• Title/Summary/Keyword: 3-D position

Search Result 2,275, Processing Time 0.029 seconds

Time Change in Spatial Distributions of Light Interception and Photosynthetic Rate of Paprika Estimated by Ray-tracing Simulation (광 추적 시뮬레이션에 의한 시간 별 파프리카의 수광 및 광합성 속도 분포 예측)

  • Kang, Woo Hyun;Hwang, Inha;Jung, Dae Ho;Kim, Dongpil;Kim, Jaewoo;Kim, Jin Hyun;Park, Kyoung Sub;Son, Jung Eek
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.279-285
    • /
    • 2019
  • To estimate daily canopy photosynthesis, accurate estimation of canopy light interception according to a daily solar position is needed. However, this process needs a lot of cost, time, manpower, and difficulty when measuring manually. Various modeling approaches have been applied so far, but it was difficult to accurately estimate light interception by conventional methods. The objective of this study is to estimate the spatial distributions of light interception and photosynthetic rate of paprika with time by using 3D-scanned plant models and optical simulation. Structural models of greenhouse paprika were constructed with a portable 3D scanner. To investigate the change in canopy light interception by surrounding plants, the 3D paprika models were arranged at $1{\times}1$ and $9{\times}9$ isotropic forms with a distance of 60 cm between plants. The light interception was obtained by optical simulation, and the photosynthetic rate was calculated by a rectangular hyperbola model. The spatial distributions of canopy light interception of the 3D paprika model showed different patterns with solar altitude at 9:00, 12:00, and 15:00. The total canopy light interception decreased with an increase of surrounding plants like an arrangement of $9{\times}9$, and the decreasing rate was lowest at 12:00. The canopy photosynthetic rate showed a similar tendency with the canopy light interception, but its decreasing rate was lower than that of the light interception due to the saturation of photosynthetic rate of upper leaves of the plants. In this study, by using the 3D-scanned plant model and optical simulation, it was possible to analyze the light interception and photosynthesis of plant canopy under various conditions, and it can be an effective way to estimate accurate light interception and photosynthesis of plants.

3-D FEA on the intrusion of mandibular anterior segment using orthodontic miniscrews (교정용 미니스크류를 이용한 하악 전치 함입 시 변위양상의 3차원 유한요소분석)

  • Park, Hyun-Kyung;Sung, Eui-Hyang;Cho, Young-Soo;Mo, Sung-Seo;Chun, Youn-Sic;Lee, Kee-Joon
    • The korean journal of orthodontics
    • /
    • v.41 no.6
    • /
    • pp.384-398
    • /
    • 2011
  • Objective: The purpose of this study was to analyze the stress distribution and the displacement pattern of mandibular anterior teeth under various intrusive force vectors according to the position of orthodontic miniscrews and hooks, using three-dimensional finite element analysis. Methods: A three-dimensional finite element model was constructed to simulate mandibular teeth, periodontal ligament, and alveolar bone. The displacement of individual tooth on three-dimensional planes and the von Mises stress distribution were compared when various intrusion force vectors were applied. Results: Intrusive forces applied to 4 mandibular anterior teeth largely resulted in remarkable labial tipping of the segment according to the miniscrew position. All 6 mandibular anterior teeth were labially tipped and the stress concentrated on the labiogingival area by intrusive force from miniscrews placed mesial to the canine. The distointrusive force vector led to pure intrusion and the stress was evenly distributed in the whole periodontal ligament when the hook was placed between the central and lateral incisors and the miniscrew was placed distal to the canine. Conclusions: Within the limits of this study, it can be concluded that predictable pure intrusion of the 6 anterior teeth segment may be accomplished using miniscrews placed distal to the canine and hooks located between the central and lateral incisors.

