• Title/Summary/Keyword: 3 section control

Search Result 654, Processing Time 0.025 seconds

Modificaion and Performance Test for improving ability of Supersonic/Hypersonic Wind Tunnel(MAF) (초음속/극초음속 풍동(MAF)의 성능 향상을 위한 개조 및 검증)

  • Choi, Won-Hyeok;Seo, Dong-Su;Lee, Jae-Woo;Byun, Yung-Hwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.717-722
    • /
    • 2010
  • Supersonic/Hypersonic wind tunnel is a facility which is intended to test and to observe the physical phenomena around a model by creating supersonic flow in the test section. In designing an airplane, the wind tunnel test is demanded to analyzing aerodynamic characteristics of the model without making a prototype. In this research, the model aerodynamic facility(MAF) is modified for the purpose of increasing running time and its functionality. New pneumatic valves for remote control was installed for safety requirement, and new air tanks was installed on MAF as well. A pipe system is also modified to use those new valves and tanks, and the ceiling and side glasses of the test section are switched to ones with the larger surface area. After the MAF modification, a test is performed at Mach 2, 3 and 4. In this test, shadow graph technique, one of the flow visualization methods, is used to visualize supersonic flow field. The pressure in the settling chamber and working section at Mach 2, 3 and 4 was measured in each case. As a result, the possible model size and running time are obtained.

  • PDF

Study on Effect of Pressure-Controlled Injection System in Dental Local Anesthesia (치과용 국소마취 주사시 압력조절형 주사장치 사용의 효과에 대한 연구)

  • Yun, Pil-Young;Kim, Young-Kyun
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.6 no.2 s.11
    • /
    • pp.98-102
    • /
    • 2006
  • The purpose of this study was to evaluate the difference on pain intensity and discomfort between pressure-controlled injection system and conventional syringe injection technique from the patients undergoing oral and maxillofacial surgery. In a prospective, randomized, case-controlled study, 60 patients were divided into two groups (n=30 in each). In experimental group, pressure-controlled injection system was applied. In control group, conventional syringe injection system was applied. Pain rating score (PRS) and visual analogue scale (VAS) were assessed. The average of VAS in experimental group ($16.67{\pm}15.07$) was smaller than that of control group ($25.63{\pm}22.21$), though there were no significant differences (P=0.072). In PRS, fifteen patients (50.0%) of experimental group answered that they experienced mild pain. However sixteen patients (53.3%) of control group answered that they experienced intermediate pain. From the results, pressure-controlled injection system may be an effective method to reduce pain during the dental local anesthetic procedure.

  • PDF

Geochemical Investigation of Fluoride Migration in the Soil Affected by an Accidental Hydrofluoric Acid Leakage (불산 누출사고 지역 토양수의 지구화학적 특성을 통한 불소 거동 및 확산 잠재성 연구)

  • Kwon, Eunhye;Lee, Hyun A;Kim, Doyoung;Lee, Junseok;Lee, Sanghoon;Yoon, Hye-On
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.3
    • /
    • pp.65-73
    • /
    • 2015
  • The hydrofluoric acid (HF) leakage accident occurred on September 2012 in Gumi, Korea affected the surrounding soils and plants. In this study, we investigated fluoride migration in Gumi area through geochemical properties of soil-liquid phase (pore water F and water-soluble F). The concentrations of porewater F and water-soluble F were obtained from N.D (Not detected) to 9.79 mg/L and from 0.001 to 21.4 mg/L, respectively. F in pore water seemed to be affected by artificial and natural origin, and PHREEQC results implied that fluorite is F control factor. F concentrations of soil and soil-liquid phase did not exceed concern level of regulatory criteria and showed similar trends compared by previous studies. Therefore, F contents remained in the soil and soil-liquid phase were considered to be not affected by HF leakage accident.

