• 제목/요약/키워드: 3-line detector

검색결과 137건 처리시간 0.036초

센서-회로 분리형 엑스선 DR 검출기를 위한 대면적 CMOS 영상센서 모사 연구 (Simulation Study of a Large Area CMOS Image Sensor for X-ray DR Detector with Separate ROICs)

  • 김명수;김형택;강동욱;유현준;조민식;이대희;배준형;김종열;김현덕;조규성
    • 방사선산업학회지
    • /
    • 제6권1호
    • /
    • pp.31-40
    • /
    • 2012
  • There are two methods to fabricate the readout electronic to a large-area CMOS image sensor (LACIS). One is to design and manufacture the sensor part and signal processing electronics in a single chip and the other is to integrate both parts with bump bonding or wire bonding after manufacturing both parts separately. The latter method has an advantage of the high yield because the optimized and specialized fabrication process can be chosen in designing and manufacturing each part. In this paper, LACIS chip, that is optimized design for the latter method of fabrication, is presented. The LACIS chip consists of a 3-TR pixel photodiode array, row driver (or called as a gate driver) circuit, and bonding pads to the external readout ICs. Among 4 types of the photodiode structure available in a standard CMOS process, $N_{photo}/P_{epi}$ type photodiode showed the highest quantum efficiency in the simulation study, though it requires one additional mask to control the doping concentration of $N_{photo}$ layer. The optimized channel widths and lengths of 3 pixel transistors are also determined by simulation. The select transistor is not significantly affected by channel length and width. But source follower transistor is strongly influenced by length and width. In row driver, to reduce signal time delay by high capacitance at output node, three stage inverter drivers are used. And channel width of the inverter driver increases gradually in each step. The sensor has very long metal wire that is about 170 mm. The repeater consisted of inverters is applied proper amount of pixel rows. It can help to reduce the long metal-line delay.

EfficientNetV2 및 YOLOv5를 사용한 금속 표면 결함 검출 및 분류 (Metal Surface Defect Detection and Classification using EfficientNetV2 and YOLOv5)

  • ;김강철
    • 한국전자통신학회논문지
    • /
    • 제17권4호
    • /
    • pp.577-586
    • /
    • 2022
  • 철강 표면 결함의 검출 및 분류는 철강 산업의 제품 품질 관리에 중요하다. 그러나 정확도가 낮고 속도가 느리기 때문에 기존 방식은 생산 라인에서 효과적으로 사용할 수 없다. 현재 널리 사용되는 알고리즘(딥러닝 기반)은 정확도 문제가 있으며 아직 개발의 여지가 있다. 본 논문에서는 이미지 분류를 위한 EfficientNetV2와 물체 검출기로 YOLOv5를 결합한 강철 표면 결함 검출 방법을 제안한다. 이 모델의 장점은 훈련 시간이 짧고 정확도가 높다는 것이다. 먼저 EfficientNetV2 모델에 입력되는 이미지는 결함 클래스를 분류하고 결함이 있을 확률을 예측한다. 결함이 있을 확률이 0.3보다 작으면 알고리즘은 결함이 없는 샘플로 인식한다. 그렇지 않으면 샘플이 YOLOv5에 추가로 입력되어 금속 표면의 결함 감지 프로세스를 수행한다. 실험에 따르면 제안된 모델은 NEU 데이터 세트에서 98.3%의 정확도로 우수한 성능을 보였고, 동시에 평균 훈련 속도는 다른 모델보다 단축된 것으로 나타났다.

PET/CT 검사에서 SharpIR 재구성 방법의 평가 (Evaluation of SharpIR Reconstruction Method in PET/CT)