Ultrasound Imaging of Normal Cardiac Structures with Convex Scanner in Puppies (강아지에서 컨벡스스캐너를 이용한 정상적인 심장구조물의 초음파상)

  • Jeong Soon-wuk;Park Hee-myung;Han Sook-hee;Yoon Jung-hee;Han Hong-ryul
    • Journal of Veterinary Clinics
    • /
    • v.11 no.2
    • /
    • pp.529-537
    • /
    • 1994
  • Sector scanner which has a conical end is used to image through the intercostal space because heart is protected by the ribs. Cardiac data published all around the world were also obtained by sector scanner. Although scanners being used in every small animal practice and animal hospital at college in Korea include convex ape and linear type, linear type is not appropriate f3r cardiac scan because of a wide contact surface. The purpose of this study is to establish ultrasonographic images of normal cardiac structures by measuring shape, size of reflectable cardiac structure according to restraint position in scanning normal heart of the puppies with 6.5 MHz convex scanner(SonoAce 4500, Medison, Korea) used in our veterinary teaching hospital, Seoul national university. Seventeen male and female puppies considered having healthy hear by X-ray and clinical examination are used feom April to July 1994. Scanning point selection of probe head and the distinction of imaged cardiac structures were accomplished by necropsy and cardiac scanning performed through thoracotomy under general anesthesia. At 10 o'clock position of transducer(at an angle of 30$^{\circ}$ between imaginary line from elbow joint to 3rd sternum and probe head, 60$^{\circ}$ from body surface, 4th intercostal space of right thorax) with the marker of scanner toward the head of dogs right atrium, left atrium and left ventricle were observed in 2, 3, 4, 5 intercostal space(2cm from the sternum) of experimental dog positioned ventrodorsally under general anesthesia. Under these conditions, the numerical values of imaged diastolic hear are as follows : the distance from skin to apex(mean$\pm$S.D) 47.53$\pm$6.94mm, thickness of left ventricular wall 6.00$\pm$1.60mm, length of left ventricle 16.27$\pm$5.31mm, width of left ventricle 15,33$\pm$4.25mm, length of left atrium 12.33$\pm$3.82mm, width of left atrium 11. 33$\pm$3.94mm, length of right atrium 1.00$\pm$2.41mm, width of right atrium 11.21$\pm$2.76mm and the area of left ventricle 270.92$\pm$109.81mm$^2$, area of left atrium 98.00$\pm$41.08mm$^2$, area of right atrium 62.75$\pm$21.04mm$^2$.

  • PDF

Carbon-induced reconstructions on W(110)

  • Kim, Ji-Hyeon;Rojas, Geoff;Anders, Axel;Kim, Jae-Seong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.362-362
    • /
    • 2010
  • Today, vast attention has been paid to periodic arrays of nanostructures due to their potential for applications such as memory with huge storage density. Such application requires large-scale fabrication of well ordered nano-sized structures. One of the most widely used methods for the ordered nanostructures is lithography. This top-down process, however, has the limit to reduce size. Here the promising alternative is the self-organization of ordered nano-sized structures such as large scale 2d carbon-induced reconstructions on W(110). In the present study, we report on the first well-resolved atomic resolution STM studies of the well-known R($15{\times}3$) and R($15{\times}12$) carbon induced reconstruction of the W(110). From the atomic image of R($15{\times}3$) for different values of tunneling gap resistance, we can tell there are no missing atoms in unit cells of R($15{\times}3$) and some atomic displacements are substantial from the clean W(110), even though not all the imaged position of atoms correspond to tungsten, but may include those of carbon. We are considering two cases; First case is related to lattice deformation, or top layer of W(110) is deformed in the process of relief of strain caused by random inserting of carbon atoms possibly in the interstitial position. In the second case, R($15{\times}3$) unit cell results from a coincidence lattice between clean W(110) substrate and tungsten carbide overlayer which has rectangular atomic arrangement and giving R($15{\times}3$) coincidence lattice. beta-W2C showing rectangular unit cell should be a candidate. Further, we report on new reconstructions. Unlike the well-known R($15{\times}12$) consisting of two parts, two inner structures between two "Backbone" structures. The new reconstruction, which we found for the first time, contains more parts between the "Backbone"s. Sometimes we can observe the reconstruction consists of only inner parts without "Backbone" parts. Thus, the observed reconstruction can be built by constructing of two types of "Lego"-like block. Moreover, the rectangle shape of "Backbone" transform to parallelogram-like shape over time, the so-called wavy-R($15{\times}12$). Adsorption of hydrogen can be the reason for this transformation.

