• Title/Summary/Keyword: 3-Line buffer

Search Result 67, Processing Time 0.026 seconds

Efficient Buffer Allocation Policy for the Adaptive Block Replacement Scheme (적응력있는 블록 교체 기법을 위한 효율적인 버퍼 할당 정책)

  • Choi, Jong-Moo;Cho, Seong-Je;Noh, Sam-Hyuk;Min, Sang-Lyul;Cho, Yoo-Kun
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.27 no.3
    • /
    • pp.324-336
    • /
    • 2000
  • The paper proposes an efficient buffer management scheme to enhance performance of the disk I/O system. Without any user level information, the proposed scheme automatically detects the block reference patterns of applications by associating block attributes with forward distance of a block. Based on the detected patterns, the scheme applies an appropriate replacement policy to each application. We also present a new block allocation scheme to improve the performance of buffer cache when kernel needs to allocate a cache block due to a cache miss. The allocation scheme analyzes the cache hit ratio of each application based on block reference patterns and allocates a cache block to maximize cache hit ratios of system. These all procedures are performed on-line, as well as automatically at system level. We evaluate the scheme by trace-driven simulation. Experimental results show that our scheme leads to significant improvements in hit ratios of cache blocks compared to the traditional schemes and requires low overhead.

  • PDF

A Study on the Noise Reduction Method for Data Transmission of VLBI Data Processing System (VLBI 자료처리 시스템의 데이터 전송에서 잡음방지에 관한 연구)

  • Son, Do-Sun;Oh, Se-Jin;Yeom, Jae-Hwan;Roh, Duk-Gyoo;Jung, Jin-Seung;Oh, Chung-Sik
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.4
    • /
    • pp.333-340
    • /
    • 2011
  • KJJVC(Korea-Japan Joint VLBI Correlator) was installed at the KJCC(Korea-Japan Correlation Center) and has been operated by KASI(Korea Astronomy and Space Science Institute) from 2009. KJNC is able to correlate the VLBI observed data through KVN(Korean VLBI Network), VERA(VLBI Exploration of Radio Astrometry), and JVN(Japanese VLBI Network) and its joint network array. And it is used exclusively as computer in order to process the observed data for the scientific purpose KJJVC used the VSI(VLBI Standard Interface) as the VLBI international standard at the data input-output specification between each component. Especially, for correlating the observed data, the data is transmitted with 1024Mbps speed between Mark5B high-speed playback and RVDB(Raw VLBI Data Buffer). The EMI(Electromagnetic lnterference), which is occurred by data transmission with high-speed, cause the data loss and the loss occurrence is frequently often for long transmission cable. Finally it will be caused the data recognition error by decreasing the voltage level of digital data signal. In this paper, in order to minimize the data loss by measuring the EMI noise level in transmission of the VSI specification, the 3 methods such as 1) RC filtering method, 2) lmpedance matching using Microstrip line, and 3) Signal buffering method using Differential line driver, were proposed. To verify the effectiveness of each proposed method, the performance evaluation was conducted by implementing and simulations for each method. Each proposed method was effectively confirmed as the high-speed data transmission of the VSI specification.

In-line measurement of residence time distribution in twin-screw extruder using non-destructive ultrasound

  • Lee, Sang-Myung;Park, Jong-Cheol;Lee, Sang-Mook;Ahn, Young-Joon;Lee, Jae-Wook
    • Korea-Australia Rheology Journal
    • /
    • v.17 no.2
    • /
    • pp.87-95
    • /
    • 2005
  • In this study, we performed RTD measurement at the die exit of co-rotating twin-screw extruder using a non-destructive ultrasonic device. The ultrasonic device was attached at slit die and was composed of a steel buffer rod and 10 MHz longitudinal piezoelectric ultrasonic transducer. This in-line ultrasonic monitoring method is based on the ultrasonic response of $CaCO_3$ filled in polymer. The RTD is evaluated by variation of ultrasonic attenuation with time caused by change of the tracer concentration during extrusion. The ultrasonic tracer, pellet type of compounded $CaCO_3$ in polymer was used in this study. The effects of tracer concentration on RTD and flow patterns were studied. Evaluation for the residence functions at different screw speeds, feeding rates and screw configurations were also carried out.

