• Title/Summary/Keyword: 3D Analysis System

Search Result 3,970, Processing Time 0.042 seconds

Dynamic Characteristics Analysis of 3D Conveyor System Linear Induction Motor for Control Algorithm Developments (제어알고리즘 개선을 위한 3차원 반송 시스템 선형유도전동기의 동특성 해석)

  • Jeon, Su-Jin;Lee, Jung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.514-518
    • /
    • 2007
  • It is necessary to modify the state-of-the-art of speed control theory because of the phase asymmetry in the Linear Induction Motor (LIM)and for the constant speed control of mover using single vector control inverter system, it is important that primary stack is located in appropriated intervals in the 3D conveyer system using LIM. The dynamic characteristic analysis method of the vector controlled LIM using coupled FEM and control algorithm taking into account the movement is proposed. The focus of this paper is the analysis relative to selecting primary stack intervals in order to constant speed control in the 3D conveyer system using LIM.

Design of Interface between 3D Object Model and Structure Analysis Program (3D 객체 모델과 구조해석 프로그램의 인터페이스 설계)

  • Park, Jae-Geun;Kim, Min-Hee;Lee, Kwang-Myong;Choi, Jung-Ho;Shin, Hyun-Mock
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.3
    • /
    • pp.247-252
    • /
    • 2008
  • Recently, the virtual construction system in which project participants efficiently share and control the information throughout the life-cycle of construction project using 3D object models is being developed all over the world. In this paper, a design of interface between 3D object model of structures and structural analysis system that is essential for the analysis and design of civil structures in the virtual space is treated. The relation parametric modeling technique that is needed to make the 3D object models and the construction method of product breakdown structure(PBS) that considers the several parameters for the structural analysis are presented. PBS is built so that it is possible to extract needed attribute information from 3D object model and to apply it to the structural analysis. Design methodology for interface program is proposed that several numerical values determined by the cooperative work same as structural analysis are delivered to 3D object models without additional work. An interface program between 3D object models and structural analysis system developed based on the proposed method would be effectively used to develop virtual construction system.

IMGT Unique Numbering for Standardized Contact Analysis of Immunoglobulin/antigen and T cell receptor/peptide/MHC Complexes

  • Kaas, Quentin;Chiche, Laurent;Lefrane, Marie-Paule
    • Proceedings of the Korean Society for Bioinformatics Conference
    • /
    • 2005.09a
    • /
    • pp.209-214
    • /
    • 2005
  • Immunoglobulins (IG) , T cell receptors (TR) and major histocompatibility complex (MHC) are major components of the immune system. Their experimentally determined three-dimensional (3D) structures are numerous and their retrieval and comparison is problematic. IMGT, the international ImMunoGeneTics information system$^{\circledR}$(http://imgt.cines.fr), has devised controlled vocabulary and annotation rules for the sequences and 3D structures of the IG TR and MHC. Annotated data from IMGT/3D sructure-DB, the IMGT 3D structure database, are used in this paper to compare 3D structure of the domains and receptor, and to characterize IG/antigen, peptide/MHC and TR/peptide/MHC interfaces. The analysis includes angle measures to assess receptor flexibility, structural superimposition and contact analysis. Up-to-date data and analysis results are available at the IMGT Web site, http://imgt.cines.fr.

  • PDF

A Study on the Upper Body Range of Motion (Using a 3-D Motion Anlaysis System) about Korean Adults (한국 성인 남자의 상체 동작범위 연구 - 3D 동작분석 장치를 이용하여 -)

