are still being used only for the three-node plane stress membrane element, and not for the four-node element. The lack of a numerical algorithm for geodesic lines with four-node membrane elements is the main reason for the infrequent use of the four-node membrane element in membrane structural engineering and design. In this paper, a modified numerical algorithm is proposed for the generation of a geodesic line that can be applied to three- or four-node elements at the same time. The explicit non-linear static Dynamic Relaxation Method (DRM) was applied to the non-linear geodesic shape-finding analysis by introducing the fictitiously tensioned 'strings' along the desired seams with the three- or four-node membrane element. The proposed algorithm was used for the numerical example for the non-linear geodesic shape-finding and patterning analysis to demonstrate the accuracy and efficiency, and thus, the potential, of the algorithm. The proposed geodesic shape-finding algorithm may improve the applicability of the four-node membrane element for membrane structural engineering and design analysis simultaneously in terms of the shape-finding analysis, the stress analysis, and the patterning analysis.