• Title/Summary/Keyword: 3 phase

Search Result 21,048, Processing Time 0.045 seconds

Single-phase Active Power Filter Based on Rotating Reference Frame Method for Harmonics Compensation

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.94-100
    • /
    • 2008
  • This paper presents a new control method of single-phase active power filter (APF) for the compensation of harmonic current components in nonlinear loads. To facilitate the possibility of complex calculation for harmonic current detection of the single phase, a single-phase system that has two phases was constructed by including an imaginary second-phase giving time delay to the load current. The imaginary phase, which lagged the load current T/4 (Here T is the fundamental cycle) is used in the conventional method. But in this proposed method, the new signal as the second phase is delayed by the filter. Because this control method is applied to a single-phase system, an instantaneous calculation was developed by using the rotating reference frames synchronized to source-frequency rather than by applying instantaneous reactive power theory that uses the conventional fixed reference frames. The control scheme of single-phase APF for the current source with R-L loads is applied to a laboratory prototype to verify the proposed control method.

The Kinematical Analysis of Straddle Jump to Push up Motion on Sports Aerobics (스포츠 에어로빅스 Straddle Jump to Push up 동작의 운동학적 분석)

  • Kim, Cha-Nam
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.77-90
    • /
    • 2002
  • This study serves the purpose of understanding about correct jump and landing motion through Kinematical Analysis of Straddle Jump to Push up Motion at target by four elite sports aerobics athletes have more than four years career. And further more that make good assistance for coaches effective guidance through an offer basic data and correct diagnosis, evaluate of motions. It was picture-taked by two-video camera for Straddle Jump to Push up Motions. Camera speeds are 60 frame/sec. There are Kinematical Variation elements for analysis, the displacement of COG, each angle displacement left/right of shoulder-joint, each angle displacement left/right of knee-joint and each speed left/right of tip of the toes. Every each person accomplished severaly 3 times and we have acquired this conclusion. The conclusions were as follows; 1. Each situation for displacement of COG showed low height of COG by phase 1, 4, 5(79.05${\pm}9.07,\;46.41{\pm}3.65,\;18.66{\pm}0.54cm$) and It showed high height of COG by phase 2, 3($120.80{\pm}6.13,\;148.12{\pm}9.19cm$). 2. Each displacement left, right of shoulder-joint flexion by phase 1($91.07{\pm}8.30,\;90.77{\pm}5.72$deg/sec)and It showed maximal extension angles by phase 2($102.48{\pm}10.00,\;102.39{\pm}10.51$deg/sec). in part of phase 3, left of shoulder-joint angle($94.43{\pm}4.12$deg/sec) showed flexion phase 1, the other right shoulder-joint angle(88.38${\pm}$4.98deg/sec) showed more a little lower than phase 1, in last phase that showed most low by phase 4($70.58{\pm}13.72,\;54.24{\pm}11.58$deg/sec). 3. Each displacement left, right of hip joint showed maximal extent conditions by phase 2, 3($160.35{\pm}22.68,\;1534.77{\pm}5.40$deg/sec, $150.04{\pm}12.79,\;145.54{\pm}13.00$deg/sec) beside, ankle-joint showed minimal angle by phase 1, 4($93.59{\pm}18.92,\;85.37{\pm}13.23$deg/sec, $66.60{\pm}15.77,\;80.60{\pm}16.57$deg/sec). 4. Each displacement left, right of hip joint showed maximal extent conditions by phase 2($157.15{\pm}9.13,\;163.52{\pm}8.18$deg/sec), and right of hip joint showed minimal angle by phase 3($110.87{\pm}13.81,\;77.53{\pm}8.95$deg/sec) It showed alike condition of low angle by phase 1, 4($91.04{\pm}2.31,\;96.26{\pm}2.20$deg/sec). 5. Each displacement left, right of knee-joint showed maximal extent conditions by phase 1, 3, 4($173.46{\pm}2.95,\;171.51{\pm}5.44$deg/sec, $172.24{\pm}4.49,\;171.26{\pm}0.65$deg/sec, $162.78{\pm}2.13,\;164.10{\pm}5.97$deg/sec) but It showed flexion only left of knee-joint by phase 2($164.45{\pm}7.51,\;159.38{\pm}3.48$deg/sec). 6. Each speed left, right of the tip of the toes showed most fastest when someone jumped with lift up leges by phase 1, 2($321.32{\pm}67.91,\;316.90{\pm}41.97$cm/sec, $410.06{\pm}153.06,\;399.77{\pm}189.34$cm/sec), It showed more less speed than phase 1,2 by phase 3($169.74{\pm}67.17,\;150.00{\pm}63.80$cm/sec) and It showed most slow speed than phase 1,2,3 by phase 4($87.22{\pm}34.90,\;85.72{\pm}52.23$cm/sec).