  • PDF

Effects of wax rim in image registration of intraoral and face scan in edentulous arch condition (무치악 악궁에서 구강과 안면 스캔의 정합을 위한 왁스림의 활용 효과)

  • Sang-Hyeok Seo;Cheong-Hee Lee;Kyu-Bok Lee;So-Yeun Kim;Du-Hyeong Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.3
    • /
    • pp.135-141
    • /
    • 2024
  • Purpose: The purpose of this study was to investigate the accuracy of image merging of an intraoral scan of an edentulous arch to a facial scan using wax rim and markers. Materials and Methods: For registration of oral scan to face scan, a wax rim with markers was made. The markers were cuboid and divided into four groups according to size (5, 10 mm) and attachment location (midline, canine region). The evaluation of registration accuracy was compared with a standard created using cone-beam computed tomography data. Anterior linear variation of the edentulous arch and the 3D variation of the overall arch were measured. Kruskal-Wallis test and Mann-Whitney U test were used for statistics, and the significance level was set at 0.05 and evaluated under Bonferroni correction (0.05/6 = 0.083). Results: In the anterior deviation and global deviation results, there was no statistically significant difference in the oral scan position displacement values between the 5 mm and 10 mm groups. When the midline marker was used, the intraoral scan position displacement value was significantly lower than when only the canine marker was used. Conclusion: Marker attached wax rim can be used for image matching between facial and intraoral scans of the edentulous arch. Marker location at the middle area increases the accuracy of image matching.

Two Possible Space Groups of Ttis(tekaethylammonium) [bis(trimetaphosphate $\kappa^3O, O^', O^{"}$)] Vanadate(3-),$[V(P_3O_9)_2](NC_8H_{20})3$ (Tris(tetraethylammnnium) [bis(trimetaphosphate $\kappa^3O, O^', O^{"}$)] Vamdate(3-),$[V(P_3O_9)_2](NC_8H_{20})_3$,의 두가지 가능한 공간군)

  • 서일환;이진호
    • Korean Journal of Crystallography
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 1994
  • Two possible space groups of the comfound, VP6N3018C24H:60, are: P 1, a=14.022(1), b=12.644(2), c= 12.640(1)A, a=8038(1), B=102.12(1), r=102.16(1), V=2124.1A3, Z=2, μ=0.47cm-1, d=1.46g/cm3, R=0.083 for 3350 independent reflections with Fo>4o IFI, and C2/c, a=19.32(2), b=16.32(2), c=14.02(1)A, B=105.98(5), β=105.98(5), V=4248.2A3, Z=4 R=0.083 for 1590 independent reflections with Fo>4c IFoI . In the space group P T, there are two monlecules in a unit cell. Vanadium atoms in the two monlecules occupy the two different special positions such that the complete monlecules are accomplished by the two independent center of symmetry. Therefore two different half molecules of bis(trimetaphosphate)vanadate and three molecules of tetraethylammonium are the asymmetric unit in a unit cell. In the space group C2/c, however, the vanadium atom is located at a special position with centrosymmetry, and a two-fold symmetry axis passes through C2/c, N2 and C25 atoms. Therefore the asymmrtic unit in a unit cell consists of a half molecule of bis(trimetaphosphate)vanadate and one and a half molecules of tetraethylammonium. All the molecular conformations in both space groups are very similar: six oxygen atoms coordinated to a vanadium atom in the bi s(trimetaphosphate)vanadate molecule form an octahedron and the four carbon atoms bonded to a nitrogen atom in the tetraethylammonium molecule are disordered so that the eight carbon atoms around nitrogen atom exhibit an irregular dodecahedral form.

