• Title/Summary/Keyword: 3-axis

Search Result 4,807, Processing Time 0.03 seconds

RADIOLOGIC STUDY OF MANDIBULAR THIRD MOLAR OF KOREAN YOUTHS (한국인 청년의 하악지치에 관한 방사선학적 연구)

  • Ahn Hyung Kyu
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.12 no.1
    • /
    • pp.57-61
    • /
    • 1982
  • The author has made a study on the classification of the mandibular 3rd molars of Korean youths through dental radiography by means of Pell & Gregory's classification and on the prevalence of the dental caries of distal surface of the mandibular 2nd molar adjacent to the mandibular 3rd molars turned anteriorly. The results are as follow; 1. It was found that the largest case number was class I (272 cases, 52.9%) in the relation of the tooth to the ramus of the mandible and 2nd molar. 2. The mesio-angular position was the largest number (239 cases, 46.5%) in the relation of the long axis of the impacted mandibular 3rd molar to the long axis of the 2nd molar. 3. The mesio-angular position of class I was the largest number (140 cases, 27.2 %) in the relation of the tooth to the ramus of the mandible and 2nd molar and the long axis of the impacted mandibular 3rd molar to the long axis of the 2nd molar. 4. The average angle of the long axis of mandibular 3rd molar in mesioangular position or horizontal position to the occlusal plane was 143° 5. Mandibular 3rd molar with lesion such as dental caries or pericoronitis was 73 cases (14.2). 6. The caries incidence rate of the distal surface of the 2nd molar was about 3.1%.

  • PDF

Dosimetric Characteristics of Dual Photon Energy Using Independent Collimator Jaws (고에너지 선형가속기의 Independent Collimator를 이용한 비대칭 방사선 조사시 방사선량 결정에 미치는 요인에 관한 연구)

  • Kim Jeung-kee;Choi Young-Min;Lee Hyung-Sik;Hur Won-Joo
    • Radiation Oncology Journal
    • /
    • v.14 no.3
    • /
    • pp.237-244
    • /
    • 1996
  • Purpose : The accurate dosimetry of independent collimator equipped for 6MV and 15MV X-ray beam was investigated to search for the optimal correction factor. Materials and Methods : The field size factors, beam quality and dose distribution were measured by using 6MV, 15MV X-ray Field size factors were measured from $3{\times}3cm^2$ to $35{\times}35cm^2$ by using 0.6cc ion chamber (NE 2571) at Dmax. Beam qualities were measured at different field sizes, off-axis distances and depths. Isodose distributions at different off-axis distance using $10\times10cm^2$ field were also investigated and compared with symmetric field. Result: 1) Relative field size factors was different along lateral distance with maximum changes in $3.1\%$ for 6MV and $5\%$ for 15MV. But the field size factors of asymmetric fields were identical to the modified central-axis values in symmetric field, which corrected by off-axis ratio at Dmax. 2) The HVL and PDD was decreased by increasing off-axis distance. PDD was also decreased by increasing depth For field size more than $5{\times}cm^2$ and depth less than 15cm, PDD of asymmetric field differs from that of symmetric one ($0.5\~2\%$ for 6MV and $0.4\~1.4\%$ for 15MV). 3) The measured isodose curves demonstrate divergence effects and reduced doses adjacent to the edge close to the flattening filter center was also observed. Conclusion . When asymmetric collimator is used, calculation of MU must be corrected with off-axis and PDD with a caution of underdose in central axis.

  • PDF

Study on the Neutral Axis of Glulam and its Mechanical Properties (적층목질재(積層木質材)(Glulam)의 중립축(中立軸)과 강도적(强度的) 성질(性質)에 관한 연구(硏究))

  • Park, Heon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.42-52
    • /
    • 1990
  • In this study, thick 24mm glulams were composed of thick. 3, 4, 6, 8mm Larch laminas to study that the theoretical analysis and the experimental analysis regarding the location of neutral axis of the glulams were compared, and to study on the effect of location of neutral axis on mechanical properties of glulam. The variation of location of neutral axis after proportional limit(or elastical limit) was studied to offer basic data to make the better composition method of glulam. The result obtained can be summarized as follows: 1. The theoretical neutral axis was 0.547 in solid wood, and also 0.547 in glulams because glulams were composed of only Larch laminas. 2. In solid wood, the deviation of the theoretical and the experimental neutral axis location was 0.1%, But in glulams, the deviation from-12.2% to + 7.8% showed nonuniform pattern but no large deviation. Because laminas was only of Larch and so the mechanical properties of laminas were monotonous. 3. The neutral axis exerted no influance on the elasticity of glulam, which meaned that the maximum shear strength in the neutral axis showed no influance on elasticity limit. 4. The only minutely lower elasticities of glulam than that of solid wood were shown. This was because of influance of glue lines of glulam on the elasticlties. 5. The failure type of glulam was wholly simple tension failure and the horizontal shear failure near neutral axis was not taken place, which was that glue line was complete in bonding and the strength of the lamina was not various but uniform. 6. The ratio of tension strain($^{\varepsilon}t$) I compression strain($^{\varepsilon}c$) initially showed uniform level After the elasticity limit. the ratio was increased with the flow of time and so the tension strain was more increased than compression strain. So this proved tension lamination technique, which is that the mechanical properties of glulam could be improved, if the lamina of more superior strength would he added on the bottom side of the glulam.

