• Title/Summary/Keyword: 3-D whole body scanning

Search Result 15, Processing Time 0.029 seconds

Development of Male Fitted Torso Type Basic Patterns According to the Body Surface Segment Method (체표면분할법에 의한 성인 남성용 피티드 토르소형 원형 설계)

  • Suh, Chu-Yeon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.7
    • /
    • pp.1109-1120
    • /
    • 2009
  • This study develops a fitted torso type basic pattern for men by utilizing 3D body scan data. Recent fashion trends are reflected in the development of the pattern. The subjects were 15 men in their 20's, who wear size 95 (M size). Body scan data was obtained through a 3D whole body scanner (WB4, Cyberware, USA), and a body surface development figure for developing male fitted torso type basic pattern was attained through the use of Rapid Form 2006 as well as Auto CAD 2006 programs. The results are as follows: A body surface development figure through body surface segment method showed high exactitude in an error range of 100$\pm$1%. In addition, it occurred in an error range of 100:1:3% because of the hard scanning conditions in the incline of the shoulder and armpit areas. However, the body surface development figure as well as the direct measurement results can be used as basic data for the given patternmaking since the error range falls into 100$\pm$3%. Dart amounts obtained from the average cross section were center back 2.2cm (24.3%), back armpit point 3.8cm (41.8%), front armpit point 3.0cm (33.9%). As shown the jacket pattern, the biggest dart amount was portioned out at the back armpit point. The drafting equations for the development pattern acquired are as follows; Full width=C/2+5cm, back length=height/4-1cm, armhole depth=(C/10+12cm)+3cm, back width=2C/10+2cm, front width=2C/10. The development pattern was a fitted torso basic pattern that was composed of 3 pieces, so it would be very useful in developing shirt or jacket patterns. According to the results of the evaluation of the developed pattern appearance, it obtained higher scores of over 3.5 points in almost items, meaning that the developed pattern is appropriate for a male fitted torso type basic pattern. It suggests a possibility of patternmaking from a body surface development figure in 2-D to prototype.

Application of Lower Body Girth Change Analysis Using 3D Body Scanning to Pants Patterns

  • Choi, Sun-Yoon;Ashdown, Susan P.
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.6
    • /
    • pp.955-968
    • /
    • 2010
  • Three-dimensional body data has been used in many industry fields including the apparel industry. This research used data from a study of the changes in lower body girth measurements from a 3D scan study of 25 female subjects aged 18 to 24 in four postures; a standing posture, a $120^{\circ}$ knee bend posture, a one pace stepping posture, and a sitting posture with a $90^{\circ}$ knee bend. We used the information on the difference between standing and seated measurements to adjust ease values for pants patterns an evaluation of the appearance, and the comfort of the pants. Waist girth in the sitting posture increased 8% compared to a standing posture and the hip girth measurement increased 7%. A basic pants pattern (pants A) with 2.4cm ease at the waist and 2.6cm ease at the hip was developed and a pants pattern (pants B) was developed using the rates of lower body girth change with a 5.7cm ease (8% change) at the waist and 7cm ease (7% change) at the hip. The appearance assessment items of pants A in a standing posture were higher than pants B. On the other hand, most appearance assessment items of pants B in a sitting posture were higher than pants A, especially the ease of pants back waistline and the appearance of the whole back. Comfort assessment items of pants B in both standing and sitting postures were higher than the comfort assessment items for pants A, especially the location of pants waistline, the ease of pants at the waistline, and the ease at the abdomen. In order to find the best level of ease for better appearance and comfort in both standing and sitting postures, 20 pants were constructed with ease values at the waist and hip in increments of 1.1cm in the range between the ease values of pants A and pants B. A fit test was conducted to compare the average appearance and comfort ratings that identified the pants with the best ease values at the waist and hip. The highest total mean was achieved in the pants with a waist ease of 4.6cm and hip ease of 4.8cm.

