• 제목/요약/키워드: 3-D flow characteristic

검색결과 133건 처리시간 0.024초

2·3차원 모형을 이용한 자연하도 만곡부에서의 흐름특성 연구 (Study on the Flow Characteristics at Natural Curved Channel by 2D and 3D Models)

  • 안승섭;정도준;이상일;김위석
    • 한국환경과학회지
    • /
    • 제21권4호
    • /
    • pp.471-478
    • /
    • 2012
  • In this study, the flow characteristic analysis at the curved-channel of the actual channel section is compared and reviewed using the 2D RMA-2 model and the 3D FLOW-3D model. the curve section with curve rate 1.044 in the research section is analyzed applying the frequency of he project flood of 100 years. According to the result, the issue for the application of the FLOW-3D Model's three-dimensional numeric analysis result to the actual river is found to be reviewed with caution. Also, application of the 3D model to the wide basin's flood characteristic is determined to be somewhat risky. But, the applicability to the hydraulic property analysis of a partial channel section and the impact analysis and forecast of hydraulic structure is presumed to be high. In addition, if the parameters to reflect the vegetation of basin and the actual channel, more accurate topological measurement data and the topological data with high closeness to the current status are provided, the result with higher reliability is considered to be drawn.

NUMERICAL ANALYSIS OF FLOW CHARACTERISTIC WITH DIFFERENT CORNER RADIUS OF SQUARE CYLINDER

  • Gao, Zhefeng;Sohn, Chang-Hyun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.315-319
    • /
    • 2010
  • The near wake of square section cylinders with different corner radii is studied by numerical method to investigate the influence of corner radius. Eight models, R/D=0, 0.05, 0.1, 0.15, 0.2, 0.3, 0.4, 0.5 (R is the corner radius and D is the characteristic dimension of the body) at Re=500 were studied. The numerical results of St, CD and CL at R/D=0 and R/D=0.5 were compared with experiments to prove the feasibility and also investigate the trend of flow phenomena by the various radius corners. Results indicate that, as R/D ratio is increased, the Strouha lnumber is increased, the minimum pressure point on the cylinder surface moved own stream. The calculated results shows that between R/D=0.15 to R/D=0.3 have CD and CL.

  • PDF

7mm폭의 Micro Valve 자장 및 유동특성 고찰 (An Investigation into Micro Valve Field and Flow Field Characteristic of 7mm Width)

  • 전용식;김동수;신동윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.657-658
    • /
    • 2006
  • Recently, the micro on-off valves have been focused on core technology in the fields of the production line of semi-conductor chips and the micro fluid chips for bio-medical applications. A key characteristics for micro valve, operated by compressed air, are high speed response and great repeatability. Indeed, it is also important to keep the pressure on the cross-sectional area of the poppet to be constant regardless of the fluctuation of the pressure exerted on the ports. In this study, we have designed and analysed the high-speed and high flow rate micro on-off valve using the analogy of equivalent magnetic circuit and Finite Element Method(FEM) respectively. In case of poppet, flow field characteristic was analyzed by the variation of poppet and it was able to display flow field by changing the location of the poppet. Also, we verified possibility of the design through the static and dynamic pressure and the 3D distribution curve of the force by working the front poppet.

  • PDF

4-D PTV

  • Doh Deog Hee;OKAMOTO Koji
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 Proceedings of 2004 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.33-40
    • /
    • 2004
  • A 4D-PTV system was constructed. The measurement system consists of three high-speed high-definition cameras(1k x 1k, 2000fps), Nd-Yag laser(2000Hz) and a host computer. The GA-3D-PTV algorithm was used for completing the measurement system. The 4D-PTV is capable of probing the spatial distribution of velocity vectors of the flow field overcoming the temporal resolution of the characteristic turbulence length scales of the measured flow fields. A horizontal impinged jet flow (H/D=7) was measured. The Reynolds number is about 33,000. Spatial temporal evolution of the jet flow was examined and physical properties such as spatial distributions of vorticity and turbulent kinetic energy were obtained with the constructed.

