• Title/Summary/Keyword: 3D 기술

Search Result 8,898, Processing Time 0.053 seconds

Evaluation of Image Quality Change by Truncated Region in Brain PET/CT (Brain PET에서 Truncated Region에 의한 영상의 질 평가)

  • Lee, Hong-Jae;Do, Yong-Ho;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.68-73
    • /
    • 2015
  • Purpose The purpose of this study was to evaluate image quality change by truncated region in field of view (FOV) of attenuation correction computed tomography (AC-CT) in brain PET/CT. Materials and Methods Biograph Truepoint 40 with TrueV (Siemens) was used as a scanner. $^{68}Ge$ phantom scan was performed with and without applying brain holder using brain PET/CT protocol. PET attenuation correction factor (ACF) was evaluated according to existence of pallet in FOV of AC-CT. FBP, OSEM-3D and PSF methods were applied for PET reconstruction. Parameters of iteration 4, subsets 21 and gaussian 2 mm filter were applied for iterative reconstruction methods. Window level 2900, width 6000 and level 4, 200, width 1000 were set for visual evaluation of PET AC images. Vertical profiles of 5 slices and 20 slices summation images applied gaussian 5 mm filter were produced for evaluating integral uniformity. Results Patient pallet was not covered in FOV of AC-CT when without applying brain holder because of small size of FOV. It resulted in defect of ACF sinogram by truncated region in ACF evaluation. When without applying brain holder, defect was appeared in lower part of transverse image on condition of window level 4200, width 1000 in PET AC image evaluation. With and without applying brain holder, integral uniformities of 5 slices and 20 slices summation images were 7.2%, 6.7% and 11.7%, 6.7%. Conclusion Truncated region by small FOV results in count defect in occipital lobe of brain in clinical or research studies. It is necessary to understand effect of truncated region and apply appropriate accessory for brain PET/CT.

  • PDF

Phantom Study of the Mutual Influences Between 18F-FDG and 99mTcO4- on the Same Day (18F-FDG와 99mTcO4-를 이용한 당일 검사 시 상호 영향에 대한 Phantom 연구)

  • Ham, Jun Cheol;Park, Min Soo;Bahn, Young Kag;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.68-72
    • /
    • 2014
  • Purpose The nuclear medicine examination, there is a difficulty to carry out the inspection of both on the day of residual isotope due to the half-life. In this study, by studying the mutual influence and $^{18}F$-FDG of $^{99m}TcO_4{^-}$, I would like to explain the matters to be considered in the case of performing the same day. Materials and Methods With the NEMA-1994 Phantom, and experiments were performed 3 times. Create a 1: 4 Background ratio HOT and the $^{99m}TcO_4{^-}$ The first experiment: After underwent SPECT in INFINIA (GE Healthcare, MI, USA), and were injected with $^{18}F$-FDG 37 MBq in the Background area, 13 once for 60 minutes under the same conditions was time Scan. Create a 1: 4 Background ratio HOT and the $^{18}F$-FDG second is: The Scan in PET/CT Discovery 600 (GE Healthcare, MI, USA), and 148 MBq after injection $^{99m}TcO_4{^-}$ the Background area, once for 60 minutes, 6 under the same conditions was time Scan. Create a 1: 4 Background ratio HOT and the $^{18}F$-FDG experiments las, increments of 296 MBq and 148 MBq the 1 Bed Scan after $^{99m}TcO_4{^-}$, was 1 Bed Scan under the same conditions. Non BKG area and HOT, I was measured comparing the Total Counts and SNR or CNR. Results Showed a significant difference in the ratio CNR of enforcement during SPECT $^{18}F$-FDG is, (p>0.05). The $^{99m}TcO_4{^-}$ was no significant difference between the SNR ratio of PET / CT at the time of the effective date (p<0.05). I got the results $^{99m}TcO_4{^-}$ that reduce the Total Counts of PET / CT scan. Conclusion If you make a PET / CT scan, may affect the test using the $^{99m}TcO_4{^-}$ up to 12 hours, when it is performed before the $^{99m}TcO_4{^-}$, does not affect the SNR and SUV, PET / CT scan I reduced the detection efficiency. The inspection of day, we'd like to recommend a way to complement the detection efficiency to increase the inspection time of PET / CT in move forward the inspection using the $^{99m}TcO_4{^-}$.

