• Title/Summary/Keyword: 3-D Analytical Method

검색결과 483건 처리시간 0.033초

Liquid chromatographic enantioseparation of several amino acids as nitrobenzoxadiazole derivatives on polysaccharide trisphenylcarbamate derived chiral stationary phases

  • Suraj Adhikari;Alisha Bhandari;Wonjae Lee
    • 분석과학
    • /
    • 제36권4호
    • /
    • pp.143-151
    • /
    • 2023
  • Considering the greater role of α-amino acids in our daily lives, the enantiomer resolution of seven α-amino acids derivatized with fluorogenic reagent (4-fluoro-7-nitro-2,1,3-benzoxadiazole, NBD-F) by chiral HPLC on amylose or cellulose trisphenylcarbamate derived chiral stationary phases (CSPs) under simultaneous ultraviolet (UV) and fluorescence (FL) detection was performed. The degree of enantioseparation and resolution was affected by nature and selector backbones of the CSPs as well as the kind of amino acids. Baseline enantiomer separation and resolutions were observed for the enantiomers of all analytes as NBD derivatives especially on coated type amylose tris(3,5-dimethylphenylcarbamate) derived CSPs (Chiralpak AD-H and Lux Amylose-1). The other CSPs also showed good enantioselectivity except for the CSPs (Chiralpak IB, Chiralcel OD-H and Lux Cellulose-1) having cellulose tris(3,5-dimethylphenylcarbamate) as chiral selectors. The developed analytical chiral method was applied to determine the enantiomeric purity of seven commercially available L-α-amino acids and the impurities as D-forms were found to be in the range 0.08-0.87 %, respectively. The intra- and interday accuracy and precision assays showed high accuracy and precision of the developed analytical method. This chiral HPLC method for the enantiomer resolution of amino acids using fluorescent derivatization could be useful for the determination of enantiomeric purity of pharmaceuticals and biological study for amino acid type compounds among chiral drugs.

Equivalent moment of inertia of a truss bridge with steel-concrete composite deck

  • Siekierski, Wojciech
    • Structural Engineering and Mechanics
    • /
    • 제55권4호
    • /
    • pp.801-813
    • /
    • 2015
  • Flexural stiffness of bridge spans has become even more important parameter since Eurocode 1 introduced for railway bridges the serviceability limit state of resonance. For simply supported bridge spans it relies, in general, on accurate assessment of span moment of inertia that governs span flexural stiffness. The paper presents three methods of estimation of the equivalent moment of inertia for such spans: experimental, analytical and numerical. Test loading of the twin truss bridge spans and test results are presented. Recorded displacements and the method of least squares are used to find an "experimental" moment of inertia. Then it is computed according to the analytical method that accounts for joint action of truss girders and composite deck as well as limited span shear stiffness provided by diagonal bracing. Finally a 3D model of finite element method is created to assess the moment of inertia. Discussion of results is given. The comparative analysis proves efficiency of the analytical method.

Differential analysis of amikacin and butirosin

  • Nam, Doo-Hyun;Ryu, D.Y.
    • Archives of Pharmacal Research
    • /
    • 제5권2호
    • /
    • pp.87-91
    • /
    • 1982
  • In order to develop an analytical method for amikacin and butirosin in presence of their parent antibiotics, kanamycin A and ribostamycin, high-performance liquid chromatographic technique and microbioassay method were evaluated and compared. Using high performance liquid chromatography, two acylated antibiotics, amikacin and butirosin was partially separated from their parent antibiotics, to provide a qualitative analytical method. In microbioassay using Pseudomonas aeruginosa TI-13, a producer of aminoglycoside-3-phosphotransferase I, only acylated antibiotics were selectively analyzed when paper disc-susceptibility assay was used. The standard curve showed a good correlation between the response and odse in semilogarithmic plat with correlation coefficients above 0.96, and analytical deviation from expected dose was within 10%.

  • PDF

양면 인쇄법을 이용한 중금속 검출용 3D 종이 기반 분석장치 제작 (Fabrication of 3D Paper-based Analytical Device Using Double-Sided Imprinting Method for Metal Ion Detection)

  • 최진솔;정헌호
    • 청정기술
    • /
    • 제28권4호
    • /
    • pp.323-330
    • /
    • 2022
  • 미세유체 종이-기반 분석 장치는 최근 현장 진단 및 환경 물질 감지를 포함한 다양한 적용가능성으로 주목을 받고 있다. 본 연구는 적은 비용과 간단한 검출 방법으로 중금속을 빠르게 검출할 수 있는 3D-μPAD를 제작하기 위해 PDMS 양면 인쇄 방법을 제안하였다. 3D-μPAD 디자인은 레이저 커팅으로 아크릴 스탬프에 적용할 수 있으며, 제작된 스탬프에 PDMS 고분자를 스핀 코팅 후 양면접촉인쇄 방식 도입을 통해 3차원 형태의 소수성 장벽 형성에 필요한 조건을 확인하였다. 구체적으로 소수성 장벽 형성 조건인 고분자 농도, 스핀 코팅 속도 및 접촉 시간에 따라 PDMS 소수성 장벽 면적과 친수성 채널의 면적 변화를 분석함으로써 3D-μPAD 제작 공정 조건 최적화를 수행하였다. 최적화된 μPAD로 니켈, 구리, 수은 이온, pH를 다양한 농도에서 검출하였고 이를 ImageJ 프로그램으로 분석하여 grayscale 값으로 정량화 하였다. 이를 통해 3D-μPAD를 제작함으로써 특별한 분석 기기 없이 다양한 중금속 비색 검출을 수행함으로써 조기진단 바이오 센서로의 응용 가능성을 증명하였다. 이 3D-μPAD는 휴대가 간편한 다중 금속이온 검출 바이오센서로서, 신속한 현장 모니터링이 가능하므로 개발도상국 같은 자원이 제한된 지역에서 유용하게 사용 가능하다.

