• Title/Summary/Keyword: 3D스캔

Search Result 415, Processing Time 0.027 seconds

A Virtual Fitting System Using The Top and Bottom Image of Garment (상하의 의류 영상을 이용한 가상 의류 착의 시스템)

  • Choi, Ran;Cho, Chang-Suk
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.7
    • /
    • pp.941-950
    • /
    • 2012
  • A virtual garment fitting system which fits the top and bottom of a garment on 3D body data is introduced. This system uses the laser scanned 3D body data and the digital images photographed the front and back of a garment. The digital images are modeled to reflect tensions among particles in the images and the friction and gravity effects are considered in the fitting process to the body data. When a bottom is fitted, a virtual belt to hold the bottom in the waist is introduced since gravity effects pull down it. Also the process for fitting the top and bottom on layers is proposed here. The system has the strengths that it uses only the front and back image of a garment instead of using complicated patterns of a garment, and provides a realistic fit result as a 3D figure. As on-line retailing shop in present displays front and back images of garments, this system also does. However this system provides a differentiated service to user than present retailing shop as showing a 3D fit image. It will make a new trend in online shop retailing of garment.

Comparative Analysis of Body Measurement and Fit Evaluation between 2D Direct Body Measuring and 3D Body Scan Measuring (직접측정과 3차원 측정에 따른 인체치수 및 의복 착장 비교분석)

  • Istook, Cynthia L.;Lim, Ho-Sun;Chun, Jong-Suk
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.6
    • /
    • pp.1347-1358
    • /
    • 2011
  • This study purposed to analyze differences in body measurement between the 2D direct body measuring method and the 3D body scan measuring method and to perform the appearance evaluation and cross-sectional evaluation of the fit of pants to which body measurements obtained by each measuring method were applied. Body measuring was conducted in 10 women in their 20s-30s using 2D direct body measuring and 3D automatic measuring with Hamamatsu body scanner. Among the 10 women, 3 participated in experimental garment wearing. Experimental pants were made using their 2D direct body measurements and 3D automatic measurements, and wearing tests were performed through expert evaluation and cross-sectional evaluation. The results of the experiment were as follows. According to the results of comparative analysis on differences between 2D direct body measurements and 3D scan measurements, 3D automatic measurements were significantly larger in bust circumference, ankle circumference, armscye circumference, shoulder length, scye depth, and arm length. As circumferences measured with the 3D body scanner were somewhat larger than directly measured ones, it is suggested to adjust ease when using existing pattern making methods. We prepared experimental garments by the same pattern making method through applying body measurements obtained with the two measuring methods, and assessed the fit of the garment comparatively through expert evaluation and 3D scan cross-sectional evaluation. According to the results, 2D-pants using 2D direct body measurements was slightly tighter than 3D-pants using 3D measurements in waist circumference, hip circumference, and abdominal circumference. In the results of comparing appearance in terms of the fit of the experimental garment in each subject, significant difference was observed in most of the compared items. This result suggests that 3D automatic body measuring data may show different accuracy according to body shape and therefore it is necessary to examine difference between 2D direct body measurements and 3D automatic measurements according to body shape.

Classification of Elderly Men's Foot Side Type from 3D Scan Data (3차원 스캔 데이터에 의한 노년 남성의 발 측면유형 분류)

  • Kim, Nam-Soon;Do, Wol-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.4
    • /
    • pp.427-439
    • /
    • 2014
  • This study identifies the foot side shapes of elderly men by classifying foot types according to 3D foot shapes and analyzing individual characteristics. The subjects were 284 elderly men over 60 years of age who lived in Gwangju and did not have foot related diseases. They were measured with a scanner (Nexcan$^{(R)}$ of K&I Technology) to obtain three dimensional feet shapes. Anthropometric measuring items consisted of 28 items estimated on the right foot of each subject. 3D scan data were analyzed by various statistical methods such as factor analysis, ANOVA and cluster analysis using the statistical program SPSS 19.0. A total of 7 factors were extracted through a factor analysis and these factors represent 77.56% of total variance. The 8 factors were: inside height and side gradient, ankle thickness, size from foot center to ankle, lateral malleolus height, forefoot height, instep and heel height and gradient. A total of 3 clusters (as foot type) were categorized using 7 factor scores by cluster analysis. Type 1 was classified as high forefoot and low midfoot compared to the length. Type 2 was classified as low forefoot and high midfoot, and type 3 was classified as low forefoot and low midfoot.