  • PDF

A Study on the Compatibility of Korean Temperature Guidelines for Stockpile Material Environmental Test (저장물자 환경시험을 위한 한국적 온도기준 적합성 연구)

  • Lee, Il Ro;Byun, Kisik;Cho, Sung-Yong;Kim, Kyung Pil;Park, Jae Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.187-194
    • /
    • 2020
  • The T&E (Test and Evaluation) results were applied for a judgment basis to decide the developmental process of system engineering for efficient weapon system R&D (Research and Development). During the OT&E (Operational Test and Evaluation) and DT&E (Development Test and Evaluation), an environmental test is essential for weapon system development owing to their highly exposed operational conditions. Based on the MIL-STD-810, MIL-HDBK-310, and AECTP 200, the ROK armed forces recommended operating temperatures for the ROK weapon system and applied this to the DT&E and OT&E. This study examined the compatibility of Korean temperature guidelines for stockpile material considering recent climate change. Moreover, this study analyzed the data from hourly measured temperatures on 101 observatories during 60 years, from 1960 to 2020, and percentage (0.5%, 1%, 5%, and 10%) and the 𝜎 (3𝜎, 2𝜎, and 1𝜎) frequency of occurrence on rigorous hot (August) and cold (January) periods, respectively. The results indicate that the highest temperature was 41℃, and the 0.5% frequency of occurrence was 37.0℃. In the case of the cold period, the lowest temperature was -32.6℃ and the 0.5% frequency of occurrence was -21.1℃. By considering the previously recommended operating temperature range for a general ground system, -30 ~ 40℃, regional operation probability is recognized 99.999%. Despite the recent abnormal climate change from global warming, the Korean temperature guidelines are compatible with the stockpile material environmental test.

Seismic Data Processing and Inversion for Characterization of CO2 Storage Prospect in Ulleung Basin, East Sea (동해 울릉분지 CO2 저장소 특성 분석을 위한 탄성파 자료처리 및 역산)

  • Lee, Ho Yong;Kim, Min Jun;Park, Myong-Ho
    • Economic and Environmental Geology
    • /
    • v.48 no.1
    • /
    • pp.25-39
    • /
    • 2015
  • $CO_2$ geological storage plays an important role in reduction of greenhouse gas emissions, but there is a lack of research for CCS demonstration. To achieve the goal of CCS, storing $CO_2$ safely and permanently in underground geological formations, it is essential to understand the characteristics of them, such as total storage capacity, stability, etc. and establish an injection strategy. We perform the impedance inversion for the seismic data acquired from the Ulleung Basin in 2012. To review the possibility of $CO_2$ storage, we also construct porosity models and extract attributes of the prospects from the seismic data. To improve the quality of seismic data, amplitude preserved processing methods, SWD(Shallow Water Demultiple), SRME(Surface Related Multiple Elimination) and Radon Demultiple, are applied. Three well log data are also analysed, and the log correlations of each well are 0.648, 0.574 and 0.342, respectively. All wells are used in building the low-frequency model to generate more robust initial model. Simultaneous pre-stack inversion is performed on all of the 2D profiles and inverted P-impedance, S-impedance and Vp/Vs ratio are generated from the inversion process. With the porosity profiles generated from the seismic inversion process, the porous and non-porous zones can be identified for the purpose of the $CO_2$ sequestration initiative. More detailed characterization of the geological storage and the simulation of $CO_2$ migration might be an essential for the CCS demonstration.

The Understanding and Application of Noise Reduction Software in Static Images (정적 영상에서 Noise Reduction Software의 이해와 적용)

