• 제목/요약/키워드: 3-Axis Robot

검색결과 166건 처리시간 0.029초

CNC 선반용 4축 전용로봇의 모델링 및 시뮬레이션 (Modeling and Simulation of 4-Axis Dedicated Robot for CNC Lathe)

  • 김한솔;김갑순
    • 한국기계가공학회지
    • /
    • 제20권4호
    • /
    • pp.49-56
    • /
    • 2021
  • This paper describes the modeling and simulation of a four-axis dedicated robot that can attach and detach a workpiece on a computer numerical control (CNC) lathe. The robot was modeled as a Scarab robot for compatibility with CNC lathes. The advantages of such a robot are that an actuator with a small capacity can be used for the robot and the degrees of freedom of the robot can be reduced to four. For the simulation of the four-axis dedicated robot, a regular kinematic equation and an inverse kinematic equation were derived. Simulations were performed with these equations from the position of the loading device to the chuck position of the lathe before machining and from the chuck of the lathe to the position of the loading device after machining. The simulation results showed that the four-axis dedicated robot could be operated accurately, and they provided the joint angle of each motor (θ1, θ2, and θ3).

평형링크 메카니즘이 있는 관절형 로보트 회전축의 위치제어 (Position control of robot's rotational axis having parallel link mechanism)

  • 여인택;이연정
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1986년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 17-18 Oct. 1986
    • /
    • pp.341-345
    • /
    • 1986
  • In the course of robot control system building, there are problems in the position control loop of 3rd axis of robot manipulator. The problems are summerized as two: one is uncontrollability of position and the other is oscillation. And these problems are analyzed through experiment, and it is known that the cause of problems in torsional vibration of 3rd axis. So that these two problems are solved by noise immunity enhancement and lowering of PI controller gain.

  • PDF

관측성을 이용한 3축 SCARA Robot의 오차분석을 위한 Monte-Carlo simulation 및 측정 (Monte-Carlo Simulation and measuring for Error Analysis of 3-axis SCARA Robot using Observability)

  • 주지훈;정원지;김정현
    • 한국공작기계학회논문집
    • /
    • 제17권4호
    • /
    • pp.8-14
    • /
    • 2008
  • This paper aims at finding out dominant robot configurations with maximal position errors, which can be attributed to the parameter errors, by using Monte-Carlo simulation for error analysis of a 3-axis SCARA(Selective Compliance Assembly Robot Arm) type robot. In particular, the Monte-Carlo simulation is used for virtually measuring on the position errors, instead of physical measurement. In order to measure the observability of the model parameters with respect to a set of robot configurations, we propose the observability index which is defined as the product of singular values for error propagation matrices. Thus the index can be used for discriminating dominant robot configurations from a set of simulated ones in conjunction with standard deviation of positional errors, This paper analyzed error by robot positional error.

다리 환자를 위한 보행보조로봇의 종아리 링크 3축 힘센서 개발 (Development of Calf Link Force Sensors of Walking Assist Robot for Leg Patients)

  • 김한솔;김갑순
    • 센서학회지
    • /
    • 제26권2호
    • /
    • pp.114-121
    • /
    • 2017
  • This paper describes the design and fabrication of a three-axis force sensor with parallel plate beams (PPSs) for measuring the calf force while a patient with a walking assist robot is walking. Current walking assist robots can't measure the weight of the patient's leg and the robot's leg which required for robot control. So, the three-axis force sensor in the calf link is designed and manufactured, it is composed of a Fx force sensor, a Fy force sensor and a Fz force sensor. The three-axis force sensor was designed using by FEM(Finite Element Method), and fabricated using strain-gages. The characteristics experiment of the three-axis force sensor was carried out respectively. The test results indicated that the repeatability error and the non-linearity error of three-axis force sensor was less than 0.04% respectively. Therefore, the fabricated three-axis force sensor in the calf link can be used to measure the patient's calf force in the walking assist robot.

머시닝센터 장착형 연마 로봇의 성능 향상에 관한 연구 (A study on the improvement of performance of polishing robot attached to machining center)

  • 조영길;이민철;전차수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1275-1278
    • /
    • 1997
  • Cutting process has been automated by progress of CNC and CAD/CAM, but polishing process has been depended on only experiential knowledge of expert. To automate the polishing pricess polishing robot with 2 degrees of freedom which is attached to a machining center with 3 degrees of freedom has been developed. this automatic polishing robot is able to keep the polishing tool normal on the curved surface of die to improve a performance of polishing. Polishing task for a curved surface die demands repetitive operation and high precision, but conventional control algorithm can not cope with the problem of disturbance such as a change of load. In this research, we develop robust controller using real time sliding mode algorithm. To obtain gain parameters of sliding model control input, the signal compression method is used to identify polishing robot system. To obtain an effect of 5 degrees of freedom motion, 5 axes NC data for polishing are divided into data of two types for 3 axis machining center and 2 axis polishing are divided into data of two types for 3 axis machining center and 2 axis polishing robot. To find an efficient polishing condition to obtain high quality, various experiments are carried out.