  • PDF

수직 지질구조에 의해서 지배되는 암반지하수 유동의 수리적 성질과 그 예 (Hydraulic Eroperty of Groundwater Flow Controlled by Vertical Geologic Structure and its field Example)

  • 함세영;김형찬;임정웅
    • 대한지하수환경학회지
    • /
    • 제5권2호
    • /
    • pp.101-109
    • /
    • 1998
  • 암반대수층의 수리적 특성은 지하수의 통로가 되는 지질구조에 의해서 크게 좌우된다. 본 연구에서는 수직 지질구조와 관련된 일차원 흐름의 이론들에 대해서 논하였다. 그리고, 경북 영일군 대송면 옥명리에서 행한 두 번의 양수시험(양수시험 1과 양수시험 2)에 대해서, 프락탈 모델을 적용하여 이 지역 수리 특성을 분석하였다. 양수시험분석에 의하면, 양수시험 1(양수정 : D9호공, 관측정 : C3호공과 D7호공)의 시험공 주변은 무한한 길이의 그리고 무한소의 폭을 가지는 수직 지질구조에 의해서 지배되는 일차원 흐름으로 대표되나, 양수시험2의 양수정(D10호공) 주변은 이차원에 가까운 흐름(1.9∼2차원)을 보인다. 이와 같이, 균열암반대수층의 특징은 공간적으로 또는 시간적으로 유동 차원이 달라지는 경우가 많다.

  • PDF

불등이중관에 있어서의 유동특성과 번아우트 (제3보, 자연대유의 경우) (A Study on the Characteristic of Flow and Burnout in a Boiling Annulus (Part 2, Case of Natural Convection))

  • 조용철
    • 기계저널
    • /
    • 제16권2호
    • /
    • pp.84-91
    • /
    • 1976
  • An experimental investigation of the natural circulating boiling flow characteristic in three cases of annulus with different outer diameter, and the effect of annular gap size on the burnout behavior is presented. The experimental work was conducted for each case of test section at system pressure of $1kg/cm^2$ and inlet subcooling $0-20^{\circ}C$ in the full range of throttling ratio. As the result, the following facts were found. 1) With the increase of ${\Delta}T_{sub}$, $D_{2}$ and A/A_{o}$, $q_{BO}$ increases on the whole, and with the decrease of ${\Delta}T_{sub}$ and $D_{2}$, hydrodynamic instability is accelerated to happen prematually. 2)With the increase of ${\Delta}T_{sub}$, $D_{2}$ and A/A_{o}$ burnout characteristic shows the high velocitylow quality burnout, and with the decrease, low-velocity-high quality burnout. 3)With the decrease of A/A_{o}$, hyddrodynamic instability is singnificantly restrained and the difference of $q_{BO}$ in each $D_2$ under same condition is gradually reduced, finally converging into $1.9{\times}10^{5}kcal/m^{2}-hr$.

  • PDF

In vivo Evaluation of Flow Estimation Methods for 3D Color Doppler Imaging

  • Yoo, Yang-Mo
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권3호
    • /
    • pp.177-186
    • /
    • 2010
  • In 3D ultrasound color Doppler imaging (CDI), 8-16 pulse transmissions (ensembles) per each scanline are used for effective clutter rejection and flow estimation, but it yields a low volume acquisition rate. In this paper, we have evaluated three flow estimation methods: autoregression (AR), eigendecomposition (ED), and autocorrelation combined with adaptive clutter rejection (AC-ACR) for a small ensemble size (E=4). The performance of AR, ED and AC-ACR methods was compared using 2D and 3D in vivo data acquired under different clutter conditions (common carotid artery, kidney and liver). To evaluate the effectiveness of three methods, receiver operating characteristic (ROC) curves were generated. For 2D kidney in vivo data, the AC-ACR method outperforms the AR and ED methods in terms of the area under the ROC curve (AUC) (0.852 vs. 0.793 and 0.813, respectively). Similarly, the AC-ACR method shows higher AUC values for 2D liver in vivo data compared to the AR and ED methods (0.855 vs. 0.807 and 0.823, respectively). For the common carotid artery data, the AR provides higher AUC values, but it suffers from biased estimates. For 3D in vivo data acquired from a kidney transplant patient, the AC-ACR with E=4 provides an AUC value of 0.799. These in vivo experiment results indicate that the AC-ACR method can provide more robust flow estimates compared to the AR and ED methods with a small ensemble size.

