In this study, the establishment of the criteria for accurate measurement is investigated via a statistical analysis of experimental results. The magnitude of influence on measurement errors is severely affected by the number of paths, mounting angle of sensor, straight pipe length in sequence, and Reynolds number. Three-dimensional numerical analysis has been conducted to understand the flow patterns downstream of a double bent pipe. Numerical analysis shows that the results well agreed with the experimental ones in case of a sensor mounting angle of $0^{\circ}$ and L/D = 3, 5 of $45^{\circ}$, $135^{\circ}$ in a single path. As a result, when the Reynolds number is 700,000-1,400,000, the sensor error of a single-path ultrasonic flowmeter is reduced with the mounting condition of L/D = 3, $45^{\circ}$.
Keywords
Double Bent Pipe; Ultrasonic Flowmeter; Correlation; Secondary Flow; Regression Analysis; Numerical Analysis;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 KS B ISO/TR 12765, 2005, "Measurement of Fluid Flow in Closed Conduits - Methods Using Transit-time Ultrasonic Flowmeters." Korea
2 Ministry of Environment, 2007, "Guidance for Flowmeter Installation and Maintenance." Korea
3 JEMIS-032, 1987, "Method of Flow Measurement by Ultrasonic Flowmeters." Japan
4 Rudolf, P. and Desova, M., 2007, "Flow Characteristics of Curved Ducts," Applied and Computational Mechanics 1, pp. 255-264.
5 KRISS, 1991, "A Characterization Study for Installation Effects on Various Flowmeter(II)." Korea
6 Koizumi, J., 2008, "Evaluation of Measuring Accuracy by Multi-path," Test Report of Tokimec Inc., Japan
7 Carlander, C. and Delsing, J., 2000, "Installation Effects on an Ultrasonic Flow Meter with Implications for Self Diagnostics," Flow Measurement and Instrumentation 11, pp. 109-122.   DOI   ScienceOn
8 Lee, D. K. and Cho, Y., 2011, "Error Characteristics of Clamp-on Ultrasonic Flowmeters Depending on Location of Sensors and Downstream Straight Run of Bent Pipe," Trans. Korean Soc. Mech. Eng. B, Vol. 35, No. 8, pp. 861-868.   과학기술학회마을   DOI   ScienceOn
9 International Organization for Standard, First Edition 1993, Corrected and Reprinted 1995, "Guide to the Expression of Uncertainty in Measurement," Geneva, Switzerland.
10 Ha, S. J., Cho, Y. K., Cho, M. W. and Lee, K. C., 2012, "Process Capability Optimization of a LED Die Bonding Using Response Surface Analysis," Journal of the Korea Academia-Industrial Cooperetion Society, Vol. 13, No. 10, pp. 4378-4384.   과학기술학회마을   DOI   ScienceOn
11 Patanka, S. V., Pratap, V. S. and Spalding, D. B., 1975, "Prediction of Turbulent Flow in Curved Pipes," J. Fluid Mech., Vol. 67, Part 3, pp. 583-595.   DOI   ScienceOn