• 제목/요약/키워드: 3-dimensional body scanner

검색결과 39건 처리시간 0.02초

3D Scanner를 이용한 인체계측방법 및 플레어스커트의 착의형태평가방법에 관한 연구 (A Study on the Feasibility of the 3D Scanning Method of Body Measurement and Wearing Evaluation)

  • 김혜경;석은영;서추연
    • 한국의류학회지
    • /
    • 제24권6호
    • /
    • pp.895-906
    • /
    • 2000
  • The study planned to testify the accuracy of the 3D scanner through analyzing the human body measurement method and the evaluation of flare skirt with 3D scanner. The results obtained from this study were as follows; First, the results of measurement for the dress form and human body by 3D scanner were more accurate than one or two dimensional measurement method. Second, from the results of the scan for the flare skirts as worn the human body, we could obtain very accurate horizontal section map. Third, in the clothing ergonomics viewpoint, the accuracy of the 3D scanner was very excellent and its utility was higher than that of the moir photography method. Therefore, the 3D scanner is very useful for the human body measurement and the wearing evaluation. In a nutshell, this study illustrates that we have to develop a program of automatic human body measurement system which will enhance the application of the 3D scanner.

  • PDF

인체측정용 3차원 스캐너 제작 (Development of Three Dimensional Scanner for Anthropometric Measurement)

  • 김민효;남윤자
    • 대한인간공학회지
    • /
    • 제20권3호
    • /
    • pp.77-88
    • /
    • 2001
  • A three dimensional body scanner for anthropomentric measurement has been developed. In this study, the slit laser beam projection method followed by digital image processing was used to provide accurate spatial data with the typical optical triangulation method to overcome the many difficulties in traditional in accurate and time-consuming tactic measurement method using rulers and gauges. Compared with other commercialized scanners. this system can obtain a relatively wide range of data at a much lower cost by the specially designed scanning process such as the simultaneous acquisition of vertical and horizontal body cross-section profiles.

  • PDF

노년 남성의 발 유형 분류 -Size Korea의 3차원 측정 데이터를 이용하여- (The Classification of Elderly Men's Feet - With the Three-dimensional Body Scanner Data of Size Korea -)

  • 석혜정;박지은
    • 복식
    • /
    • 제57권10호
    • /
    • pp.50-59
    • /
    • 2007
  • This study has been conducted to classify elderly men's feet with the three-dimensional body scanner data of Size Korea. It was intended to assist the manufacturing of the shoes that can appropriately perform the functions of feet, by providing the specific information about the shapes of elderly men's feet that are altered as a result of aging and shoe-wearing for a long time. The findings are as follows. 1. The investigations into the average and standard deviation of the measurements and index values for the elderly men's feet showed a large personal difference in the items of length and circumference. 2. The factors constituting the elderly men's feet were observed to be the size of foot width(Factor 1), the central angle of feet and the extension of toes(Factor 2), the size of ankle(Factor 3), the positions of lateral malleolus and pternion(Factor 4), and the position and size of medial malleolus(Factor 5). 3. The cluster analysis for the classification of elderly men's feet produced three types of them.

Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations

  • Bi, Chuang;Wang, Xingyu;Tian, Fangfang;Qu, Zhe;Zhao, Jiaming
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권4호
    • /
    • pp.236-249
    • /
    • 2022
  • PURPOSE. The present study compared the accuracy between digital and conventional implant impressions. MATERIALS AND METHODS. The experimental models were divided into six groups depending on the implant location and the scanning span. Digital impressions were captured using the intraoral optical scanner TRIOS (3Shape, Copenhagen, Denmark). Conventional impressions were taken with the monophase impression material based on addition-cured silicones, Honigum-Mono (DMG, Hamburg, Germany). A high-precision laboratory scanner D900 (3Shape, Copenhagen, Denmark) was used to obtain digital data of resin models and stone casts. Surface tessellation language (STL) datasets from scanner were imported into the analysis software Geomagic Qualify 14 (3D Systems, Rock Hill, SC, USA), and scan body deviations were determined through two-dimensional and three-dimensional analyses. Each scan body was measured five times. The Sidak t test was used to analyze the experimental data. RESULTS. Implant position and scanning distance affected the impression accuracy. For a unilateral arch implant and the mandible models with two implants, no significant difference was observed in the accuracy between the digital and conventional implant impressions on scan bodies; however, the corresponding differences for trans-arch implants and mandible with six implants were extremely significant (P<.001). CONCLUSION. For short-span scanning, the accuracy of digital and conventional implant impressions did not differ significantly. For long-span scanning, the precision of digital impressions was significantly inferior to that of the traditional impressions.

3차원 바디 스캐너를 이용한 남성 상반신 인체측정 -직접측정과의 비교- (Upper Body Measurement of Men using 3D Body Scanner -Compared to Anthropometry-)

  • 백경자;이정란
    • 한국의류학회지
    • /
    • 제32권1호
    • /
    • pp.24-34
    • /
    • 2008
  • Three dimensional body scan technology is being targeted for utilization in the apparel industry. The purpose of this study was to test reliability of the body scan data targeting from 20 to 24 year old men by comparing 3DM, 3D body-scanning semi-auto measurement extraction method, Scanworx, 3D body-scanning auto measurement extraction method, and traditional anthropometric method. We found significant differences in 9 out of 25 items in upper body measurements using 3DM and 16 out of 25 items using Scanworx. In the range of difference value of scan measures, it showed 1 item in the absolute value of more than 40mm between two measuring methods, 3 items in 20 up to 40mm, and less than 20mm in other items. Overall, in height items, the numerical value of traditional measure was higher and in girth, width, depth items, 3D scan measure was higher. We found out that reliability of 3D measurements taken from whole body scans was different according to scanners, scanning softwares, programs, and subjects.

