• Title/Summary/Keyword: 3-Dimensional Measurement

Search Result 1,256, Processing Time 0.031 seconds

Does cone-beam CT alter treatment plans? Comparison of preoperative implant planning using panoramic versus cone-beam CT images

  • Guerrero, Maria Eugenia;Noriega, Jorge;Castro, Carmen;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.121-128
    • /
    • 2014
  • Purpose: The present study was performed to compare the planning of implant placement based on panoramic radiography (PAN) and cone-beam computed tomography (CBCT) images, and to study the impact of the image dataset on the treatment planning. Materials and Methods: One hundred five partially edentulous patients (77 males, 28 females, mean age: 46 years, range: 26-67 years) seeking oral implant rehabilitation were referred for presurgical imaging. Imaging consisted of PAN and CBCT imaging. Four observers planned implant treatment based on the two-dimensional (2D) image data-sets and at least one month later on the three-dimensional (3D) image dataset. Apart from presurgical diagnostic and dimensional measurement tasks, the observers needed to indicate the surgical confidence levels and assess the image quality in relation to the presurgical needs. Results: All observers confirmed that both imaging modalities (PAN and CBCT) gave similar values when planning implant diameter. Also, the results showed no differences between both imaging modalities for the length of implants with an anterior location. However, significant differences were found in the length of implants with a posterior location. For implant dimensions, longer lengths of the implants were planned with PAN, as confirmed by two observers. CBCT provided images with improved scores for subjective image quality and surgical confidence levels. Conclusion: Within the limitations of this study, there was a trend toward PAN-based preoperative planning of implant placement leading towards the use of longer implants within the posterior jaw bone.

Mdlti-View Video Generation from 2 Dimensional Video (2차원 동영상으로부터 다시점 동영상 생성 기법)

  • Baek, Yun-Ki;Choi, Mi-Nam;Park, Se-Whan;Yoo, Ji-Sang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.1C
    • /
    • pp.53-61
    • /
    • 2008
  • In this paper, we propose an algorithm for generation of multi-view video from conventional 2 dimensional video. Color and motion information of an object are used for segmentation and from the segmented objects, multi-view video is generated. Especially, color information is used to extract the boundary of an object that is barely extracted by using motion information. To classify the homogeneous regions with color, luminance and chrominance components are used. A pixel-based motion estimation with a measurement window is also performed to obtain motion information. Then, we combine the results from motion estimation and color segmentation and consequently we obtain a depth information by assigning motion intensity value to each segmented region. Finally, we generate multi-view video by applying rotation transformation method to 2 dimensional input images and the obtained depth information in each object. The experimental results show that the proposed algorithm outperforms comparing with conventional conversion methods.

Quantitative Analysis for Surface Recession of Ablative Materials Using High-speed Camera and 3D Profilometer (초고속 카메라와 삼차원 표면 측정기를 이용한 삭마 재료의 정량적 표면 침식 분석)

  • Choi, Hwa Yeong;Roh, Kyung Uk;Cheon, Jae Hee;Shin, Eui Sup
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.9
    • /
    • pp.735-741
    • /
    • 2018
  • In this paper, the surface recession of ablative materials was quantitatively analyzed using a high-speed camera and a three-dimensional profilometer. The ablation tests of the graphite and carbon/phenolic composite samples were performed using a 0.4 MW arc-heated wind tunnel for simulating the atmospheric re-entry environment. The real-time images during the ablation test were captured by the high-speed camera, and analyzed to calculate the surface recession and recession rate. Also, the surface data of samples were obtained using a three-dimensional profilometer, and the surface recession was precisely calculated from the difference of height between the surface data before and after the test. It is effective to complement the two measurement results in the comprehensive analysis of surface recession phenomena.

3-D Solder Paste Inspection Based on B-spline Surface Approximation (B-spline 표면 근사화 기반의 3차원 솔더 페이스트 검사)

  • Lee, Joon-Jae;Lee, Byoung-Gook;Yoo, Jae-Chil
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.10 no.1
    • /
    • pp.31-45
    • /
    • 2006
  • Recently advanced device and sophisticated manufacture process by high-density, high-integration require critical inspection criteria in SMT(surface mounting technologies). Especially for solder paste which come out over 60% of inferior goods of all product, 3-dimensional inspection replaces 2-D inspection as a effectiveness substitute of this trend. Therefore this paper proposes a fast 3-D inspection system and measurement algorithm automatically inspecting 3-D solder paste of PCB in SMT assembly line. The proposed method generates 3-D surface of data using B-spline algorithm and then extracts to inspect the pad.