Separation and Recovery of Heavy Metal Ion using Liquid Membrane (액체막법에 의한 중금속이온의 분리 및 회수)

  • Jo, Mun Hwan;Jeong, Hak Jin;Lee, Sang In;Kim, Jin Ho;Kim, Si Jung
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.2
    • /
    • pp.122-128
    • /
    • 1994
  • Macrocyclic ligand has been known to selectively bind with metal ions so that ability applied for the transport of metal ions across the emulsion liquid membrane in this study. The metal ions are transproted from the source phase to the receiving phase by the carrier of the organic phase. Several factors involved in the transport of metal ions acrose the emulsion membrane we reported here and these factors provided the informations for the selective seperation of some metal ion. Stability constants for cation-macrocyclic ligand and metal ion-anion receiving phase interaction are examined as parameters for the prediction of metal ion transport selectivities. $Pb^{2+}$ was transported higher rates than the other metal ions in the mixture solution. The interaction of metal ion to anion in receiving phase is important. $S_2O_3^{2-}$- in replacement of $NO_3^-$ in the receiving phase enhances the transport of $Pb^{2-}$since $Pb^{2-}-S_2O_3^{2-}$interaction is greater than $Pb^{2+}-NO_3^-$ interaction.

  • PDF

Effect of Heat and Moisture on the Phase Transition in Dimethylammonium-Facilitated CsPbI3 Perovskite (다이메틸암모늄 유도 CsPbI3 페로브스카이트 상의 상전이 거동에 대한 열과 수분의 영향)

  • Sohyun Kang;Seungmin Lee;Jun Hong Noh
    • Korean Journal of Materials Research
    • /
    • v.33 no.8
    • /
    • pp.344-351
    • /
    • 2023
  • Cesium lead iodide (CsPbI3) with a bandgap of ~1.7 eV is an attractive material for use as a wide-gap perovskite in tandem perovskite solar cells due to its single halide component, which is capable of inhibiting halide segregation. However, phase transition into a photo inactive δ-CsPbI3 at room temperature significantly hinders performance and stability. Thus, maintaining the photo-active phase is a key challenge because it determines the reliability of the tandem device. The dimethylammonium (DMA)-facilitated CsPbI3, widely used to fabricate CsPbI3, exhibits different phase transition behaviors than pure CsPbI3. Here, we experimentally investigated the phase behavior of DMA-facilitated CsPbI3 when exposed to external factors, such as heat and moisture. In DMA-facilitated CsPbI3 films, the phase transition involving degradation was observed to begin at a temperature of 150 ℃ and a relative humidity of 65 %, which is presumed to be related to the sublimation of DMA. Forming a closed system to inhibit the sublimation of DMA significantly improved the phase transition under the same conditions. These results indicate that management of DMA is a crucial factor in maintaining the photo-active phase and implies that when employing DMA designs are necessary to ensure phase stability in DMA-facilitated CsPbI3 devices.

Analysis of Reduction Effect of Three Harmonic Currents by Zigzag Wiring of Single Phase Transformer (단상 변압기 지그재그 결선에 의한 3고조파 전류 저감 효과 분석)

  • Kim, Jong-Gyeum;Kim, Ji-Myeong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.3
    • /
    • pp.99-104
    • /
    • 2017
  • The three-phase four-wire power distribution system can be used to supply power to single-phase and three-phase loads at the same time. There are linear loads and nonlinear loads as single-phase loads connected to each phase. The nonlinear load generates a harmonic current during the power energy conversion process. In particular, the single-phase nonlinear load has a higher proportion of generation of the third harmonic current than the harmonics of the other orders. In a three-phase four-wire system, the third harmonic current flows through the neutral wire to the power supply side, affecting the power supply side and the line. Furthermore, the magnitude of the current flowing in the neutral line can be higher than the current flowing in the individual phase. If the neutral current is higher than the phase current, the breaker may be blocked. Therefore, it is necessary to reduce the amount of current flowing in the neutral line by harmonics. There is a method of zigzag connecting a single phase transformer by a method of reducing 3 harmonic current. In this study, the method of reducing the magnitude of the three harmonic currents flowing through the zigzag wire by comparing the polarity and the negative polarity characteristics of the single phase transformer was compared through measurement and simulation.

Output Waveform Improvement of Double-Connected 3-Phase Voltage Source Inverter by Single-Phase Inverter (단상 인버터의 동작에 의한 이중접속 3상 전압원 인버터의 출력파형 개선)

  • 최세완
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.330-334
    • /
    • 2000
  • This paper proposes a new double-connected 3-phase voltage source inverter with improved output voltage waveform. An auxiliary single-phase inverter injects a ripple voltage into the double- connected inverter to convert 12-step operation to 36-step operation. The KVA rating of the output phase-shifting transformer is reduced by employing a harmonic canceling reactor. The whole rectifier-inverter system including the proposed technique is introduced and the experimental results are provided.

