• Title/Summary/Keyword: 33-mode

Search Result 802, Processing Time 0.025 seconds

A Hardware Design of Effective Intra Prediction Angular Mode Decision for HEVC Encoder (HEVC 부호기를 위한 효율적인 화면내 예측 Angular 모드 결정 하드웨어 설계)

  • Park, Seungyong;Choi, Juyong;Ryoo, Kwangki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.4
    • /
    • pp.767-773
    • /
    • 2017
  • In this paper, we propose a design of Intra prediction angular mode decision for HEVC encoder. Intra prediction coding of HEVC is a method for predicting a current block by referring to samples reconstructed around a current block. Intra prediction supports a total of 35 modes with 1 DC mode, 1 Planar mode, and 33 Angular modes. Intra prediction coding of HEVC works by performing all 35 modes for efficient encoding. However, in order to process all of the 35 modes, the computational complexity and operational time required are high. Therefore, this paper proposes comparing the difference in the value of the original pixel, using an algorithm that determines angular mode efficiently. This new algorithm reduces the Hardware size. The hardware which is proposed was designed using Verilog HDL and was implemented in 65nm technology. Its gate count is 14.9K and operating speed is 2GHz.

Decoupling Method Between Digital Signals on FPCB and Mobile Handset Antenna

  • Kim, Joon-Chul;Kim, Hyeong-Dong
    • ETRI Journal
    • /
    • v.33 no.1
    • /
    • pp.121-124
    • /
    • 2011
  • Digital harmonics, which may reduce the radio frequency sensitivity of a system, can be coupled with an antenna in a mobile handset. This letter presents a decoupling method for increasing the isolation between digital harmonics on a flexible printed circuit board (FPCB) and an antenna in terms of the ground mode current and the concept of reaction. We model the signal and ground lines in an FPCB as a loop circuit exciting a ground mode current and demonstrate a simple but efficient decoupling method for reducing the excited ground mode current.

An Efficient Intra Prediction Mode Decision Method for H.264 Standard (H.264 표준을 위한 효율적인 인트라 예측 모드 결정 방법)

  • Park, Ji-Yoon;Lee, Chang-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.10C
    • /
    • pp.778-786
    • /
    • 2008
  • The H.264/AVC video coding standard shows superior coding efficiency by adopting many new techniques. However, the encoding complexity increases greatly to achieve higher coding efficiency. Especially, the rate distortion optimization technique, which is used to decide the intra-prediction mode, increases the encoding complexity. In this paper, we propose an efficient intra-prediction mode decision method. By using the variance of pixel values and the edge direction, the computational complexity of the intra-prediction mode decision is greatly reduced.

A Novel Dual-Mode Bandpass Filter Based on a Defected Waveguide Resonator

  • Guan, Xuehui;Fu, Wei;Liu, Haiwen;Ahn, Dal;Lim, Jong-Sik
    • ETRI Journal
    • /
    • v.33 no.6
    • /
    • pp.953-956
    • /
    • 2011
  • A novel dual-mode bandpass filter (BPF) using a dual spiral-shaped defected ground waveguide (DGW) resonator is proposed in this letter. The dual-mode characteristic of this filter is achieved by loading a defected T-shaped stub at the midline of the spiral-shaped DGW resonator. Also, non-orthogonal input and output feed-lines are adopted in the filter. Based on the compact DGW structure, a dual-mode BPF with central frequency of 1.5 GHz for the global positioning system is designed, fabricated, and measured. Measured results agree well with the predicted response and verify the proposed methodology.

Performance Evaluation of Set-top Box Energy Saving using Poisson Process Modeling (포아송 프로세스 모델링을 통한 셋톱박스 에너지 절감 성능 분석)

  • Kim, Yong-Ho;Kim, Hoon
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.10 no.1
    • /
    • pp.33-39
    • /
    • 2011
  • This paper considers a performance analysis of set-top box (STB) power saving schemes. STB converts the signal into content which is then displayed on the television (TV) screen, and there are typically two operation modes: on mode and stand-by mode. The total energy consumption (TEC), a typical measure of power consumption of STB, is defined by the sum of power consumption in each mode. Recently there are some works of STB power saving schemes that transit STB operation modes efficiently, and the mode transition time point of those schemes can be different. Thus it is required to develop a performance evaluation method that reflects mode transition time points of each scheme to get TEC correctly. This paper proposes a performance evaluation method for STB power consumption using Poisson process to consider the mode transition time point. By modeling STB mode transitions as events of Poisson process, the average time duration of STB mode is computed and accordingly the effect of power saving is evaluated. The performance evaluation result shows that the proposed method achieves 1 to 19% improvement in power consumption compared with a conventional performance evaluation method.

