A Study on the Corrosion Characteristics Evaluation for Reactor Material of Waste Water Treatment (폐수처리 반응기용 재질의 부식특성 평가에 대한 연구)

  • Kim, Ki-Tae;Lee, Tae-Gu;Moon, Seung-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.4 no.2
    • /
    • pp.60-65
    • /
    • 2008
  • As the operating conditions in a supercritical oxidation reactor are set in high temperature with high pressure causing a reactor suffering from the harsh circumstances. It means the reactor adopts itself with Fe-Cr alloy in acidic atmosphere with low pH value and Ni alloy in basic atmosphere with high pH value due to its superior corrosion resistance. The study, whose target waster water is pertinent to the latter part, has selected Ni alloy such as ostenite type stainless steel 304 and 316, superstainless steel AL6XN, Inconel 625, MAT 21, and titanium Gr. 5 in order to measure corrosion resistance against those samples under the same conditions of temperature and pressure applied for a supercritical oxidation reactor. The result shows the identifiable difference in corrosion resistance by observing the surface states through a scanning probe microscope as well as measuring the weight loss through making the samples above deposited in wastewater for two-week and four-week stay. The purpose of this corrosion experiment is to identify the most corrosion-resistant material among sample species pre-selected according to pH concentration of wastewater in pursue of applying for a reactor exposed to the extreme corrosion environment. It is because such a reactor made of a verified material enables to safeguard a stable operation under the supercritical wastewater processing facility.

  • PDF

Heat Transfer Characteristics of Bulkhead Penetration Piece for A60 Class Compartment II: Fire Resistance Test for Piece Material and Insulation Types (A60급 구획 적용 격벽 관통용 관의 열전달 특성 II: 관 재질 및 단열재 종류에 따른 방화시험)

  • Park, Woo-Chang;Song, Chang Yong
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.4
    • /
    • pp.340-349
    • /
    • 2019
  • In the case of a fire accident on a ship or an offshore plant, the design of the bulkhead penetration piece must be verified via a fire test procedure (FTP), as specified by the Maritime Safety Committee (MSC). The purpose of this study is to verify both the numerical analysis results and the design specifications for penetration pieces that could be applied to the A60 class bulkhead division. In this study, the FTP was carried out in accordance with the test procedure prescribed in the MSC regulation. In order to review the fire resistance performance according to the material type, bulkhead penetration pieces for the FTP were made from brass, carbon steel for machine structures (S45C), and austenite stainless steel (SUS316). In addition, spray-type insulation and mechanical fastener-type insulation were applied to investigate the fire resistance performance according to the type of insulation. To verify the heat transfer numerical analysis results for the A60 class bulkhead penetrating piece from this test study, the design specifications of the penetrating piece material and the insulation type applicable to a ship and an offshore plant were identified.

Development of Drainage Water Disinfection System by Electric Shock in Recirculating Soilless Culture (순환식 수경재배에서 배액의 전기충격살균법 연구)

  • Lee, Mun Haeng;Kim, Sung Eun;Lee, Sang Don;Lee, Jae Eun;Kim, Hak Sun;Cho, Suk Keong;Sim, Sang Youn;Kim, Young Shik
    • Journal of Bio-Environment Control
    • /
    • v.25 no.1
    • /
    • pp.49-56
    • /
    • 2016
  • This study was conducted to develop the disinfection system using electric shock for recycled nutrient solution in recycling soilless culture. Stainless steel (SUS 316) was found as the most appropriate electrode material for electrical disinfection system from the view of high electrical conductivity, low electric resistance, and low price. There were no changes in nutritional elements when the electric shock passed through the nutrient solution by stainless steel electrode. The amount of electric current increased with width than thickness of the electrode. The farther the distance between the electrodes was increased the time to reach out the aimed amount of current. The electric shock was applied to Ralstonia solanacearum and Fusarium oxysporum as representative bacteria and also fungi. Any of those pathogens were killed with the percentage of higher than 97% in the condition of 15VDC or 24VDC.

The Corrosion Behavior of Li/K Carbonate Melts with CaCO3 Additives on Separator Plate in the Molten Carbonate Fuel Cell in the Anode Environments

  • Cho, Kyehyun;Lee, Chul-Hwan;Sung, Zu-Hwan
    • Corrosion Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.129-136
    • /
    • 2006
  • High temperature corrosion behavior of AISI-type 316L stainless steel for the MCFC(molten carbonate fuel cell) bipolar application was studied by immersion test and penetration attack method in anode environment ($650^{\circ}C$, $Li_2CO_3/K_2CO_3=62/38$ mol%, $H_2/CO_2=80/20$ vol%) without or with different $CaCO_3$ content. Not only immersion test method but also morphological observation of samples in the carbonate melts are adopted as experimental methods. With aid of the morphological observation of cross section of samples immersed in a carbonate melt was possible to obtain penetration attack. The concentration effect of $CaCO_3$ inhibitor was investigated in order to verify the optimum concentration for practical application in MCFC stack operation. The corrosion rate in the presence of $CaCO_3$ was proven to be decreased as a function of $CaCO_3$ concentration. The corrosion rate in the presence of $CaCO_3$ was measured with a value of 6.9 mpy which is 2.4 times lower than that of inhibitor-free electrolyte. The cross section microscopy revealed that the internal penetration by oxidation in molten carbonate is very severe. In this case, the attack was occurred not only dissolution loss in the electrolyte by corrosion reaction but also weight gain through oxide layer by internal penetration.