Analysis of the Fracture Roughness of Crystalline Rock under Multi-stage Stress Conditions (다단계압력 환경하에서의 결정질 암석의 절리면 거칠기 변화 분석)

  • Choi, Junghae;Kim, Heyjin
    • The Journal of Engineering Geology
    • /
    • v.29 no.3
    • /
    • pp.237-249
    • /
    • 2019
  • The roughness changes on a fracture surface were analyzed via a multi-stage compression test under high temperatures to assess how the cracks in a rock mass affect groundwater movement. The analyzed samples consist of coarse granitic rocks from approximately 40 and 270 m depth, and fine granitic rocks from 500 m depth. The compression test was conducted on $20{\times}40{\times}5mm$ samples using a loading system where the pressure increases in 10 MPa increments to 120 MPa. A high-resolution 3D confocal laser scanning microscope (CLSM) was used to observe the surface changes, including the roughness changes, at each pressure step. The roughness change was calculated based on the roughness factor. The experimental results indicate that the roughness of the fracture surface varies with rock type under the stepwise pressure conditions. These data provide a basis for predicting groundwater flow along rock fractures.

Development of Remote Measurement Method for Reinforcement Information in Construction Field Using 360 Degrees Camera (360도 카메라 기반 건설현장 철근 배근 정보 원격 계측 기법 개발)

  • Lee, Myung-Hun;Woo, Ukyong;Choi, Hajin;Kang, Su-min;Choi, Kyoung-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.157-166
    • /
    • 2022
  • Structural supervision on the construction site has been performed based on visual inspection, which is highly labor-intensive and subjective. In this study, the remote technique was developed to improve the efficiency of the measurements on rebar spacing using a 360° camera and reconstructed 3D models. The proposed method was verified by measuring the spacings in reinforced concrete structure, where the twelve locations in the construction site (265 m2) were scanned within 20 seconds per location and a total of 15 minutes was taken. SLAM, consisting of SIFT, RANSAC, and General framework graph optimization algorithms, produces RGB-based 3D and 3D point cloud models, respectively. The minimum resolution of the 3D point cloud was 0.1mm while that of the RGB-based 3D model was 10 mm. Based on the results from both 3D models, the measurement error was from 10.8% to 0.3% in the 3D point cloud and from 28.4% to 3.1% in the RGB-based 3D model. The results demonstrate that the proposed method has great potential for remote structural supervision with respect to its accuracy and objectivity.

Editorial Design for Effective Research Report of Excavating Cultural Properties (효과적인 문화재발굴조사보고서를 위한 편집디자인)

  • Byun, Ji-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.11
    • /
    • pp.167-174
    • /
    • 2007
  • We are depending on tedious work by hand with tremendous time and effort in order to measure drawing of relics and remains despite of advanced computer and editing technology. Also, it is necessary to improve a designing element in the research report of cultural properties although we have more editorial and technical skills than we have done. The purpose of this article is to help to develop an aesthetic element and measurement of drawing of relics and remains for the effective editing in the current cultural properties research report. At the same time, through the gradual improvement of 3D scan and photographing techniques, research report of cultural properties will create database with useful and valuable material and provide aesthetic and efficient information.

Classification of Breast Shape of Women Aged 11~15 Using 3D Body Scan Data (3D 인체 스캔 데이터를 이용한 11~15세 성장기 여성의 유방형태에 따른 유형 분류)

  • Han, Tingting;Song, Hwa Kyung;Lee, Kyu Sun
    • Fashion & Textile Research Journal
    • /
    • v.19 no.6
    • /
    • pp.786-794
    • /
    • 2017
  • The purpose of this study is to analyze and classify breast shape of women aged 11~15 using 3D body scan data. In this study, 250 women's body scans were selected from the 6th Size Korea dataset, and 30 items from each of the scan were measured using RapidForm XOR 3 program. The principal component analysis and cluster analysis were conducted using statistical program SPSS 17.0. The five principal components were identified; breast drooping and breast capacity, size from chest to under bust area, breast protrusion, breast height, and under breast angle & outer distance of breast. As the results of cluster analysis, woman's breast types were classified into four types. The breast type 1 was protrusion type (25.1%) which is considered as the breast maturity stage. The breast type 2 had the most drooped breast covering a large area (20.2%). The breast type 3 had the least prominent breast with a highest nipple point, which was considered as the early breast development stage (38.9%). The breast type 4 had the obesity of the chest and breast circumferences with the slightly prominent and the least drooped breast (15.8%). This study can provide fundamental information to develop sizing system and brassiere pattern for junior girls.