  • PDF

A Study on the Use of 3D Human Body Surface Shape Scan Data for Apparel Pattern Making (의류 패턴 설계를 위한 삼차원 인체 체표면 스캔 데이터 활용에 관한 연구)

  • 천종숙;서동애;이관석
    • The Research Journal of the Costume Culture
    • /
    • v.10 no.6
    • /
    • pp.709-717
    • /
    • 2002
  • In the apparel industry, the technology has been advanced rapidly. The use of 3D scanning systems fur the capture and measurement of human body is becoming common place. Three dimensional digital image can be used for design, inspection, reproduction of physical objects. The purpose of this study is to develop a method that drafts men's basic bodice pattern from scanned 3D body surface shape data. In order to pursue this purpose the researchers developed pattern drafting algorithm. The 3D scanner used in this study was Cyberware Whole Body Scanner WB-4. The bodice pattern drafting algorithm from 3D body surface shape data developed in this study is as follows. First, convert geometric 3D body surface data to 3D polygonal mesh data. Second, develop algorithm to lay out 3D polygonal patches onto a plane using Auto Lisp program. The polygon meshes are coplanar, and the individual mesh is continuously in contact with next one The bodice front surface shape data in polygonal patches form was lined up in bust and waist levels. The back bodice was drafted by lining up the polygonal mesh in scapula, chest, and waist levels. in the drafts, gaps between polygons were formed into the darts.

  • PDF

Evaluation of the repeatability and matching accuracy between two identical intraoral spectrophotometers: an in vivo and in vitro study

  • Kim, Hee-Kyung
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.252-258
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate the repeatability and matching accuracy between two identical intraoral spectrophotometers. MATERIALS AND METHODS. The maxillary right central incisor, canine, and mandibular left central incisor of each of 30 patients were measured using 2 identical intraoral spectrophotometers with different serial numbers (EasyShade V). The color of each shade tab from 3 shade guides (VITA 3D-Master) was also determined with both devices. All measurements were performed by a single operator. Statistical analyses were performed to verify the repeatability, accuracy, and the differences between the devices with paired t-tests, one-way ANOVA, and intra-class correlation coefficients (ICCs) (${\alpha}=.05$). RESULTS. A high level of measurement repeatability (ICC>0.90) among $L^*$, $a^*$, and $b^*$ color components was observed within and between devices (P<.001). Intra-device matching agreement rates were 80.00% and 81.11%, respectively, while inter-device matching agreement rate was 51.85%. ANOVA revealed no significant different color values within each device, while paired t-test provided significant different color values between both devices. The CIEDE2000 color differences between both devices were $2.28{\pm}1.61$ ${\Delta}E_{00}$ for in-vivo readings. Regarding the clinical matching accuracy of both devices, ${\Delta}E_{00}$ values between teeth and matching shade tabs were $3.05{\pm}1.19$ and $2.86{\pm}1.02$, respectively. CONCLUSION. Although two EasyShade V devices with different serial numbers show high repeatability of CIE $L^*$, $a^*$, and $b^*$ measurements, they could provide different color values and shade for the same tooth.

Correlation Analysis of Flow Characteristics Downstream of a Double Bent Pipe and Mounting Positions of Ultrasonic Flowmeter (곡관하류의 유동특성과 초음파유량계 설치위치의 상관관계 분석)

  • Lee, Dong Keun;Cho, Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.1037-1046
    • /
    • 2013
  • In this study, the establishment of the criteria for accurate measurement is investigated via a statistical analysis of experimental results. The magnitude of influence on measurement errors is severely affected by the number of paths, mounting angle of sensor, straight pipe length in sequence, and Reynolds number. Three-dimensional numerical analysis has been conducted to understand the flow patterns downstream of a double bent pipe. Numerical analysis shows that the results well agreed with the experimental ones in case of a sensor mounting angle of $0^{\circ}$ and L/D = 3, 5 of $45^{\circ}$, $135^{\circ}$ in a single path. As a result, when the Reynolds number is 700,000-1,400,000, the sensor error of a single-path ultrasonic flowmeter is reduced with the mounting condition of L/D = 3, $45^{\circ}$.