  • PDF

Sliding Mode Control Based DTC of Sensorless Parallel-Connected Two Five-Phase PMSM Drive System

  • Kamel, Tounsi;Abdelkader, Djahbar;Said, Barkat;Al-Hitmi, M.;Iqbal, Atif
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1185-1201
    • /
    • 2018
  • This paper presents a sensorless direct torque control (DTC) combined with sliding mode approach (SM) and space vector modulation (SVM) to achieve mainly a high performance and reduce torque and flux ripples of a parallel-connected two five-phase permanent magnet synchronous machine (PMSM) drive system. In order to increase the proposed drive robustness and decrease its complexity and cost, the rotor speeds, rotor positions, fluxes as well as torques are estimated by using a sliding mode observer (SMO) scheme. The effectiveness of the proposed sliding mode observer in conjunction with the sliding mode control based DTC is confirmed through the application of different load torques for wide speed range operation. Comparison between sliding mode control and proportional integral (PI) control based DTC of the proposed two-motor drive is provided. The obtained speeds, torques and fluxes responses follow their references; even in low and reverse speed operations, load torques changes, and machines parameters variations. Simulation results confirm also that, the ripples of the torques and fluxes are reduced more than 3.33% and 16.66 %, respectively, and the speed overshoots and speed drops are reduced about 99.85% and 92.24%, respectively.

Sensitivity Properties of Acoustic Emission Sensor Using NKN System Ceramics (NKN계 세라믹을 이용한 음향방출 센서의 감도 특성)

  • Hong, Jae-Il;Shin, Sang-Hoon;Yoo, Ju-Hyun;Jeong, Yeong-Ho;Lee, Sang-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.11
    • /
    • pp.696-701
    • /
    • 2014
  • In this study, in order to develop coupled vibration mode piezoelectric devices for Acoustic Emission (abbreviated as AE) sensor application with outstanding displacement and piezoelectric properties have been simulated by ATILA FEM program. And, From the results of ATILA simulation, the AE sensor specimen, obtained superior electromechanical coupling factor and displacement, when the size of specimen is $3.45mm{\Phi}{\times}3.45mm$ with ratio of diameter/thickness(${\Phi}/T$)= 1.0. Therefore, AE sensor was fabricated by (Na,K,Li)(Nb,Ta) $O_3$(abbreviated as NKL-NT) system piezoelectric ceramics using coupled vibration mode. The piezoelectric properties of NKL-NT ceramics was exhibited that piezoelectric constant($d_{33}$), piezoelectric voltage constant($g_{33}$) and electro mechanical coupling factor($k_p$) have the excellent values of 261[pC/N], 40.10[$10^{-3}Vm/N$], and 0.44, respectively. The manufactured piezoelectric device with ratio of ${\Phi}/T$= 1.0 indicated the optimum values of resonant frequency(fr)= 556.5[kHz], antiresonant frequency(fa)=631.1[kHz], and effective electromechanical coupling factor(keff)= 0.473. The maximum sensitivity of the coupled vibration mode AE sensor was 55[dB] at the resonant frequency of 75[kHz]. The results show that the coupled vibration mode piezoelectric device is a promising candidate for the application AE sensor piezoelectric device.

Studies on Failure Kind Analysis of the Radiologic Medical Equipment in General Hospital (종합병원 진단용방사선장비의 고장유형 분석)

  • Lee, Woo-Cheul;Kim, Jeong-Lae
    • Journal of radiological science and technology
    • /
    • v.22 no.2
    • /
    • pp.33-39
    • /
    • 1999
  • This paper included a data analysis of the unit of medical devices using mainternance recording card that had medical devices of unit failure mode, hospital of failure mode and MTBF. The results of the analysis were as follows : 1. Medical devices of unit failure mode was the highest in QC/PM such A hospital as 33.9%, B hospital 30.9%, C hospital 30.3%, second degree was the Electrical and Electronic failure such A hospital as 23.5%, B hospital 25.3%, C hospital 28%, third degree was mechanical failure such A hospital as 19.5%, B hospital 22.5%, C hospital 25.4%. 2. Hospital of failure mode was the highest in Mobile X-ray device(A hospital 62.5%, B hospital 69.5%, C hospital 37.4%), and was the lowest in Sono devices(A hospital 16.76%, B hospital 8.4%, C hospital 7%). 3. Mean time between failures(MTBT) was the highest in SONO devices and was the lowest in Mobile X-ray devices which have 200 - 400 failure hours. 4. Anverage failure ratio was the highest in Mobile X-ray devices(A hospital 31.3%, B hospital 34.8%, C hospital 18.7%), and was the lowest in Sono(Ultrasound) devices (A hospital 8.4%, B hospital 4.2%, C hospital 3.5%). 5. Failure ratio results of medical devices according to QC/PM part of unit failure mode were as follows ; A hospital was the highest part of QC/PM (50%) in Mamo X-ray device and was the lowest part of QC/PM(26.4%) in Castro X-ray. B hospital was the highest part of QC/PM(56%) in Mobile X-ray device, and the lowest part of QC/PM(12%) in Gastro X-ray. C hospital was the highest part of QC/PM(60%) in R/F X-ray device, and the lowest a part of QC/PM(21%) in Universal X-ray. It was found that the units responsible for most failure decreased by systematic management. We made the preventive maintenance schedule focusing on adjustement of operating and dust removal.

  • PDF