3D Tunnel Face Modelling for Discontinuities Characterization: A Comparison of Lidar and Photogrammetry Methods (불연속성 특성화를 위한 3차원 터널 막장 모델링: 라이더 및 사진 측량 접근 방식의 비교 분석 중심으로)

  • Chuyen, Pham;Hyu-Soung, Shin
    • Tunnel and Underground Space
    • /
    • v.32 no.6
    • /
    • pp.549-557
    • /
    • 2022
  • Tunnel face mapping involves the determination of rock discontinuities or weak rock conditions where extra support might be required. In this study, we investigated the application of Lidar scanning and photogrammetry to quantitatively characterize discontinuities of the rock mass on the tunnel face during excavation. The 3D models of tunnel faces generated by using these methods enable accurate and automatic discontinuity measurement to overcome the limitations of manual mapping. The results of this study show that both photogrammetry and Lidar can be used to reconstruct the 3D model of the tunnel face, although the photogrammetric 3D model is less detailed than its counterpart produced by Lidar. Given acceptable accuracy and cost-effectiveness, photogrammetry can be a fast, reliable, and low-cost alternative to Lidar for acquiring 3D models and determining rock discontinuities on tunnel faces.

Classification of foot shapes of young and middle-aged/elderly men (청년층과 중노년층 남성의 발 형태 분류)

  • Lim, Ho Sun
    • The Research Journal of the Costume Culture
    • /
    • v.23 no.5
    • /
    • pp.894-905
    • /
    • 2015
  • The present study analyzed data from the 3D measurement of the feet of men aged over 20 years residing in the capital region as part of the 6th Anthropometry of Size Korea. To analyze the characteristics of the foot shapes of young men aged 20~39 years and middle-aged/elderly men aged 40~69 years by age and by type, a cluster analysis was conducted using the factors derived through the factor analysis as independent variables. The results of the study that analyzed the characteristics of foot shapes by type according to differences in age were as follows. First, through the analysis of the characteristics of the foot shapes of young men by type, five factors were extracted, and the foot shapes were classified into three types: Type 1 (short and flat), Type 2 (thick), and Type 3 (long and wide). Second, through the analysis of the characteristics of the foot shapes of middle-aged/elderly men by type, six factors were extracted, and the foot shapes were classified into four types: Type 1 (short and regular), Type 2 (flat), Type 3 (thick), and Type 4 (long and regular). The results of the present study are expected to serve as basic data for the design of shoes by age and foot type.

Comparison of the accuracy of implant digital impression coping (임플란트 디지털 인상용 코핑의 정확성 비교)

  • Ahn, Gyo-Zin;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.1
    • /
    • pp.29-40
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the accuracy of impression taking method using the encoded healing abutment, scan body and pick-up impression coping with different implant angulations. Materials and Methods: Master model was fabricated by 3D printer and three implants were placed into the model with 0°, 10° and 20° mesial angulation. The abutments were secured to each implants and master model was scanned to make a reference model. Group P model was fabricated using pick-up impression copings and model was scanned after securing the abutments. Encoded healing abutment (Group E) and scan body (Group S) were secured on the master model and digital impression was taken using intraoral scanner 15 times each. Each STL files of test groups were superimposed with reference model using best fit alignment and root mean square (RMS) value was analyzed. Results: The RMS values were lowest in Group P, followed by Group S and Group E. Group P showed significant difference with Group S and E (P < 0.05) while there was no significant difference between Group S and E. Correlation between implant angulation and RMS value was significant in Group E (P < 0.05). Conclusion: The pick-up impression coping method showed higher accuracy and there was no significant difference in accuracy between the healing abutment and the scan body. The clinical use of the encoded healing abutment is possible, but it should be used with caution in the case of angulated implant.