  • 김정열;강천구;박훈희;임한상;이창호
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.12-16
    • /
    • 2012
  • 서론: 종래의 PET 영상 재구성에 있어서 FBP 등에 비해 3차원 반복 재구성 방법이 일반적으로 대체하고 있으며, 이것은 검출기 기하학적 특성과 완벽한 3차원 산란 평가 및 저잡음 randoms 평가 등의 더 진보된 재구성 알고리즘을 제공하고 활용되고 있다. 최근에 SharpIR알고리즘은 3차원 반복 재구성 알고리즘으로 PET 검출기 응답 정보를 통합하여 PET 영상의 잡음을 효과적으로 감소시켜 대조도를 향상 시키기 위한 것으로 알려지고 있다. 본 연구에서는 새로운 반복 시스템 모델인 SharpIR에 대한 성능 평가와 임상에서의 적용 가능성에 대해 알아보고자 한다. 실험재료 및 방법: 검출기 응답에 대한 분해능을 측정하기 위해 유리관(내경 1.1 mm, 두께 0.2 mm)에 $^{18}F$-FDG (250 MBq/mL)을 주입하여 축 방향 시야의 중심과 축 방향으로 5, 10, 15, 20 cm만큼 떨어진 지점에서 획득하였고 VUE point HD와 VUE point HD-SharpIR로 재구성하여 각각의 영상에서 반치폭을 구하였다. 또한 영상품질평가로 image quality phantom (NU2-2001)을 이용하여, 여러 개의 각각 다른 반지름을 가지는 원형구에 cold (직경 28, 37 mm)와 ho (직경 10, 13, 17, 22 mm)부분을 나누어 배경잡음을 주고 영상의 대조도를 평가하였다. 획득된 영상은 VUE point HD와 VUE point HD-SharpIR로 재구성을 하였다. 임상실험에서는 전신검사를 시행받은 환자 중 병소가 있는 환자 10명을 대상으로 VUE point HD와 VUE point HD-SharpIR로 재구성하였다. 이때 iterations을 1~10까지 변경하여 병소 부위와 간 부위에 관심영역을 설정하여 대조도를 평가하였다. 결과: VUE point HD로 재구성한 영상에서는 시야 중심으로부터 축방향 거리 증가와 함께 반치폭이 함께 증가하였지만 VUE point HD-SharpIR로 재구성한 영상에서는 거리가 증가하여도 일정한 반치폭을 나타냈다. 대조도는 팬텀 실험과 임상 실험에서 VUE point HD-SharpIR이 VUE point HD보다 대조도의 향상을 나타냈다. 결론: 검출기 시스템 응답에 대한 더 많은 정보를 포함시킴으로써 SharpIR 알고리즘은 VUE point HD에서 사용되는 기본 모델의 정확성을 향상시켰다. 또한 SharpIR은 VUE point HD보다 각각의 복셀에 관련된 더 많은 측정 위치를 가지는 시스템 모델이기 때문에 더욱 정교한 재구성 모델의 결과를 나타내기 위해 더 많은 반복이 걸린다. 결론적으로 SharpIR은 PET 영상에서 대조도를 향상시켰고 임상에서 적용할 수 있는 최적화된 재구성 조건을 알아보기 위해 종단적 연구를 통해 적용한다면 임상에서 유용하게 사용될 것이다.

  • PDF

실험적으로 제작한 Videodensitometer의 디지털 영상처리와 임상적 적용에 관한 연구 (DIGITAL IMAGE PROCESSING AND CLINICAL APPLICATION OF VIDEODENSITOMETER)

  • 박관수;이상래
    • 치과방사선
    • /
    • 제22권2호
    • /
    • pp.273-282
    • /
    • 1992
  • The purpose of this study was to propose the utility which was evaluated the digital image processing and clinical application of the videodensitomery. The experiments were performed with IBM-PC/16bit-AT compatible, video camera(CCdtr55, Sony Co., Japan), an color monitor(MultiSync 3D, NEC, Japan) providing the resolution of 512×480 and 64 levels of gray. Sylvia Image Capture Board for the ADC(analog to digital converter) was used, composed of digitized image from digital signal and the radiographic density was measured by 256 level of gray. The periapical radiograph(Ektaspeed EP-21, Kodak Co., U. S. A) which was radiographed dried human mandible by exposure condition of 70 kVp and 48 impulses, was used for primary X-ray detector. And them evaluated for digitzed image by low and high pass filtering, correlations between aluminum equivalent values and the thickness of aluminum step wedge, aluminum equivalent values of sound enamel, dentin, and alveolar bone, the range of diffuse density for gray level ranging from 0 to 255. The obtained results were as follows: 1. The edge between aluminum steps of digitized image were somewhat blurred by low pass filtering, but edge enhancement could be resulted by high pass filtering. Expecially, edge enhancement between distal root of lower left 2nd molar and alveolar lamina dura was observed. 2. The correlation between aluminum equivalent values and the thickness of aluminum step wedge was intimated, yielding the coefficient of correlation r=0.9997(p<0.00l), the regression line was described by Y=0.9699X+0.456, and coefficient of variation amounting to 1.5%. 3. The aluminum equivalent values of sound enamel, dentin, and alvolar bone were 15.41㎜, 12.48㎜, 10.35㎜, respectively. 4. The range of diffuse density for gray level ranging from 0 to 255 was wider enough than that of photodenstiometer to be within the range of 1-4.9.

