• Title/Summary/Keyword: 3-Phase motor

Search Result 790, Processing Time 0.027 seconds

Preliminary Study of a Turbopump Pyro Starter (터보펌프 파이로 시동기 기초연구)

  • Hong, Moon-Geun;Lee, Soo-Yong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.2
    • /
    • pp.74-80
    • /
    • 2008
  • The feasibility study into the development of turbine spinners, which start up the turbo-pump, has been carried out and the design requirements and parameters ranges have been presented. Turbine spinners use the solid propellant as such composite propellant based AN compound with high energy plasticizers, coolants, and phase stabilizer which relieves a sensible volume change due to the phase transformation of AN near room temperature. Propellants which have a homing rate of $0.2{\sim}0.3\;mm/s$ and pressure exponent ranged from 0.3 to 0.6, showed stable burn-out in the standard motor tests. Both the magnitude of ignition energy and its thermal transfer mechanism have been proved to have a tangible effect on the ignition of the pyre starter, and the results of this study showed that a flame temperature of 1400K would be quite adequate to get a stable ignition for the AN composite propellant.

The Control of 3-Phase Induction Motor by Hybrid Fuzzy-PID Controller : Auto-Tuning of Parameters using Genetic Algorithms (하이브리드 퍼지-PID 제어기에 의한 3상 유도 전동기의 속도제어 : 유전자 알고리즘에 의한 파라미터의 자동 동조)

  • Kwon, Yang-Won;Ahn, Tae-Chon;Kang, Hak-Su;Yoon, Yang-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.794-796
    • /
    • 1999
  • 본 논문에서는 3상 유도전동기의 속도를 제어하는데 기존 제어기의 문제점을 해결하고 최적화하기 위해서 유전자 알고리즘을 이용한 하이브리드 퍼지 -PID(HFPID) 제어기를 고안하고, 이에 대한 파라미터 설정 방법을 제안한다. 유도전동기의 제어는 지연시간이 길고, 비선형성이 강하며, 부하변동이 잦은 프로세스이기 때문에, 기존의 제어방식으로는 만족할만한 결과를 얻을 수 없다. 제안한 하이브리드 퍼지-PID 제어기는 PID 제어기의 장점인 과도기의 우수성과 퍼지 제어기의 장점인 정상기의 우수성을 퍼지 변수로 결합시켜 설계한다. 이 제어기에 유전자 알고리즘을 적용하여 최적의 퍼지 및 PID 파라미터를 설정하다. 그리고 이 제어기를 3상 유도전동기의 속도 제어에 응용한다. 또한 속도오차에 대한 룩업 표를 만들어 온라인 실시간 제어를 가능하게 한다. 이상의 과정을 3상 유도전동기에서 컴퓨터 시뮬레이션 하였다. 시뮬레이션 결과를 비교해 볼 때, 하이브리드 퍼지-PID 제어기는 기존의 제어기 보다 전동기의 속도 및 토크성분 전류 둥의 특성에서 우수한 성능을 보였다.

  • PDF

A Case Study on the High-quality DCM applied to the Foundation of Breakwater (방파제 기초에 적용된 고품질 DCM공법의 설계 및 시공 사례)

  • Kang, Yeoun-Ike;Shim, Min-Bo;Shim, Sung-Hyun;Kim, Ha-Young;Shim, Jae-Bum;Chun, Youn-Chul;Yoon, Jung-Ik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.815-826
    • /
    • 2009
  • The paper presents a case study addressing the design and construction aspects for DCM(Deep Cement Mixing) method employed as the foundation of a caisson type breakwater with heavy weight(10,700 ton/EA) and a high design wave height($H_{1/3}$=8.7m). The DCM was designed for the project(Ulsan New Port North Breakwater Phase 1) by optimizing the pattern of DCM columns with a combination of short and long columns (i.e., block type(upper 3m)+wall type(lower)) and considering overlapped section between columns as a critical section against shear force where the coefficient of effective width of treated column($\alpha$) was estimated with caution. It was shown that the value can be 0.9 under the condition with the overlapped width of 30cm. In addition to that, a field trial test was performed after improving conventional DCM equipment (e.g., mixing blades, cement paste supplying pipes, multi auger motor, etc.) to establish a standardized DCM construction cycle (withdrawal rate of mixing blades) which can provide the prescribed strength. The result of the field strength test for cored DCM specimens shows that the averaged strength is larger than the target strength and the distribution of the strength(with a defect rate of 7%) also satisfies with the quality control normal distribution curve which allows defect rate of 15.9%.

