• Title/Summary/Keyword: 3-Dimensional Measurement

Search Result 1,256, Processing Time 0.034 seconds

Construction of Database on Turbulent Properties of a Circular Cylinder with a 3D-PTV Technique (3차원 PTV에 의한 원주후류 난류통계량 데이터베이스 구축)

  • Doh D. H.;Cho Y B.;;Pyeon Y. B.;Baek T. S.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.249-252
    • /
    • 2002
  • Turbulent properties of the wake of a circular cylinder were measured The diameter of the cylinder is l0mm and the Reynolds number is 420. A new 3D-PTY system was constructed and a genetic algorithm (GA) was introduced in order to increase the number of instantaneous three-dimensional velocity vectors. In the GA two fitness functions were introduced in order to enhance the correspondences of the particles. The measurement system consists of three CCD cameras, Ar-ion laser, an image grabber and a host computer. More than 3000 instantaneous three-dimensional velocity vectors were obtained by the system. The database of the turbulent properties of the circular cylinder was constructed by the constructed 3D-PTV system.

  • PDF

Development of Holographic Particle Velocimetry System and Its Application to Spray Droplets (홀로그래피 입자속도 측정시스템의 개발과 분무 액적에의 적용)

  • Choo, Y.J.;Kang, B.S.
    • Journal of ILASS-Korea
    • /
    • v.10 no.3
    • /
    • pp.17-28
    • /
    • 2005
  • The Holographic Particle Velocimetry system can be a promising optical tool for the measurements of three dimensional particle velocities. In this study, diffused illumination holographic system to measure the sizes and 3D velocities of moving particles based on automatic image processing was developed. First of all basic optical systems for pulse laser recording, continuous laser reconstruction, and image acquisition, were constructed. To determine the position of particles in the optical axis, new three auto-focusing parameters(AEP), namely, Correlation Coefficient, Sharpness Index, and Depth Intensity were introduced and verified. The developed system was applied to spray droplets to validate the capability of the system. Three dimensional positions of particles viewed from two sides were decided using AFP and then 3D velocities of Particles were extracted by particle tracking algorithm. Comparison of measurement results of sizes and 3D velocities of particles with those obtained by laser instrument, PDPA, showed good consistency of the developed holographic system.

  • PDF

A Study of Three-dimensional evaluation of the accuracy of resin provisional restorations fabricated with the DLP printer (DLP 프린터로 제작된 레진 임시수복물의 3차원적 정확도 평가)

  • Kang, Wol;Lee, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.42 no.1
    • /
    • pp.35-41
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the accuracy of the DLP 3D printer by conducting 3-dimensional assesment of resin provisional restorations. Methods: The first premolar of the maxillary was prepared for the abutment. The abutment was scanned by using a scanner. The provisional restoration was designed by using CAD software. A total of 16 resin provisional restorations were produced using ZD200 and Veltz DLP 3D printer. Scanning was done of resin provisional restorations and 3-dimensional measurement was conducted for accuracy. The mean (SD) of RMS was reported for each group. Independent t-test was used to assess the statistical significance of the results. All analyses were done using SPSS 22.0. Results: The mean ± SD of RMS value for the accuracy of the resin provisional restorations that was fabricated by using ZD200 and Veltz DLP 3D printer were 50.85.±4.64㎛ and 70.33±6.31㎛. Independent t-test showed significant differences between groups(p<0.001). Conclusion: The resin provisional restorations made with DLP 3D printers showed clinically acceptable accuracy.

Measurements of the Trajectories of Moving Objects with Video System and Image Matching (비디오 시스템과 영상매칭에 의한 운동물체의 거동측정)

  • 이창경;조우석
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.20 no.3
    • /
    • pp.331-341
    • /
    • 2002
  • In order to extract 3-dimensional information from 2-D image, stereo images are prerequisite. Moreover, for the measurement of moving objects, the synchronized sequential stereo images have to be captured and image matching should be implemented for determining the location of moving objects. In this research, a simple method computing 3-dimensional coordinates from sequential images of moving objects was implemented. The sequential stereo images were captured by a video camera with a beam splitter. Once video images were digitalized by frame grabber, the interest points were extracted and matched in each stereo image, and the coordinates of center of them are calculated using weighted average method. Then, 3-dimensional coordinates of moving objects were computed by DLT algorithms.

Displacement Measurement of an Existing Long Span Steel Box-Girder using TLS(Terrestrial Laser Scanning) Displacement measurement Model (TLS 변위계측모델을 이용한 장스팬 철골 박스형 거더의 변위 계측)

  • Lee, Hong-Mn;Park, Hyo-Seon;Lee, Im-Pyeong;Kwon, Yun-Han
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.53-56
    • /
    • 2007
  • It was previously introduced a new displacement measuring technique using terrestrial laser scanning (TLS) that remotely samples the surface of an object using laser pulses and generates the three-dimensional (3D) coordinates of numerous points on the surface. In this paper, for an assessment of the capabilities of the measuring technique about existing structures, the field tests for vertical displacement measurement of an existing long span steel box-girder are experimentally carried out. The performance of the technique is evaluated by comparing the displacements obtained from TLS system and displacements directly measured from linear variable displacement transducer (LVDT).

