A Study on the Life Prediction Method using Artificial Neural Network under Creep-Fatigue Interaction (인공 신경망을 이용한 크리프-피로 상호작용시 수명예측기법에 관한 연구)

  • 권영일;김범준;임병수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.6
    • /
    • pp.135-142
    • /
    • 2001
  • The effect of tensile hold time on the creep-fatigue interaction in AISI 316 stainless steel was investigated. To study the fatigue characteristics of the material, strain controlled low cycle fatigue(LCF) tests were carried out under the continuous triangular waveshape with three different total strain ranges of 1.0%, 1.5% and 2.0%. To study the creep-fatigue interaction, 5min., 10min., and 30min. of tensile hold times were applied to the continuous triangular waveshape with the same three total strain ranges. The creep-fatigue life was found to be the longest when the 5min. tensile hold time was applied and was the shortest when the 30min. tensile hold time was applied. The cause fur the shortest creep-fatigue life under the 30min. tensile hold time is believed to be the effect of the increased creep damage per cycle as the hold time increases. The creep-fatigue life prediction using artificial neural network(ANN) showed closer prediction values to the experimental values than by the modified Coffin-Manson method.

  • PDF

Determination of Chaboche Cyclic Combined Hardening Model for Cracked Component Analysis Using Tensile and Cyclic C(T) Test Data (표준 인장시험과 반복하중 C(T) 시험을 이용한 균열해석에서의 Chaboche 복합경화 모델 결정법)

  • Hwang, Jin Ha;Kim, Hune Tae;Ryu, Ho Wan;Kim, Yun Jae;Kim, Jin Weon;Kweon, Hyeong Do
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.15 no.2
    • /
    • pp.31-39
    • /
    • 2019
  • Cracked component analysis is needed for structural integrity analysis under seismic loading. Under large amplitude cyclic loading conditions, the change in material properties can be complex, depending on the magnitude of plastic strain. Therefore the cracked component analysis under cyclic loading should consider appropriate cyclic hardening model. This study introduces a procedure for determining an appropriate cyclic hardening model for cracked component analysis. The test material was nuclear-grade TP316 stainless steel. The material cyclic hardening was simulated using the Chaboche combined hardening model. The kinematic hardening model was determined from standard tensile test to cover the high and wide strain range. The isotropic hardening model was determined by simulating C(T) test under cyclic loading using ABAQUS debonding analysis. The suitability of the material hardening model was verified by comparing load-displacement curves of cyclic C(T) tests under different load ratios.

An Experimental Study on the Operational Characteristics and Performance of the Sodium Heat Pipe (나트륨 히트파이프의 작동 특성 및 성능에 관한 실험적 연구)

  • Kang, Hwan-Kook;Lee, Dong-Chan;Park, Sang-Woon;Song, Jee-Hyuk;Yoo, Jung-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.311-316
    • /
    • 2005
  • The experimental study for an operational characteristics and performance of the sodium heat pipe were carried out. For an experiment. the heat pipe which is 1000mm length and 25.4mm diameter of stainless steel container with 50 mesh of screen wick using sodium as a working fluid is manufactured and tested as functions of heat flow rate, inclined angle and operating temperature. The test results are as follows. During the start-up. frontal start up was observed because of the vapor density increasing as increased the hot zone. Also, the heat pipe showed uniform temperature over than $420^{\circ}C$ of the operating temperature. The average heat transfer coefficient increased as the heat flux and the vapor temperature increase, and the range of the total thermal resistance was 0.075-0.04 $^{\circ}C/W$ at the 12-53.55 $kW/m^2$ of heat flux and $500-750^{\circ}C$of operating temperature. The maximum heat flow rate was 750W at the 10 degree of top heating mode.

