• Title/Summary/Keyword: 3-D display system

Search Result 601, Processing Time 0.028 seconds

A Study of Guide System for Cerebrovascular Intervention (뇌혈관 중재시술 지원 가이드 시스템에 관한 연구)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Yoon, Kwon-Ha;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.17 no.1
    • /
    • pp.101-107
    • /
    • 2016
  • Due to the recent advancement in digital imaging technology, development of intervention equipment has become generalize. Video arbitration procedure is a process to insert a tiny catheter and a guide wire in the body, so in order to enhance the effectiveness and safety of this treatment, the high-quality of x-ray of image should be used. However, the increasing of radiation has become the problem. Therefore, the studies to improve the performance of x-ray detectors are being actively processed. Moreover, this intervention is based on the reference of the angiographic imaging and 3D medical image processing. In this paper, we propose a guidance system to support this intervention. Through this intervention, it can solve the problem of the existing 2D medical images based vessel that has a formation of cerebrovascular disease, and guide the real-time tracking and optimal route to the target lesion by intervention catheter and guide wire tool. As a result, the system was completely composed for medical image acquisition unit and image processing unit as well as a display device. The experimental environment, guide services which are provided by the proposed system Brain Phantom (complete intracranial model with aneurysms, ref H+N-S-A-010) was taken with x-ray and testing. To generate a reference image based on the Laplacian algorithm for the image processing which derived from the cerebral blood vessel model was applied to DICOM by Volume ray casting technique. $A^*$ algorithm was used to provide the catheter with a guide wire tracking path. Finally, the result does show the location of the catheter and guide wire providing in the proposed system especially, it is expected to provide a useful guide for future intervention service.

Eye Contact System Using Depth Fusion for Immersive Videoconferencing (실감형 화상 회의를 위해 깊이정보 혼합을 사용한 시선 맞춤 시스템)

  • Jang, Woo-Seok;Lee, Mi Suk;Ho, Yo-Sung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.7
    • /
    • pp.93-99
    • /
    • 2015
  • In this paper, we propose a gaze correction method for realistic video teleconferencing. Typically, cameras used in teleconferencing are installed at the side of the display monitor, but not in the center of the monitor. This system makes it too difficult for users to contact each eyes. Therefore, eys contact is the most important in the immersive videoconferencing. In the proposed method, we use the stereo camera and the depth camera to correct the eye contact. The depth camera is the kinect camera, which is the relatively cheap price, and estimate the depth information efficiently. However, the kinect camera has some inherent disadvantages. Therefore, we fuse the kinect camera with stereo camera to compensate the disadvantages of the kinect camera. Consecutively, for the gaze-corrected image, view synthesis is performed by 3D warping according to the depth information. Experimental results verify that the proposed system is effective in generating natural gaze-corrected images.

The effect of inter-pupillary distance on stereopsis (동공간 거리가 입체시 지각에 미치는 영향)

  • 감기택;이주환
    • Korean Journal of Cognitive Science
    • /
    • v.14 no.3
    • /
    • pp.37-49
    • /
    • 2003
  • Most 3D display systems heavily depend on binocular disparity to produce 3-dimensional depth of a scene. In principle, the vergence angle of the object on fixation and binocular disparity of non-fixated objects vary with the inter-pupillary distance(IPD) of the observer. However, most stereo systems provide the identical stereo image pairs regardless of the observers' IPD, which may result in variation in the perceived depth. In this study, we manipulated the vergence angle of the fixated object and binocular disparity of the non-fixated object. The range of the individual difference in the perceived depth was found to be increased with the increase of disparity for both the fixated and non-fixated objects, and the individual difference was well fitted by the regression line of the observers' IPD. These results suggest that individual difference in the perceived depth from the identical stereo images should be greatly reduced if the stereo system calibrates the disparity of the object by the observers' IPD in generating the stereo images and the regression line found in this study might be useful in the calibrating the disparity of the images.

