• Title/Summary/Keyword: 3-parameter Transformation

Search Result 94, Processing Time 0.031 seconds

A frame work for heat generation/absorption and modified homogeneous-heterogeneous reaction in flow based on non-Darcy-Forchheimer medium

  • Hayat, Tasawar;Ahmad, Salman;Khan, Muhammad I.;Khan, Muhammad I.;Alsaedi, Ahmed
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.389-395
    • /
    • 2018
  • The present work aims to report the consequences of Darcy-Forchheimer medium in flow of Cross fluid model toward a stretched surface. Flow in porous space is categorized by Darcy-Forchheimer medium. Further heat transfer characteristics are examined via thermal radiation and heat generation/absorption. Transformation procedure is used. The arising system of nonlinear ordinary differential equations is solved numerically by means of shooting method. The effects of different flow variables on velocity, temperature, concentration, skin friction, and heat transfer rate are discussed. The obtained outcomes show that velocity was enhanced with the increase in the Weissenberg number but decays with increase in the porosity parameter and Hartman number. Temperature field is boosted by thermal radiation and heat generation; however, it decays with the increase in the Prandtl number.

Video Augmentation of Virtual Object by Uncalibrated 3D Reconstruction from Video Frames (비디오 영상에서의 비보정 3차원 좌표 복원을 통한 가상 객체의 비디오 합성)

  • Park Jong-Seung;Sung Mee-Young
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.4
    • /
    • pp.421-433
    • /
    • 2006
  • This paper proposes a method to insert virtual objects into a real video stream based on feature tracking and camera pose estimation from a set of single-camera video frames. To insert or modify 3D shapes to target video frames, the transformation from the 3D objects to the projection of the objects onto the video frames should be revealed. It is shown that, without a camera calibration process, the 3D reconstruction is possible using multiple images from a single camera under the fixed internal camera parameters. The proposed approach is based on the simplification of the camera matrix of intrinsic parameters and the use of projective geometry. The method is particularly useful for augmented reality applications to insert or modify models to a real video stream. The proposed method is based on a linear parameter estimation approach for the auto-calibration step and it enhances the stability and reduces the execution time. Several experimental results are presented on real-world video streams, demonstrating the usefulness of our method for the augmented reality applications.

  • PDF

Synthesis of Mullite Powder from Alkoxides and the Properties of the Mullite-Zircocnia Composites (알콕사이드로부터 Mullite 분말의 합성 및 Mullite-Zirconia 복합체의 특성)

  • 함종근;이홍림
    • Journal of the Korean Ceramic Society
    • /
    • v.27 no.2
    • /
    • pp.201-210
    • /
    • 1990
  • The mullite-15v/o ZrO2 composites were prepared by dispersing ZrO2-3m/o Y2O3 powders into the mullite matrix in order to improve the mechanical properties of the mullite. The densification and retention of t-ZrO2 in the matrix of synthetic mullite were also investigated. From IR spectroscopic analysis, the obtained amorphous SiO2-Al2O3 powder was observed to have Si-O-Al chemical bond in its structure which might result in the homogeneous mullite composition. The lattice parameter of the mullite powder calcined above 130$0^{\circ}C$ (a0=7.5468$\AA$) is nearly close to the value of stoichiometric mullite (71.8wt% Al2O3, a0=7.5456$\AA$). The sintering behavior, microstructure, flexural strength and fracture toughness of the mullite and mullite-15v/o ZrO2 composites have been studied. The mullite-15v/o ZrO2(+3m/o Y2O3) ceramics with relative densities of 96% were obtained when sintered at 1$600^{\circ}C$. The flexural strength and fractrue toughness of the composites sintered at 1$600^{\circ}C$(calcination temperature of mullite powders ; 125$0^{\circ}C$) had maximum values of 307MPa and 2.50MPa.m1/2, respectively. The fracture toughness improvement in the mullite-ZrO2 cmoposite is assumed to be resulted from the combined effect of the stress-induced phase transformation of tetragonal ZrO2 and the crack deflection due to microcracking by the monoclinic ZrO2 formation.