Top-executives Compensation: The Role of Corporate Ownership Structure in Japan

  • Mazumder, Mohammed Mehadi Masud
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.4 no.3
    • /
    • pp.35-43
    • /
    • 2017
  • This paper explores the impact of corporate control, measured by ownership structure, on top-executives' compensation in Japan. According to agency theory, the pay-performance link is expected to be affected by the firm's ownership structure. Using a sample of 4,411 firm-year observations (401 firms for the 11-years period from 2001 to 2011) for Japanese non-financial firms publicly traded on the first section and second section of the Tokyo Stock Exchange (TSE), this study demonstrates that institutional ownership (both financial and corporate) is negatively related to the level of executives' compensation. Such finding is in line with efficient monitoring hypothesis which claims that the presence of institutional shareholders provides direct monitoring over managers, limits managerial self-dealing and curves the increase in top-executives pay. On the other hand, the results also show that managerial ownership is positively related to their compensation which supports managerial power theory hypothesis, i.e. management-controlled firms are more likely to extract more compensation from the business than other firms. Overall, this study confirms that corporate control has significant impact on cash compensation paid to Japanese top-executives after controlling the conventional pay-performance relationship.

Development of Automatic Sorting System for Green pepper Using Machine Vision (기계시각에 의한 풋고추 자동 선별시스템 개발)

  • Cho, N.H.;Chang, D.I.;Lee, S.H.;Hwang, H.;Lee, Y.H.;Park, J.R.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.6 s.119
    • /
    • pp.514-523
    • /
    • 2006
  • Production of green pepper has been increased due to customer's preference and a projected ten-year boom in the industry in Korea. This study was carried out to develop an automatic grading and sorting system for green pepper using machine vision. The system consisted of a feeding mechanism, segregation section, an image inspection chamber, image processing section, system control section, grading section, and discharging section. Green peppers were separated and transported using a bowl feeder with a vibrator and a belt conveyor, respectively. Images were taken using color CCD cameras and a color frame grabber. An on-line grading algorithm was developed using Visual C/C++. The green peppers could be graded into four classes by activating air nozzles located at the discharging section. Length and curvature of each green pepper were measured while removing a stem of it. The first derivative of thickness profile was used to remove a stem area of segmented image of the pepper. While pepper is moving at 0.45 m/s, the accuracy of grading sorting for large, medium and small pepper are 86.0%, 81.3% and 90.6% respectively. Sorting performance was 121 kg/hour, and about five times better than manual sorting. The developed system was also economically feasible to grade and sort green peppers showing the cost about 40% lower than that of manual operations.

A Study on the Comparative Analysis and Improvement of Indoor Environmental Factor in Green Building Rating Systems (국내외 친환경건축물 인증제도 실내 환경 관련 부문 비교분석 및 개선안 연구)

  • Joh Hahn
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.4 s.57
    • /
    • pp.21-28
    • /
    • 2006
  • To promote environmentally responsible architectural practice, many nations have established their own green building rating system. Among other criteria, recently the indoor environmental quality section has been paid great attention due to Sick Building Syndrome, as this believed to caused by polluted indoor environment. In this context, indoor environmental quality is one of very important sections of each green building rating system and closely related to the very happiness of building users. The goal of this research is to compare and analyze the indoor environmental sections of three green building rating systems, GBCC, LEED v2.1, and BREEAM Office 2005, and find a direction for the improvement of GBCC. First, the three rating systems are analyzed in general to compare the importance of indoor environmental factors in each system. Second, the indoor environmental factors are reclassified within related sub-categories for the comparable analysis. Finally, based upon the comparable analysis, directions for the improvement of GBCC are as follows: 1. GBCC's h4r Environment Section needs to clarify its VOCs criteria based upon types of finish materials. 2. Sound Environment Section's noise control criteria needs to be revised based upon types of building usages and application method. 3. An indoor lighting related section needs to be included in GBCC, as even though light is the one of the most important factors in indoor environment, it has not been included in GBCC yet. 4. The sub-section of Confortable Indoor Environment Section related to the resting space and the universal accessibility are not in accord with the goal of green building rating system. These items need to be dealt within general building codes. 5. The rating evaluation structure and process need to be streamlined.