  • PDF

High-Precision and 3D GIS Matching and Projection Based User-Friendly Radar Display Technique (3차원 GIS 정합 및 투영에 기반한 사용자 친화적 레이더 자료 표출 기법)

  • Jang, Bong-Joo;Lee, Keon-Haeng;Lee, Dong-Ryul;Lim, Sanghun
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.12
    • /
    • pp.1145-1154
    • /
    • 2014
  • In recent years, as frequency and intensity of severe weather disasters such as flash flood have been increasing, providing accurate and prompt information to the public is very important and needs of user-friendly monitoring/warning system are growing. This paper introduces a method that re-produces radar observations as multimedia contents and applies reproduced data to mesh-up services. In addition, a accurate GIS matching technique to help to track the exact location going on serious atmospheric phenomena is presented. The proposed method create multimedia contents having structures such as two dimensional images, vector graphics or three dimensional volume data by re-producing various radar variables obtained from a weather radar. After then, the multimedia formatted weather radar data are matched with various detailed raster or vector GIS map platform. Results of simulation test with various scenarios indicate that the display system based on the proposed method can support for users to figure out easily and intuitively routes and degrees of risk of severe weather. We expect that this technique can also help for emergency manager to interpret radar observations properly and to forecast meteorological disasters more effectively.

Potential of Mean Force Calculations for Ion Selectivity in a Cyclic Peptide Nanotube

  • Choi, Kyu-Min;Kwon, Chan-Ho;Kim, Hong-Lae;Hwang, Hyon-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.3
    • /
    • pp.911-916
    • /
    • 2012
  • Ion selectivity in a simple cyclic peptide nanotube, composed of four cyclo[-(D-Ala-Glu-D-Ala-Gln)$_2-$] units, is investigated by calculating the PMF profiles of $Na^+$, $K^+$, and $Cl^-$ ions permeating through the peptide nanotube in water. The final PMF profiles of the ions obtained from the umbrella sampling (US) method show an excellent agreement with those from the thermodynamic integration (TI) method. The PMF profiles of $Na^+$ and $K^+$ display free energy wells while the PMF curve of $Cl^-$ features free energy barriers, indicating the selectivity of the cyclic peptide nanotube to cations. Decomposition of the total mean force into the contribution from each component in the system is also accomplished by using the TI method. The mean force decomposition profiles of $Na^+$ and $K^+$ demonstrate that the dehydration free energy barriers by water molecules near the channel entrance and inside the channel are completely compensated for by attractive electrostatic interactions between the cations and carbonyl oxygens in the nanotube. In the case of $Cl^-$, the dehydration free energy barriers are not eliminated by an interaction between the anion and the peptide nanotube, leading to the high free energy barriers in the PMF profile. Calculations of the coordination numbers of the ions with oxygen atoms pertaining to either water molecules or carbonyl groups in the peptide nanotube reveal that the stabilization of the cations in the midplane regions of the nanotube arises from the favorable interaction of the cations with the negatively charged carbonyl oxygens.

Design of Security Method for Network Rendering of Augmented Reality Object (홀로그램 용 증강현실 객체의 네트워크 랜더링을 위한 보안 기법 설계)

  • Kim, Seoksoo;Kim, Donghyun
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.1
    • /
    • pp.92-98
    • /
    • 2019
  • Due to the development of hologram display technology, various studies are being conducted to provide realistic contents for augmented reality. In the case of the HMD for hologram, since augmented reality objects must be rendered by a small processor, it is necessary to use a low-capacity content. To solve this problem, there is a need for a technique of rendering resources by providing resources through a network. In the case of the existing augmented reality system, there is no problem of contents modulation because the resources are loaded and rendered in the internal storage space. However, when providing resources through the network, security problems such as content tampering and malicious code insertion should be considered. Therefore, in this paper, we propose a network rendering technique applying security techniques to provide augmented reality contents in a holographic HMD device.

Gait Study on the Normal and ACL Deficient Patients After Ligament Reconstruction Surgery Using Chaos Analysis Method (전방십자인대 재건수술 환자와 정상인의 보행 연구)