  • 박길순;유신아
    • The Research Journal of the Costume Culture
    • /
    • v.8 no.4
    • /
    • pp.587-601
    • /
    • 2000
  • The purpose of this study : 1. The total 56 range measurements of active dynamic motion of 40 subjects (20's and 30's) were measured using 3-D dynamic motion analysis system. 2. Various comparisons were performed for the right and left side, male, age groups (20's, 30's, and 40's ∼ 60's) using previous studies. The results were compared with the other studies in the aspects of age. In this study, the 3-D motion analysis system based on photogrammetry was established and used to analyze the human's motion and posture. The system consists of VICON 140, data acquisition system, and data analysis program (KRISSMAS). The result of this study were as follows : 1. Comparing 20's with 30's the result shows that 30's have larger ROM at some joints, which is inconsistent with the previous result. The reason is that female subjects in 20's were improperly sampled according to the representatives of anthropometry characteristics. 2. There are significant differences in some joints related with age. 20's male subjects have more flexible joints in the neck while 30's male subjects have more flexibility in their shoulder joint and elbow joint. But most of the significances were not high (p〈0.05). The prediction that the right side of Korean bodies would be more flexible was not a good hypothesis. And the joints flexibilities are not correlated with Rohrer's Index.

  • PDF

DESIGN AND IMPLEMENTATION OF FEATURE-BASED 3D GEO-SPATIAL RENDERING SYSTEM USING OPENGL API

  • Kim Seung-Yeb;Lee Kiwon
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.321-324
    • /
    • 2005
  • In these days, the management and visualization of 3D geo-spatial information is regarded as one of an important issue in GiS and remote sensing fields. 3D GIS is considered with the database issues such as handling and managing of 3D geometry/topology attributes, whereas 3D visualization is basically concerned with 3D computer graphics. This study focused on the design and implementation for the OpenGL API-based rendering system for the complex types of 3D geo-spatial features. In this approach 3D features can be separately processed with the functions of authoring and manipulation of terrain segments, building segments, road segments, and other geo-based things with texture mapping. Using this implementation, it is possible to the generation of an integrated scene with these complex types of 3D features. This integrated rendering system based on the feature-based 3D-GIS model can be extended and effectively applied to urban environment analysis, 3D virtual simulation and fly-by navigation in urban planning. Furthermore, we expect that 3D-GIS visualization application based on OpenGL API can be easily extended into a real-time mobile 3D-GIS system, soon after the release of OpenGLIES which stands for OpenGL for embedded system, though this topic is beyond the scope of this implementation.

  • PDF

A Study on the Analysis and Comparison of DC Suite and CLO3D

  • Jang, Heekyung;Chen, Jianhui
    • Journal of Fashion Business
    • /
    • v.21 no.6
    • /
    • pp.87-105
    • /
    • 2017
  • In the fashion industry, 2D apparel CAD technology has already matured and various 3D apparel CADs have been introduced and are available for users. In the fourth industrial revolution era, the 3D apparel technology will be highlighted, and the research of 3D apparel CAD will be much more emphasized upon. Currently, various 3D apparel CAD have been developed and commercialized due to the rapid development of technology. However, in reality, the analysis and discussions about its problems and the improvements for clothing from a user's perspective have not been carried out yet. The purpose of this study was to provide the reference information about 3D apparel CAD for users by studying and comparing the characteristics of 3D apparel CAD. The 3D apparel CAD, DC Suite and CLO3D were selected for technical comparative study. The 3D apparel CAD mainly includes 3D body system, garment pattern system and garment simulation system and so on. It was compared and analyzed; the problem was presented, and the directions of improvement were put forth.

A Study on the 3-D Deformation Analysis for Safety Diagnosis of Bridges (교량의 안전진단을 위한 3차원 변형해석에 관한 연구)

  • 강준묵;윤희천;배상호
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.13 no.1
    • /
    • pp.69-76
    • /
    • 1995
  • This study is the 3-D precision deformation measurement of a bridge, obtain results of precision control points by GPS and 3-D measurement system and develope efficientlty technices which can solve precision 3-D analysis by CRP In the result, we could overcome the problems of former control point measurement in the way of the combination system of GPS and 3-D measurement system to positioning decision of reference points and control points. Then we could symplify old measurement process on the 3-D deformation analysis of a linear structure and complement parted analysis fault of measurement instrument.