  • PDF

The Determination of Optimum Beam Position and Size in Radiation Treatment (방사선치료시 최적의 빔 위치와 크기 결정)

  • 박정훈;서태석;최보영;이형구;신경섭
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.49-57
    • /
    • 2000
  • New method about the dose optimization problem in radiation treatment was researched. Since all conditions are more complex and there are more relevant variables, the solution of three-dimensional treatment planning is much more complicate than that of current two-dimensional one. There(ore, in this study, as a method to solve three-dimensional dose optimization problem, the considered variables was minized and researched by reducing the domain that solutions can exist and pre-determining the important beam parameters. First, the dangerous beam range that passes critical organ was found by coordinate transformation between linear accelerator coordinate and patient coordinate. And the beam size and rotation angle for rectangular collimator that conform tumor at arbitrary beam position was also determined. As a result, the available beam position could be reduced and the dependency on beam size and rotation angle, that is very important parameter in treatment planning, totally removed. Therefore, the resultant combinations of relevant variables could be greatly reduced and the dose optimization by objective function can be done with minimum variables. From the above results, the dose optimization problem was solved for the two-dimensional radiation treatment planning useful in clinic. The objective function was made by combination of dose gradient, critical organ dose and dose homogeniety. And the optimum variables were determined by applying step search method to objective function. From the dose distributions by optimum variables, the merit of new dose optimization method was verified and it can be implemented on commercial radiation treatment planning system with further research.

  • PDF

Geodesics-based Shape-preserving Mesh Parameterization (직선형 측지선에 기초한 원형보전형 메쉬 파라미터화)

  • 이혜영
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.7
    • /
    • pp.414-420
    • /
    • 2004
  • Among the desirable properties of a piecewise linear parameterization, guaranteeing a one-to-one mapping (i.e., no triangle flips in the parameter plane) is often sought. A one-to-one mapping is accomplished by non-negative coefficients in the affine transformation. In the Floater's method, the coefficients were computed after the 3D mesh was flattened by geodesic polar-mapping. But using this geodesic polar map introduces unnecessary local distortion. In this paper, a simple variant of the original shape-preserving mapping technique by Floater is introduced. A new simple method for calculating barycentric coordinates by using straightest geodesics is proposed. With this method, the non-negative coefficients are computed directly on the mesh, reducing the shape distortion introduced by the previously-used polar mapping. The parameterization is then found by solving a sparse linear system, and it provides a simple and visually-smooth piecewise linear mapping, without foldovers.

A Study on the Factors of Fenton-oxidation of MTBE in Water and Soil (Fenton-oxidation에 의한 MTBE(Methyl Tertiary Butyl Ether)처리시의 영향인자에 관한 연구)

  • 전은미;박석환;정문식
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.3
    • /
    • pp.63-69
    • /
    • 1998
  • The treatment of soils and water contaminated with MTBE using the Fenton oxidation was investigated. The effects of dosage of $H_{2}O_{2}$, and Fe$^{2+}$ concentrations, and solution pH on transformation and mineralization in soil were evaluated. Generation of TBA and acetone following Fenton-oxidation of MTBE in water and generation of acetone following Fenton-oxidation of TBA were observed. Therefore TBA and acetone are degradation intermediates of MTBE. There was a large difference of treatment efficiency in Fenton oxidation of MTBE between soil and water system. This may be caused by the complex nature of soil, soil organic matter which can consumed OH $\cdot$ radicals, and interacting with inorganic-soil constituents. The pH of soil was observed to have a significant effect on the chemical oxidation efficient of MTBE in soil The data demonstrated that optimal pH range were pH 3~4 and around 6. The soil batch studies demonstrated that treatment efficiency of MTBE was enhanced by adding additional ferrous salts but Fenton-oxidation occurred in no additional iron which indicated that iron in soil can catalyze the Fenton-oxidation. The most effective parameter of Fentonoxidation was $H_{2}O_{2}$/Fe$^{2+}$ ratio which theocratical ratio is 0.5. The optimal range of this ratio was found to be 0.6~2.3. In evaluating effect of $H_{2}O_{2}$ dosage on treatment efficiency, the increase of $H_{2}O_{2}$ did not always lead to increase of decompositions of MTBE in soil. Fenton oxidation was effective in destroying MTBE in aqueous extracts of contaminated soil and water. Experimental data provided evidence that the Fenton oxidation can effectively remediate MTBE-contaminated water and soil.

  • PDF

A Study on the Cover Property of Offshore Reinforced Concrete Structure (내구성 해양 RC 구조물의 철근 피복적정성에 관한 연구)

  • Im, Jung-Soon;Bahng, Yun-Suk;Jo, Jae-Byung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.3 s.14
    • /
    • pp.73-81
    • /
    • 2004
  • On this study, durability decreasing element caused by salt damage was analyzed elementally and studied with the data of the inside and outside in the country. The design strength and water-cement ratio according to diffusion coefficients of chloride were applied to Fick's diffusion equation. The required over depended on environmental conditions is estimated with endurance period, and the influences on cover according to the transformation of the each parameter were investigated. In consequence, if water-cement ratio decreases and design strength increases, it shows that slowing infiltration velocity of chloride ion can decrease required cover. Especially, it is more effective to use Portland blast-furnace slag cement into high strength concrete in the splash zone environmental conditions in blocking the diffusion of chloride ion. As the result, in the case of the offshore concrete structure needed high durability, it is needed to increase cover($3cm{\sim}8cm$) than minimum standard cover(8cm) according to environmental conditions.