  • PDF

OCCLUSAL ANALYSIS OF PATIENTS WITH TEMPOROMANDIBULAR DYSFUNCTION BY USE OF T-SCAN SYSTEM (T-Scan system을 이용한 측두하악 장애 환자의 교합 분석에 관한 연구)

  • Park Seon-Joo;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.3
    • /
    • pp.121-140
    • /
    • 1991
  • Fifteen dental college students of Chosun University without the abnormal occlusion, the history and symptom of temporomandibular dysfunction(TMD), and who had all permanent teeth except third molar and the fifteen moderate group and the fifteen severe group classified according to Helkimo's dysfunction index among patients on the basis of the symptom of TMD were selected. The occlusal contact, occlusal force and occlusal interference in eccentric movement was studied and analyzed using T-Scan system. The result were as follows : 1. The TLR centering around midsagittal axis was located at $1.42{\pm}0.82mm$ in control group, $3.36{\pm}1.45mm$ in severe group, and as TMD was heavier, occlusal contact was located at the farther point from midsagittal axis. 2. The PLR from the first contact to the fifth contact centering around midsagittal axis was located at $1.73{\pm}1.78mm$ in control group, $3.36{\pm}1.41mm$ in moderate group, and $5.39{\pm}4.32mm$ in severe group, and as TMD was heavier, occlusal contact was located at the farther point from midsgittal axis. 3. The TFB, PFB, RFB and LFB of occlusal contact centering around incisal axis had no significant difference statistically among control group, moderate group, and severe group, and it was located at first molar. 4.The LF and RF was smaller in TMD group than in control group. 5. The LR moment of occlusal force centering around midsagittal axis was located at $178.51{\pm}139.81N.mm$ in control group, $466.25{\pm}296.47N.mm$ in moderate group, and $749.18{\pm}588.18N.mm$ in severe group. And as TMD was heavier, it was located at the farther point from midsagittal axis. 6. The RL and LL of occlusal force centering around incisal axis had not-significance statistically among control group, moderate group, and severe group, and it was at the first molar. 7. The number of occlusal interference of the eccentric movement was increased in the patients of TMD.

  • PDF

Fast Axis Estimation from 3D Axially-Symmetric Object's Fragment (3차원 회전축 대칭 물체 조각의 축 추정 방법)

  • Li, Liang;Han, Dong-Jin;Hahn, Hern-Soo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.6
    • /
    • pp.748-754
    • /
    • 2010
  • To reduce the computational cost required for assembling vessel fragments using surface geometry, this paper proposes a fast axis estimation method. Using circular constraint of pottery and local planar patch assumption, it finds the axis of the symmetry. First, the circular constraint on each cylinder is used. A circular symmetric pot can be thought of unions of many cylinders with different radii. It selects one arbitrary point on the pot fragment surface and searches a path where a circumference exists on that point. The variance of curvature will be calculated along the path and the path with the minimum variance will be selected. The symmetric axis will pass through the center of that circle. Second, the planar patch assumption and profile curve is used. The surface of fragment is divided into small patches and each patch is assumed as plane. The surface normal of each patch will intersects the axis in 3D space since each planar patch faces the center of the pot. A histogram method and minimization of the profile curve error are utilized to find the probability distribution of the axis location. Experimental results demonstrate the improvement in speed and robustness of the algorithms.

Phase Stability of Laser-ablated $SmBa_2Cu_3O_{7-y}$ thin Films Investigated by Raman Scattering Spectroscopy

  • Kim, G.;Jeong, A.R.;Jo, W.;Park, D.Y.;Cheong, H.;Tsukada, A.;Hammond, R.H.;Beasley, M.R.
    • Progress in Superconductivity
    • /
    • v.11 no.2
    • /
    • pp.141-146
    • /
    • 2010
  • Phase stability diagram and boundary of a- and c-axis orientation of $SmBa_2Cu_3O_{7-y}$ (SmBCO) thin films grown by pulsed laser deposition (PLD) were reported with studies based on x-ray diffraction [1]. Four different samples are systematically analyzed: normal c-axis oriented orthorhombic $SmBa_2Cu_3O_{7-y}$, a-axis oriented $SmBa_2Cu_3O_{7-y}$, c-axis oriented orthorhombic $SmBa_2Cu_3O_{7-y}$ with $Sm_2BaCuO_5$ phase, and a mixture with c-axis oriented orthorhombic $SmBa_2Cu_3O_{7-y}$ and anomalously long-c tetragonal $SmBa_2Cu_3O_x$. Raman scattering spectroscopy equipped with polarization analysis elucidates the crystal orientation and the origin of the growth of the materials. It indicates that the technique can be used for quality control of conductor manufacturing processes as well as for enhancement of the materials properties.

