• 제목/요약/키워드: 3-D standard Value

Search Result 367, Processing Time 0.029 seconds

Efficient 3D Model Retrieval using Discriminant Analysis (판별분석을 이용한 효율적인 3차원 모델 검색)

  • Song, Ju-Whan;Choi, Seong-Hee;Gwun, Ou-Bong
    • 전자공학회논문지 IE
    • /
    • v.45 no.2
    • /
    • pp.34-39
    • /
    • 2008
  • This study established the efficient system that retrieves the 3D model by using a statistical technique called the function of discriminant analysis. This method was suggested to search index, which was formed by the statistics of 128 feature vectors including those scope, minimum value, average, standard deviation, skewness and scale. All of these were sampled with Osada's D2 method and the statistics as a factor effecting a change turned the value of discriminant analytic function into that of index. Through the primary retrieval on the model of query, the class above the top 2% was drawn out by comparing the query with the index of previously saved class from the group of same models. This method was proved an efficient retrieval technique that saved its procedural time. It shortened the retrieval time for 3D model by 57% faster than the existing Osada's method, and the precision that similar models were found in the first place was recorded 0.362, which revealed it more efficient by 44.8%.

3D Image Evaluation of Aneurysm in Cerebral Angiography (뇌혈관조영검사에서 동맥자루 3D 영상 평가)

  • Kyung-Wan Kim;Kyung-Min Park;In-Chul Im
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.335-341
    • /
    • 2023
  • In this study, four algorithms (Standard, Bone, Dual volume, and Stent Follow up) were applied to the image of the aneurysm in cerebral angiography to reconstruct the image in 3D, and quantitatively evaluate Noise, SNR, and CNR based on the reconstructed image to find out the optimal algorithm. As an analysis method, Image J program, which can analyze images and calculate area and pixel values, was used for images reconstructed with four algorithms. In order to obtain Noise, SNR, and CNR, the region of interest (ROI) is measured by designating the point where the abnormal artery (aneurysm) is located and the surrounding normal artery in the image are measured, and the mean value and SD value are obtained. Background noise was set to two surrounding normal artery to increase reliability. The values of SNR and CNR were calculated based on the given formula. As a result, the noise was the lowest in the stent follow-up algorithm, and the SNR and CNR were the highest. Therefore, the stent follow-up algorithm is judged to be the most appropriate algorithm. The data of this study are expected to be useful as basic data for 3D image evaluation of the vascular and aneurysm in cerebral angiography, and it is believed that appropriate algorithm changes will serve as an opportunity to further improve image quality.

Improvement of the access channel algorithm in the CDMA2000 system (CDMA2000시스템에 있어서 액세스채널 알고리즘 개선)

  • Lee Kwang jai;Chun Jong hun;Park Jong an
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.3B
    • /
    • pp.138-143
    • /
    • 2005
  • This paper aims to optimize an access probe algorithm for the CDMA 2000 system. The incremental value of PWR_STEP increases as NUM_STEP as 1dBm±0.2 for access probe of the area with good receiving sensitivity when the mobile station transmits via access channel and does not receive any ACK message. However, for the area with weak receiving sensitivity, according to the algorithm of open-loop power control, the transmitting power amplifier becomes saturated and PWR_STEP incremental value keeps performing access probe to 0dBm±0.2. Therefore interference and battery consumption increases according to the transmission of the mobile station. We have optimized the access probe algorithm according to the receiving sensitivity. We transmit the incremental value of access probe power, with delaying as much RT slot value as indicated by IS-95C standard in case of good receiving sensitivity and with delaying RT+l slot value in case of weak receiving sensitivity. Simulation results showed that the proposed algorithm contributes to decrease of the interference and battery consumption according to the transmitting power of the mobile station and improves the call duration.

A 3D CFD analysis of flow past a hipped roof with comparison to industrial building standards

  • Khalil, Khalid;Khan, Huzafa;Chahar, Divyansh;Townsend, Jamie F.;Rana, Zeeshan A.
    • Wind and Structures
    • /
    • v.34 no.6
    • /
    • pp.483-497
    • /
    • 2022
  • Three-dimensional (3D) computational fluid dynamics (CFD) analysis of flow around a hipped-roof building representative of UK inland conditions are conducted. Unsteady simulations are performed using three variations of the k-ϵ RANS turbulence model namely, the Standard, Realizable, and RNG models, and their predictive capability is measured against current European building standards. External pressure coefficients and wind loading are found through the BS 6399-2:1997 standard (obsolete) and the current European standards (BS EN 1991-1-4:2005 and A1:20101). The current European standard provides a more conservative wind loading estimate compared to its predecessor and the k-ϵ RNG model falls within 15% of the value predicted by the current standard. Surface shear stream-traces and Q-criterion were used to analyze the flow physics for each model. The RNG model predicts immediate flow separation leading to the creation of vortical structures on the hipped-roof along with a larger separation region. It is observed that the Realizable model predicts the side vortex to be a result of both the horseshoe vortex and the flow deflected off it. These model-specific aerodynamic features present the most disparity between building standards at leeward roof locations. Finally, pedestrian comfort and safety criteria are studied where the k-ϵ Standard model predicts the most ideal pedestrian conditions and the Realizable model yields the most conservative levels.

