• Title/Summary/Keyword: 3 Tesla

Search Result 206, Processing Time 0.025 seconds

Neuro-Anatomical Evaluation of Human Suitability for Rural and Urban Environment by Using fMRI (자연과 도시환경의 인체친화성에 대한 신경해부학적 평가: 기능적 자기공명영상법)

  • Kim, Gwang-Won;Song, Jin-Kyu;Jeong, Gwang-Woo
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.18-27
    • /
    • 2011
  • The purpose of this study was to identify different cerebral areas of the human brain associated with rural and urban picture stimulation using a 3.0 Tesla functional magnetic resonance imaging (fMRI) and further to investigate the human suitability for rural and urban environments. A total of 27 right-handed participants (mean age: $27.3{\pm}3.7$) underwent fMRI study on a 3.0T MR scanner. The brain activation patterns were induced by visual stimulation with each rural and urban sceneries. The participants were divided into two groups as 26 subjects favorable to rural scenery and 14 subjects unfavorable to urban scenery based on their filled-in questionnaire. The differences of the brain activation in response to two extreme types of pictures by the two sample t-test were characterized as follows: the activation areas observed in rural scenery over urban were the insula, middle frontal gyrus, precuneus, caudate nucleus, superior parietal gyrus, superior occipital gyrus, fusiform gyrus, and globus pallidus. In urban scenery over rural, the inferior frontal gyrus, parahippocampal gyrus, postcentral gyrus, superior temporal gyrus, amygdala, and posterior cingulate gyrus were activated. The fMRI patterns also clearly show that rural scenery elevated positive emotion such as happiness and comfort. On the contrary, urban scenery elevated negative emotion, resulting in activation of the amygdala which is the key region for the feelings of fear, anxiety and unpleasantness. This study evaluated differential cerebral areas of the human brain associated with rural and urban picture stimulation using a 3.0 Tesla fMRI. These findings will be useful as an objective evaluation guide to human suitability for ecological environments that are related to brain activation with joy, anger, sorrow and pleasure.

Effects of Temperature Change on the Current Injected MRI (전류 주입 자기공명영상에 온도 변화가 미치는 영향)

  • 이수열;강현수;우응제;조민형
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.3
    • /
    • pp.303-309
    • /
    • 2001
  • It is well known that the electrical impedance of biological tissues is very sensitive to their temperature. In this paper, we have analyzed the effects of temperature change on the phase of magnetic resonance images obtained with external current injection. It has been found that the local phase in the current injected magnetic resonance image can be changed noticeably when local temperature change appears at a part of the tissue. At the experiments with a 0.3 Tesla MRI system, we observed the local phase changes at the phantom images when the phantom temperature was varied between 25 -45$^{\circ}C$. We think that the current injection MRI technique can be used for in-vivo monitoring of the temperature inside biiological tissues if the relation between the local temperature and phase can be quantified.

  • PDF

Wireless Power Transmission using Electromagnetic Inductive Coupling and LC Resonant (자기유도방식과 LC공진을 이용한 무선전력전송기기)

  • Lee, Seung-Hwan;Kimm, Hyoen-Min;Kim, Hee-Je;Kim, Su-Weon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.3
    • /
    • pp.349-354
    • /
    • 2013
  • Wireless power transmission introduced by Tesla has instrumented by many scientists of the world. This technique first was utilized as wireless communications such as radio in long range transmission. And contactless transmission using inductive property was used on white goods. In 2007, MIT' lab introduced that new wireless power transmission by magnetic resonance which has about 50% efficiency and 2M transmission distances, it was a chance to refocus a new possibility of wireless power transmission. In this paper, using LC coupling compensate the short distances of contactless transmission, this simple method could transmit about 30cm distances. Using this approach, it can be solved the short transmission distances, a drawback of Electromagnetic inductive coupling method.