  • PDF

Manufacturing technology of micro parts by powder injection molding (PIM기술을 이용한 마이크로 부품 성형기술)

  • Lee, W.S.;Ko, S.H.;Jang, J.M.;Kim, I.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.60-63
    • /
    • 2009
  • Manufacturing technologies of micro spur gear and micro mold by micro PIM were studied with stainless steel feedstock. For molding of gears, micro mold with gear cavity of 1.2 mm in diameter was produced by wire EDM. The proper injection pressure was selected to 70bar by observation and measuring of shapes and shrinkage of gears before/after sintering. For fabrication of micro mold, a tiny polymer gear was produced by injection into the mold. Then, 316L feedstock was again injected/compressed on the polymer gear and debinded together with polymer gear followed by sintering. As a result, another metal mold with gear cavity reduced to about 20% was fabricated and through repetition of this process chain, micro gear mold with cavity about below 800 um was finally obtained. In reduction of size by injection/compression molding, height of gear tooth was shrunk more and the effort for decrease of roughness of micro cavity were carried out ultrasonic polishing and as a result, the roughness in cavity decreased from 3-4 um to about 200 nm.

  • PDF

Glow discharge cleaning 법에 의한 stainless steel의 outgassing rate 감소

  • 임종연;이상균;서인용;최상철;홍승수;신용현;정광화
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.40-40
    • /
    • 1999
  • 가속기나 토카막과 같은 거대한 진공 장치의 용기 내벽을 청정화 하기 위해서는 용기 전체의 열처리(굽기, Baking)와 글로우 방전(Glow discharge) 법을 병행하여 사용한다. Baking은 일반 기체(N2, O2, 그리고 CO2)와 물(H2O)의 탈착에 효과적이고, Glow discharge cleaning은 탄소(Carbon-based)와 산소(Oxygen-based) 화합물의 탈착에 효과적이다. 특히 Glow discharge cleaning의 경우에는 전극의 모양, 진공 용기의 재질과 모양, 전극간의 거리, 사용되는 반응 기체의 압력 등에 따라 그 효과에 큰 차이가 있으므로 다각적인 연구가 필요하다. 본 연구에서는 그림 1과 같이 시험용 스테인레스(AISI 304와 AISI 316LN) 진공 용기를 설치하고, 시험 용기의 한쪽은 배기 용기와 oriffice로, 다른 편은 불순물의 정성.정량 분석을 위해 RGA(Residual gas analyser) 용기와 oriffice로 연결하였다. 전체 시스템 중에서 배기 부분과 분석 부분은 15$0^{\circ}C$에서 24시간 가열하여 전체의 기저 진공도를 1$\times$10-8Torr로 하였다. 기저 진공도의 용기에 고순도의 반응기체 (He, Ar, Ar+He, Ar+H2, Ar+N2 등)를 주입한후, DC 전압(0.8~1.5kV)을 변화하며 글로우 방전의 최적조건을 찾았다. 방전 동안 시험용 용기에서 방출되는 반응 기체 이외의 기체를 RGA로 측정하였고 외부에 Thermocouple을 여러곳에 장착하여 온도 변화를 측정하였다. 이상의 결과로부터 진공 용기 표면적으로부터의 불순물 탈착(desorption)과 불순물 분석, 플라즈마와 내벽의 상호작용등에 대한 결론을 얻을 수 있었다. 또한 Baking과 Glow discharge cleaning을 동시에 수행하여 Baking 온도의 낮춤에 따른 영향 평가도 수행하였다.