Measurement and evaluation of speech privacy in university office rooms (대학 내 사무실의 스피치 프라이버시 측정 및 평가)

  • Lim, Jae-Seop;Choi, Young-Ji
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.396-405
    • /
    • 2019
  • The speech privacy of closed office rooms located in a university campus was measured and assessed in terms of SPC (Speech Privacy Class) values. The measurements of two quantities, the LD (Level Difference) between a source and a receiving room, and the background noise level ($L_b$) at the receiving room were carried out in 5 rooms located in 3 different buildings in the university campus. Each of the 5 rooms was adjacent to both offices and corridors through walls. The TL (Transmission Loss) between the source and the receiver room was also measured to compare the difference of two standard methods, ASTM E2836-10 and KS F 2809. The present results show that the speech privacy of the 5 office rooms is not met the requirement for a minimum SPC values of 70. A minimum LD value of 41 dB between the source and the receiver room should be achieved for having a SPC value of 70 when the mean measured value of $L_b$ at the receiving room is 29.2 dB. That is, the TL(avg) value averaged over the octave bands from 160 Hz to 5000 Hz between the source and the receiver room should be or greater than 40 dB. The most important architectural factor influencing the LD value is the presence of openings, such as doors, and windows, on the adjacent walls between the source and receiving room. Therefore, if the opening of the adjacent wall is replaced by an opening with high sound insulation, the appropriate SPC value of the research and office rooms can be achieved.

Blasting Standardization works for NATM on the Seoul Subway Construction by Dr, Ginn Huh (서울 지하철공사 발파공법의 표준화)

  • Heo, Jin
    • Journal of the Korean Professional Engineers Association
    • /
    • v.16 no.3
    • /
    • pp.5-23
    • /
    • 1983
  • On the Seoul Metropolitan Subway Construction of No. 3, 4 Line, the total length is 57 Km and it is now undergoing almost 55% progress. The working method is classified into Open Cut of 70% and the rest of 30% tunnelling method in the 48 job site. Above tunnelling method is execute by American Steel Support System and the rest of 10 job site carried out by New Austria Tunnelling Method. This paper describes Blasting Standardizations works on the above Tunnelling ' Open Cut Method under big slogan, first safety, second execution. As a superintendent, I strived standardization of works with Better powder, Better Drills ' Better Pattern. Geological structure of Seoul area is composed by Jurassic Granite and also the above rockgroup are over burden by Alluviums as a Unconformity. First of all, I carried out the standard amount of powder and burden through experimental standard blasting by each powder as following Blasting works in the subway construction is surrounding shop Building, under pass the city river and also under pass highest building basement floor. I made allowable Blasting Vibration Value by West-Germany Vornorm DIN 4150, Teil 3 and should measure each blasting works as fellows all of powder is used basically Low-Gravity and Low Velocity such as Slurry, Ammonium Nitrate ' Finex I, II. for Smooth Blasting Instead of Gelatin Dynamite. Electric Detonation Cap is used basically M/S Delay Cup instead of Electric delay ' Simultaneous cap. I applied following formula V=KW3/4 $D^{-2}$ V=Particle Velocity (Cm/sec) K=Ginh Huh's Value W=Delay Charge (Kg) D=Distance(m) In the Open Cut, within 1m distance from H-pile I made to use the Concrete breaker, as following V=7W/$^{0.5}$V/$^{-1.75}$ On the Concentrate Building area, I advise to use Light class drill ø36m Bit and advance 1.1m per round blasting the three boom jumbo drill over ø45mm used only suburb of city.e Light class drill ø36m Bit and advance 1.1m per round blasting the three boom jumbo drill over ø45mm used only suburb of city.

  • PDF

Evaluation of Service Life of Low Pressure LP-Gas Regulators for Home Use (가정용 LPG 저압조정기의 사용수명 평가)

  • Kim Young-Gyu;Kim Pil-Jong;Cho Seok-Beom;Kwon Boo-Kil
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.3 s.28
    • /
    • pp.44-48
    • /
    • 2005
  • Experimental works were carried out to evaluate the service life of low pressure LPG regulators for domestic use. Experimental results showed that the operating pressure of regulators used for 7 years notably deviated from the standard value of the adjusting pressure and the lock-up pressure. Thus, it is estimated that low pressure LPG regulators have approximately 6 years of service life.