Accuracy evaluation of 3D time-domain Green function in infinite depth

  • Zhang, Teng;Zhou, Bo;Li, Zhiqing;Han, Xiaoshuang;Gho, Wie Min
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제13권1호
    • /
    • pp.50-56
    • /
    • 2021
  • An accurate evaluation of three-dimensional (3D) Time-Domain Green Function (TDGF) in infinite water depth is essential for ship's hydrodynamic analysis. Various numerical algorithms based on the TDGF properties are considered, including the ascending series expansion at small time parameter, the asymptotic expansion at large time parameter and the Taylor series expansion combines with ordinary differential equation for the time domain analysis. An efficient method (referred as "Present Method") for a better accuracy evaluation of TDGF has been proposed. The numerical results generated from precise integration method and analytical solution of Shan et al. (2019) revealed that the "Present method" provides a better solution in the computational domain. The comparison of the heave hydrodynamic coefficients in solving the radiation problem of a hemisphere at zero speed between the "Present method" and the analytical solutions proposed by Hulme (1982) showed that the difference of result is small, less than 3%.

고온초전도 케이블의 전자계 해석 (Electromagnetic Field Analysis Of High Temperature Superconducting Cable)

  • 조영식;홍정표;정종만;조전욱;성기철;권영길;류강식
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.60-62
    • /
    • 2000
  • It is widely acknowledged that the value of critical current in High Temperature Superconducting (HTS) tape has a great influence on B. Therefore, when HTS cable is designed, a method to reduce the B should be considered in order to improve the capacity. This paper deals with the influence of the space between each HTS tape by using 2D analytical method. From the analysis results, it is found that the decrease of the space causes the decrease of B. Moreover, another HTS cable, which has a very small space, is analyzed by 3D analytical method and it is manufactured. The validity of these analysis results are verified by comparison with experimental results.

  • PDF

실리콘에 MeV로 이온주입된 AS 와 Sb의 profile과 열처리에 의한 이온의 거동에 관한 연구 (A study of profiles and annaealing behavior of As and Sb by MeV implantation in silicon)

  • 정원채
    • 전자공학회논문지D
    • /
    • 제35D권3호
    • /
    • pp.46-55
    • /
    • 1998
  • This stud demonstrates the profiles of heavy ions (As, Sb) in silicon by high energy (1~10 MeV) implantation. Implanted profiles were measured by SIMS (Cameca 4f) and compared with simulation results (TRIM) program and analytical description method using Pearson function). The experimental results have a little bit deviation with simulation data in the case of As high energy implatation. But in the case of Sb, the experimental results are in good agreement with TRIM data. SIMS profiles are perfectly fitted with a analytical description method only using one pearson function in Sb implantation. but in the case of As, fitted profilesshow with a little bit deviations by channeling effects of SIMS profiles. Thermal annealing for electrical activation of implanted ions was carried out by furnace annealing and RTA(Rapid Thermal Annealing). Concentration-depth profile after heat treatement were measured by SR(Spreading Resistance) method.

  • PDF

Heat Transfer from each surface for a 3-D Thermally Asymmetric Rectangular Fin

  • Kang, Hyung Suk
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제4권2호
    • /
    • pp.153-163
    • /
    • 2000
  • The non-dimensional convective heat losses from each surface are investigated as a function of the non-dimensional fin length, width and the ratio of upper surface Biot number to bottom surface Biot number (Bi2/Bi1) using the three-dimensional separation of variables method. Heat loss ratio in view of each surface with the variation of Bi2/Bi1 is presented. The variation of the non-dimensioal temperare profile along the fin center line for a thermally asymmetric conditions is also presented.

  • PDF

Optimization of a 3-D Thermally Asymmetric Rectangular Fin

  • 강형석
    • Journal of Mechanical Science and Technology
    • /
    • 제15권11호
    • /
    • pp.1541-1547
    • /
    • 2001
  • The non-dimensional fin length for optimum heat loss from a thermally asymmetric rectangular fin is represented as a function of the ratio of the bottom surface Biot number to the top surface Biot number, fin tip surface Biot number and the non-dimensional fin width. Optimum heat loss is taken as 98% of the maximum heat loss. For this analysis, three dimensional separation of variables method is used. Also, the relation between the ratio of the bottom surface Biot number to the top surface Biot number and the ratio of the right surface Biot number to the left surface Biot number is presented.

  • PDF

40m 조합모듈교량 상부구조 이송에 따른 안전성 검토 (Safety Evaluation of 40m Combined Modular Bridge Super-Structures Based on Transportation Lifting Methods)

  • 박성민;정우영
    • 복합신소재구조학회 논문집
    • /
    • 제6권2호
    • /
    • pp.77-84
    • /
    • 2015
  • The purpose of this study was the analytical safety evaluation on the super-structure of precast modular bridge using standardized modular members and robotic construction during the transportation routing and lifting conditions. In order to evaluate the safety performance of the bridge system, 3-D full scale Finite Element (FE) of 40 m standardized modular block was developed in ABAQUS, followed by the analytical study to classify the structural system according to steel girder structures: 1) modular bridge block lifting method including the steel girder system; 2) modular bridge block lifting method without the steel girder system. The results from the analytical study revealed that the maximum stress of each modular member was within the maximum allowable stresses during lifting condition. However, the stress concentration at the connected area was more critical in comparison to the behavior of 40 m combined modular blocks during lifting time