  • Lee, Hyung-Jin;Song, Ho-Jun;Seung, Jong-Min;Choi, Jin-Wook;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.54-60
    • /
    • 2010
  • Purpose: Nuclear medicine manufacturers provide various softwares which shorten imaging time using their own image processing techniques such as UlatraSPECT, ASTONISH, Flash3D, Evolution, and nSPEED. Seoul National University Hospital has introduced softwares from Siemens and Philips, but it was still hard to understand algorithm difference between those two softwares. Thus, the purpose of this study was to figure out the difference of two softwares in planar images and research the possibility of application to images produced with high energy isotopes. Materials and Methods: First, a phantom study was performed to understand the difference of softwares in static studies. Various amounts of count were acquired and the images were analyzed quantitatively after application of PIXON, Siemens and ASTONISH, Philips, respectively. Then, we applied them to some applicable static studies and searched for merits and demerits. And also, they have been applied to images produced with high energy isotopes. Finally, A blind test was conducted by nuclear medicine doctors except phantom images. Results: There was nearly no difference between pre and post processing image with PIXON for FWHM test using capillary source whereas ASTONISH was improved. But, both of standard deviation(SD) and variance were decreased for PIXON while ASTONISH was highly increased. And in background variability comparison test using IEC phantom, PIXON has been decreased over all while ASTONISH has shown to be somewhat increased. Contrast ratio in each spheres has also been increased for both methods. For image scale, window width has been increased for 4~5 times after processing with PIXON while ASTONISH showed nearly no difference. After phantom test analysis, ASTONISH seemed to be applicable for some studies which needs quantitative analysis or high contrast, and PIXON seemed to be applicable for insufficient counts studies or long time studies. Conclusion: Quantitative values used for usual analysis were generally improved after application of the two softwares, however it seems that it's hard to maintain the consistency for all of nuclear medicine studies because result images can not be the same due to the difference of algorithm characteristic rather than the difference of gamma cameras. And also, it's hard to expect high image quality with the time shortening method such as whole body scan. But it will be possible to apply to static studies considering the algorithm characteristic or we can expect a change of image quality through application to high energy isotope images.

  • PDF

Comparison of Blood Glucose Level in Pancreatic Cancer on $^{18}F$-FDG PET (췌장암 환자의 양전자방출단층촬영(PET) 검사 시 혈당치와 영상에 관한 분석)

  • Oh, Shin-Hyun;Lee, Seung-Jae;Park, Hoon-Hee;Park, Yong-Sung;Kang, Chun-Goo;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.65-69
    • /
    • 2011
  • Purpose: Normal pancreas has low uptake rate in $^{18}F$-FDG PET scan. However, it is possible to diagnose malignancy of pancreatic cancer which has high uptake rate. Many studies approve a high prevalence of diabetes in pancreatic cancer and if the blood glucose level (BGL) is over the normal range, FDG uptake will be decreased and there will be inconvenience for patients from the delay time to reduce the high BGL or could cause difficulty to arrange the schedule. Therefore, we studied the relation of BGL and image quality in pancreatic cancer on PET. Materials and Methods: A hundred patients had PET scan. The prevalence of pancreatic cancer and diabetes were evaluated using SPSS ver. 17. The fasting BGL of patients were examined and sorted as diabetes mellitus (DM) group and Non-DM group. For the evaluation, patients were divided into 3 groups (Non-DM, DM; BGL${\geq}7.0mmol/L$, and DM; BGL<7.0 mmol/L). The ROI was drown on Liver and Lung for the PET imaging analysis. Results: Fifty three male and forty seven female were in the patients. The average age was $60.1{\pm}13.5$. There were 36 patients (male: 22, female: 14, 36%) who had pancreatic cancer with DM. There were 15 patients who showed over 7.0 mmol/L in their fasting BGL and 85 patients who showed under 7.0 mmol/L in their fasting BGL. Among the Non-DM, DM; BGL${\geq}7.0mmol/L$, and DM; BGL<7.0 mmol/L, there was not a statistical significance (p>0.05). Conclusion: The prevalence of pancreatic cancer was comparatively high in this study. If the fasting BGL was slightly over the normal BGL, we believe it will not give a severe disturbance when the patients have PET scan. Furthermore, the examination schedule doesn't need to change and the inconvenience from the delay of patients preparation will be reduced.