  • PDF

Interpretation of the Chemical Transformation of Individual Asian Dust Particles Collected on the Western Coast of Korean Peninsula

  • Ma, Chang-Jin;Kim, Jong-Ho;Kim, Ki-Hyun
    • Asian Journal of Atmospheric Environment
    • /
    • 제6권1호
    • /
    • pp.14-22
    • /
    • 2012
  • This paper is focused on the comprehensive and detailed interpretation for the chemical transformation of individual Asian dust (hereafter called "AD") particles during long-range transport from source regions to receptor area. A multi-stage particle sampler was operated at a ground-based site in Taean, Korea directly exposed to the outflow of air masses from China during AD period in April 2003. Both quantitative and qualitative analyses for size-classified individual particles were carried out by a microbeam X-ray fluorescence (XRF) method and a microbeam Particle Induced X-ray Emission (micro-PIXE), respectively. Among major characteristic elements, the elemental masses of soil derived components, sulfur, and chloride varied as a function of particle size showing the monomodal maximum with a steeply increasing at 3.3-4.7 ${\mu}m$ particle size. Although the details on chemical composition of AD particle collected on a straight line from source area to our ground-based site are needed, a large amount of Cl coexisted in and/or on AD particles suggests that AD particles collected in the present study might be actively engaged in chemical transformation by sea-salt and other Cl containing pollutants emitted from the China's domestic sources. Through the statistical analyses it was possible to classify individual AD particles into six distinct groups. The internally mixed AD particles with Cl, which has various sources (e.g., sea-salt, coal combustion origin HCl, gaseous HCl derived from the adsorption of acids to sea-salt, and Cl containing man-made particles) were thoroughly fractionated by the elemental spectra drivened by the double detector system of micro-PIXE.

광학부품의 진공자외선특성 측정용 분광반사율계 제작 (Fabrication of reflectometer for vacuum ultraviolet spectral characteristic measurements of optical component)

  • 신동주;김현종;이인원
    • 한국광학회지
    • /
    • 제15권4호
    • /
    • pp.325-330
    • /
    • 2004
  • 진공자외선 파장영역에서 광학부품의 분광특성을 측정할 수 있는 중수소광원과 진공단색화장치, 시료챔버 및 광 검출기 구조의 진공자외선 분광반사율계를 제작하였다. 제작된 진공자외선 분광반사율계는 115nm∼330 nm의 분광영역에서 약 3.0${\times}$$10^{-4}$ Pa의 기압에서 작동하였다. 253.652 nm와 184.95 nm의 수은 선스펙트럼으로 진공단색화장치의 파장을 교정하여 그 분해능이 0.012 nm이고, 파장정확도가 $\pm$0.03 nm 임을 확인하였다. 중수소 광원을 이용하여 115 nm∼230 nm 파장대역의 진공자외선 영역에서 여러 가지 광학부품들에 이용되고 있는 재료(MgF$_2$, CaF$_2$, BaF$_2$, SiO$_2$, Sapphire)들의 분광투과율과 반사율을 측정하였다.

ICP-AES에서 에어로졸의 광산란에 의한 신호의 보정 (Signal compensation by the light scattering of sample aerosols in ICP-AES)

  • 연평흠;박용남
    • 분석과학
    • /
    • 제25권4호
    • /
    • pp.223-229
    • /
    • 2012
  • 시료 에어로졸에 의한 광산란 신호를 이용하여 ICP 분석신호를 보정하였다. 자체 제작한 초음파 분무기에서 발생되는 에어로졸에 대하여 다이오드나 He-Ne 레이저를 사용하여 광산란신호를 얻고 이를 기준으로 하여 분석신호의 변동에 대하여 보정하였다. 그 결과 Be, Pb 및 Co의 경우에 short-term (1분 이하)에 대한 신호의 RSD가 기존의 평균 3.4% 에서 0.9% RSD 이하로 큰 개선이 되었으며, 10분 정도의 long-term안정도는 14.9%에서 4.2%로 개선되었다. 이 방법은 펄스형태의 시료도입뿐 아니라 연속적 분무에서도 분무기의 안정성이 부족한 경우, 정밀도의 개선에 매우 유용하다. Long-term의 안정도 개선을 위해서는 광산란셀에서의 안정도 및 검출기의 잡음개선과 분무장치와 플라즈마 사이에서의 에어로졸 응축등에 의한 잡음의 개선이 필요한 것으로 보인다.

P-요소를 이용한 노랑초파리 난소에서의 세포특이적 유전자발현의 검출 (Probing Cell-Type Specific Gene Expression in the Ovarian Cells of Drosophila by P-Element Mediated Enhancer Detection)

  • 계명찬;조경상;김경진;이정주
    • 한국동물학회지
    • /
    • 제38권4호
    • /
    • pp.505-513
    • /
    • 1995
  • P-lement의 germ line transformation을 이용하여 초파리 난소에서의 세포특이적 유전자발현 양상을 조사하였다. 표지유전자인 lacZ의 발현양상은 생식세포, 체세포, 두 종류의 세포에서 모두 발현되는 경우로 대별되며, 생식세포에서 lacZ의 발현은 조세포 또는 조세포와 난자에서 동시적으로 발현되는 경우로 구분되었다. 난자주변 난포세포에서의 lacZ 발현은 난자형성 9-10기 난포의 경우 모든 세포에서 균일하게 발현되거나 일부 세포에서만 발현되는 양상으로 구분되었다. 일부의 난포세포에서 발현되는 경우 난자와 조세포 경계의 난포세포에서 발현되는 경우, 이들을 제외한 난포세포에서 발현되는 경우로 구분되었다. 난자주위의 난포세포에서 난자의 전후축을 따른 구배현상도 관찰되었다. 극세포 또는 경계세포에서 발현되는 3개의 독립라인을 분리하였다. 독립된 EDL의 난소에서 나타난 lacZ의 발현양상은 초파리 난자형성에 관여하는 유전자의 시간과 공간적인 발현을 반영하며 이들 유전자 분리의 기초를 제공할 것으로 사료된다.