  • PDF

Measurement of Material Deformation Using Laser Speckle (레이저 스페클을 이용한 재료 변형 측정)

  • 전문창;강기주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.688-694
    • /
    • 2002
  • As a tool for strain measurement to work with screw driven or hydraulic material test systems, in which mechanical vibration is inherent, SSDG(Speckle Strain/Displacement Gage), ESP(Electronic Speckle Photography) and its 3-dimension version SDSP are investigated for the theory and practical appliance. Through tension test of steel strips, their validity and shortcomings are examined. As the results, it has been shown that, although SSDG and ESP provide direct measurement of in-plane strain in one direction, they are so sensitive to the out-plane displacement. On the other hand, SDSP which is aided with DIC (Digital Image Correlation) technique to trace the movement of the speckles provides not only in-plane 2-dimensional displacement field, but also out-of-plane displacement simultaneously. However, because the DIC is time-consuming, not automated yet and it needs post-processing to evaluate strain from the displacement field, SDSP appears to be not adequate as a real time sensor.

  • PDF

On-Machine Measurement Error Compensation Using Ball-bar System (볼바 시스템을 이용한 기상측정오차 보정)

  • 이세희;서태일;조명우
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.2
    • /
    • pp.56-63
    • /
    • 2001
  • The objective of this research is to develop a measurement error compensation method for On-Machine Measurement (OMM) process based on a closed-loop configuration. Geometric errors of vertical machining center are measured using ball-bar system, and probing errors are measured using master ball. The errors are represented using homogeneous trans-formation matrices and the closed-loop configuration method is applied to calculate 3-dimensional errors. To verify the effectiveness of the method proposed in this research, compensated results are compared to the data using CMM process, and the results are analyzed. The results show the proposed method can be applied in OMM process to make the measured data more reliable.

  • PDF

Three-Dimensional Fluid Flow Analysis of Photoacoustic Spectroscopy Cell for Measurement of Automotive Exhaust Gas (자동차 배출가스 측정을 위한 Photoacoustic Spectroscopy Cell의 3차원 유동장 해석)

  • 김현철;박종호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.111-118
    • /
    • 2003
  • Recently, environmental damage to urban area becomes serious problem due to the exhaust emissions by increasing the number of vehicle. Especially, exhaust emission from diesel vehicles are blown to be harmful to human health and environment. Photoacoustic Spectroscopy system is very useful technology for simultaneous and continuous measurement of the various components of the automotive exhaust gas. In this study, in order to reduce emission gases from automobile, we tried to develop the measurement system of Photoacoustic Spectroscopy. To improve performance of high sensitive Photoacoustic Spectroscopy system for automotive exhaust emissions, the shape of Photoacoustic Spectroscopy cell was optimized to use the flow analysis. And Exhaust emission data of the 1,500cc gasoline engine was fixed the working fluid. The characteristics of fluid flow for cell were analyzed by various conditions in detail.

Automatic Hand Measurement System from 2D Hand Image for Customized Glove Production

  • Han, Hyun Sook;Park, Chang Kyu
    • Fashion & Textile Research Journal
    • /
    • v.18 no.4
    • /
    • pp.468-476
    • /
    • 2016
  • Recent advancements in optics technology enable us to realize fast scans of hands using two-dimensional (2D) image scanners. In this paper, we propose an automatic hand measurement system using 2D image scanners for customized glove production. To develop the automatic hand measurement system, firstly hand scanning devices has been constructed. The devices are designed to block external lights and have user interface to guide hand posture during scanning. After hands are scanned, hand contour is extracted using binary image processing, noise elimination and outline tracing. And then, 19 hand landmarks are automatically detected using an automatic hand landmark detection algorithm based on geometric feature analysis. Then, automatic hand measurement program is executed based on the automatically extracted landmarks and measurement algorithms. The automatic hand measurement algorithms have been developed for 18 hand measurements required for custom-made glove pattern making. The program has been coded using the C++ programming language. We have implemented experiments to demonstrate the validity of the system using 11 subjects (8 males, 3 females) by comparing automatic 2D scan measurements with manual measurements. The result shows that the automatic 2D scan measurements are acceptable in the customized glove making industry. Our evaluation results confirm its effectiveness and robustness.

The Measurement of Femoral Neck Anteversion by 3D Modeling of Femoral Major Axes (대퇴골 주요축의 3차원 모델링에 의한 전염각의 측정)

  • Kim, Jun-Sik;Kim, Seon-Il
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.341-350
    • /
    • 1998
  • The accurate measurement of the femoral anteversion is important for the derotational osteotomy. To estimate femoral anteversion, following three major parameters are required; the neck axis, the long axis, and the knee axis. Conventional methods on the basis of 2D images are ambiguous to determine these major axes. As the femur has a complex 3 dimensional structure, the 3 dimensional model should be applied for accurate and reliable measurement of femoral anteversion. In this thesis, we model femur and define three parameters. The neck axis is defined from the femoral head and neck model. The long axis is determined from the cylindrical model of the femoral shaft. The knee axis is also determined from the model of femoral condyles. According to the definition of the femoral anteversion, the femoral anteversion is efficiently estimated from these models. 20 specimens were tested by the conventional 2D imaging method and 3D imaging method witch was developed by authors and the new 3D modeling method. The study provides accurate, fast and human factor free measurement for femoral anteversion.

  • PDF