• Title/Summary/Keyword: 3-winding transformer

Search Result 120, Processing Time 0.022 seconds

Characteristic Analysis of Flyback Type ZVS PWM DC-DC Converter Using Passive Resonant Snubber (패시브 공진 스너버를 이용한 플라이백형 ZVS PWM DC-DC 컨버터의 특성해석)

  • Kim, Jung-Do;Mun, Sang-Pil;Park, Han-Seok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.3
    • /
    • pp.158-164
    • /
    • 2016
  • In this paper, a high frequency flyback type zero voltage soft switching PWM DC-DC converter using IGBTs is proposed. Effective applications for this power converter can be found in auxiliary power supplies of rolling stock transportation and electric vehicles. This power converter is basically composed of active power switches and a flyback high frequency transformer. In addition to these, passive lossless snubbers with power regeneration loops for energy recovery, consisting of a three winding auxiliary high frequency transformer, auxiliary capacitors and diodes are introduced to achieve zero voltage soft switching from light to full load conditions. Furthermore, this power converter has some advantages such as low cost circuit configuration, simple control scheme and high efficiency. Its operating principle is described and to determine circuit parameters, some practical design considerations are discussed. The effectiveness of the proposed power converter is evaluated and compared with the hard switching PWM DC-DC converter from an experimental point of view and the comparative electromagnetic conduction and radiation noise characteristics of both DC-DC power converter circuits are also depicted.

Analysis of the Damage Patterns and Metal Structure of 3 Phase Mold Transformers to which Interlayer Short-circuits have Occurred (층간 단락된 3상 몰드변압기의 소손 패턴 및 금속 조직 해석)

  • Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.86-91
    • /
    • 2010
  • The purpose of this study is to analyze the damage patterns and metal structure of 3 phase mold transformers collected from places where accidents have occurred. Compared to an oil-immersed transformer, a mold transformer has the advantage of requiring a smaller installation area and can be kept clean, while its disadvantages include the fact that abnormal symptoms of an accident are difficult to discover and its repair is impossible. The capacity of the mold transformers collected from places where accidents have occurred was 200kVA with primary voltages being F23,900V, R22,900V, 21,900V, 20,900V, 19,900V, etc., as well as secondary voltages being 380V, 220V, etc. It was found from the analysis on the diffusion of combustion in the damaged mold transformers that fire occurred first inside the U-phase primary winding and that carbonization and heat were diffused to V-phase and W-phase in V-pattern. In addition, from the analysis on the cross-sectional structure of the metal of the melted high voltage winding using a metallurgical microscope, it was found that the boundary surface, voids, and columnar structure were formed when an interlayer short-circuit had occurred Therefore, even though it is not possible to find the cause for the occurrence of an interlayer short-circuit at the inner side of the primary winding, it is thought that, due to the thermal energy generated when the short-circuit occurred, the heat source was diffused to the upper side and outside, causing a secondary accident.

Assessment of Insulation Condition in Large Transformers (대형변압기 절연상태 평가)

  • Kim, Hee-Dong;Kong, Tae-Sik;Lee, Young-Jun;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.499-502
    • /
    • 2004
  • In order to detect of insulation problems an early, transformer has to be performed the several tests. The ac current and tan6 of transformer winding insulation were investigated by Schering bridge. Partial discharge(PD) tests are used to evaluate the insulation condition of transformer. The moisture content measurement was conducted using RVM(recovery voltage meter). The RVM test can show that the problem is affecting the paper insulation of transformer. The value of moisture content was 2.3% in main transformer. The insulations of four transformers were judged to be in good condition.

  • PDF

Protective Algorithm for Transformer Using Nuro-Fuzzy (뉴로-퍼지를 이용한 변기 보호 알고리즘)

  • Lee, Myoung-Rhun;Lee, Jong-Beom;Hong, Dong-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.299-302
    • /
    • 2002
  • The second harmonic component is commonly used for blocking differential relay in Power transformers. However it is difficult to distinguish between inrush and internal winding fault with differential current protective relaying. This paper proposed a new method using nuro-fuzzy. The used data in nuro-fuzzy algorithm are 3-phase primary voltage and fundamental harmonic of differential current. Various states of transformer are simulated using BCTRAN and HYSDAT of EMTP. As a result of applying the algorithm in various cases, the correct discrimination between internal winding fault and inrush performed.