  • PDF

외력에 반응하는 인간형 로봇의 머리를 위한 6 축 힘/모멘트 센서 개발 (Development of 6-axis Force/moment Sensor for Humanoid Robot's Head Reacting to a External Force)

  • 김갑순
    • 한국정밀공학회지
    • /
    • 제26권12호
    • /
    • pp.78-84
    • /
    • 2009
  • When external force is applied to humanoid robot's head, humanoid robot's neck is rotated to prevent the damage of it. So, robot's neck have to perceive forces (Fx of x-direction, Fy of y-direction and Fz of z-direction) and moments (Mx of x-direction, My of y-direction and Mz of z-direction) using the attached 6-axis force/moment sensor. Thus, in this paper, 6-axis force/moment sensor was developed to sense the forces and moments applied to robot's head. The structure of 6-axis force/moment sensor was modeled newly, and it was designed using FEM software (ANSYS) and manufactured by attaching straingages on the sensing element, finally, the characteristic test of the sensor was carried out. As a result, it is confirmed that interference error is less than 3%. And, it is thought that the sensor can be used to measure the forces and the moments for humanoid robot's head.

인간형 로봇의 지능형 발의 발가락 및 뒤꿈치 힘센서 개발 (Development of Force Sensors of Toes and Heel for Humanoid Robot's Intelligent Foot)

  • 김갑순
    • 한국정밀공학회지
    • /
    • 제27권10호
    • /
    • pp.61-68
    • /
    • 2010
  • In order to let the humanoid robot walk on the uneven terrains, the robot's foot should have the similar structure and function as human's. The intelligent foot should be made up of toes and heel. When it walks on the uneven terrains, the foot's sole senses the force and adjusts foot's position before robot losing his balance. In this paper, the force sensors of robot's intelligent foot for having the similar structure and function like human are developed. The heel 3-axis force/moment sensor and toe force sensors for humanoid robot's intelligent foot is developed, and the characteristic tests of them are carried out. As a result of characteristic test, the interference error of the heel 3-axis force/moment sensor is less than 2.2%. It is thought that the developed force sensors could be used to measure the reaction forces which is applied the toes and the heel of a humanoid robot.

3축 힘 센서가 적용된 손목 굽힘 재활로봇 개발 (Development of a Wrist Bending Rehabilitation Robot with a Three-axis Force Sensor)

  • 김갑순
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.27-34
    • /
    • 2016
  • This paper describes the development of a rehabilitation robot that can provide wrist bending exercise to a severe stroke patient staying in a bed ward or at home. The developed rehabilitation robot has a three-axis force sensor which detects three directional force Fx, Fy, and Fz. The sensor measures a bending force (Fz) exerted on the wrist and the signal force (Fx and Fy) which can be used for the safety purpose. The robot was designed for severe stroke patients in bed, and the robot program was developed to perform a wrist bending rehabilitation exercise. In our tests including a nine-day experimental exercise, the developed force sensor-based robot operated effectively and safely.

로봇 손가락용 소형 6축 힘/모멘트센서 개발 (Development of a small 6-axis force/moment sensor for robot's finger)

  • 김갑순;이상호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.490-493
    • /
    • 2003
  • This paper describes the development of a small 6-axis force/moment sensor for robot's finger, which measures forces Fx. Fy, Fz, and moments Mx, My, Mz simultaneously. In order to safely grasp an unknown object using the robot's gripper, and accurately perceive the position of it in the gripper, it should measure the force in the gripping direction, the force in the gravity direction and the moments each direction. and perform the control using the measured forces and moments. Thus, the robot's gripper should be composed of 6-axis force/moment sensor that can measure forces Fx, Fy, Fz, and moments Mx, My. Mz simultaneously. In this paper, the small 6-axis force/moment sensor for measuring forces Fx, Fy, Fz, and moments Mx, My, Mz simultaneously was newly modeled using several parallel-plate beams, designed, and fabricated. The characteristic test of made sensor was performed, and the result shows that interference errors or the developed sensor are less than 3%. Thus, the developed small 6-axis force/moment sensor may be used for robot's gripper.

  • PDF

로봇 손가락용 소형 6축 힘/모멘트센서 개발 (Development of a Small 6-axis Force/Moment Sensor for Robot′s Finger)

  • 김갑순
    • 한국정밀공학회지
    • /
    • 제21권3호
    • /
    • pp.51-58
    • /
    • 2004
  • This paper describes the development of a small 6-axis force/moment sensor for robot's finger, which measures farces Fx, Fy, Fz, and moments Mx, My, Mz simultaneously. In order to safely grasp an unknown object using the robot's gripper, and accurately perceive the position of it in the gripper, it should measure the force in the gripping direction, the force in the gravity direction and the moments each direction, and perform the force control using the measured forces and moments. Also, it should detect the moments Mx (x-direction moment), My and Mz to accurately perceive the position of the object in the grippers. Thus, the robot's gripper should be composed of 6-axis force/moment sensor that can measure forces Fx, Fy, Fz, and moments Mx, My, Mz simultaneously. In this paper, the small 6-axis force/moment sensor for measuring forces Fx, Fy, Fz, and moments Mx, My, Mz simultaneously was newly modeled using several parallel-plate beams, designed, and fabricated. The characteristic test for the developed sensor was performed, and the result shows that intereference errors of the developed sensor are less than 4.23%. Thus, the developed small 6-axis force/moment sensor may be used a robot's gripper.