Investigation of the TiCrN Coating Deposited by Inductively Coupled Plasma Assisted DC Magnetron Sputtering. (Inductively Coupled Plasma Assisted D.C. Magnetron Sputtering법으로 제작된 TiCrN 코팅층의 특성 분석)

  • Cha, B.C.;Kim, J.H.;Lee, B.S.;Kim, S.K.;Kim, D.W.;Kim, D.;You, Y.Z.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.22 no.5
    • /
    • pp.267-274
    • /
    • 2009
  • Titanium Chromium Nitrided (TiCrN) coatings were deposited on stainless steel 316 L and Si (100) wafer by inductively coupled plasma assisted D.C. magnetron sputtering at the various sputtering power on Cr target and $N_2/Ar$ gas ratio. Increasing the sputtering power of Cr target, XRD patterns were changed from TiCrN to nitride $Cr_2Ti$. The maximum hardness was $Hk_{3g}$ 3900 at $0.3\;N_2/Ar$ gas ratio. The thickness of the TiCrN films increased as the Cr target power increased, and it showed over $Hk_{5g}3100$ hardness at 100 W, 150 W. TiCrN films were deposited by the ICP assisted DC magnetron sputtering shown good wear resistance as the $N_2/Ar$ gas ratio was 0.1, 0.3.

Segmental Bioelectrical Impedance Analysis(SBIA) for Determining Body Composition (부위별 생체 전기 임피던스법을 이용한 체성분 분석에 관한 연구)

  • 차기철;손정민;김기진;최승훈
    • Korean Journal of Community Nutrition
    • /
    • v.2 no.2
    • /
    • pp.179-186
    • /
    • 1997
  • A new bioelectrical impedance method has been developed and evaluated. The electrodes; were made of stainless steel and electrical interfaces were created by an upright subject gripping hand electrodes and stepping onto foot electrodes. Eight tactile electrodes were in contact with surfaces of both hands and feet; thumb, palm and fingers, front sole, and rear sole. Automatic on-off switches were used to change current pathways and to measure voltage differences for target segments. Segmental body resistances and whole body resistance(RWHOLE)were measured in 60 healthy subjects. Segmental resistances of right arm(RRA), left arm(RLA), trunk(RT), right leg(RRL) and left leg(RLL)were310.0$\pm$61.6$\Omega$, 316.9$\pm$64.6$\Omega$, 25.1$\pm$3.4$\Omega$, 236.8$\pm$31.2$\Omega$ and 237.6$\pm$30.4$\Omega$, respectively. Individual segmental impedance indexes(Ht2/RRA, Ht2/RT, and Ht2 /RLA) were closely related to lean body mass(LBM)as measured by densitometry ranged from r=0.925 to 0.960. Ht2/(RRA+RT+RLA) predicted LBM slightly better(r=0.969) than the traditional index, Ht2/RWHOLE(r=0.964), supporting the accuracy of the segmental measurement. A multiple regression equation utilizing Ht2/RRA, Ht2/RT and Ht2/RRL predicted LBM with r=0.971. Ht2/RRA term of the regression contributed to more than 40$\%$ of the LBM prediction, indicating that lean mass of arm represented whole body LBM more closely than other body segments. The new bioimpedance method was characterized by upright posture, eight tactile electrodes, segmental measurements and utilization of electronic switches in comparison with the traditional method. The measurement with this new method was extremely reproducible, quick and easy to use.

  • PDF

Treatment of reactive dyes wastewater by electrochemical method (전기화학적인 방법에 의한 반응성 염료폐수의 처리)

  • Yu, Jae-Jeong;Jeon, Seong-Hwan;Park, Jeong-Min;Jeong, Jae-Ho;Park, Sang-Jeong;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.3
    • /
    • pp.245-251
    • /
    • 2002
  • Reactive dyes waste water, a toxic and refractory pollutant, was treated by an electrochemical method using $Ti/IrO_2$ as anode and Stainless Steel 316 as cathode. In this technique, sodium chloride as an electrolyte was added. A number of experiments were run in a batch system. Artificial samples (reactive blue 19, red 195, yellow 145) were used. Operation parameters, such as supporting electrolyte concentration, current density, pH and sample concentration have been investigated for their influences on COD and color removal efficiencies during electrolysis. After 5 and 90 minites of eletrolysis, color was reduced by 51.5% and 98.9% respectively. Under the condition of current density $10A/dm^2$, NaCl concentration 12mg/l and pH 3, 62.9% of $COD_{Cr}$ was removed after electrolysis for 90 minites. The optimum condition of color removal and COD reduction in this work was found to be the following : pH 3, sodium chloride concentration 20g/l, current density $10A/dm^2$. As a result, we confirmed to be effective to color removal and reduction of refractory organic material.

