• Title/Summary/Keyword: 31-mode

Search Result 782, Processing Time 0.028 seconds

Design of Poly-Silicon Thin Film Transistor Circuits for Driving Liquid Crystal Display and Analysis of Characteristics of the Devices (액정표시기 구동을 위한 다결정 실리콘 박막 트랜지스터 회로의 설계 및 기초소자 특성분석)

  • 허성회;한철희
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.3
    • /
    • pp.39-46
    • /
    • 1994
  • CMOS LCD driving circuits using poly-Si TFT have been designed and basic blocks including test patterns have been fabricated. Column driver drives the pixels by block because polu-Si TFT can not operate at the speed of video signal. Row driver has mode selection circuit which can select a mode between interlacing mode and non-interlacing mode. Experimental results show shift register can operate at 1MHz colck frequency with 4pF load.

  • PDF

Study of the structural damage identification method based on multi-mode information fusion

  • Liu, Tao;Li, AiQun;Ding, YouLiang;Zhao, DaLiang
    • Structural Engineering and Mechanics
    • /
    • v.31 no.3
    • /
    • pp.333-347
    • /
    • 2009
  • Due to structural complicacy, structural health monitoring for civil engineering needs more accurate and effectual methods of damage identification. This study aims to import multi-source information fusion (MSIF) into structural damage diagnosis to improve the validity of damage detection. Firstly, the essential theory and applied mathematic methods of MSIF are introduced. And then, the structural damage identification method based on multi-mode information fusion is put forward. Later, on the basis of a numerical simulation of a concrete continuous box beam bridge, it is obviously indicated that the improved modal strain energy method based on multi-mode information fusion has nicer sensitivity to structural initial damage and favorable robusticity to noise. Compared with the classical modal strain energy method, this damage identification method needs much less modal information to detect structural initial damage. When the noise intensity is less than or equal to 10%, this method can identify structural initial damage well and truly. In a word, this structural damage identification method based on multi-mode information fusion has better effects of structural damage identification and good practicability to actual structures.

Characteristics of Multiplexed Grooved Nozzles for High Flow Rate Electrospray (고유량 정전분무를 위한 다중 홈노즐 특성 연구)

  • Kim, Kyoung-Tae;Kim, Woo-Jin;Kim, Sang-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.10
    • /
    • pp.848-854
    • /
    • 2007
  • The electrospray operated in the cone-jet mode can generate highly charged micro droplets in an almost uniform size at low flow rates. Therefore, the multiplexing system which can retain the characteristics of the cone-jet mode is inevitable for the electrospray application. This experiment reports the multiplexed grooved nozzle system with the extractor. The effects of the grooves and the extractor on the performance of the electrospray were evaluated through experiments. Using the grooved nozzle, the stable cone-jet mode can be achieved at the each groove in the grooved mode. Furthermore, the number of nozzles per unit area is increased by the extractor. The multiplexing density is 12 jets per $cm^2$ at 30 mm distance from the nozzle tip to the ground plate. The multiplexing system for the high flow rate electrospray is realized with the extractor which can diminish the space charge effect without sacrificing characteristics of the cone-jet mode.

Fatigue Strength Evaluation of Self-Piercing Riveted Al 5052-H32 Joints under Mixed Mode Loading Conditions (혼합모드상태에서의 Al 5052-H32 셀프 피어싱 리벳 접합부의 피로강도 평가)

  • Kwak, Jin Gu;Kang, Se Hyung;Kim, Ho Kyung
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.1-7
    • /
    • 2016
  • In this study, static and fatigue tests on the self-piercing riveted (SPR) joint were conducted using cross-shaped specimens with aluminum alloy (Al-5052) sheets. Mixed mode loading was achieved by changing the loading angles of 0, 45, and 90 degrees using a special fixture to evaluate the static and fatigue strengths of the SPR joints under mixed mode loading conditions. Simulations of the specimens at three loading angles were carried out using the finite element code ABAQUS. The fatigue specimens failed in an interfacial mode where a crack initiated at the upper sheet and propagated along the longitudinal direction and finally fractured Maximum principal stress, von-Mises effective stress failed to correlate the fatigue lifetimes at three loading angles. However, the equivalent stress intensity factor was found to be appropriate to correlate the fatigue lifetimes at three loading angles.

Usefulness of Twinkling Artifacts in Color Doppler Ultrasonography (컬러 도플러 초음파에서 Twinkling artifacts의 유용성)

  • Sim, Hyun-Sun;Kwon, Kyung-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.10
    • /
    • pp.291-298
    • /
    • 2016
  • The aim of the study was to investigate the diagnostic value of the color Doppler twinkling artifact in disease of urinary system. The intensity of twinkling artifact(TA) with color Doppler was classified into 3 levels, 0(non-TA) to 3(distinct TA). In the in vitro study, acorn jelly with various materials on top was examined using color Doppler at B-mode sonography in a water bath for TA. 31 patients with diagnosis of urinary calculi(renal stones 16, urinary stones 15) based on B-mode sonography were studied in vivo for TA. The materials with rough surfaces such as salt, screw and cubics at B-mode sonography with color Doppler contributed to causing TA. At B-mode sonography without color Doppler 37% of renal stones and 60% of ureter stones were detected. but at B-mode sonography with color Doppler TA was demonstrated for all cases. Superficial roughness of materials affected occurrence of TA at B-mode sonography with color Doppler. Therefore, TA at B-mode sonography without color Doppler could play a role in confident diagnosis of the disease of urinary system.

