• Title/Summary/Keyword: 3-line detector

Search Result 137, Processing Time 0.029 seconds

Discussion of Preliminary Design Review for MIRIS, the Main Payload of STSAT-3

  • Han, Won-Yong;Jin, Ho;Park, Jang-Hyun;Nam, Uk-Won;Yuk, In-Soo;Lee, Sung-Ho;Park, Young-Sik;Park, Sung-Jun;Lee, Dae-Hee;Ree, Chang-H.;Jeong, Woong-Seob;Moon, Bong-Kon;Cha, Sang-Mok;Cho, Seoung-Hyun;Rhee, Seung-Woo;Park, Jong-Oh;Lee, Seung-Heon;Lee, Hyung-Mok;Matsumoto, Toshio
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.27.1-27.1
    • /
    • 2008
  • KASI (Korea Astronomy and Space Science Institute) is developing a compact wide-field survey space telescope system, MIRIS (The Multi-purpose IR Imaging System) to be launched in 2010 as the main payload of the Korea Science and Technology Satellite 3. Through recent System Design Review (SDR) and Preliminary Design Review (PDR), most of the system design concept was reviewed and confirmed. The near IR imaging system adopted short F/2 optics for wide field low resolution observation at wavelength band 0.9~2.0 um minimizing the effect of attitude control system. The mechanical system is composed of a cover, baffle, optics, and detector system using a $256\times256$ Teledyne PICNIC FPA providing a $3.67\times3.67$ degree field of view with a pixel scale of 51.6 arcsec. We designed a support system to minimize heat transfer with Muti-Layer Insulation. The electronics of the MIRIS system is composed of 7 boards including DSP, control, SCIF. Particular attention is being paid to develop mission operation scenario for space observation to minimize IR background radiation from the Earth and Sun. The scientific purpose of MIRIS is to survey the Galactic plane in the emission line of Pa$\alpha$ ($1.88{\mu}m$) and to detect the cosmic infrared background (CIB) radiation. The CIB is being suspected to be originated from the first generation stars of the Universe and we will test this hypothesis by comparing the fluctuations in I (0.9~1.2 um) and H (1.2~2.0 um) bands to search the red shifted Lyman cutoff signature.

  • PDF

THE EFFECT OF THE GENISTEIN ON THE PROLIFERATION OF HT1080 AND EXPRESSION OF MEMBRANE TYPE 1-MATRIX METALLOPROTEINASE (MT1-MMP) mRNA (Genistein이 사람 섬유육종 세포주 증식 및 Membrane Type 1-Matrix Metalloproteinase (MT1-MMP) mRNA 발현에 미치는 영향)

  • Kang, Jin-Han;Myoung, Hoon;Kim, Myung-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.4
    • /
    • pp.314-320
    • /
    • 2001
  • Matrix metalloproteinases have long been viewed as ideal candidates for proteinases that enables tumor cells to permeated basement membrane defenses and invade surrounding tissue. There is growing evidence that the MMPs have an expanded role, as they are important for the creation and maintenance of a microenvironment that facilitates growth and angiogenesis of tumors at primary and metastatic sites. MT-MMPs are not secreted but instead remaining attached to cell surfaces. Although not all of the MT-MMPs are fully characterized, MT-MMPs have important role in localizing and activating secreted MMPs. The MMP genes are transcriptionally responsive to a wide variety of oncogene, growth factors, cytokine, and hormones. Currently, a number of MMP inhibitors are being developed and some have reached clinical trials as anti-metastatic or anti-cancer therapies. MT1-MMP is involved in the activation of proMMP-2. MT1-MMP is significant not only as a tumor marker but as a new target for chemotherapy against cancer. The purpose of this study was to evaluate the effects of protein kinase C inhibitor(genistein) on the proliferation of HT1080 and expression of MT1-MMP mRNA. Human fibrosarcoma cell line HT1080 was cultured and divided 2 groups. The experimental group was treated with $100{\mu}M$ genistein and incubated 12h, 24h for $[3^H]-thymidine$ uptake assay and northern hybridization individually. And the control group was treated with same amount of PBS for the above procedures. $[3^H]-thymidine$ incorporation was measured with ${\beta}$ ray detector. And RT-PCR and northern blotting for MT1-MMP mRNA was performed. The results were as follows 1. $[3^H]-thymidine$ uptake was reduced in experimental group with statistical significance. 2. MT1-MMP mRNA expression was significantly reduced in experimental group. These results showed that protein kinase C inhibitor (genistein) inhibited proliferation of HT1080 and almost completely blocked transcription of MT1-MMP mRNA. So, it is possible to use the protein kinase inhibitor (genistein) as anti-metastatic and anti-proliferative agent.