Inhibition of Purine Nucleoside Phosphorylase (PNP) in Micrococcus luteus by Phenylglyoxal

  • Choi, Hye-Seon
    • Journal of Microbiology
    • /
    • v.34 no.3
    • /
    • pp.270-273
    • /
    • 1996
  • Micrococcus luteus purine nucleoside phosphorylase (PNP) has been purified and characterized. The physical and kinetic properties have been described previously. Chemical modification of the enzyme was attempted to gain insight on the active site. The enzyme was inactivated in a time-dependent manner by the arginine- specific modifying reagent phenylglyoxal. There was a linear relationship between the observed rate of inactivation and the phenylglyoxal concentration. At 30 $^{\circ}C$ the bimolecular rate constant for the modification was 0.015 $min^{-1}mM^{-1}$ in 50 mM $NaHCO_3$ buffer, pH 7.5. The plot of logk versus log phenylglyoxal concentration was a strainght line with a slope value of 0.9, indicating that modification of one arginine residue was needed to inactivate the enzyme. Preincubation with saturated solutions of substrates protected the enzyme from inhibition of phenylglyoxal, indicating that reactions with phenylglyoxal were directed at arginyl residues essential for the catalytic functioning of the enzyme.

  • PDF

Effects of Curcumin from Turmeric Supplementation in Freezing Buffer on Sperm Motilities and Reactive Oxygen Species Generation (동결보존액에 울금에서 추출한 Curcumin의 첨가가 정자의 운동성과 활성산소 생성에 미치는 영향)

  • Lee, Eun-Joo;Kim, Dae-Young
    • Journal of Embryo Transfer
    • /
    • v.32 no.3
    • /
    • pp.249-255
    • /
    • 2017
  • In this experiment, we determined the effect of curcumin supplementation in freezing buffer for miniature pig sperm cryopreservation. Each ejaculate was diluted with modified Modena B extender and mixed with lactose-egg yolk (LEY extender, 80% v/v lactose solution [310 mM], 20% v/v egg yolk, and $100{\mu}g/mL$ kanamycin sulfate) and LEY-glycerol Orvus ES Paste (LEYGO, 89.5% v/v LEY, 5% v/v glycerol, 1.5% v/v Orvus ES Paste), 100 mM trehalose supplemented with 0, 10, 50, 100, and $500{\mu}M$ of curcumin from turmeric, respectively. Following equilibration, the 0.5 mL French straws were frozen and plunged into $LN_2$ tank for 7 days at least. Sperm parameter and oxidative byproducts were determined by the computer assisted sperm motility analysis (CASA) and fluorescence-activated cell sorting (FACS) as compared with each groups. Supplementation of curcumin had no effect on sperm motility, progressive motility and curvilinear velocity. However, average-path velocity and straight-line velocity were significantly higher in $10{\mu}M$ curcumin group ($100.9{\pm}8.8{\mu}m/s$, $61.7{\pm}2.9{\mu}m/s$, respectively) than control group ($77.8{\pm}3.9{\mu}m/s$, $46.4{\pm}3.0{\mu}m/s$, respectively) (p < 0.05). In addition, the level of the O2 radical and H2O2 were comparatively decreased in curcumin groups by evaluation of ethidium and DCF fluorescence. According to the results, curcumin can improve sperm kinetic variables and alleviate ROS induced cryoinjury to pig sperm.

Study of the Surface Acoustic Wave Biosensors for Detection of the Immunoglobulin G (자가면역글로불린 G 측정을 위한 표면탄성파 바이오센서에 대한 연구)

  • Kim, Gi-Beum;Cheong, Woo-Suk;Park, Young-Ran;Kim, Shang-Jin;Kim, Seong-Jong;Kang, Hyung-Sub;Kim, Jin-Shang;Hong, Chul-Un
    • Korean Chemical Engineering Research
    • /
    • v.49 no.2
    • /
    • pp.224-229
    • /
    • 2011
  • In this study, we have developed shear horizontal(SH) surface acoustic wave(SAW) sensors for the detection of immunoglobulin G(IgG) on the gold coated delay line of SH-SAW devices. As the result of the experiment, we could uniformly immobilize anti-MIgG(mouse IgG) conjugate on the surface of gold. When displaying results of immobilization on the surface of gold using G-anti MIgG conjugate and blocking buffer in frequency shift, G-anti MIgG conjugate showed frequency shift of 75.1 kHz in the initial frequency, and blocking buffer showed frequency shift of 215.7 kHz. When various concentrations of MIgG was added in 100MHz type sensor, the sensor showed 46.3, 127.45, 161.21 and 262.39 kHz frequency shift at 25, 50, 75 and 100 ${\mu}g$ MIgG concentration, respectively.