  • PDF

Kinetics of a Cloned Special Ginsenosidase Hydrolyzing 3-O-Glucoside of Multi-Protopanaxadiol-Type Ginsenosides, Named Ginsenosidase Type III

  • Jin, Xue-Feng;Yu, Hong-Shan;Wang, Dong-Ming;Liu, Ting-Qiang;Liu, Chun-Ying;An, Dong-Shan;Im, Wan-Taek;Kim, Song-Gun;Jin, Feng-Xie
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.3
    • /
    • pp.343-351
    • /
    • 2012
  • In this paper, the kinetics of a cloned special glucosidase, named ginsenosidase type III hydrolyzing 3-O-glucoside of multi-protopanaxadiol (PPD)-type ginsenosides, were investigated. The gene (bgpA) encoding this enzyme was cloned from a Terrabacter ginsenosidimutans strain and then expressed in E. coli cells. Ginsenosidase type III was able to hydrolyze 3-O-glucoside of multi-PPD-type ginsenosides. For instance, it was able to hydrolyze the 3-O-${\beta}$-D-(1${\rightarrow}$2)-glucopyranosyl of Rb1 to gypenoside XVII, and then to further hydrolyze the 3-O-${\beta}$-D-glucopyranosyl of gypenoside XVII to gypenoside LXXV. Similarly, the enzyme could hydrolyze the glucopyranosyls linked to the 3-O-position of Rb2, Rc, Rd, Rb3, and Rg3. With a larger enzyme reaction $K_m$ value, there was a slower enzyme reaction speed; and the larger the enzyme reaction $V_{max}$ value, the faster the enzyme reaction speed was. The $K_m$ values from small to large were 3.85 mM for Rc, 4.08 mM for Rb1, 8.85 mM for Rb3, 9.09 mM for Rb2, 9.70 mM for Rg3(S), 11.4 mM for Rd and 12.9 mM for F2; and $V_{max}$ value from large to small was 23.2 mM/h for Rc, 16.6 mM/h for Rb1, 14.6 mM/h for Rb3, 14.3 mM/h for Rb2, 1.81mM/h for Rg3(S), 1.40 mM/h for Rd, and 0.41 mM/h for F2. According to the $V_{max}$ and $K_m$ values of the ginsenosidase type III, the hydrolysis speed of these substrates by the enzyme was Rc>Rb1>Rb3>Rb2>Rg3(S)>Rd>F2 in order.

Effects of implant alignment and load direction on mandibular bone and implant: finite element analysis (임플란트 배열과 하중 방향이 임플란트와 치조골에 미치는 유한요소 응력분석)

  • Chung, Hyunju;Park, Chan;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sang-Won;Yang, Hongso
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.3
    • /
    • pp.176-182
    • /
    • 2020
  • Purpose: To evaluate the effects of load direction, number of implants, and alignment of implant position on stress distribution in implant, prosthesis, and bone tissue. Materials and Methods: Four 3D models were made to simulate posterior mandible bone block: two implants and 3-unit fixed dental prosthesis (FDP) with a pontic in the center (model M1), two implants and 3-unit FDP with a cantilever pontic at one end (model M2), FDP supported by three implants with straight line placement (model M3) and FDP supported by three implants with staggered implant configuration (model M4). The applied force was 120 N axially or 120 N obliquely. Results: Peak von Mises stresses caused by oblique occlusal force were 3.4 to 5.1 times higher in the implant and 3.5 to 8.3 times higher in the alveolar bone than those stresses caused by axial occlusal force. In model M2, the connector area of the distal cantilever in the prosthesis generated the highest von Mises stresses among all models. With the design of a large number of implants, low stresses were generated. When three implants were placed, there were no significant differences in the magnitude of stress between staggered arrangement and straight arrangement. Conclusion: The effect of staggering alignment on implant stress was negligible. However, the number of implants had a significant effect on stress magnitude.