  • PDF

Analysis of Fatty Acid in Rice Bran Oil by Gas Chromatography (Gas Chromatography에 의(依)한 미강유(米糠油)의 지방산분석(脂肪酸分析))

  • Chung, T.M.;Shin, J.S.
    • Applied Biological Chemistry
    • /
    • v.9
    • /
    • pp.29-33
    • /
    • 1968
  • Through an experiment with gas chromatography carried out using diethylene glycol succinate(DEGS) as the packing material of the column, we have obtained the correction factor between the weight ratio and the peak dimension of the saturated fatty acid methyl esters of C10, C12, C14, C16, and C18 and unsaturated fatty acid methyl esters of oleic acid, linoloic acid, and linolenic acid, employing the detector of thermal conductivity type. Quantitative analysis of the fatty acids contained in rice Bran oil was performed with the above correction factor and the results are as follows; 1. Main components were found to be palmitic acid, oleic acid sand linolenic acid. No trases of capric acid (C10) lauric acid (C10) were found. 2. It was confirmed that there were straight line relation between the logarism retention time of each fatty acid and the number of carbon of saturated fatty acid or the number of double bond of other fatty acids having the same number of carbon. 3. The correction factor became larger as to the number of carbon increased up to C18 in case of saturated fatty acids, end as for other fatty acids, and as for other fatty acids of the same carbon number, it became larger according as the number of double bond increased.

  • PDF

Validation Study for Image Performance of I-131 Using GATE Simulation Program (GATE 시뮬레이션 프로그램을 이용한 I-131의 영상 특성의 타당성에 관한 연구)

  • Baek, Cheol-Ha;Kim, Dae Ho;Lee, Yong-Gu;Lee, Youngjin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.5
    • /
    • pp.133-137
    • /
    • 2017
  • The purpose of this study was to validate for GATE (Geant4 Application for Tomographic Emission) simulation by comparing the results of GATE simulation and experiment in real SPECT system. Futhermore, we want to prove that it is possible that the quantitative research of gamma camera/SPECT imaging for therapeutic radio isotope by using GATE simulation. In this study, the SPECT system on simulation referred to the parameters of Stream-R Forte version 1.2 (Philips Medical System, Best and Heerlen, Netherlands). To understand the I-131 image of gamma camera/SPECT system, we acquired the energy spectrum and measured the full width at half maximum (FWHM) which comes from line spread function (LSF) with and without scatter material in real SPECT system. And to compare with experiment, we also measured the FWHM and acquired the energy spectrum without scatter material in GATE simulation. As a result, without scatter material, the energy peak was almost same location, which are located nearby 364 keV, and other spectrum factors are same tendency in both cases. The FWHM was increased by increasing the distance of source to detector, and the error rate was approximately 3.8%. When we used the line source with scatter material, energy spectrum also indicated similar tendency in both cases. As you confirmed earlier, GATE simulation included real instrument and radioisotope characters for therapeutic radioisotope. Therefore this result that it was possible that various quantitative study for therapeutic radioisotope imaging in gamma camera/SPECT using GATE simulation.

The effects of physical factors in SPECT (물리적 요소가 SPECT 영상에 미치는 영향)

  • 손혜경;김희중;나상균;이희경
    • Progress in Medical Physics
    • /
    • v.7 no.1
    • /
    • pp.65-77
    • /
    • 1996
  • Using the 2-D and 3-D Hoffman brain phantom, 3-D Jaszczak phantom and Single Photon Emission Computed Tomography, the effects of data acquisition parameter, attenuation, noise, scatter and reconstruction algorithm on image quantitation as well as image quality were studied. For the data acquisition parameters, the images were acquired by changing the increment angle of rotation and the radius. The less increment angle of rotation resulted in superior image quality. Smaller radius from the center of rotation gave better image quality, since the resolution degraded as increasing the distance from detector to object increased. Using the flood data in Jaszczak phantom, the optimal attenuation coefficients were derived as 0.12cm$\^$-1/ for all collimators. Consequently, the all images were corrected for attenuation using the derived attenuation coefficients. It showed concave line profile without attenuation correction and flat line profile with attenuation correction in flood data obtained with jaszczak phantom. And the attenuation correction improved both image qulity and image quantitation. To study the effects of noise, the images were acquired for 1min, 2min, 5min, 10min, and 20min. The 20min image showed much better noise characteristics than 1min image indicating that increasing the counting time reduces the noise characteristics which follow the Poisson distribution. The images were also acquired using dual-energy windows, one for main photopeak and another one for scatter peak. The images were then compared with and without scatter correction. Scatter correction improved image quality so that the cold sphere and bar pattern in Jaszczak phantom were clearly visualized. Scatter correction was also applied to 3-D Hoffman brain phantom and resulted in better image quality. In conclusion, the SPECT images were significantly affected by the factors of data acquisition parameter, attenuation, noise, scatter, and reconstruction algorithm and these factors must be optimized or corrected to obtain the useful SPECT data in clinical applications.