Finite Element Analysis of Capacitive pressure sensor with Touch mode for improving non-linearity (비선형성의 개선을 위한 Capacitive pressure sensor의 Touch mode 방식에 대한 유한요소 해석)

  • Kim, Do-Hyung;O, Jea-Geun;Choi, Bum-Kyoo
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.2087-2089
    • /
    • 2004
  • Capacitive pressure sensor는 Piezo type sensor에 비해 온도의 영향이 적어 공업계측, 전기용품 등 그 용도가 다양하여 폭넓게 사용되어지고 있지만, 측정값의 비선형성이 존재하여 측정값에 대한 신뢰도가 떨어지는 단점이 있다. 본 연구에서는 기존 capacitive pressure sensor의 비선형적 output을 개선하기 위한 방법으로 touch mode capacitive pressure sensor를 제안하였다. 또한, 실제 Device제작에 앞서 FEM 해석을 수행하였다. 2mm X 2mm 크기의 diaphragm, $25{\mu}m$의 두께, $20{\mu}m$의 gap을 갖는 Sensor를 Simulation하였으며 설계 변수를 추출하여 각각의 설계변수에 대한 해석을 실시하였다. 그 결과 15.2psi${\sim}$31psi의 영역에서 8.58pF${\sim}$54.31pF의 capacitance가 선형적으로 나타나는 sensor임을 확인하였다.

  • PDF

DFT Study for Azobenzene Crown Ether p-tert-Butylcalix[4]arene Complexed with Alkali Metal Ion

  • Park, Seong-Jun;Choe, Jong-In
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.3
    • /
    • pp.541-545
    • /
    • 2008
  • Stable molecular isomers were calculated for the azobenzene crown ether p-tert-butylcalix[4]arene (1) in the host and their alkali-metal-ion complexes. The structures of two distinct isomers (cis and trans) have been optimized using DFT B3LYP/6-31G(d,p) method. Trans isomer of 1 is found to be 11.69 kcal/mol more stable than cis analogue. For two different kinds of complexation mode, the alkali-metal-cation in the crown-ether moiety (exo) has much better complexation efficiency than in the benzene-rings (endo) pocket for both isomers of 1. Sodium ion has much better complexation efficiency than potassium ion in all kinds of complexation mode with host 1. The Na+ complexation efficiency of the trans-complex (1) in the exo-binding mode is 8.24 kcal/mol better than cis-exo analogue.

Cobalt(III) Complexes of Various Salen-Type Ligand Bearing Four Quaternary Ammonium Salts and Their Reactivity for CO2/Epoxide Copolymerization

  • Kim, Bo-Eun;Varghese, Jobi Kodiyan;Han, Yong-Gyu;Lee, Bun-Yeoul
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.4
    • /
    • pp.829-834
    • /
    • 2010
  • Ligand variation was carried out on a cobalt(III) complex of Salen-type ligand comprised of 1,2-cyclohexenediamine and salicylaldehyde bearing a methyl substituent on 3-position and -[$CMe(CH_2CH_2CH_2N^+Bu_3)_2$] on 5-position, which is a highly active catalyst for $CO_2$/propylene oxide copolymerization. Replacement of the methyl substituent with bulky isopropyl group resulted in alteration of the binding mode, consequently lowering turnover frequency significantly. Replacement with an ethyl group preserved binding mode and activity. Replacement of the tributylammonium unit with trihexylammonium or trioctylammonium, or replacement of 1,2-cyclohexenediamino unit with -$NC(Me)_2CH_2N$- decreased activity, even though the binding mode was unaltered.

A Study on the 3-D Simulation of Contour Vibration Mode Piezoelectric Transformer (윤곽진동모드 압전트랜스포머의 3차원 시뮬레이션에 관한 연구)

  • 홍재일;류주현;정영호;박창엽;김종선;유충식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.423-426
    • /
    • 2000
  • The 3-D $31.5$\times$31.5$\times$2.5mm$^3$model of contour vibration mode piezoelectric transformer with Pb($Ni_{1/2}$$W_{1/2}$)$O_3$-Pb(Zr,Ti)$O_3$ ceramics was simulated by ANSYS according to the dot size 17, 18, 19, 20, 21 $mm\phi$ and analyzed the results. The mechanical quality factor of the 3-D model was decreased with the dot size and increased as 2605 at 20 $mm\phi$ and after then decreased again. The output voltage of that sample was 74123 [V] and the maximum stress of the dot electrode at that sample was 288[$10^7$N/$m^2$] and the maximum displacement of the ring electrode at that sample was 128 [$\mu\textrm{m}$].

  • PDF

Validity assessment of aspect ratios based on Timoshenko-beam model: Structural design

  • Emad Ghandourah;Muzamal Hussain;Mohamed A. Khadimallah;Mashhour Alazwari;Mohamed R. Ali;Mohammed A. Hefni
    • Computers and Concrete
    • /
    • v.31 no.1
    • /
    • pp.1-7
    • /
    • 2023
  • In this paper, Timoshenko-beam model is developed for the vibration of double carbon nanotubes. The resulting frequencies are gained for axial wave mode and length-to-diameter ratios. The natural frequency becomes more prominent for lower length-to-diameter ratios and diminished for higher ratios. The converse behavior is observed for axial wave mode with clamped-clamped and clamped-free boundary conditions. The frequencies of clamped-free are lower than that of clamped-clamped boundary condition. The eigen solution is obtained to extract the frequencies of double walled carbon nanotubes using Galerkin's method through axial deformation function. Computer softer MATLAB is used for formation of frequency values. The frequency data is compared with available literature and found to be in agreement.