• Title/Summary/Keyword: 3D 측정

Search Result 6,578, Processing Time 0.038 seconds

A Study on Development of the 3D Modeling System for Earthwork Environment (토공 작업환경의 3차원 모델링 시스템 개발에 관한 연구)

  • Yoo, Hyun-Seok;Chae, Myung-Jin;Kim, Jung-Yeol;Cho, Moon-Young
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.977-982
    • /
    • 2007
  • There have been many efforts in automatic object recognition using computing technologies. Especially in the development of automated construction equipment, automatic object recognition is very important issue for the proper equipment maneuvering. 3D laser scanning, which uses (time-of-flight) method to construct the 3-dimensional information, is applied to the civil earth work environment for its high accuracy, quick data collection, and object recognition capability that will be developed by the authors in the future. The 3D earth model is also used as a fundamental information for intelligent earth work task planning. This paper presents the analysis of the 3D laser scanner market and selection of the most optimum 3D scanner for the intelligent earth work planning. As well as the hardware configuration for the automated 3D earth modeling is developed but also the software structure and detailed user interface are designed in this research. In addition, it is presented in this paper that the accuracy comparison test between TotalStation(R) which is a traditional survey tool and ScanStation(R). The accuracy test is done by relative distance measurement using known targets.

  • PDF

Evaluation of Stability of Double Threaded Implant-Emphasis on Initial Stability Using Osstell MentorTM; Part I (이중나사산 임플란트의 안정성에 대한 평가 - 오스텔 멘토를 이용한 초기 안정성 ; PART I)

  • Kim, Si-Yeob;Kim, Byung-Kook;Heo, Jin-Ho;Lee, Ju-Youn;Jeong, Chang-Mo;Kim, Yong-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.4
    • /
    • pp.327-336
    • /
    • 2007
  • Purpose This study was planned to compare and evaluate the stability of implant using $Osstell^{TM}$ and Osstell $Mentor^{TM}$. Material and methods Artificial bone and RBM(resorbable blasting media) surface blasted implants(Osstem US II, SS II implants - diameter: 4mm, length: 13mm) were used. To measure the stability of installed implants, $Osstell^{TM}$ and Osstell $Mentor^{TM}$ were used. In the first experiment, five implants were installed in D1(external type implants) and D3(internal type implants). In the second experiment, 4 internal type implants were divided in two groups and installed in D1 artificial bone with different depth. In the third experiment, two external implants were installed in D1 and D3 artificial bone each and two internal implants were installed in D1 and D3 artificial bone. In all groups, their stability were measured by $Osstell^{TM}$ and Osstell $Mentor^{TM}$. Results In all groups, $Osstell^{TM}$ and Osstell $Mentor^{TM}$ both showed reliable measurement values. The value difference between $Osstell^{TM}$ and Osstell $Mentor^{TM}$ was observed but the difference was small and clinically acceptable. Conclusion These results suggest that the use of Osstell $Mentor^{TM}$ has clinical relevance in the assessment of implant stability.

Cortical Thickness Estimation Using DIR Imaging with GRAPPA Factor 2 (DIR 영상을 이용한 피질두께 측정: GRAPPA 인자 2를 이용한 비교)

  • Choi, Na-Rae;Nam, Yoon-Ho;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.56-63
    • /
    • 2010
  • Purpose : DIR image is relatively free from susceptibility artifacts therefore, DIR image can make it possible to reliably measure cortical thickness/volume. One drawback of the DIR acquisition is the long scan time to acquire the fully sampled 3D data set. To solve this problem, we applied a parallel imaging method (GRAPPA) and verify the reliability of using the volumetric study. Materials and methods : Six healthy volunteers (3 males and 3 females; age $25.33{\pm}2.25$ years) underwent MRI using the 3D DIR sequence at a 3.0T Siemens Tim Trio MRI scanner. GRAPPA simulation was performed from the fully sampled data set for reduction factor 2. Data reconstruction was performed using MATLAB R2009b. Freesurfer v.4.3.0 was used to evaluate the cortical thickness of the entire brain, and to extract white matter information from the DIR image, Analyze 9.0 was used. The global cortical thickness estimated from the reconstructed image was compared with reference image by using a T-test in SPSS. Results : Although reduced SNR and blurring are observed from the reconstructed image, in terms of segmentation the effect was not so significant. The volumetric result was validated that there were no significant differences in many cortical regions. Conclusion : This study was performed with DIR image for a volumetric MRI study. To solve the long scan time of 3D DIR imaging, we applied GRAPPA algorithm. According to the results, fast imaging can be done with reduction factor 2 with little loss of image quality at 3.0T.