  • Ko Jae-Hun;Moon Byung-Young;Suh Jeung-Tak;Son Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.4 s.247
    • /
    • pp.435-441
    • /
    • 2006
  • The anterior cruciate ligament(ACL) is an important stabilizer of knee joint. The ACL injury of knee is common and a serious ACL injury leads to ligament reconstruction surgery. Gait analysis is essential to identify knee condition of patients who display abnormal gait. The purpose of this study is to evaluate and classify knee condition of ACL deficient patients using a nonlinear dynamic method. The nonlinear method focuses on understanding how variations in the gait pattern change over time. The experiments were carried out for 17 subjects(l2 healthy subjects and five subjects with unilateral deficiency) walking on a motorized treadmill for 100 seconds. Three dimensional kinematics of the lower extremity were collected by using four cameras and KWON 3D motion analysis system. The largest Lyapunov exponent calculated from knee joint flexion-extension time series was used to quantify knee stability. The results revealed the difference between healthy subjects and patients. The deficient knee was significantly unstable compared with the contralateral knee. This study suggests an evaluation scheme of the severity of injury and the level of recovery. The proposed Lyapunov exponent can be used in rehabilitation and diagnosis of recoverable patients.

Interactions of methylated $\beta$-cyclodextrin and hydrophobically modified alkali-soluble emulsion (HASE) polymers: a rheological study

  • Gupta, R.K.;Tam, K.C.;Ong, S.H.;Jenkins, R.D.
    • Korea-Australia Rheology Journal
    • /
    • v.12 no.2
    • /
    • pp.93-100
    • /
    • 2000
  • The interactions between methylated $\beta$-cyclodextrin (CD) and hydrophobically modified alkali-soluble associative polymers (HASE) were examined by a rheological technique. The effect of "capping" of hydrophobes by methylated $\beta$-cyclodextrin on the viscosity and modulus was evaluated. Model HASE polymers with $C_1$to $C_{20}$ alkyl hydrophobic groups ethoxylated with~10 moles of ethylene-oxide (EO 10) and at concentrations up to 3 wt% were examined. With the addition of methylated $\beta$-CD, the steady shear viscosity profiles shift from a Newtonian profile to one that display a shear-thinning characteristic. Significant "capping" of the hydrophobes occurs for HASE polymers with $C_{l2}$, $C_{16}$ and $C_{20}$ hydrophobes as reflected by the large reduction in the viscosity. However, the steady shear viscosity remains constant when the concentration of $\beta$-CD exceeds 1 wt%, suggesting that $\beta$-CD is not able to fully encapsulate the hydrophobes of the HASE polymer. The temperature variation plots indicate that the activation energy of the HASE-EO10-$C_{20}$ system and $\beta$-CD is dependent on the magnitude of the applied shear stress. These results further reinforce the hypothesis that $\beta$-CD is not able to completely remove all the hydrophobic associations.phobic associations.

  • PDF

Application of the Chaos Theory to Gait Analysis (카오스 이론을 적용한 보행분석 연구)

  • Park, Ki-Bong;Ko, Jae-Hun;Moon, Byung-Young;Suh, Jeung-Tak;Son, Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.2 s.245
    • /
    • pp.194-201
    • /
    • 2006
  • Gait analysis is essential to identify accurate cause and knee condition from patients who display abnormal walking. Traditional linear tools can, however, mask the true structure of motor variability, since biomechanical data from a few strides during the gait have limitation to understanding the system. Therefore, it is necessary to propose a more precise dynamic method. The chaos analysis, a nonlinear technique, focuses on understand how variations in the gait pattern change over time. Eight healthy eight subjects walked on a treadmill for 100 seconds at 60 Hz. Three dimensional walking kinematic data were obtained using two cameras and KWON3D motion analyzer. The largest Lyapunov exponent from the measured knee angular displacement time series was calculated to quantify local stability. This study quantified the variability present in time series generated from gait parameter via chaos analysis. Knee flexion-extension patterns were found to be chaotic. The proposed Lyapunov exponent can be used in rehabilitation and diagnosis of recoverable patients.

Resolution enhanced integral imaging using super-resolution image reconstruction algorithm (초해상도 영상복원을 이용한 집적영상의 해상도 향상)

  • Hong, Kee-Hoon;Park, Jae-Hyeung;Lee, Byoung-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.10B
    • /
    • pp.1124-1132
    • /
    • 2009
  • We proposed a new method to improve the resolution of elemental image set in the integral imaging system using super-resolution image reconstruction method. Adjacent elemental images have same image region which is projected from the common area of object. These projected images in the elemental image can be used for low resolution images of super-resolution method. Two methods for resolution improvement of elemental image set using super-resolution method are proposed. One is super-resolution among the elemental image sets and the other is among the elemental images. Simulation results are compared with resolution improved elemental image set using interpolated method.