Driving Information System of Bicycle by Using 3-Axis Acceleration Sensor (3축 가속도 센서를 응용한 자전거 주행정보 시스템)

  • Bae, Sung-Yul;Yi, Seung-Hwan
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.198-203
    • /
    • 2012
  • In this paper, the driving information system of the bicycle has been studied by using the 3-axis acceleration sensor. The sensor module composed of 3-axis acceleration sensor and MCU(Microcontroller Unit) was mounted onto the handle of bicycle and the experiments were conducted on the flatland, uphill and downhill of bicycle road. Three axis acceleration values were converted to the pitch and roll angles, then four major compensation methods have been applied to achieve meaningful data for driving information system. The experimental results of pitch angles showed 2.46, -1.26, 7.79 degrees in case of flatland, uphill, downhill, respectively. When the steering handle turned to the left direction, roll angles showed -29.35, -41.67, -36.98 degrees at each road condition. With the right-turn, roll angles presented 20.05, 33.75, 24.44 degrees in case of flatland, uphill, and downhill, respectively. The pitch angle has been increased more than 40 degrees at stop mode. By using the change of pitch and roll angles, we could obtain the driving information system of bicycle successfully.

Hybrid Technology using 3D Printing and 5-axis Machining for Development of Prototype of the Eccentric Drive System (편심구동장치 시제품 개발을 위한 3D프린팅-5축가공 복합기술)

  • Hwang, Jong-Dae;Yang, Jun-Seok;Yun, Sung-Hwan;Jung, Yoon-Gyo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.2
    • /
    • pp.38-45
    • /
    • 2016
  • Since a 5-axis machine tool has two rotary axes, it offers numerous advantages, such as flexible accessibility, longer tool life, better surface finish, and more accuracy. Moreover, it can conduct whole machining by rotating the rotary feed axes while setting the fixture at once without re-fixing in contrast to conventional 3-axis machining. However, it is difficult to produce complicated products that have a hollow shape. In contrast, 3D printing can produce an object with a complicated hollow shape easily and rapidly. However, because of layer thickness and shrinkage, its surface finish and dimensional accuracy are not adequate. Therefore, this study proposes hybrid technology by integrating the advantages of these two manufacturing processes. 3D printing was used as the additive manufacturing rapidly in the whole body, and 5-axis machining was used as the subtractive manufacturing accurately in the joining and driving places. The reliability of the proposed technology was verified through a comparison with conventional technology in the aspects of processing time, surface roughness. and dimensional accuracy.

High Sensitivity 3-axis Actuator for Slim Optical Disc Drive (슬림광디스크드라이브를 위한 고감도 3축구동 액추에어터)

  • Cheong, Young-Min;Lee, Jin-Won;Kim, Kwang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.1000-1003
    • /
    • 2002
  • For high density optical storage, there should be a high NA objective lens and a shorter wavelength laser diode. To secure the disc tilt margin related to the coma aberration, moreover, it's difficult to apply the tilt compensation mechanism into the portable PC. In this paper, we proposed the 3-axis asymmetry pickup actuator with high efficiency symmetric magnetic circuit, which consisted of the top cover type inner yoke for high magnetic flux density, the coil stack unit for the 3-axis independent operation and vertically polarized magnets. This newly suggested actuator features DVD-RAM recording, we achieved the high focus & track AC sensitivity and the greatly stabilized system.

  • PDF

Dynamic Analysis of a 3-Axis Ultra-Slim Actuator for Optical Disc Drives (광디스크 드라이브용 3축 초박형 액추에이터의 동특성 분석)

  • Kim Se-Won;Cho Tae-Min;Lee Ju-Hyung;Jin Kyoung-Bog;Rim Kyung-Hwa
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.4 s.235
    • /
    • pp.624-631
    • /
    • 2005
  • A note-book PC has become thinner in recent years, which requires the optical disc drives with small height and high memory capacity. Therefore the actuator of optical disc drives must be thinner and have disc tilt compensation function for high density memory. In this paper, the actuator with hybrid type is investigated for 3-axis ultra-slim actuator. A 3-axis ultra-slim actuator is designed by using the modal analysis of the actuator and the electromagnetic analysis of magnetic circuit to achieve dynamic characteristics. Also, magnetic force between tilt magnet and tilt yoke is investigated to and the influence on the DC sensitivity in the focus and track directions.