Analysis of Display Fatigue induced by HMD-based Virtual Reality Bicycle (HMD 기반 가상현실 자전거의 영상피로 분석)

  • Kim, Sun-Uk;Han, Seung Jo;Koo, Kyo-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.692-699
    • /
    • 2017
  • The purpose of this study is to investigate the display fatigue quantitatively when operating 2D and HMD-based 3D VR bicycles. Though it is generally accepted that the display fatigue induced by 3D VR is greater than that induced by 2D VR, there have been few studies which attempted to measure the display fatigue scientifically. The subjective degree of cybersickness and quantitative flicker fusion frequency (FFF) were measured in twenty subjects (Male 10, Female 10) before and after they operated 2D and 3D VR bicycles for 5 min. Two dependent variables affected by the 2D and 3D VR displays were analyzed and compared statistically based on scientific evidence and research. This study showed that 3D VR resulted in a significantly higher cybersickness rate and a significant lower FFF rate than 2D VR. Given the current propensity to couple VR techniques with exercise equipment, it seems appropriate to verify the general beliefs through scientific methods and experimental measures such as the FFF and cybersickness questionnaires.

Design of a 24 GHz Power Amplifier Using 65-nm CMOS Technology (65-nm CMOS 공정을 이용한 24 GHz 전력증폭기 설계)

  • Seo, Dong-In;Kim, Jun-Seong;Cui, Chenglin;Kim, Byung-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.10
    • /
    • pp.941-944
    • /
    • 2016
  • This paper proposes 24 GHz power amplifier for automotive collision avoidance and surveillance short range radar using Samsung 65-nm CMOS process. The proposed circuit has a 2-stage differential power amplifier which includes common source structure and transformer for single to differential conversion, impedance matching, and power combining. The measurement results show 15.5 dB maximum voltage gain and 3.6 GHz 3 dB bandwidth. The measured maximum output power is 13.1 dBm, input $P1_{dB}$ is -4.72 dBm, output $P1_{dB}$ is 9.78 dBm, and maximum power efficiency is 17.7 %. The power amplifier consumes 74 mW DC power from 1.2 V supply voltage.

Automatic Registration Method for Multiple 3D Range Data Sets (다중 3차원 거리정보 데이타의 자동 정합 방법)

  • 김상훈;조청운;홍현기
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.12
    • /
    • pp.1239-1246
    • /
    • 2003
  • Registration is the process aligning the range data sets from different views in a common coordinate system. In order to achieve a complete 3D model, we need to refine the data sets after coarse registration. One of the most popular refinery techniques is the iterative closest point (ICP) algorithm, which starts with pre-estimated overlapping regions. This paper presents an improved ICP algorithm that can automatically register multiple 3D data sets from unknown viewpoints. The sensor projection that represents the mapping of the 3D data into its associated range image is used to determine the overlapping region of two range data sets. By combining ICP algorithm with the sensor projection constraint, we can make an automatic registration of multiple 3D sets without pre-procedures that are prone to errors and any mechanical positioning device or manual assistance. The experimental results showed better performance of the proposed method on a couple of 3D data sets than previous methods.

Consideration of the Effect of Artifact during the Image Guided Radiation Therapy Using the Fiducial Marker (영상 유도 방사선치료 시 Fiducial Marker의 Artifact에 관한 연구)

  • Kim, Jong-Min;Kim, Dae-Sup;Back, Geum-Mun;Kang, Tae-Yeong;Hong, Dong-Ki;Yun, Hwa-Yong;Kwon, Kyeong-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Purpose: The effect of artifact was analyzed, which occurs from fiducial marker during the liver Image Guided Radiation Therapy (IGRT) using the fiducial marker. Materials and Methods: The size of artifact of fixed fiducial marker and length of mobile fiducial marker locus were measured using the On-Board Imager system (OBI) and CT simulator, and 2D-2D matching and 3D-3D matching were carried out, respectively, and at this time, the coordinates transition value of couch was analyzed. Results: The measurement of fixed fiducial marker artifact size indicated CT 4.90, 8.10, 12.90, 19.70 mm and OBI 5.60, 10.60, 14.70, 29.40 mm based on the reference CT slice thickness of 1.25, 2.50, 5.00, and 10.00 mm. Meanwhile, the measurement of mobile fiducial marker locus length indicated CT 42.00, 43.10, 46.50 mm, and OBI 43.40, 46.00, 49.30 mm. The coordinates transition of 1.00, 2.00, and 8.00 mm occurred between 2D-2D matching and 3D-3D matching. Conclusion: It was confirmed that the therapy error increased during IGRT due to the influence of artifact when CT slice thickness increased. Thus, it may be desirable to acquire the image less than 2.50 mm in slice thickness when IGRT is implemented using the fiducial marker.