교반조 바닥의 방해판이 유동특성 및 입자부유에 미치는 특성 (Characteristic of flow pattern and Particle Suspension in a Bottom Baffled Agitated Vessel)

  • 이영세
    • 한국산학기술학회논문지
    • /
    • 제16권2호
    • /
    • pp.1549-1554
    • /
    • 2015
  • 교반조 바닥에 방해판이 부착된 경우 유동특성 및 입자부유특성을 실험적으로 연구하였다. 입자의 유동상태는 교반조 바닥 중심으로부터 상승류가 증가하였다. 입자부유 실험으로부터 에크만 경계층의 발달에 의해 입자부유가 촉진됨을 알았다. 본 실험범위 내에서의 임펠러 및 교반조 바닥 방해판의 최적조건을 다음과 같이 나타내었다. 교반임펠러 최적조건 : $n_p=6$, d/D=0.5, b/d=0.3, 교반조 바닥 방해판 최적조건 ; $n_b=6$, $d_b/D=0.5$, $b_w/D=0.05$.

이중관 열교환기의 유체 유입위치와 회전길이에 따른 유동특성 (Flow Characteristic with Distance of Inlet Port and Rotating Length of Fluid in the Double Heat Exchanger)

  • 이승하;차동안;권오경
    • 동력기계공학회지
    • /
    • 제17권4호
    • /
    • pp.51-57
    • /
    • 2013
  • The length and position of the inlet port on the double tube heat exchanger is analyzed by CFX ver.11 for studying the characteristic of its flow distribution. When the boundary conditions of the inlet temperature and mass flow rate were each $20^{\circ}C$ and 10 ~ 50 kg/min, 3 models that are based on the distance between the inlet port and the center of the heat exchanger(0, 5.025, 10.05 mm) were analyzed to find the uniformity of the flow rate. Based on the flow rate, 4 lengths (23.723, 33.890, 44.057, 57.274 mm) were used to study the flow distribution according to Reynolds Number. The results show that, when the distance from the inlet to the position of the center of the heat exchanger is 10.05 mm and the length is 57.274 mm, the flow distribution is the most unified.

슬라이드 밸브 급폐쇄에 따른 디스크 주위 비정상유동의 PIV계측에 관한 연구 (A Study on PIV Measurement of Unsteady Flow around Disk caused by Slide Type Valve Quick Closing)

  • 이철재;조대환
    • 해양환경안전학회지
    • /
    • 제15권3호
    • /
    • pp.251-256
    • /
    • 2009
  • 이 연구에서는 전 유동장의 순간속도를 계측 할 수 있는 PIV계측기법을 슬라이딩 밸브의 폐쇄 직후에 적용하고 짧은 시간에 발생하는 디스크 주위의 비정상 속도를 계측하여 유동특성을 실험적으로 고찰하였다. 순간유동장을 분석한 결과를 기존의 압력변동을 측정한 연구 결과에 비교 검토한 결과 슬라이드 밸브 급폐쇄에 따른 속도변동이 크게 나타나는 시간구간은 0.1초 이내이고 주기는 0.12초로 추정되었다. 또한 원관 내부의 디스크 주위유동은 상부부터 폐쇄되면서 유로가 좁아져 순간적으로 빠르게 하류로 진행하였으며 폐쇄직후에 역류하는 속도의 크기는 4/120초까지 감소하다가 다시 증가하는 경향을 보였다. 그리고 완전 폐쇄 후 상류 측으로 역류하는 흐름의 영향으로 y/D=0.2 하부 영역에 역류하는 속도성분이 나타났으며, y/D=0.7, x/D=-0.3의 근방에서 0.2D 크기의 회전와류가 관찰되었다.

  • PDF