  • PDF

Backpack Palsy (배낭으로 인한 상완 신경총 마비)

  • Yoon, Oong-Yong;Lee, Kyu-Yong;Lee, Young Ju;Kim, Hee-Tae;Kim, Juhan;Kim, Myung-Ho
    • Annals of Clinical Neurophysiology
    • /
    • v.3 no.2
    • /
    • pp.143-146
    • /
    • 2001
  • Background : Backpack palsy was described in military personnel with shoulder girdle and proximal upper extremity symptoms, predominantly motor in nature related to the use of heavy backpack. Currently, backpack were used for sports, transporting school books and child carriers. We evaluated clinical and electrophysiological feature of backpack palsy. Methods : We included 11 patients with brachial plexopathy as a result of wearing a heavy backpack on long distance marches. All patients were done routine blood sampling, chest X-ray, C-spine X-ray and electrophysiological studies. Results : All patients were right handed person and were not as having a thoracic outlet syndrome. Sensory changes were main initial symptoms and major persistent symptoms were motor weakness. 9 patients(81.8%) were damaged the brachial plexus on non-dominant side, 1 patient was dominant and 1 patient was bilateral involvement. 10 patients(90.9%) were damaged to upper trunk of the brachial plexus by EMG findings. The prognosis was good, 10 patients(90.9%) were complete recovery during 8 weeks, 1 patient was developed reflex sympathetic dystrophy confirmed by 3-phase bone scan. Conclusions : Depression of the clavicle and costoclavicular space probably plays a certain role in pathogenic mechanism. The non-dominant side is more frequently affected, probably due to underdevelopment of the musculature in that side.

  • PDF

Effects of Differential Stability on Control of Multi-Joint Coordination in the Upper Extremity: A Torque Component Analysis

  • Ryu, Young Uk;Shin, Hwa Kyung
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Purpose: The purpose of the present current study was to examine control of upper limb multi-joint movements with differential coordination stability. To achieve the goals of the study, torque analyses were utilized to answer questions about how torque components were differed among various elbow-wrist coordination patterns. Methods: Eight self-reported right-handed college students (3 males and 5 females, mean age=20.6 yr) were volunteered. The task required participants to rhythmically coordinate the flexion-extension motions of their elbow and wrist with coordination relationship of $0^{\circ}$, $90^{\circ}$, and $180^{\circ}$relative phases between the two joints. Mean relative phase and phase stability (standard deviation of relative phase) were computed to for analysisze of overall coordination performance. To determine the figure out characteristics of torque components in elbow and wrist joints, impulse values of muscle torque (MT) and interactive torque (IT) and MT as a percentage of cycle duration (MT-PCD) were analyzed. Results: Torque results showed that the proximal elbow joint generated motions with mainly muscle efforts regardless of coordination patterns, while the distal wrist joint adjusted the coordination patterns by changing amount of MT. Impulse analyses showed that the least stable $90^{\circ}$ pattern was performed by utilizing a similar coordination strategy of the most stable $0^{\circ}$ pattern. Conclusion: The present current study suggests that the roles of distal and proximal joints differ in order to achieve various multi-joint coordination movements. This study provides information for use in gives an idea to development of rehabilitation or training programs for to persons with an impaired upper limb motor ability.

Three-dimensional kinematic motion analysis of door handling task in people with mild and moderate stroke

  • Lee, Jung Ah;Kim, Eun Joo;Hwang, Pil Woo;Park, Han Ram;Bae, Jae Hyuk;Kim, Jae Nam
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.3
    • /
    • pp.143-148
    • /
    • 2016
  • Objective: This study aimed to quantify one of the useful upper extremity movements to evaluate motor control abilities between the groups of people with mild and moderate arm impairments performing a door handling task. Design: Cross-sectional study. Methods: Twenty-one healthy participants and twenty-one persons with chronic stroke (9 mild stroke and 12 moderate stroke) were recruited for this study. Stroke participants were divided into 2 groups based on Fugle-Meyer Assessment scores of 58-65 (mild arm) and 38-57 (moderate arm). All they performed door handling task including the pronation and supination phases 3 times. We measured some movement factors which were reaction time, movement time, hand of peak velocity, hand of movement units to perform door handling task using the three-dimensional motion analysis. Results: The majority of kinematic variables showed significant differences among study groups (p<0.05). The reaction time, total and phase of movement time, hand of peak velocity, the number of movement units discriminated between healthy participants and persons with moderate upper limb stroke (p<0.05). In addition, reaction time, total and phase of movement time, the number of movement units discriminated between those with moderate and mild upper limbs of stroke patients (p<0.05). Conclusions: Three-dimensional kinematic motion analysis in this study was a useful tool for assessing the upper extremity function in different subgroups of people with stroke during the door handling task. These kinematic variables may help clinicians understand the arm movements in door handling task and consist of discriminative therapeutic interventions for stroke patients on upper extremity rehabilitation.

Development of Torque simulator for the performance analysis of the 10kW wind turbine system (10kW 풍력발전기의 동작특성 분석을 위한 토크 시뮬레이터 개발)

  • Kim, Se-Yoon;Kim, Sung-Ho;Lee, Jong-Hee;Moon, Jin-Young
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.6
    • /
    • pp.579-585
    • /
    • 2014
  • 10kW wind turbine is widely studied in the field of renewable energy for the merits of easy installation to the confined area such as hill, park and urban areas. The performance of various electrical devices such as converter and inverter in the wind turbine system should be systematically analyzed for various wind speeds. However, it is impossible to apply these devices directly to practical wind turbine system for the safety of wind turbine system. Therefore, it is required to develop torque simulator which can generate corresponding torque according to its wind speed. In this work, 10kW torque simulator which consists of three phase torque control inverter, 3 phase induction motor and PMSG(Permanent Magnet Synchronous Generator) is developed.