  • PDF

An Experimental Comparative Study of Radiography, Ultrasonography and CT Imaging in the IV Catheter Fragment (정맥내 카테터 조각의 엑스선, 초음파 및 CT 영상의 실험적 비교 연구)

  • Kweon, Dae Cheol
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.185-191
    • /
    • 2016
  • The objective of this study was to detect the fragments generated during IV (intravenous) catheter injection of contrast medium and drug administration in a clinical setting and removal was performed by experimentally producing a phantom, and to compare the radiography, ultrasonography, and multi-detector computed tomography (MDCT) imaging and radiation dose. A 1 cm fragment of an 18 gage Teflon$^{(R)}$ IV catheter with saline was inserted into the IV control line. Radiography, CT, and ultrasonography were performed and radiography and CT dose were calculated. CT and ultrasonography showed an IV catheter fragment clinically and radiography showed no visible difference in the ability to provide a useful image of an IV catheter fragment modality (p >.05). Radiography of effective dose ($0.2139mSv{\cdot}Gy^{-1}{\cdot}cm^{-2}$) form DAP DAP ($0.93{\mu}Gy{\cdot}m^2 $), and dose length product (DLP) ($201mGy{\cdot}cm$) to effective dose was calculated as 0.483 mSv. IV catheter fragment were detected of radiography, ultrasonography and CT. These results can be obtained by menas of an excellent IV catheter fragment of detection capability CT. However, CT is followed by radiation exposure. IV catheter fragment confirming the position and information recommend an ultrasonography.

A Seamline Extraction Technique Considering the Characteristic of NDVI for High Resolution Satellite Image Mosaics (고해상도 위성영상 모자이크를 위한 NDVI 특성을 이용한 접합선 추출 기법)

  • Kim, Jiyoung;Chae, Taebyeong;Byun, Younggi
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.5
    • /
    • pp.395-408
    • /
    • 2015
  • High-resolution satellite image mosaics are becoming increasingly important in the field of remote sensing image analysis as an essential image processing to create a large image constructed from several smaller images. In this paper, we present an automatic seamline extraction technique and the procedure to generate a mosaic image by this technique. For more effective seamline extraction in the overlap region of adjacent images, an NDVI-based seamline extraction technique is developed, which takes advantage of the computational time and memory. The Normalized Difference Vegetation Index(NDVI) is an index of plant "greeness" or photosynthetic activity that is employed to extract the initial seamline. The NDVI can divide into manmade region and natural region. The cost image is obtained by the canny edge detector and the buffering technique is used to extract the ranging cost image. The seamline is extracted by applying the Dijkstra algorithm to a cost image generated through the labeling process of the extracted edge information. Histogram matching is also conducted to alleviate radiometric distortion between adjacent images acquired at different time. In the experimental results using the KOMPSAT-2/3 satellite imagery, it is confirmed that the proposed method greatly reduces the visual discontinuity caused by geometric difference of adjacent images and the computation time.

A STUDY ON THE MANDIBULAR MOMENTS ACCORDING TO ANTERO-POSTERIOR PLACEMENT OF PIVOT ON LOWER NATURAL DENTITION (자연치열에 설치한 pivot의 전후방 일치변화에 따른 하악의 moment에 관한 연구)