Clinical Practice of COVID-19 and Infection Control by Dental Hygiene Students in Jeju Province (제주지역 치위생과 학생의 COVID-19와 감염관리 임상실습 수행 실태)

  • Baek, Soo-Jeong;Woo, Jaeman;Kim, Sung-Joon
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.2
    • /
    • pp.370-378
    • /
    • 2022
  • The purpose of this study was to investigate the factors affecting infection control practice by dental hygienist students in Jeju during clinical training amidst the COVID-19 pandemic. Online survey was conducted on 112 students and the results were statistically analyzed with frequency analysis, Student's T-test, one-way ANOVA, and regression analysis using SPSS 20.0. In the 'awareness and practice of infection control by year in college' section, 2nd year students scored significantly higher in 'cleaning and surface disinfection,' 'medical waste disposal,' and 'COVID-19 preventive measure' compared to 3rd year students. In the 'type of training institution' section, hospital setting scored significantly higher in 'cleaning and surface disinfection,' 'instrument disinfection and sterilization,' 'personal and patient protection,' and 'COVID-19 preventive measure' compared to dental clinic setting. In the 'location of institution' section, Seoul metropolitan region scored higher in 'medical waste disposal' compared to Jeju region. According to regression analysis, year in college (2nd year), type of training institution (hospital setting), location of training institution (Seoul metropolitan region), and difficulty using protective gear (no difficulty) were associated with better COVID-19 preventive measure This first study in Jeju provides an insight on the awareness and practice of infection control measures by dental hygienist students in Jeju during clinical training. Further investigation for improvement of clinical training manual is warranted.

The Study of If Frequency Synthesizer IC Design for Digital Cellular Phone (디지털 이동통신단말기용 IF 주파수합성기 IC개발에 관한 연구)

  • 이규복;정덕진
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.8 no.1
    • /
    • pp.19-25
    • /
    • 2001
  • In this paper, the design and simulation results of IF frequency synthesizer section has been described. We has been used 0.8 $\mu\textrm{m}$ BiCMOS device and library of the AMS. IF frequency synthesizer section has been contained IF VCO, Phase Detector, Divide_by_8, Charge Pump and Loop Filter. IF frequency synthesizer has been shown operating voltage of 2.7~3.6 V, control voltage of 0.5~2.7 V and supply current of 11 mA. The measured results have been showed good agreement with the simulation results about supply current.

  • PDF

Optimal damping ratio of TLCDs

  • Chen, Yung-Hsiang;Chao, Chen-Chi
    • Structural Engineering and Mechanics
    • /
    • v.9 no.3
    • /
    • pp.227-240
    • /
    • 2000
  • The study of the optimal damping ratio of a tuned liquid-column damper (or TLCD) attached to a single-degree-of-freedom system is presented. The tuned liquid-column damper is composed of two vertical columns connected by a horizontal section in the bottom and partially filled with water. The ratio of the length of the horizontal section to the effective wetted length of a TLCD considered as another important parameter is also presented for investigation. A simple pendulum-like model test is conducted to simulate a long-period motion in order to prove the effectiveness of TLCD for vibrational control. Comparisons of the experimental and analytic results of the TLCD, TLD (tuned-liquid damper), and TMD (tuned-mass damper) are included for discussion.

Study on visualization of vortex flow on hydrofoils (수중익에서 발생하는 보텍스 유동 가시화 연구)

  • Hong, Ji-Woo;Ahn, Byoung-Kwon
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.2
    • /
    • pp.48-55
    • /
    • 2021
  • In order to design a propeller with high efficiency and excellent cavitation performance, theoretical and experimental studies on the cavitation and noise characteristics according to the blade section shape are essential. In general, sheet cavitation, bubble cavitation, and cloud cavitation are the main causes of hull vibration and propeller surface erosion. However vortex cavitation, which has the greatest influence on the noise level because the fastest CIS in ship propeller, has been researched for a long time and studies have been conducted recently to control it. In this experiment, the development process of cavitation was measured by using three dimensional wings with two different wing section and wing tip shapes, and the noise level at that time was evaluated. In addition, we evaluated the relationship between cavitation inception and hydrodynamic force using three component load cell and we measured the velocity field of wing wake using LDV.