Impedance Spectroscopy Analysis on the LaAlO3/SrxCa1-xTiO3/SrTiO3 Hetero-Oxide Interface System

  • Park, Da-Hee;Kwon, Kyoung-Woo;Park, Chan-Rok;Choi, Yoo-Jin;Bae, Seung-Muk;Baek, Senug-Hyub;Kim, Jin-Sang;Hwang, Jin-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.188.2-188.2
    • /
    • 2015
  • The presence of the conduction interface in epitaxial $LaAlO_3/SrTiO_3$ thin films has opened up challenging applications which can be expanded to next-generation nano-electronics. The metallic conduction path is associated with two adjacent insulating materials. Such device structure is applicable to frequency-dependent impedance spectroscopy. Impedance spectroscopy allows for simultaneous measurement of resistivity and dielectric constants, systematic identification of the underlying electrical origins, and the estimation of the electrical homogeneity in the corresponding electrical origins. Such unique capability is combined with the intentional control on the interface composition composed of $SrTiO_3$ and $CaTiO_3$, which can be denoted by $SrxCa1-_xTiO_3$. The underlying $Sr_xCa1-_xTiO_3$ interface was deposited using pulsed-laser deposition, followed by the epitaxial $LaAlO_3$ thin films. The platinum electrodes were constructed using metal shadow masks, in order to accommodate 2-point electrode configuration. Impedance spectroscopy was performed as the function of the relative ratio of Sr to Ca. The respective impedance spectra were analyzed in terms of the equivalent circuit models. Furthermore, the impedance spectra were monitored as a function of temperature. The ac-based characterization in the 2-dimensional conduction path supplements the dc-based electrical analysis. The artificial manipulation of the interface composition will be discussed towards the electrical application of 2-dimensional materials to the semiconductor devices in replacement for the current Si-based devices.

  • PDF

3-Dimensional Dosimetry of Small Field Photon Beam (광자선의 소조사면에서의 3차원적 선량 측정)

  • Jang, Ji-Sun;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.54-61
    • /
    • 2012
  • A polymer gel dosimeter was fabricated. A 3-dimensional dosimetry experiment was performed in the small field of the photon of the cyberknife. The dosimeter was installed in a head and neck phantom. It was manufactured from the acrylic and it was used in dosimetry. By using the head and neck CT protocol of the CyberKnife system, CT images of the head and neck phantom were obtained and delivered to the treatment planning system. The irradiation to the dosimeter in the treatment planning was performed, and then, the image was obtained by using 3.0T magnetic resonance imaging (MRI) after 24 hours. The dose distribution of the phantom was analyzed by using MATLAB. The results of this measurement were compared to the results of calculation in the treatment planning. In the isodose curve on the axial direction, the dose distribution coincided with the high dose area, 0.76mm difference on 80%, rather than the low dose area, 1.29 mm difference on 40%. In this research, the fact that the polymer gel dosimeter and MRI can be applied for analyzing a small field in a 3 dimensional dosimetry was confirmed. Moreover, the feasibility of using these for the therapeutic radiation quality control was also confirmed.

New Breast Measurement Technique and Bra Sizing System Based on 3D Body Scan Data

  • Oh, Seolyoung;Chun, Jongsuk
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.4
    • /
    • pp.299-311
    • /
    • 2014
  • Objective: The aim of this study was to develop a method for measuring breast size from three-dimensional (3D) body scan image data. Background: Previous bra studies established reference points by directly contacting the subject's naked skin to determine the boundary of the breast. But some subjects were uncomfortable with these types of measurements. This study examined noncontact methods of extracting breast reference points from 3D body scan data that were collected while subjects were wearing standardized soft bras. Method: 3D body scan data of 32 Korean women were analyzed. The subjects were selected from the Size Korea 2010 study. The breast landmarks were identified by graphic analyses of slicing contour lines on 3D body scan data. Results: Three methods determining bra cup size were compared. The M1 and M2 methods determined cup size by calculating the difference between bust girth and under-bust girth. The M3 method determined bra cup size by measuring breast arc length. Conclusion: The researchers proposed an anthropometric bra cup sizing system with the breast arc length (M3 method). It was measured from the geometrically defined landmarks on the 3D body scan slicing contour lines. The new bra cup size was highly correlated with breast depth. Application: The noncontact measuring method used in this study can be applied to the ergonomic studies measuring sensitive body parts.