  • PDF

Evaluation of Visual Responses in Viewing a 3D Image (3D 영상 시청 시 시각반응의 평가)

  • Lee, Mu-Hyuk;Son, Jeong-Sik;Kim, Jaedo;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.165-170
    • /
    • 2012
  • Purpose: The aim of this study was to measure and evaluate changes of visual responses in viewing a 2D and 3D (three-dimensional) image. Methods: The subjects were 44 college students aged 19 to 25 years with normal binocular vision. The visual responses measured were CA/C (convergence accommodation/convergence) ratio, convergence-induced PD(interpupillary distance), accommodative responses, perceived distance in viewing a 3D image. Results: Convergence and accommodative responses in viewing the 3D image were significantly larger (p<0.05) than in 2D. A moderate positive correction was found between CA/C ratio and accommodative response (r = 0.477, p = 0.001). It was indicated that smaller PD had larger depth perception. Convergence in viewing the 3D image was significantly larger (p<0.05) than that at cognitive distance. Conclusions: The visual fatigue may be more intense in larger CA/C ratio and smaller PD when viewing 3D images.

An Improved Method of LCD Gamma-nonlinearity Error Reduction in Digital Fringe Projection for Optical Three-dimensional Shape Measurement (3차원 광학 측정을 위한 디지털 프린지 투사에 있어서 LCD 비선형 감마 에러 개선 방법)

  • Kim, Woo Sung
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.3
    • /
    • pp.134-141
    • /
    • 2020
  • Optical three-dimensional (3D) measurement systems based on digital fringe projection are used in many contactless measurement applications. The system which can measure a dozen micrometers uses a liquid-crystal display (LCD) as the projection unit for generating a digital fringe pattern, because a flexible fringe pattern can be easily made by computer software. According to the gamma nonlinearity of the LCD projection unit, the digital fringe projection error on the object affects the accuracy of 3D object measurement. An improved method of LCD gamma-nonlinearity error reduction is proposed, by using the inverse function of the intensity transfer function to improve the accuracy. The improvement due to the proposed method is shown by measuring the difference in precision between a computer-generated sine wave and a camera-obtained sine wave for a standard semiconductor specimen.

A Study of Thermal Imaging Noise Reduction based on 3D Noise Reduction Method (3D Noise Reduction 방법에 기반한 열 영상 잡음 감쇠에 관한 연구)

  • Kim, Myung-kwang;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.160-163
    • /
    • 2009
  • 최근 적외선 열 영상의 유용함이 발표되어감에 따라 이 기술에 대한 이해와 도입폭이 점진적으로 넓혀져 가고 있다. 국내는 물론 세계적으로 많은 제조, 개발 관련 업체들이 생겨나고 있으며, 업체들의 기술이 발전함에 따라 높은 온도 분해능과 해상도는 물론, 시스템 전체의 크기가 휴대가 가능할 정도로 소형화 되어가고 있는 추세이다. 이러한 열 영상 카메라에서 중요한 역할을 하는 적외선 열 감지 센서에서는 주변 온도, 대상 온도, 표면 온도 등의 측정 오차 및 열상 측정 소자의 온도, Bias 불안정 등의 매우 다양한 원인으로 인한 잡음이 발생하기 쉽다. 이러한 다양한 잡음의 감소는 해상도 및 온도 분해능의 향상과 직결되므로, 잡음을 줄이기 위한 많은 연구가 도처에서 행해지고 있다. 본 논문은 이러한 노력의 일환으로써 각각의 잡음 원인을 규명하지 않고 최종 열 영상 출력물에서 인접 프레임들의 비교, 혼합 하여 제거하는 3D Noise Reduction 기술을 이용해 노이즈를 감쇠하는 방법에 대해 연구하였다.

  • PDF