  • PDF

Comparison of UNDEX Whipping Response of Hull Girder according to Modeling Methods (해석모델링 방법에 따른 선체거더의 수중폭발 휘핑응답 비교)

  • Kwon, Jeong-Il;Chung, Jung-Hoon;Lee, Sang-Gab
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.6 s.144
    • /
    • pp.631-636
    • /
    • 2005
  • One and three dimensional whipping response analyses of a naval surface combatant subjected to an underwater explosion bubble pulse were carried out to compare the efficiency and accuracy according to the modeling methods. In 1-D analysis, program UNDEXWHIP developed by KIMM was used, which is based on the thin-walled Timoshenko's beam theory and on the modal analysis method using wetted vibratory modes of the hull girder. In 3-D analysis, three finite element models were suggested using LS-DYNA/USA code, such as 3-D beam model considering geometric shape of wetted side shell, coarse and fine 3-D F.E. models. Through the comparison of results from the 1-D and 3-D analyses, it could be confirmed that 1-D analysis result is in good agreement with 3-D analysis ones, and that fine 3-D F.E. model, shock analysis one, is also used both in the shock response and whipping response analyses for the analyst effort and time savings.

A Finite Element Analysis of Elastomeric O-ring Performance and Structure when subjected to Foreign Objects (유한요소해석을 이용한 이물질이 고무오링과 구조물에 미치는 영향과 성능 연구)

  • Pack, Inseok;Rhee, Heejang;Lee, Seoksoon
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.1
    • /
    • pp.28-34
    • /
    • 2017
  • Elastomeric o-ring performance and structure when subjected to a foreign object is studied using finite element analysis (FEA). Elastomeric o-rings have been studied using 2D analysis for a long time. Contact pressure is an important factor in o-ring design. When contact pressure is lower than applied pressure, leaking, vibration, and noise can occur; resulting in decreased output. In this study, we compared 2D and 3D analyses of elastomeric o-rings. Similar results were shown for 2D and 3D contact pressure. However, when an o-ring encounters foreign object matter, 3D analysis is required because contact pressure in every direction needs to be considered. We determined the influence of foreign matter on o-ring performance and structure by analyzing 10 cases with different clearances in a 3D model. Therefore, an o-ring encountering foreign object matter must be analyzed in 3D with the result included in the o-ring design.

Analysis on mandibular movement using the JT-3D system (JT-3D system을 이용한 하악의 운동 분석)

  • Song, Joo-Hun;Kim, Ryeo-Woon;Byun, Jae-Joon;Kim, Hee-Jung;Heo, Yu-ri;Lee, Gyeong-Je
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.80-87
    • /
    • 2020
  • Purpose: This study aims to measure the mandibular movement using JT-3D system and provide a range of mandibular movement that can serve as a good reference for diagnosing the temporomandibular disorder. Materials and Methods: This study was conducted in 60 young male and female adults. The maximum opening and closing movement was recorded using JT-3D system, and by regarding 5 times of repetitive movement as 1 cycle of movement, total 3 cycles of movement were recorded. During the maximum opening, vertical position of lower jaw, antero-posterior position, lateral deflection position, and maximum opening distance were recorded. To evaluate the reproducibility of JT-3D system, statistical analysis were conducted (α = 0.05). Results: During the maximum opening, the average value appeared at 31.56 mm vertically and 24.42 mm rearwardly, lateral deflection position 0.72 mm, and maximum opening distance 40.32 mm. There was no statistical significance in all measured values for three cycles of movement recorded with JT-3D system (P > 0.05). Conclusion: During the maximum opening, the average value appeared at 0.72 mm in lateral deflection position and the maximum opening distance at 40.32 mm, and the analysis on the maximum opening of lower jaw using JT-3D system showed sufficiently reproducible results.