Spectrophotometric Determination of Ultra trace Tri & Hexavalent Chromium by Using on-line Flow Injection Analysis with Dual Pre-concentration Column

  • Jung, Sung-Woon;Lim, Hyun-Woo;Kang, Chul-Ho;Choi, Yong-Wook
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.9
    • /
    • pp.3437-3442
    • /
    • 2011
  • An on-line flow injection analysis with dual pre-concentration method was developed to determine the ultra trace tri and hexavalent chromium in water. In this system, the cation and anion pre-concentration columns were combined with a 10-port injection valve and then used to separate and concentrate Cr (III) and Cr (VI) selectively. The two species of concentrated chromium were sequentially eluted and determined by using HCl-KCl buffer of pH 1.8 as an eluent. Cr (III) was oxidized by hydrogen peroxide to Cr (VI). It was detected spectrophotometrically at 548 nm by complexation with DPC (diphenylcarbazide). Several factors such as concentration of $H_2O_2$, DPC and coil length in reaction condition were optimized. The linear range for Cr (III) and Cr (VI) was 0.1-50 ${\mu}g$/L. The limit of detections ($3{\sigma}$) of Cr (III) and Cr (VI) were 52 ng/L and 44 ng/L under the optimized FIA system, and their recoveries 98% and 103%, respectively. This method was applied to analyze contamination level of chromium species in tap water, groundwater and bottled water.

Rendering States Changing Costs Reducing Technique for Real-time 3D Graphics (실시간 3D 그래픽을 위한 렌더링 상태 변경 비용 감소 기법)

  • Kim, Seok-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.1843-1849
    • /
    • 2009
  • In real-time 3D Graphics, pipeline optimization is one of techniques enhancing rendering performance. Pipeline optimization is kind of buffer reordering problem, but it is NP-hard. Therefore techniques that is approximating optimal solution and suitable for real-time 3D graphics are needed. This paper analyze pattern of rendering states changing costs for real-time 3D graphics, and based on this, the algorithm that brings rendering states into line by changing costs is proposed. The proposed technique shows good performance enhancement when costs of some rendering states are much higher than others. Proposed technique shows 2.5 to 4 times better performance than non-ordering algorithm and becomes more faster when rendering costs of a state gets higher.

A Study on the Three Dimensional Road Design Technique Based on GIS Technique (GIS를 이용한 3차원도로시뮬레이션에 관한 연구)

  • Gwon, Hyeok Chun;Lee, Byeong Geol
    • Journal of Environmental Science International
    • /
    • v.13 no.6
    • /
    • pp.489-495
    • /
    • 2004
  • The purpose of this research is to apply GIS(Geographic Information System) for the road simulation and find some benefits analysis for the design processes. The northern Jeju island was selected as a case study. The 1/5,000 digital map and GIS technique were used for optimum road design of the island based on Arc View software. Using this software we can get an overlay map by combination of hill shade map, slope map, aspect map, and building buffer map. Based on the overlay map, we designed the optimum road line and performed three dimensional simulation. From the results, we found that the developed three dimensional road simulation technique using GIS technique that was very useful tool to estimate the reasonable road design before the real road construction works.

The Study on the Thyroglobulin in Thyroid Diseases (갑상선질환(甲狀腺疾患)의 Thyroglobulin에 관(關)한 연구(硏究)(예보(豫報)))

  • Kim, Suk-Keun;Lim, Soo-Duk;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.4 no.1
    • /
    • pp.43-49
    • /
    • 1970
  • In recent years with development of immuno-electrophoresis, more acurate analysis of the serum protein became possible. However, there is few reports in the literature which investigated the changes of the immunoglobulin compared with electrophoretically fractioned serum thyroglobulin in the patients with various thyroid diseases. The purpose of this report is to investigate the changes of thyroglobulin in various thyroid diseases by the method of immuno-electrophoresis and to compare the results with.serum protein fractionated by the method of agar-gel micro-electrophoresis. Materials and Methods: Sera from 9 patients with diffuse toxic goiter, 2 nodular nontoxic goiter, 2 thyroiditis, 3 hypothy, roidism, 1 thyroid cancer, 7 cystic degeneration of the thyroid gland, and 10 normal subject were taken. All cases were confirmed by various laboratory thyroid function tests and thyroid needle biopsy. Immuno-electrophoretic analysis of the serum were performed by Scheidegger's modified micro-immuno-electrophoretic method. The antiserum was obtained from the Travenol Laboratories International, Hyland Products Division and was rabbit anti-human thyroglobulin. Microscope slide agar-gel electrophoresis for serum protein fractionation was performed at $4^{\circ}C$ using veronal buffer, pH 8.6 and ionic strength 0.05, with 54 volts and 2.8 mA for 60 minutes. The fractionated slide was stained with 0.1% thiazine red. The results were as follows: 1) Increase of immune-globulin macroglobulin (IgM), alphaglobulin, and immune-globulin A (IgA) by 95.8%, 100%, 29.2% respectively was found in the serum from various thyroid diseases. 2) Thyroglobulin fraction was found to be increased in 50%, no change in 41.7%, and no line in 8.3% with all of the various goiter patients. On the other hand, 10 normal control group showed only 2 cases of increase, 5 cases of no change and 3 cases of no line.

  • PDF