  • PDF

Adoption and Efficacy of ISO 15189 in Medical Laboratories for Diagnostic and Research (메디컬시험기관에서 ISO 15189 도입의 필요성과 시행의 효용성)

  • Yang, Man-Gil;Lee, Won Ho;Jun, Jin Hyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.2
    • /
    • pp.158-167
    • /
    • 2016
  • The requirements for medical laboratories ISO 15189 is examined in organization and a quality management system, stressing the importance of evidence, document control, and control of records and clinical material. Medical services are provided from the areas of resource management, and pre-examination, examination and post-examination processes. The main goal of ISO 15189 accreditation is to improve the quality of laboratory services provided for patients and clinical users not only through compliance with consensually developed and harmonized requirements but also by adopting the philosophy of continual improvement using the Plan-Do-Check-Act cycle. Laboratory quality should be evaluated and improved in all steps of the testing process as the state-of-the art indicates that the pre- and post-analytical phases are more vulnerable to errors than the intra-analytical phase. The Korea Laboratory Accreditation Scheme (KOLAS), a national accreditation body, provides medical laboratory accreditations for appropriate approaches to evaluating the competence of a medical laboratory in providing effective services to its customers and clinical users. Adoption of ISO 15189 in 2010s as a government policy has been delayed, and only 5 laboratories have been accredited to date in Korea. The medical laboratories should seek the adoption of ISO 15189 with a positive attitude for quality improvement and strengthening of international competitiveness.

Development and Application of Business Model Planting & Check Framework for Starts-Up Entrepreneur (비즈니스 모델 수립 및 점검 프레임워크를 이용한 창업기업 사례 연구 (대덕R&D특구 내 IT기술기반 창업기업 적용사례 중심으로))

  • Seo, Jin-Won;Min, Kyung-Se
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.3 no.1
    • /
    • pp.73-103
    • /
    • 2008
  • Over the past few years, "business models" has surged into the management vocabulary. But, while it has become quite fashionable to discuss business models, there has been still much confusion about what are business models and how they could make. In fact, business models can serve a positive and powerful role in corporate management. While other authors have recently offered definitions of "business model", none of them appears to be generally accepted. This paper presents the absence of the generally definition of the business models, elements of business model and classify business logic. To help start-up entrepreneurs better understand, found and check business models thus, this paper propose a method of business model, understanding, founding and checking. The dissertation will present an effective business model building method which is necessary for the start-up entrepreneurs to start business. This paper consists of three parts. first is showing the previous study of business model. The second is the re-definition business model and elements based on the first and to present a new method of business model plating and checking for start-up IT (information technology) company's entrepreneurs. The last is application of the methode. This study applied the methode to a company which is located in "DAEDEOK INNOPOLIS"; this company has specialized Information technology.

  • PDF

A Study of Guidelines for Genetic Counseling in Preimplantation Genetic Diagnosis (PGD) (착상전 유전진단을 위한 유전상담 현황과 지침개발을 위한 기초 연구)

  • Kim, Min-Jee;Lee, Hyoung-Song;Kang, Inn-Soo;Jeong, Seon-Yong;Kim, Hyon-J.
    • Journal of Genetic Medicine
    • /
    • v.7 no.2
    • /
    • pp.125-132
    • /
    • 2010
  • Purpose: Preimplantation genetic diagnosis (PGD), also known as embryo screening, is a pre-pregnancy technique used to identify genetic defects in embryos created through in vitro fertilization. PGD is considered a means of prenatal diagnosis of genetic abnormalities. PGD is used when one or both genetic parents has a known genetic abnormality; testing is performed on an embryo to determine if it also carries the genetic abnormality. The main advantage of PGD is the avoidance of selective pregnancy termination as it imparts a high likelihood that the baby will be free of the disease under consideration. The application of PGD to genetic practices, reproductive medicine, and genetic counseling is becoming the key component of fertility practice because of the need to develop a custom PGD design for each couple. Materials and Methods: In this study, a survey on the contents of genetic counseling in PGD was carried out via direct contact or e-mail with the patients and specialists who had experienced PGD during the three months from February to April 2010. Results: A total of 91 persons including 60 patients, 49 of whom had a chromosomal disorder and 11 of whom had a single gene disorder, and 31 PGD specialists responded to the survey. Analysis of the survey results revealed that all respondents were well aware of the importance of genetic counseling in all steps of PGD including planning, operation, and follow-up. The patient group responded that the possibility of unexpected results (51.7%), genetic risk assessment and recurrence risk (46.7%), the reproduction options (46.7%), the procedure and limitation of PGD (43.3%) and the information of PGD technology (35.0%) should be included as a genetic counseling information. In detail, 51.7% of patients wanted to be counseled for the possibility of unexpected results and the recurrence risk, while 46.7% wanted to know their reproduction options (46.7%). Approximately 96.7% of specialists replied that a non-M.D. genetic counselor is necessary for effective and systematic genetic counseling in PGD because it is difficult for physicians to offer satisfying information to patients due to lack of counseling time and specific knowledge of the disorders. Conclusions: The information from the survey provides important insight into the overall present situation of genetic counseling for PGD in Korea. The survey results demonstrated that there is a general awareness that genetic counseling is essential for PGD, suggesting that appropriate genetic counseling may play a important role in the success of PGD. The establishment of genetic counseling guidelines for PGD may contribute to better planning and management strategies for PGD.