Crystallographic analysis of dehydrated fully Tl+-exchanged zeolite Y

  • Lim, Woo Taik;Kwon, Ji Hye;Choi, Sik Young;Kim, Young Hun;Heo, Nam Ho
    • Analytical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.278-286
    • /
    • 2005
  • The crystal structure of ($Tl_{71}$-Y ($Tl_{71}Si_{121}Al_{71}O_{384}$), ${\alpha}=24.706(3){\AA}$, dehydrated at 653 K and $8{\times}10^{-6}$ torr, has been determined by single-crystal X-ray diffraction techniques in the cubic space group $Fd\bar{3}m$ at 294(1) K. The structure was refined using all intensities to the final error indices (using only the 302 reflection for which $F_{\circ}$ > $4{\sigma}(F_0)$) $R_1=0.0602$ (based on F) and $R_w=0.1744$ (based on $F_2$). The 71 $Tl^+$ ions per unit cell are found at four crystallographically distinct positions. Site I' position in the sodalite cavity opposite D6Rs are each occupied by eighteen $Tl^+$ ions per unit cell; these $Tl^+$ ions are recessed ca. $1.45{\AA}$ into the sodalite cavity from their O(3) plane (Tl-O=2.701(15), $3.163(16){\AA}$ and O-Tl-O=$92.1(4)^{\circ}$). The 23 $T1^+$ ions fill site II in the supercage; these $T1^+$ ions are recessed ca. $1.58{\AA}$ into the supercage from their O(2) plane (Tl-O = 2.850(16), $3.156(16){\AA}$ and O-T1-O = $85.1(5)^{\circ}$). The 19 $Tl^+$ ions lie at site III' in the supercage near a triple 4-ring (Tl-O = 3.10(7), $3.39(5){\AA}$ and O-Tl-O = 47.8(9), $95.3(18)^{\circ}$) and the remaining II ions occupy another site III' near a triple 4-ring in the supercage (Tl-O = 2.81(4), $2.71(4){\AA}$ and O-Tl-O = $57.3(8)^{\circ}$).

Study of Dynamic Variation Aspect in Lung Volume due to Respiration in Stereotactic Body Radiotherapy Using Abdominal Compressor (복부압박장치를 이용한 정위적방사선치료 시 호흡에 따른 폐암 용적의 동적변이 양상에 대한 연구)

  • Park, Kwang Soon;Kim, Joo Ho;Park, Hyo Kook;Beak, Jong Geal;Lee, Sang Kyoo;Yoon, Jong Won;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.159-165
    • /
    • 2013
  • Purpose: Abdominal compressor is used to control breathing in stereotactic body radiotherapy for lung tumors frequently. We evaluated the dynamic variation aspect of internal tumor volume by breathing. Materials and Methods: We reviewed 20 lung cancer patients (7 upper lung patients, 4 middle lung patients, 9 lower lung patients) who received stereotactic body radiotherapy using abdominal compressor between April 2012 to April 2013. Coordinate shift values were obtained by using four-dimensional cone-beam CT (4D-CBCT) to investigate treatment set-up error and moving tumor position error. To investigate how much difference of each part, we compared 95% confidence interval, maximum values and minimum values of three-dimensional vector value and analyzed conformity degree through the Pearson square correlation coefficient. Results: 95% confidence interval of three-dimensional vector value of each part is 1.8~2.9 mm in upper lobe, 2.3~5.4 mm in middle lobe and 2.2~4.0 mm in lower lobe. Conformity degree was the result that respectively is LR direction 0.75, SI direction 0.68 and AP direction 0.63 in upper lobe, LR direction 0.82, SI direction 0.51 and AP direction 0.92 in middle lobe and LR direction 0.63, SI direction 0.50 and AP direction 0.34 in lower lobe. Conclusion: We showed difference by each site in lung tumor due to respiration by using abdominal compressor. Therefore, we must correct treatment set-up error as well as moving tumor position error by breathing. It is also considered to be useful that it is the use of 4D-CBCT when correcting the error due to various dynamic variation.

  • PDF