• Title/Summary/Keyword: 3-Phase Induction Motor

Search Result 336, Processing Time 0.022 seconds

Optimal Switching Pattern of Voltage Source Inverter (전압원인버어터의 최적스위칭패턴)

  • 정필선;정동화;이윤종
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.12 no.4
    • /
    • pp.386-398
    • /
    • 1987
  • This paper is proposed the Suboptimal PAWM(Pulse Amplitude Width Modulation) for minimize harmonic effects generated by switching operation of PWM Inverter. This strategy determine one switching pattern at a fixed point(fundamental) voltage u1=1.2) which THD(Total Harmonic Distortion) are minimized in the suboptimal PWM strategy, and controls only frequency in the inverter while voltage control is carried out by DC Chopper in the DC Link. This strategy is applied at VSD(Variable Speed Drive) of Three phase induction moter, and acoustic noise of motor, line to line voltage and current of inverter, current harmonic spectrum was estimated and also compared with other switching strategy. From the results, the validity of this strategy can be verified.

  • PDF

Calculation of Iron Loss under Rotational Magnetic Field Using Finite Element Method (회전 자계에 의한 철손의 유한요소 해석)

  • Lee, H.Y.;Park, G.S.;Hahn, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.147-149
    • /
    • 1994
  • In designing high efficiency electrical machines, calculation of iron loss is very important. And it is reported that in the induction motor and in the T-joint of 3 phase transformer, there occurred rotational magnetic field and much iron loss is generated owing to this field. In this paper, rotational power loss in the electrical machine under rotational magnetic field is discussed. Until now, loss analysis is based on the magnetic properties under alternating field. And with this one dimensional magnetic propertis, it is difficult to express iron loss under rotational field. In this paper, we used two dimensional magnetic property data for the numerical calculation of rotational power loss. We used finite element method for calculation and the analysis model is two dimensional magnetic property measurement system. We used permeability tensor instead of scalar permeability to present two dimensional magnetic properties. And in this case, we cannot uniquely define energy functional because of the asymmetry of the permeability tensor, so Galerkin method is used for finite element analysis.

  • PDF

Detection Method of Series Arc Signal (직렬아크신호지 검출방법)

  • Kil, Gyung-Suk;Ji, Hong-Keun;Park, Dae-Won;Kim, Il-Kwon;Rhyu, Keel-Soo;Song, Jae-Yong
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.5
    • /
    • pp.477-481
    • /
    • 2008
  • This paper dealt with a detection method of series arc existence which is a symptom of electric fires in low-voltage system. The proposed detection circuit consists of a high-pass filter with a low cut-off frequency of 3kHz to attenuate power frequency voltage by 80 dB and an active band-pass filter with a center frequency of 4kHz to detect only the series arc signals. The performance of the circuit was evaluated in a phase-controlled incandescent lamp as a non-linear load and an inverted-fed induction motor as a high frequency load by using the arc generator specified in UL1699. From the experimental results, it was confirmed that the proposed method solved the detection error, which is being the most problem, by discriminating the series arc signal even in non-linear and high frequency loads.

A Study on the Design of Single Phase Cycloconverter by Cosine Wave Crossing Control Method (코사인 점호방식에 의한 단상 싸이클로콘버터의 설계에 관한 연구)

  • 김시헌;안병원;노창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.5
    • /
    • pp.71-85
    • /
    • 1993
  • The Cycloconverter that the author is going to treat in this paper, has strong advantages over the D.C. Link Inverter in points of chattering torque problem and natural commutation. Thus, the Cycloconverter is expected to be well applied to large and low-speed machines which require better speed control at low frequency. But the control circuit of Cycloconverter has two weak points described as follows. 1) Because of its rather complicated control circuit, it is likely to be illoperating due to unexpected noise signals, thus the higher the accuracy and reliability of the circuit is required to be, the more the circuit may cost. 2) Because the load current is not purely sinusoidal, the Cycloconverter may possibly be destroyed in case of inaccurate convert switching resulted from the difficulties in detecting the load current-zero and the current direction at the moment. In this paper, the author first of all intends to design and build a modified VVVF-type Noncirculating Current Cycloconverter to which recently proposed control methods are applied for improving the circuit simplicity, the control performance, and the system reliability. And then, experiments for observing the output waveforms of the Cycloconverter which is controlled by Singled-Board Computer using 8086 16-bit microprocesser are carried out. Finally the author concludes the result of this study as follows. 1) By replacing the conventional analog control circuits such as Reference Wave Generator, Cosine Timing Wave Generator, and Comparator with softwares, a great circuit simplicity is achieved. 2) The output of the designed Cycloconverter changes its frequency very fast without showing discontinuity of its waveform, and this waveform characteristics enables the smooth speed control of Induction Motor. 3) The design control circuit of Cycloconverter can be applied to the systems of 12 or 24 pulses because of its short processing period.

  • PDF

A experimental Study on the Reinforced Coil Development for the Efficiency Improvement of a Single Phase Induction Motor (단상유도전동기의 효율 개선을 위한 강화코일 개발에 관한 실험적 연구)

  • Lee, Jong-Myong;Kim, Nam-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.78-84
    • /
    • 2010
  • The efficiency of system with a built-in coil is improved as (1) the total coil flux increases, (2) the space distribution of coil flux is closer to the sinusoidal wave and (3) the direction of coil flux flow becomes more inherent with the original direction at the same condition. Every turn RC(Reinforced Coil) is composed of OC having original region and two IC's strengthening bidirectionally the inner part flux in order to maintain the symmetry with origin. This way we will realize the inherent flux direction and the sinusoidal closeness as well. Accordingly RC type is obtained by connecting the pure OC's and RC's in just turns to be closer to sinusoidal flux wave. We proved experimentally the usefulness of reinforced coil to improve the efficiency of SPIM.

Hormonic Evaluation of An Imported IAT(Intra Airport Transit) System in Incheon International Airport (인천 국제공항청사 경전철 도입에 따른 고조파 영향 분석)

  • Kim, Jin-O;Song, Hak-Seon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.41-47
    • /
    • 2006
  • This paper presents harmonic evaluation of an IAT(Intra Airport Transit) system in Incheon International Airport. It will be used for electric vehicles with 80[kW] per car produced by Mitsubishi Heavy Industries Ltd, and which is constructed with SIV(Static Inverter), VVVF controller and two induction motor. The vehicles operated in the IAT system can be treated as rapidly changing DC loat and at a feeding substation, 3-phase electric power is transferred to DC 750[V] by rectifier. Since vehicles are changing continuously, the voltages for the load fluctuate in the IAT system, and moreover, the voltage fluctuation generates high-order harmonics. It results the difficulty in maintaining power quality in KEPCO systems' side. The power quality of the IAT system in Incheon International Airport is evaluated using PSCAD/EMTDC simulator in the paper. The THD(Total Harmonic Distortion) of voltages and TDD(Total Demand Distortion) of currents, indices are calculated for the IAT system using the results of PSCAD/EMTDC dynamic simulation.