  • Lee Hyun-Shick;Park Nam-Soo;Choi Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.3
    • /
    • pp.394-410
    • /
    • 1993
  • This study was accomplished for appreciation of the mandibular moments according to antero- posterior movement of pivot placed on the lower natural dentition. For this study, 20 subjects(male, $21\sim30$ yrs., average age 24) in the category of normal occlusion were selected, and the intraoral Vitallium clutches were cast and fabricated for each subjects. A 2-dimension PSD(Position Sensitive Detector, Hamamatsu Photonics Co., Japan) was attached to maxillary clutch in a mode of three dimensional control and LED (Light Emit Diode, Hamamatsu Photonics Co., Japan) was set up on mandibular clutch. Both clutches were set into oral cavity of each subjects and adjusted. Then the subjects were allowed to intercuspated with maximal bite force while the pivoting ball in the mid-line moving from anterior toward posterior position. The displacement scales were recorded by CCD camera(Sony, CCD-TR-705) and VCR, The conclusions were as follows : 1. When the subject was allowed to bite the metal pivoting ball in the midline of lower dentition with maximal bite force voluntarily while moving from lower central incisor to canine, 1st premolar, End premolar, 1st molar and 2nd molar. The lever actions on the pivot were revealed in all subjects. The equilibrium of moment were revealed on the pivots of 1st premolar(14 subjects), End premolar(4 subjects), and canine(2 subjects) areas. 2. The changes of loading on the TMJ according to antero-posterior positional changes of metal pivoting ball were able to recognize as follow. Compression on the TMJ was increased when the pivot moves anteriorly from the equilibrium point, and tension on the TMJ was increased when posteriorly. 3. 13 subjects were recognized their habitual chewing sides(Rights, Left8), and 7 subjects were not. During maximal biting, mandible was displaced toward their habitual chewing sides on the metal pivoting ball in the frontal plane. 4. In cephalometric analysis, the average genial angle of 20 subjects was $116.75^{\circ}$ and the average mandibular body length was 79.77mm. The equilibrium points of mandibular moment were positioned more posteriorly in the subjects having larger Genial angle than in the smaller(p<0.05). Relationships among the angle between FH plane and occlusal plane, the angle between occlusal plane and mandibular plane , and mandibular body length were not significant(p>0.05).

  • PDF

Intertidal DEM Generation Using Waterline Extracted from Remotely Sensed Data (원격탐사 자료로부터 해안선 추출에 의한 조간대 DEM 생성)

  • 류주형;조원진;원중선;이인태;전승수
    • Korean Journal of Remote Sensing
    • /
    • v.16 no.3
    • /
    • pp.221-233
    • /
    • 2000
  • An intertidal topography is continuously changed due to morphodynamics processes. Detection and measurement of topographic change for a tidal flat is important to make an integrated coastal area management plan as well as to carry out sedimentologic study. The objective of this study is to generate intertidal DEM using leveling data and waterlines extracted from optical and microwave remotely sensed data in a relatively short period. Waterline is defined as the border line between exposed tidal flat and water body. The contour of the terrain height in tidal flat is equivalent to the waterline. One can utilize satellite images to generate intertidal DEM over large areas. Extraction of the waterline in a SAR image is a difficult task to perform partly because of the presence of speckle and partly because of similarity between the signal returned from the sea surface and that from the exposed tidal flat surface or land. Waterlines in SAR intensity and coherence map can effectively be extracted with MSP-RoA edge detector. From multiple images obtained over a range of tide elevation, it is possible to build up a set of heighted waterline within intertidal zone, and then a gridded DEM can be interpolated. We have tested the proposed method over the Gomso Bay, and succeeded in generating intertidal DEM with relatively high accuracy.

Bioequivalence Test of Fexofenadine Hydrochloride 120 mg Tablets (염산펙소페나딘 120밀리그람 정제의 생물학적동등성시험)

  • Cho, Hea-Young;Kang, Hyun-Ah;Kim, Se-Mi;Lee, Yong-Bok
    • YAKHAK HOEJI
    • /
    • v.52 no.3
    • /
    • pp.188-194
    • /
    • 2008
  • Fexofenadine, ($\pm$)-4-1-hydroxy-4-{4-(hydroxydiphenylmethyl)-1-piperidinyl}-butyl-a,a-dimethyl benzeneacetic acid, is a selective histamine $H_1$ receptor antagonist, and is clinically effective in the treatment of seasonal allergic rhinitis and chronic idiopathic urticaria as a first-line therapeutic agent. The purpose of the present study was to evaluate the bioequivalence of two fexofenadine hydrochloride tablets, $Allegra^{(R)}$ (Handok Pharmaceuticals Co., Ltd.) and Alecort (Samchundang Pharmaceutical Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The release of fexofenadine from the two fexofenadine hydrochloride formulations in vitro was tested using KP VIII Apparatus II method with various dissolution media. Twenty six healthy male subjects, 25.62$\pm$3.35 years in age and 70.05$\pm$11.71 kg in body weight, were divided into two groups and a randomized 2$\times$2 cross-over study was employed. After a single tablet containing 120 mg as fexofenadine hydrochloride was orally administered, blood samples were taken at predetermined time intervals and the concentrations of fexofenadine in serum were determined using HPLC with fluorescence detector. The dissolution profiles of two formulations were similar in all tested dissolution media. The harmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ were calculated, and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, $Allegra^{(R)}$, were -1.37, 5.22 and 16.50% for $AUC_t$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 (e.g., log 0.83$\sim$log 1.08 and log 0.81$\sim$log 1.03 for $AUC_t$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Alecort tablet was bioequivalent to $Allegra^{(R)}$ tablet.