Lower-body figure analysis of Chinese adult women

  • Cha, Sujoung
    • 복식문화연구
    • /
    • 제22권6호
    • /
    • pp.965-978
    • /
    • 2014
  • To determine the parameters to be considered when designing lower-body apparel, we analyzed the lower-body figures of adult women in their early 20s from Shanghai, China, using 3-dimensional whole body scanner. Thirty-nine lower-body-related measurements were used to analyze the figures of 210 Chinese women. Obesity and height of the lower body, length from waist to crotch, shape of abdomen, and leg bone length were analyzed. Factor analysis was performed and the results were classified into three clusters. The first cluster describes the obesity of the lower body, the second denotes small hip measurement, and the third describes slim and long legs. This is the first study to quantify figure analysis of the lower body of Chinese women using 3-dimensional body measurements. The findings of this study will provide concrete information regarding crotch width, crotch length, inseam, outseam, waist slope, etc., for designing trouser patterns for Chinese adult women.

의류 패턴 설계를 위한 삼차원 인체 체표면 스캔 데이터 활용에 관한 연구 (A Study on the Use of 3D Human Body Surface Shape Scan Data for Apparel Pattern Making)

  • 천종숙;서동애;이관석
    • 복식문화연구
    • /
    • 제10권6호
    • /
    • pp.709-717
    • /
    • 2002
  • In the apparel industry, the technology has been advanced rapidly. The use of 3D scanning systems fur the capture and measurement of human body is becoming common place. Three dimensional digital image can be used for design, inspection, reproduction of physical objects. The purpose of this study is to develop a method that drafts men's basic bodice pattern from scanned 3D body surface shape data. In order to pursue this purpose the researchers developed pattern drafting algorithm. The 3D scanner used in this study was Cyberware Whole Body Scanner WB-4. The bodice pattern drafting algorithm from 3D body surface shape data developed in this study is as follows. First, convert geometric 3D body surface data to 3D polygonal mesh data. Second, develop algorithm to lay out 3D polygonal patches onto a plane using Auto Lisp program. The polygon meshes are coplanar, and the individual mesh is continuously in contact with next one The bodice front surface shape data in polygonal patches form was lined up in bust and waist levels. The back bodice was drafted by lining up the polygonal mesh in scapula, chest, and waist levels. in the drafts, gaps between polygons were formed into the darts.

  • PDF

입체 형상 분석을 위한 3차원 계측시스템의 활용 -WBS와 RapidForm 2004를 중심으로- (Applications of Three-Dimensional Measurement System for Shape Analysis -Focused on WBS and RapidForm 2004-)

  • 이명희;정희경
    • 복식
    • /
    • 제55권5호
    • /
    • pp.55-64
    • /
    • 2005
  • The concern with three-dimensional measurement has been growing in recent years. And over the last few years, several studies have been made on three-dimensional measurement. Some of the studies using a three-dimensional measurement have focused on type of form of human body and evaluation of fitness. But there has been no study about applications of three-dimensional measurement system for shape analysis. So, the purpose of this study was to investigate about application of three-dimensional mea-surement system lot shape analysis. The instrument and tools for three-dimensional measurement was Whole Body 3D scanner(model name: Exyma-WBS2H). Analysis program used in experiment is Rapid Form 2004 PPI (INUS technology, Int, Korea). The following results were obtained; 1. The point data using three-dimensional measurement system built 3D model. 2. The three-dimensional data were used to analyze length and curvature of shape. 3. The shape using three-dimensional measurement system could be used in variety field.

3차원 바디 스캐너를 이용한 인체 치수 측정에 따른 노년 여성의 골프웨어 슬랙스 패턴 설계 (Designing Elderly Women's Golfwear Slacks Patterns with Dynamic Anthropometry Using a 3D Body Scanner)

  • 류신아;최종명;박길순
    • 한국의류학회지
    • /
    • 제36권4호
    • /
    • pp.456-471
    • /
    • 2012
  • This study creates a method with more scientific patterns for use in designing golfwear slacks patterns that better reflect the unique characteristics of body types for elderly women aged 60 or older. This study investigates (when designing human-engineering golfwear slacks for elderly women) the body types of elderly women and design slacks patterns suitable for golf actions in order to design golfwear slacks that show excellence in function and aesthetics as well as for exercise and everyday wear conditions. The study indicated that "total crotch length" was the design element for most considerations when manufacturing golf slacks. A survey on the production of golf slacks for elderly women aged 60 or older showed that the 6 firms participating have not produced an exclusive product for women 60 years of age or older and have only manufactured an enlarged size up to 85. All 6 firms participating replied "No" two the question "Do you produce in consideration of the body types of women over 60 years of age?" Polyester-polyurethane composites were the most widely used (among golf slacks materials) as spring-autumn applications.