Effects of Coculture on Development of Biopsied Mouse Embryos as a Preclinical Model for Preimplantation Genetic Diagnosis of Human Embryos (생쥐 모델을 이용한 배아의 할구 생검법과 할구가 생검된 배아의 배양시 공배양 효과에 관한 연구: 인간에서의 착상 전 유전진단 기술 개발을 위한 동물실험 모델의 개발)

  • Kim, S.H.;Ryu, B.Y.;Jee, B.C.;Choi, S.M.;Kim, H.S.;Pang, M.G.;Oh, S.K.;Suh, C.S.;Choi, Y.M.;Kim, J.G.;Moon, S.Y.;Lee, J.Y.;Chae, H.D.;Kim, C.H.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.26 no.1
    • /
    • pp.9-20
    • /
    • 1999
  • The genetic defects in human gametes and embryos can cause adverse effects on overall reproductive events. Biopsy of embryos for preimplantation genetic diagnosis (PGD) offers a new possibility of having children free of the genetic disease. In addition, advanced embryo culture method may enhance the effectiveness of embryo biopsy for the practical application of PGD. This experimental study was undertaken to evaluate the effects of coculture on the development in vitro of biopsied mouse embryos as a preclinical model for PGD of human embryos. Embryos were obtained after in vitro fertilization (IVF) from F1 hybrid mice (C57BLfemale/CBAmale). Using micromanipulation, 1, 2, 3 or 4 blastomeres of 8-cell stage embryos were aspirated through a hole made in the zona pellucida by zona drilling (ZD) with acidic Tyrode's solution (ATS). After biopsy of blastomeres, embryos were cultured in vitro for 110 hours in Ham's F-10 supplemented with 0.4% BSA or cocultured on the monolayer of Vero cells in the same medium. The frequence of blastocyst formation were recorded, and the embryos beyond blastocyst stage were stained with 10% Giemsa to count the total number of nuclei in each embryo. There was no significant difference in the blastocyst formation between the zona intact control group and the zona drilling (ZD) only, or biopsied groups. The hatching rate of all the treatment groups except 4/8 group was significantly higher than that of control group. In all the treatment groups, there was a significant reduction in the mean cell number of embryos beyond blastocyst stage ($50.2{\pm}14.0$ in control group vs. $41.2{\pm}7.9$ in ZD, $39.3{\pm}8.8$ in 7/8, $29.7{\pm}6.4$ in 6/8, $25.1{\pm}5.7$ in 5/8, and $22.1{\pm}4.3$ in 4/8 groups, p<0.05). When the same treatments were followed by coculture with Vero cells, a similar pattern was seen in the blastocyst formation and the hatching rate. However, in all the treatment groups, there was a significant increase in the mean cell number of embryos beyond blastocyst stage with coculture, compared with the parallel groups without coculture. In the cleavage rate of biopsied blastomeres cultured for 110 hours after IVF, there was no significant difference between coculture and non-coculture groups (87.2% vs. 78.7%). However, the mean cell number of embryos developed from the biopsied blastomeres was significantly higher in coculture group ($11.5{\pm}4.7\;vs.\;5.9{\pm}1.9$, p<0.05). In conclusion, biopsy of mouse embryos after ZD with ATS is a safe and highly efficient method for PGD, and coculture with Vero cells showed a positive effect on the development in vitro of biopsied mouse embryos and blastomeres as a preclinical model for PGD of human embryos.

  • PDF