A design of actively shielded superconducting MRI magnet (능동차폐형 초전도 MRI 마그네트의 설계)

  • 진홍범;류강식;송준태
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.1
    • /
    • pp.24-29
    • /
    • 1996
  • Magnetic field theories for the design of highly homogeneous magnet are introduced and a nonlinear optimization method for the design of actively shielded superconducting magnet is presented. The presented design method can optimize both main coil and shielding coil simultaneously by setting constraints on stray field intensity at a specified distance from the magnet center. A 2-Tesla actively shielded superconducting magnet, with 90cm bore diameter, is designed using the presented method. The field homogeneity is 2ppm/30cm DSV and the 5 gauss stray field contour is within 4m axially and 3m radially from the magnet center. (author)., 7 refs., 6 figs., 3 tabs.

  • PDF

Comparison of Brain Activation Images Associated with Sexual Arousal Induced by Visual Stimulation and SP6 Acupuncture : fMRI at 3 Tesla (시각자극과 삼음교 자침으로 유발된 성적 흥분의 대뇌 활성화 영상의 비교 : 3 테슬라 기능적 자기공명영상법)

  • Choi, Nam-Gil;Han, Jae-Bok;Jang, Seong-Joo
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.183-194
    • /
    • 2009
  • Purpose : This study was performed not only to compare the brain activation regions associated with sexual arousal induced by visual stimulation and SP6 acupuncture, but also to evaluate its differential neuro-anatomical mechanism in healthy women using functional magnetic resonance imaging (fMRI) at 3 Tesla (T). Subjects and methods : A total of 21 healthy right-handed female volunteers (mean age 22 years, range 19 to 32) underwent fMRI on a 3T MR scanner. The stimulation paradigm for sexual arousal consisted of two alternating periods of rest and activation. It began with a 1-minute rest period, 3 minutes of stimulation with either of an erotic video film or SP6 acupuncture, followed by 1-minute rest. In addition, a comparative study on the brain activation patterns between an acupoint and a shampoint nearby GB37 was performed. The fMRI data were obtained from 20 slices parallel to the AC-PC line on an axial plane, giving a total of 2,000 images. The mean activation maps were constructed and analyzed by using the statistical parametric mapping (SPM99) software. Results : As comparison with the shampoint, the acupoint showed 5 times and 2 times higher activities in the neocortex and limbic system, respectively. Note that brain activation in response to stimulation with the shampoint was not observed in the regions including the HTHL in the diencephalon, GLO and AMYG in the basal ganglia, and SMG in the parietal lobe. In the comparative study of visual stimulation vs. SP6 acupuncture, the mean activation ratio of stimulus was not significantly different to each other in both the neocortex and the limbic system (p < 0.05). The mean activities induced by both stimuli were not significantly different in the neocortex, whereas the acupunctural stimulation showed higher activity in the limbic system (p < 0.05). Conclusions : This study compared the differential brain activation patterns and the neural mechanisms for sexual arousal, which were induced by visual stimulation and SP6 acupuncture by using 3T fMRI. These findings will be useful to understand the theory of traditional acupuncture and acupoint channel in scientific point of view.

  • PDF

Diffusion-weighted MR imaging findings of intracerebral hematoma (뇌실질내의 확산강조영상 소견)

  • 박창숙;최순섭;오종영;박병호;김기욱;남경진;이영일
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.21-27
    • /
    • 2002
  • Purpose : To evaluate diffusion-weighted imaging findings of intracerebral hematoma according to the time sequence. Materials and methods : Seventeen patients with intracerebral hematoma were studied. Diffusion weighted images using 1.5 tesla MRI machine were obtained with b-value of $1000{\;}sec/\textrm{mm}^2$. The patients were grouped as hyperacute stage(within 12 hours, 5 patients), acute stage(within 3 days, 4 patients), subacute stage(within 3 weeks, 4 patients), and chronic stage(after 3 weeks,4 patients). The signal intensities were analysed as bright, high, iso, low and dark at the central and peripheral portions of the hematoma in each stage, and compared with those of T2 and T1 weighted images. Results : The signal intensities of the central and peripheral portion of the intracerebral hematoma on diffusion-weighted images were high and dark in hyperacute stage, dark and high-bright in acute stage, and high-bright and dark in subacute and chronic stages. The patterns of signal change of hematoma on diffusion-weighted image according to the time sequence were similar to those on T2-weighted image, but changed early and prominently. Conclusion : The intracerebral hematoma on diffusion-weighted image showed unique central and peripheral signal intensity according to the time sequence. Central portions show high to bright signals in hyperacute, subacute and chronic stage, and dark signal in acute stage, and peripheral portions show dark signals in hyperacute, subacute and chronic stage, and high to bright signal in acute stage.