  • PDF

Single Walled Carbon Nanotubes-Reinforced Metal Matrix Composite Materials Fabricated by Spark Plasma Sintering (방전플라즈마 소결공정으로 제조된 단일벽탄소나노튜브 강화 금속기지 복합재료)

  • Kwon, Hansang
    • Journal of Power System Engineering
    • /
    • v.21 no.4
    • /
    • pp.94-99
    • /
    • 2017
  • Single walled carbon nanotubes were mixed with various metal powders by mechanical ball milling and sintered by spark plasma sintering processes. Two compositional (0.1 and 1 vol%) of the single walled carbon nanotubes were dispersed onto the pure aluminum, 5052 aluminum alloy, pure titanium, Ti6Al4Vanadium alloy, pure copper, and stainless steel 316L. Each composite powders were spark plasma sintered at $600^{\circ}C$ and well synthesized regardless of the matrices. Vickers hardness of the composite materials was measured and they exhibited higher values regardless of the carbon nanotubes composition than those of the pure materials. Moreover, single walled carbon nanotubes reinforced copper matrix composites showed highest enhancement between the other metal matrices system. We believe that low energy mechanical ball milling and spark plasma sintering processes are useful tool for fabricating of the carbon nanotubes-reinforced various metal matrices composite materials. The single walled carbon nanotubes-reinforced various metal matrices composite materials could be used as an engineering parts in many kind of industrial fields such as aviation, transportation and electro technologies etc. However, detail strengthening mechanism should be carefully investigated.

Characterisation of Tensile Deformation through Infrared Imaging Technique

  • B. Venkataraman, Baldev Raj;Mukhophadyay, C.K.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.6
    • /
    • pp.609-620
    • /
    • 2002
  • It is well known that during tensile testing, a part of the mechanical work done on the specimen is transformed into heat energy. However, the ultimate temperature rise and the rate of temperature rise is related to the nature of the material, conditions of the test and also to the deformation behaviour of the material during loading. The recent advances in infrared sensors and image/data processing techniques enable observation and quantitative analysis of the heat energy dissipated during such tensile tests. In this study, infrared imaging technique has been used to characterise the tensile deformation in AISI type 316 nuclear grade stainless steel. Apart from identifying the different stages during tensile deformation, the technique provided an accurate full-field temperature image by which the point and time of strain localization could be identified. The technique makes it possible to visualise the region of deformation and failure and also predict the exact region of fracture in advance. The effect of thermal gradients on plastic flow in the case of interrupted straining revealed that the interruption of strain and restraining at a lower strain rate not only delays the growth of the temperature gradient, but the temperature rise per unit strain decreases. The technique is a potential NDE tool that can be used for on-line detection of thermal gradients developed during extrusion and metal forming process which can be used for ensuring uniform distribution of plastic strain.

Design of Diaphragm for Ultra High Pressure Sensors and Its performance Evaluation Using a PZT Actuated Deformation Tester (초고압 압력센서용 다이어프램 설계 및 PZT 구동 변형시험기를 이용한 성능평가)

  • Yun, Dae Jhoong;Ahn, Jung Hwan
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.58-63
    • /
    • 2019
  • This research aims at designing a diaphragm made of SUS316L stainless steel for ultra high pressure sensors and evaluating its performance with a PZT driven deformation tester instead of high pressure chamber testing up to 100 MPa. Finite element method analysis indicates that the optimum thickness of a flat diaphragm is 1.5 mm not only to secure safety of sensors up to 100 MPa but also to enhance displacement measuring sensitivity. For this thickness, the maximum displacement at the center of the diaphragm is $5.3{\mu}m$. The PZT actuator must offer a force of 1,669 N to create a pressure of 100 MPa at the diaphragm surface in order to obtain a displacement of $5.3{\mu}m$. The performance evaluation by the PZT driven tester demonstrates nearly the same results as the same results as the sensors tested in the ultra high pressure chamber.