Active Frequency with a Positive Feedback Anti-Islanding Method Based on a Robust PLL Algorithm for Grid-Connected PV PCS

  • Lee, Jong-Pil;Min, Byung-Duk;Kim, Tae-Jin;Yoo, Dong-Wook;Yoo, Ji-Yoon
    • Journal of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.360-368
    • /
    • 2011
  • This paper proposes an active frequency with a positive feedback in the d-q frame anti-islanding method suitable for a robust phase-locked loop (PLL) algorithm using the FFT concept. In general, PLL algorithms for grid-connected PV PCS use d-q transformation and controllers to make zero an imaginary part of the transformed voltage vector. In a real grid system, the grid voltage is not ideal. It may be unbalanced, noisy and have many harmonics. For these reasons, the d-q transformed components do not have a pure DC component. The controller tuning of a PLL algorithm is difficult. The proposed PLL algorithm using the FFT concept can use the strong noise cancelation characteristics of a FFT algorithm without a PI controller. Therefore, the proposed PLL algorithm has no gain-tuning of a PI controller, and it is hardly influenced by voltage drops, phase step changes and harmonics. Islanding prediction is a necessary feature of inverter-based photovoltaic (PV) systems in order to meet the stringent standard requirements for interconnection with an electrical grid. Both passive and active anti-islanding methods exist. Typically, active methods modify a given parameter, which also affects the shape and quality of the grid injected current. In this paper, the active anti-islanding algorithm for a grid-connected PV PCS uses positive feedback control in the d-q frame. The proposed PLL and anti-islanding algorithm are implemented for a 250kW PV PCS. This system has four DC/DC converters each with a 25kW power rating. This is only one-third of the total system power. The experimental results show that the proposed PLL, anti-islanding method and topology demonstrate good performance in a 250kW PV PCS.

Parameters Study of Linear Reservoir Models for Rainfall-Runoff Response (강우-유출에 대한 선형저수지 모형의 매개변수 연구)

  • Seo, Yeong-Je;Kim, Jin-Gyu;Park, Hyeon-Ju
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.6
    • /
    • pp.711-720
    • /
    • 1999
  • In this study, a various rainfall-runoff modelling approaches have been applied to the runoff response of flood hydrograph in three experimental watershed of the western part of korea. Mathematical models of runoff response also have been studied including linear system theory based on modeling techniques. Eight models were operated at the five water level gauging stations and the parameters of each model were computed by the Rosenbrock's hill climbing method to minimize the objective function. For the parameter verification of the models, a different complex rainfall-runoff event was selected in the same of the three river basins and derived IUH of the each model could be calibrated. Furthermore multiple regressions of the logarithmic transformation method between model parameters and catchment characteristics were studied in the selected five station.

  • PDF

ON THE COARSE-GRAINNING OF HYDROLOGIC PROCESSES WITH INCREASING SCALES

  • M. Levent Kavvas
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 1998.05b
    • /
    • pp.3-3
    • /
    • 1998
  • In this pressentation it is argued that the heterogeneity of a hydrologic attribute which may seem to be nonstationary at one scale, may become stationary at a larger scale. The fundamental reason for transformation from nonstationarity to stationarity whith the increase in scale is the phenomenon of coarse-graining of the hydrologic processes with increasing scale. Due to the phenomenon of aliasing, a particular scale hydrologic process heterogeneity which is observed as a nonstationary process at that scale, may be observed as a stationary process at a higher(larger) scale whose size is bigger than the stationary extent of the lower scale heterogeneity. As one goes through a hierarchical sequence of larger and larger scales for observations, one would eliminate nonstationarities which emerge at some lower scales at the expense of losing information on the high frequency fluctuations of the lower scale heterogeneities which will no longer be observed at the larger sampling scales. We call this phenimenon as the "coarse-graining in hydrologic observations". In this presentation, it is also argued that by the coarse-graining of hydrologic processes due to the averaging and aliasing operations at increasing scales, the conservation laws corresponging to these scales may still be quite parsimonious, and need not be more complicated as the scales get larger. It is shown that shen a higher(larger) scale process is formed by averaging a lower(smaller) scale process in time or space, the high frequency components of the lower scale process will be eliminated by the averaging operation. Thereby, the resuliiting average hydrologic dynamics, free from the effects of the high frequency components of the lower scale process, can still be quite simple in form. This is demonstrated by means of some recent upscaling work on the solute teansport conservation equation for hetergeneous aquifers. By means of this solute transport example, it is also shown that for the ensemble average form of a hydrologic conservation equation to be equivalent to its volume-average form at any scale, the parameter functions of that conservation equation at the immediately lower scale must be ergodic.

  • PDF