The Influence of Different Quantitative Knowledge of Results on Performance Error During Lumbar Proprioceptive Sensation Training (양적 결과지식의 종류가 요추의 고유수용성감각 훈련에 미치는 영향)

  • Cynn, Won-Suk;Choi, Houng-Sik;Kim, Tack-Hoon;Roh, Jung-Suk;Yi, Jin-Bock
    • Physical Therapy Korea
    • /
    • v.11 no.3
    • /
    • pp.11-18
    • /
    • 2004
  • This study is aimed at investigating the influence of different quantitative knowledge of results on the measurement error during lumbar proprioceptive sensation training. Twenty-eight healthy adult men participated and subjects were randomly assigned into four different feedback groups(100% relative frequency with an angle feedback, 50% relative frequency with an angle feedback, 100% relative frequency with a length feedback, 50% relative frequency with a length feedback). An electrogoniometer was used to determine performance error in an angle, and the Schober test with measurement tape was used to determine performance error in a length. Each subject was asked to maintain an upright position with both eyes closed and both upper limbs stabilized on their pelvis. Lumbar vertebrae flexion was maintained at $30^{\circ}$ for three seconds. Different verbal knowledge of results was provided in four groups. After lumbar flexion was performed, knowledge of results was offered immediately. The resting period between the sessions per block was five seconds. Training consisted of 6 blocks, 10 sessions per one block, with a resting period of one minute. A resting period of five minutes was provided between 3 blocks and 4 blocks. A retention test was performed between 10 minutes and 24 hours later following the training block without providing knowledge of results. To determine the training effects, a two-way analysis of variance and a one-way analysis of variance were used with SPSS Ver. 10.0. A level of significance was set at .05. A significant block effect was shown for the acquisition phase (p<.05), and a significant feedback effect was shown in the immediate retention phase (p>.05). There was a significant feedback effect in the delayed retention phase (p<.05), and a significant block effect in the first acquisition phase and the last retention phase (p<.05). In conclusion, it is determined that a 50% relative frequency with a length feedback is the most efficient feedback among different feedback types.

  • PDF

A Evaluation of Emergency Braking Performance for Electro Mechanical Brake using Interior Permanent Magnet Synchronous Motor (매입형 영구자석 동기전동기를 적용한 전기기계식 제동장치의 비상제동 성능평가)

  • Baek, Seung-Koo;Oh, Hyuck-Keun;Park, Joon-Hyuk;Kim, Seog-Won;Kim, Sang-soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.170-177
    • /
    • 2020
  • This study examined the clamping force control method and the braking performance test results of an electromechanical brake (EMB) using braking test equipment. Most of the studies related to EMBs have been carried out in the automotive field, dealing mainly with the static test results for various control methods. On the other hand, this study performed a dynamic performance evaluation. The three-phase interior permanent magnet synchronous motor (IPMSM) was applied to drive the actuator of the EMB, and the analysis was verified by JMAG(Ver. 18.0), which is finite element method (FEM) software. The current control, speed control, and position control were used for clamping force control of the EMB, and the maximum torque per ampere (MTPA) control was applied to the current controller for efficient control. The EMB's emergency braking deceleration performance was tested in the same way as conventional pneumatic brake systems when the wheel of a train rotates at 110 km/h, 230 km/h, and 300 km/h. The emergency braking time, with the wheel stopped completely at the maximum rotational speed, was approximately 73 seconds. The similarity of the braking time and deceleration pattern was verified through a comparison with the performance test results of the pneumatic brake system applied to the next generation high-speed railway vehicle (HEMU-430X).

THE DEVELOPMENT OF THE EM-$200^{TM}$ GAS-FILLED AFFF FIRE EXTINGUISHER FOR AUTOMATIC FIRE SUPPRESS10N SYSTEMS IN THE ENGINE COMPARTMENT OF AUTOMOBILES

  • Jung, Ki-Chang;Kim, Hong;Kang, Young-Goo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.598-605
    • /
    • 1997
  • In recent years, the number of vehicle fires, as well as the number of motor vehicles, has been increasing rapidly. Therefore, several types of automatic fire suppression systems for the engine compartment of automobiles have been developed to extinguish automobile fires, and most of these systems use halon 1301 as a fire extinguishing agent. Due to environmental concerns, the phase-out of halons has been announced, so now there is a need to replace halon 1301. For this, a 1,1,1,2,3,3,3-heptaflouropropane (HFC-227ea, FM-$200^{TM}$) gas-filled Aqueous Film- Forming foam (known as AFFF) extinguisher was devised even though air foam extinguishers could be used. This is because the air in the foam bubbles is a source of oxygen required for the combustion reaction. It can be surmised that it is possible to increase the fire extinguishing efficiency of AFFF by filling in foam bubbles with a gaseous extinguishing agent. The best choice is the FM-$200^{TM}$ gas-filled AFFF, Which has the maximum expansion ratio of 62:1. This makes it possible for the expanded foam to rapidly fill the engine compartment.

  • PDF