  • PDF

Protecive Algorithm for Transformer Using Nuro-Fuzzy System based on HCM (HCM기반 뉴로-교지 시스템을 이용한 변압기 보호 알고리즘)

  • Lee, Myoung-Rhun;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.552-554
    • /
    • 2003
  • The second harmonic component is commonly used for blocking differential relay in power transformers. However, it is difficult to distinguish between inrush and internal winding fault with differential current protective relaying. This paper proposed a new method using Nuro-Fuzzy System based on HCM(Hard C-Means). The proposed system is more objective and systematic than existing model. The data used in input are 3-phase primary voltage and fundamental harmonic of differential current. Various states of transformer are simulated using BCTRAN and HYSDAT of EMTP. As a result of the application of algorithm in various cases, the exact discrimination between internal winding fault and inrush is performed.

  • PDF

Analysis of Leakage Inductance for Toroidal Type Flyback Transformer (토로이달 타입 플라이백 변압기의 누설 인덕턴스 해석)

  • Park, Chang-Soo;Kang, Byeong-Geuk;Shin, Kyoung-Gu;Chung, Se-Kyo
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.180-181
    • /
    • 2013
  • This paper represents an analysis of a leakage inductance for a toroidal type flyback transformer. The equation to calculate the leakage inductance is derived using its MMF diagram. The analysis for the different types of the cores and winding structures is also provided using the Maxwell 3D simulation. The winding structures minimizing the leakage inductance are finally discussed, from the simulation results.

  • PDF

Analysis on Thermal Transfer Characteristics of 50 kVA Mold-Transformer (50[kVA] 몰드변압기 권선부의 열전달 특성 해석)

  • 이현진;정중일;허창수;조한구
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.3
    • /
    • pp.47-54
    • /
    • 2002
  • This paper presented the charcteristic of the thermal transfer in a 50[kVA] cast-resin dry type transformer. The conductivity of the primary winding composed were a Plenty of epoxy-resin ard a little of Cu was determined by that rating. Otherwise the conductivity of the secondary winding composed of a plenty of Cu and a little of epoxy-resin was determined by comparing the data of analysis using FEM method with those of temperature tests of the prototype cast-resin transformer. Based on the reults of the physical characteristics and the simulation by commercial using FEM method we established the prototype Model for this test. According to that Model, an analysis on variation of the temperature was discussed as a function of ambient temperature and velocities in the 50[kVA] cast-resin dry type transformer.

Optimal Design of High Frequency Transformer for 150W Class Module-Integrated Converter

  • Yoo, Jin-Hyung;Jung, Tae-Uk
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.288-294
    • /
    • 2015
  • Recently, the module-integrated converter has shown an interest in the photovoltaic generation system. In this system, the high frequency transformer should be compact and efficient. The proposed method is based on the correlation characteristic between the copper and core loss to minimize the loss of transformer. By sizing an effective cross-sectional area and window area of core, the amount of loss is minimized. This paper presents the design and analysis of high frequency transformer by using the 3D finite element model coupled with DC-DC converter circuit for more accurate analysis by considering the nonlinear voltage and current waveforms in converter circuit. The current waveform in each winding is realized by using the ideal DC voltage source and switching component. And, the thermal analysis is performed to satisfy the electrical and thermal design criteria.

Characteristic Analysis of a Three Phase HTS Transformer (3상 고온초전도 변압기의 특성해석)

  • Lee, S.W.;Lee, H.J.;Cha, G.S.;Lee, J.K.;Choi, K.D.;Ryu, K.W.;Hahn, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.720-722
    • /
    • 2001
  • The high temperature superconductor transformer gains interests from the industries. This paper examined characteristics of the laboratory scale three phase HTS transformer and Brandt equation is used to calculate the loss by perpendicular magnetic field in transformer winding. To estimate the performance of the three phase HTS transformer no load characteristics, short circuit characteristics are calculated by using finite element method. Transient characteristics of sudden short circuit during full load operation have been examined. Effect of the resistance growth in the HTS wire from the quench of the wire is included in the calculation.

  • PDF

Internal Fault Classification in Transformer Windings using Combination of Discrete Wavelet-Transforms and Back-propagation Neural Networks

  • Ngaopitakkul Atthapol;Kunakorn Anantawat
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.3
    • /
    • pp.365-371
    • /
    • 2006
  • This paper presents an algorithm based on a combination of Discrete Wavelet Transforms and neural networks for detection and classification of internal faults in a two-winding three-phase transformer. Fault conditions of the transformer are simulated using ATP/EMTP in order to obtain current signals. The training process for the neural network and fault diagnosis decision are implemented using toolboxes on MATLAB/Simulink. Various cases and fault types based on Thailand electricity transmission and distribution systems are studied to verify the validity of the algorithm. It is found that the proposed method gives a satisfactory accuracy, and will be particularly useful in a development of a modern differential relay for a transformer protection scheme.