Fabrication of KSTAR PF CICC (KSTAR PF Coil용 CICC 제작)

  • Lim, B.;Lee, S.;Choi, J.;Jung, W.;Park, H.;Chu, Y.;Park, K.;Baek, S.;Kim, K.
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.301-303
    • /
    • 2003
  • The KSTAR(Korea Superconducting Tokamak Advanced Research) superconducting magnet system consist of 16 TF(Toroidal Field) and 14 PF(Poloidal Field) coils. Internally-cooled cabled superconductors will be used for the magnet system. The magnet system adopt a superconducting CICC (Cable-In-Conduit Conductor) type. The KSTAR PF 6, 7 CICCs use NbTi Superconducting cable with stainless steel 316LN conduit while the other PF CICC use Incoloy 908 conduit. For the fabrication of PF CICC, superconducting cables have been fabricated and the cable has the diameter of 22.3mm. A continuous CICC jacketing system is developed for the CICC jacketing and the jacketing system uses the tube-mill process, which consists of forming, welding, sizing and squaring procedures. The cabling and the jacketing process is described. The welding condition and design specification of CICCs are also discussed. The fabrication results including the geometrical specification and the void fraction will be discussed.

  • PDF

Macro and Micro-electrochemical Characteristics on Dissimilar Welding Metal of Double Wall Gas Pipe for Duel Fuel Engine (이중 연료 엔진용 이중벽 가스 배관 이종 용접부의 매크로 및 마이크로 전기화학적 특성)

  • Kim, Seong-Jong;Park, Jae-Cheul;Han, Min-Su;Jang, Seok-Ki
    • Corrosion Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.331-337
    • /
    • 2010
  • This study compared the macro and micro electrochemical characteristics at the local area of welding metal on dissimilar welding parts for type 304 stainless steel (SS) and type 316L SS. The materials are used for double wall gas pipe of duel fuel engine for a ship. The various potentiodynamic experiments were performed several times in 10% ${H_2C_2O_2}{\cdot}{H_2O}$ solution using macro and micro methods, respectively. The micro electrochemical experiments conducted to resolve at local area on cross-section of dissimilar welding materials by micro-droplet cell device. The micro-droplet cell techniques can be used almost electrochemical experiments to resolve corrosion characteristics of the limited electrode area of the metallic surface between wetted spot of working electrode and tip of sharpened capillary tube. The results of macro electrochemical experiments show that resistance of active dissolution reaction at welding zone was high due to low current density by formation of passivation protection film at passive region. According to the micro electrochemical experiment, the corrosion current density of welding zone and bond zone were relatively high.

A study of the cause of metal failure in treatment of femur shaft fracture - Fractographical and clinical analysis of metal failure- (대퇴골 간부 골절시 사용한 금속물의 금속부전(Metal failure)의 기전에 대한 연구)

  • Jeon, Chun-Bae;Seo, Jae-Sung;Ahn, Jong-Chul;Ahn, Myun-Whan;Ihn, Joo-Chyl
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.1
    • /
    • pp.81-93
    • /
    • 1990
  • The author fractographically analyized the cause of metal failure(the first time this procedure has been used for this metal failure)and also analyized it clinically. In this study, I selected eight cases which have been analyized fractographically. In all these cases, the analysis was done after treatment of metal failure of implants internally fixed to femur shaft fractures at the Department of Orthopedic Surgery, Yeung-Nam University Hospital during the six year period from May 1983 to September 1989. 1. Metal failure occured in five dynamic-compression plates, one Jewett nail, one screw in Rowe plate, and one interlocking nail. 2. The clinical cause of metal failure was deficiency of medial butress in five cases, incorrect position of implant in one case, and incorrect selection of implant in two cases. 3. The time interval between internal fixation and metal failure was four months in one case, between five months to twelve months in six cases, three years in one case. 4. The fractographically analytical cause of metal failure was ; first, impact failure, one case, second, fatigue failure, six cases, machining mark(stress liser), four cases type : low consistent cyclic fatigue failure irregular cyclic fatigue failure third, stress corrosion crack, one case. 5. 316L Stainless Steel has good resistance to corrosion. However, when its peculiar surface film is destroyed by fretting, it shows pitting corrosion. This is, perhaps, the main cause of metal failure. 6. It is possible that mechanical injury occured in implants during the manufacturing of implants or that making a screw hole is the main cause of metal failure.

  • PDF