  • PDF

간 이식편의 체적 예측을 위한 2점 이용 간 분리 (Liver Splitting Using 2 Points for Liver Graft Volumetry)

  • 서정주;박종원
    • 정보처리학회논문지B
    • /
    • 제19B권2호
    • /
    • pp.123-126
    • /
    • 2012
  • 본 논문은 생체간이식 전에 복부 MDCT(Multi-Detector Computed Tomography) 영상에서 간 이식편의 체적을 간단하고 정확하게 계산하기 위하여 좌간과 우간을 나누는 방법을 제안하였다. 본 알고리즘은 기증자와 수혜자의 안전을 보장하기 위하여 시스템과 의료진의 상호작업을 최소화 하여 의료진이 수술 전 이식편의 판단을 정확하게 처리할 수 있도록 하였다. 간이 추출된 영상에 좌간과 우간을 나눌 수 있는 2점(중간 정맥(MHV: Middle Hepatic Vein) 내부의 한 점과 좌우문맥(PV: Portal Vein) 분지부에서 한 점)을 선택한다. 선택된 중간정맥 내부의 점을 이용하여 중간정맥을 자동 인식한 후 중간정맥을 기준으로 절개선을 결정하여 문맥 분지부의 한 점을 연결하는 절개면을 형성한다. 좌간과 우간의 체적과 간 전체에 대한 좌우간의 비율을 계산한다. 계산된 체적의 정확성을 입증하기 위해 진단 방사선과 의사가 수동으로 처리하여 계산한 체적과 함께 수술 중 획득한 실측무게와 비교하였다. 실측무게와 수동으로 예측된 체적 사이의 오차에 대한 평균${\pm}$표준편차는 $162.38cm^3{\pm}124.39$이고, 실측무게와 2점을 이용하여 예측된 체적과의 오차에 대한 평균${\pm}$표준편차는 $107.69cm^3{\pm}97.24$이다. 실측무게와 수동으로 예측된 체적의 상관관계는 0.79이고, 실측무게와 2점을 이용하여 예측된 체적의 상관관계는 0.87이다. 그리고 2점을 선택한 후 좌우간을 분할하여 체적을 계산하는 시간을 측정하여 수술실에서 실시간으로 처리 가능한지의 여부를 확인하였다. 한 데이터세트($149.17pages{\pm}55.92$) 당 처리 시간의 평균${\pm}$표준편차는 $57.28sec{\pm}32.81$이다.

Analysis of calcium phosphate nanoclusters using the TOF-MEIS

  • Jung, Kang-Won;Park, Jimin;Yang, Ki Dong;Nam, Ki Tae;Moon, DaeWon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.228.2-228.2
    • /
    • 2015
  • We have developed a TOF-MEIS system using 70~100 keV He+. A TOF-MEIS system was designed and constructed to minimize the ion beam damage effect by utilizing a pulsed ion beam with a pulse width < 1 ns and a TOF delay-line-detector with an 120 mm diameter and a time resolution of 180 ps. The TOF-MEIS is an useful tool for interfacial analysis of the composition and structure of nano and bio systems. Our recent applications are reported. We investigated the effect with Polyaspartic Acid (pAsp) and Osteocalcin on the initial bone growth of calcium hydroxyl appatite on a carboxyl terminated surface. When pAsp is not added to the self-assembled monolayers of Ca 2mM with Phosphate 1.2 mM, the growth procedure of calcium hydroxyl appatite cannot be monitored due to its rapid growth. When pAsp is added to the SAMs, the initial grow stage of the Ca-P can be monitored so that the chemical composition and their nucleus size can be analyzed. Firstly discovered the existence of 1-nm-sized abnormal calcium-rich clusters (Ca/P ~ 3) comprised of three calcium ions and one phosphate ion. First-principles studies demonstrated that the clusters can be stabilized through the passivation of the non-collagenous-protein mimicking carboxyl-ligands, and it progressively changes their compositional ratio toward that of a bulk phase (Ca/P~1.67) with a concurrent increase in their size to ~2 nm. Moreover, we found that the stoichiometry of the clusters and their growth behavior can be directed by the surrounding proteins, such as osteocalcin.

  • PDF