Development of the KSTAR Superconductor

  • Lim B.S.;Choi J.Y.;Lee S.I.;Kim D.J.;Park W.W.;Woo I.S.;Song Y.J.;Song N.H.;Kim C.S.;Lee D.G.;Kim K.P.;Park H.T.;Joo J.J.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.2
    • /
    • pp.25-28
    • /
    • 2006
  • The magnet system of KSTAR(korean Superconducting Tokamak Advanced Research) is consisted of 16 TF (Toroidal Field) coils and 14 PF (Poroidal Field) coils. Internal cooling CICC(Cable in Conduit Conductor) type conductor is used for both of TF and PF coil systems. The conduit material for $Nb_3Sn$ cable is Incoloy 908 and 316LN stainless-steel was used as conduit material for NbTi cable. $Nb_3Sn$ CICC is used for all TF coils and PF1-5 coils while NbTi CICC is used for PF6 and 7 coils. $Nb_3Sn$ and NbTi strands were made for KSTAR superconducting strand. They are satisfied with KSTAR superconducotr requirements. The $Nb_3Sn$ strands supplied from three companies; MELCO (Mitsubishi Electric Co.), OAS (Outokumpu Advanced Superconductor) and KAT (Kiswire Advanced Technology) were used. A special CICC jacketing system is developed for the KSTAR CICC fabrication which uses the tube-mill process consisted of forming, welding, sizing and squaring procedures. The. procedures for cabling and jacketing of CICC for TF and PF coils and their results including the geometrical specification and characteristics of strands are described.

Surface characteristics and biocompatibility of bioinert nitrides ion plated titanium implant (생불활성 질화물 이온도금된 티타늄 임프란트의 표면특성 및 생체적합성)

  • Chang, Kap-Sung;Kim, Heung-Joong;Park, Joo-Cheol;Kim, Byung-Ock;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.1
    • /
    • pp.209-231
    • /
    • 1999
  • Even though titanium(Ti) and its alloys are the most used dental implant materials, there are some problems that Ti wears easily and interferes normal osteogenesis due to the metal ions. Ti coated with bioactive ceramics such as hydroxyapatite has also such problems as the exfoliation or resorption of the coated layer, Recent studies on implant materials have been proceeding to improve physical properties of the implant substrate and biocompatibility of the implant surfaces. The purpose of the present study was to examine the physical property and bone tissue compatibility of bioinert nitrides ion plated Ti, Button type specimens(14mm in diameter, 2.32rrun in height) for the abrasion test and cytotoxicity test and thread type implants(3.75mm in diameter, 6mm in length) for the animal experiments were made from Ti(grade 2) and 316LVM stainless steel. Ti specimens were ion plated with TiN, ZrN by the low temperature arc vapor deposition, and the depth profile of the TiN/Ti, ZrN/Ti ion plated surface was examined by Auger Electron Spectroscopy. Three kind of button type specimens .of TiN/Ti, ZrN/Ti and Ti were used for abrasion test, and HEPAlClC7 cells and CCD cells were cultivated for 4 days with the specimens for cytotoxicity test. Thread type implants of TiN/Ti, ZrN/Ti, Ti, 316LVM were implanted on the femur of 6 adult dogs weighing 10kg-13kg. Two dogs were sacrified for histological examination after 45 days and 90 days, and four dogs were sacrified for the removal torque test of the implant') after 90 days. The removal torque force was measured by Autograph (Shimadzu Co., AGS-1000D series, Japan). Abrasion resistance of TiN/Ti was the highest, and that of ZrN/Ti and Ti were followed. The bioinert nitride ion plated Ti had much better abrasion resistance, compared with Ti, In the cytotoxicity test, the number of both cells were increased in all specimens, and there were no significant difference in cytotoxic reaction among all groups (p>0.1), In histological examination, 316LVM showed the soft tissue engagement in interface between the implant and bone, but the other materials after 45 days noted immature new bone formation in the medullary portion along the implant surface, and those after 90 days showed implant support by new bone formation in both the cortical and the medullary portion, The removal torque force of Tilv/Ti showed significantly higher than that of Ti(p(O,05). The difference in removal torque force between TiN/Ti and ZrN/Ti was not significant(p>0.05), and that of 316LVM was lowest among all groups(p<0.05). These results suggest that bioinert nitrides ion plated Ti can resolve the existing problems of Ti and bioactive ceramics, and it may be clinically applicable to human.

  • PDF