  • PDF

Research on the Expression Features of Naked-eye 3D Effect of LED Screen Based on Optical Illusion Art

  • Fu, Linwei;Zhou, Jiani;Tae Soo, Yun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.15 no.1
    • /
    • pp.126-139
    • /
    • 2023
  • At present, naked-eye 3D appears more and more commonly on the facades of urban buildings. It brings an incredible visual experience to the audience by simulating the natural 3D 3D space effect. At the same time, it also creates enormous commercial value for city publicity and commercial advertisements. There is much research on naked-eye 3D visual effects, but for right-angle LED screens. Right-angle LED screen's brand-new expression method that has only become popular in recent years, how to convey a realistic naked-eye 3D effect through two LED screens combined at right angles has become a problem worth exploring. To explore the whole design ideas and production process of the naked-eye 3D impact of the right-angle LED screen, this paper is a preliminary study aimed at understanding the performance principle and expression features. Before the case analysis, first, understand the standard virtual 3D space construction techniques. Combining it with the optical illusion phenomenon, according to the expression principle of the naked-eye 3D effect of the right-angle LED screen, it can be summarized into seven expressions: Shadow, Color contrast, Background structure line, Magnify object, Object out of bounds, Object floating, Fusion of picture and background. By analyzing the optical illusion phenomenon used in the case, we summarized the main performance characteristics of the naked eye 3D effect. The emergence of right-angle LED screens breaks the limitation of a single plane of optical illusion art, perfectly combines building facades with naked-eye 3D visual effects, and provides designers with a brand-new creative platform. Understanding its production principles and main expressive features can help designers enter this innovative platform better.

The Study on critical Value of Kinematical Evaluation Variables of Lower Extremity Pronation in Biomechanical Evaluation of Running Shoes (운동화의 생체역학적 평가시 하지 회내운동의 운동학적 평가변인에 대한 상해 기준치 연구)

  • Kwak, Chang-Soo;Jeon, Min-Ju;Kwon, Oh-Bok
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.4
    • /
    • pp.175-187
    • /
    • 2006
  • The purpose of this study was to find the relationship between Achilles tendon angle, angular velocity from 2D cinematography utilized to easily analyze the functions of shoes, ankle joint moment, knee joint moment, and hip joint moment from 3D cinematography utilized to predict the injury. Also, this study was to provide the optimal standard to analyze the injury related to the shoes. Subjects in this study were 30 university male students and 18 conditions (2 types of running speed, 3 of midsole hardness, 3 of midsole height) were measured using cinematography and force platform. The results were as following. 1) Hip joint abduction moment was effected by many variables such as running speed, midsole height, maximum achilles tendon angle, ground reaction force. 2) Knee joint rotational moment in running was approximately 1/10 - 1/4 times of the injury critical value and eversion moment was approximately 1/4 - 1/2 times of the injury critical value. 3) Ankle joint pronation moment in running was 1/3 - 1/2 times of the injury critical value. 4) Knee joint rotational moment was found to be irrelevant with maximum achilles tendon angle or angular velocity. 5) Pronation from running was thought to be relevant to rather eversion moment activity than rotational moment activity of knee joint. 6) Plantar flexion abductor of ankle showed significant relationship with the ground reaction force variable. 7) When the loading rate for ground reaction force in passive region increased, extensor tended to be exposed to the injury. Main variables in biomechanical analysis of shoes were impact absorption and pronation. Among these variables, pronation factor was reported to be relevant with knee injury from long duration exercise. Achilles tendon angle factor was utilized frequently to evaluate this. However, as the results of this study showed, the relationship between these variables and injury relating variable of knee moment was so important. Studies without consideration on this finding should be reconsidered and reconfirmed.

A Study of Senior Men's Dress Form Development 3D Digital Technology (3D 디지털 기술을 활용한 시니어 남성 기성복 피팅용 드레스폼 개발에 관한 연구)

  • Do, Wolhee;Choi, Eunhee
    • Fashion & Textile Research Journal
    • /
    • v.20 no.6
    • /
    • pp.722-732
    • /
    • 2018
  • This study was to develop a dress form that is highly representative of the body shapes of senior men in their 50s and 60s. And this research was compared the measurements and forms of three different dress forms available in the market, in order to analyze the body type and suitability and provide a standard for developing and utilizing the dress forms. After extracting the body shapes of the senior men's 3D shape, the body type that is curvature on the back prevalent among senior men, was chosen. The dress form was created as follows: 3D modeling and rendering, printing with a FDM-type 3D printer. The dress forms were 3D-scanned and the 3D data was analyzed - classification drop value, area deviation, compared horizontal section and vertical section. The results were as follows: This suggested that the area deviation amount at the chest and hip circumference levels was larger in the commercial products than in the dress form in this study, while that at the waist circumference level was larger in the dress form in this study. The vertical length of the lateral shoulder point-waist circumference was smaller, the side shape showed severe curvature on the back, and the waist circumference was larger in the senior men dress form than the commercial products. The dress form developed in this study reflected the body type of senior men and, therefore, were suitable for fitting when creating clothes for senior men.