Suggestion for Shape Measurement and Alloy Element Analysis of Korean Bells (한국종의 형상 및 합금성분 분석을 위한 제안)

  • Ko, Sun-Woo
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.4
    • /
    • pp.428-439
    • /
    • 2011
  • It is well known that the sound characteristics of Korean bell depend on the shape and the alloy constituents. Development of the methods to acquire exact shape data and alloy constituents of the whole body of the bell is very important for the study and systematic management of Korean bells. The practical scanning and modeling methods to get shape data from optical triangulation laser scanners are proposed. The 3D shape data by the proposed methods can be the basis of diverse measurements such as curvature, volume, thickness and the distance between any two points. A nondestructive alloy constituents measuring method which can overcome the limitations of partial data collection and damages to Korean bells is also suggested to get the whole alloy characteristics. Following the developed methods, the data of the shapes and alloy constituents of 18 Korean bells are collected and the errors of existing measurement data for the shape have been corrected.

The Design of Digital Human Content Creation System (디지털 휴먼 컨텐츠 생성 시스템의 설계)

  • Lee, Sang-Yoon;Lee, Dae-Sik;You, Young-Mo;Lee, Kye-Hun;You, Hyeon-Soo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.4
    • /
    • pp.271-282
    • /
    • 2022
  • In this paper, we propose a digital human content creation system. The digital human content creation system works with 3D AI modeling through whole-body scanning, and is produced with 3D modeling post-processing, texturing, rigging. By combining this with virtual reality(VR) content information, natural motion of the virtual model can be achieved in virtual reality, and digital human content can be efficiently created in one system. Therefore, there is an effect of enabling the creation of virtual reality-based digital human content that minimizes resources. In addition, it is intended to provide an automated pre-processing process that does not require a pre-processing process for 3D modeling and texturing by humans, and to provide a technology for efficiently managing various digital human contents. In particular, since the pre-processing process such as 3D modeling and texturing to construct a virtual model are automatically performed by artificial intelligence, so it has the advantage that rapid and efficient virtual model configuration can be achieved. In addition, it has the advantage of being able to easily organize and manage digital human contents through signature motion.

Establishment of In Vitro 3-Dimensional Culture System of Mouse Endometrial Cells;I. Cytohistological Study on Mouse Endometrium (마우스 자궁내막 세포를 이용한 3차원적 배양시스템 확립에 관한 연구; I. 마우스 자궁내막에 관한 세포조직학적 연구)

  • Nam, Hwa-Kyung;Kim, Eun-Young;Lee, Keum-Sil;Park, Sae-Young;Park, Eun-Mi;Kwon, Jung-Kyun;Yoon, San-Hyun;Park, Se-Pil;Lim, Jin-Ho
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.27 no.1
    • /
    • pp.31-37
    • /
    • 2000
  • This study was designed to identify the ultrastructural changes of mouse endometrium during peri-implantation period and obtain the fundamental information for the establishment of 3-dimensional culture system of mouse endometrial cells in vitro. The used female ICR mice ($6{\sim}8$ wks) were conducted on pregnant. The biopsies were obtained from whole uterus at cycle day 1 (D1) and day 5 (D5) after hCG injection and mating. The biopsies materials were fixed 2.5% glutaraldehyde and 1% osmium tetroxide. Subsequently, for observation using light and transmission electron microscopy (LM and TEM), they were dehydrated and embedded in Epon and the embedded biopsies were sectioned and stained. For scanning electron microscopy (SEM), the fixed specimens were dehydrated, dried and coated with gold. 1) For LM, the biopsied materials at D5 (late secretory phase) were appeared the extended stromal layer by increased connective tissues and the fully developed endometrial glands and vessels compared with D1 (early secretory phase). 2) For TEM, the mouse endometrium was consisted of 3-layers, a simple polarized columnar epithelial cells, basement membrane and stromal cells. At D5, the distribution of microvilli, endoplasmic reticulum, Golgi body, lipid and glycogen deposits, secretory granules and surface area of basement membrane were increased. 3) For SEM, the degree of folding and microvilli of surface of mouse epithelial cells was became more and more according to the process of secretory phase, and at D5, implantation time of mouse, the appearance of pinopodes as a specific marker of uterine receptivity was found. The uterine pinopodes of mouse were found in narrow sites at the luminal surface, irregularity and appeared the different stages in the same sample. Therefore, these results indicated that the mouse endometrium was experienced dramatic morphological changes during peri-implantation period.

  • PDF