  • PDF

Domain Structure and Phase Transformation of (001) Pb(Mg1/3Nb2/3)O3-x%PbTiO3 Single Crystals ((001) Pb(Mg1/3Nb2/3)O3-x%PbTiO3 단결정의 도메인 구조 및 상전이)

  • Lee, Eun-Gu
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.3
    • /
    • pp.218-223
    • /
    • 2014
  • The domain structures, dielectric properties, and phase transformation of (001)-oriented $Pb(Mg_{1/3}Nb_{2/3})O_3-x%PbTiO_3$ (PMN-x%PT) crystals for x=20, 30, 35, and 40 mole% have been investigated. PMN-20%PT consists of polar nano-domains (PND) which do not self-assemble into macro-domain plates. PMN-30%PT consists of PNDs which begin to self-assemble into colonies along preferred {110} planes. PMN-35PT consists of miniature polar domains on the nm scale. PMN-40%PT consists of {001} oriented lamella domains on the mm scale that have internal nano-scale heterogeneities. The dielectric properties of poled (001) PMN-x%PT single crystals have been measured for orientations both parallel and perpendicular to the [001] poling direction. The results of the temperature dependence of the dielectric constant and mesh scans for the 30%PT sample demonstrate that the initial monoclinic phase changes to single domain tetragonal phase and to cubic phase with increasing temperature.

A Study on the Current & Load Unbalance Factor in using Linear & Nonlinear Load (선형 및 비선형 부하 사용시 전류 및 부하불평형률에 대한 연구)

  • Kim, Jong-Gyeum;Kim, Ji-Myeong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.8
    • /
    • pp.1291-1296
    • /
    • 2017
  • Single-phase and three-phase load can be used together in 3-phase 4-wire system. Single-phase and three-phase loads can be classified as linear loads without harmonics and nonlinear with harmonics. Single-phase linear loads are linear loads such as lamps and heat, and single-phase nonlinear loads are power converters such as rectifiers. It is recommended that the distribution of loads in the 3-phase, 4-wire distribution lines be evenly distributed within a certain range. However, harmonic currents generated in a nonlinear load flow on the neutral line and affect the phase current magnitude. The difference in the magnitude of the individual phase current due to the influence of the harmonic current present in the neutral line can produce a difference in current and load unbalance. In this study, current unbalance ratio and load unbalance ratio which can occur when a combination of linear and nonlinear loads are applied to 3-phase 4-wire distribution line are calculated.

A Study on the Analysis and Limitations of the Same Phase Identification Under 3-Phase Unbalanced Constant Current Loads (3상 불평형 정전류 부하 조건에서의 동 위상 판별에 대한 분석 및 한계에 관한 연구)

  • Byun, Hee-Jung;Shon, Su-Goog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.6
    • /
    • pp.38-46
    • /
    • 2012
  • In this paper, the necessity for the identification of the absolute phase value is introduced and analyzed for a particular conductor line of a 3-phase type distribution network and the recent methods are also introduced. For the determination of the exact phase value for a specific point in the line, as compared with the phase reference point, the measured phase value must be within a range of ${\pm}60[^{\circ}]$. However, the phase of a particular point can fluctuate depending on the line constant, transformer wiring method, line length, line amperage, etc. A theoretical formulation such as Simulink modeling and analysis for a distribution network are conducted for the identification of phase at a specific point in the line. In particular, through evaluating the effects of unbalanced current loads at the time of determination of the phase value, the limitations of the present method for the determination of phases is described.

Ozone Generation Synergy Effects of Three-Phase Voltage Apply Type Superposed Discharge Ozonizer (3상 전압인가형 중첩방전 오존발생기의 오존생성 상승효과)

  • Lee, Byeong-Jun;Lee, Sang-Geun;Song, Hyeon-Jik;Kim, Yeong-Hun;Park, Won-Ju;Lee, Gwang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.8
    • /
    • pp.468-476
    • /
    • 2000
  • Nowadays, ozone is mainly utilized for water treatment and home equipments. Although the demand for ozone is increasing, the ozone yield of silent discharge type ozonizer is low. Therefore, it is expected to improve the energy efficiency and ozone yield of an ozonizer. In this paper, a new ozone generation system is proposed. The 60[Hz] three-phase voltage is applied to three-phase superposed discharge type ozonizer(3PSDO) which has three electrodes(central, internal and external electrodes). There is no discharge pause time when three-phase voltage is applied due to 120-degree phase difference of applied voltage. The synergy effect of the three-phase superposed discharge type ozonizer is investigated by comparing with the three sort of single-phase discharge type ozonizer(1PDO). So, three-phase superposed discharge type ozonizer is able to obtain high ozone yield, and optimize discharge space, because this can increase the discharge power at low applied voltage.

  • PDF