  • PDF

Study on the Correlation between the Change in SAR and Temperature of the Human Head by use Dental Implant on 3.0T Brain MRI : Using the XFDTD program (3.0T Brain MRI 검사 시 치아임플란트 시술 유무와 인체의 SAR, 체온 변화와의 상관관계에 관한 연구 : XFDTD 프로그램을 이용)

  • Choe, Dea-yeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.139-146
    • /
    • 2017
  • At the Brain MRI examination, RF Pulse are irradiated on the human head in order to acquire MR images. At this time, a considerable part of the irradiated RF Pulse energy is absorbed in our body and the temperature of the human head will rise depending on the degree of exposure, so it will affect the human head. Even if the same RF Pulse energy is given, if the metal is inserted in the human head, the conductivity of the human head is greatly increased by the metal, so the SAR value increases and the temperature also rises. Therefore, we started this research with the question as to whether there is difference between the change in SAR value and temperature displayed on the head of the human according to use or not of the dental implant. Experiments were using the XFDTD program on a 128 MHz RF Pulse frequency by a 3.0 tesla MRI. We can see that both are increasing that the average value of SAR and temperature that absorbed by the human head model used the dental implant. In addition, the average maximum SAR value and the maximum temperature rise in the brain part are shown below the international safety standard value but the influence can not be ignored because of the result may change according to the increase in the number of dental implant. And as future tasks. we need to the simulation of temperature rise and SAR due to an increase in the number of implants and volumes of teeth, dental implant material.

핵융합용 초전도선재의 크롬도금기술

  • Park, Pyeong-Ryeol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.11a
    • /
    • pp.32-32
    • /
    • 2012
  • 화석연료의 남용으로 지구 온난화가 심화되어 환경과 생태계변화가 가속화되고 있고, 급속한 산업의 발달과 인류 삶의 질 향상에 따른 에너지 수요가 급증하고 있는 실정에 있으며, 일본 후쿠시마 원전사태로 원자력 에너지의 위험성으로 지구 인류환경은 심각한 국면을 맞이 하고 있어 대체 에너지의 하나로 핵융합 에너지 필요성이 증대되고 있다. 핵융합 에너지 연구 개발은 우리나라에서 KSTAR가 1997년부터 건설하기 시작하여 지난 2007년에 완공되어 지금 운용 중에 있고, 국제적으로 미국, EU, 러시아, 중국, 한국, 일본 인도가 참여하는 ITER 국제 공동프로젝트가 2004년에 건설을 시작하여 프랑스 카다라쉬에 실증 플란트를 건설 중에 있다. 이러한 핵융합 반응을 위해서는 10e-7이상의 높은 진공과 1억$^{\circ}C$ 이상에서 중수소와 삼중수소가 반응하여 발생하는 플라즈마를 제어 할 필요가 있으며, 초고온의 핵융합 플라즈마를 가두고 가동시키기 위해서는 약 12Tesla이상의 고자장 마그넷이 필요하다. 현재 ITER 실증 플란트에 사용되는 고자장 마그넷은 TF (Toroidal Field)코일과 CS (Central Field)코일에 Nb3Sn 초전도선재가 핵심부품으로 사용되고 있으며 ITER프로젝트에서는 약 850톤의 Nb3Sn 초전도선재가 사용될 전망이다. 그 중에서 일본 25%, EU, 러시아와 한국이 각각 20%, 중국7%, 미국8% 할당되어 참여국 대부분은 초전도선재를 전략적으로 공급하고 있다. 초전도 선재의 크롬도금은 1~2 마이크로미터 이하의 균일하고 얇은 도금 두께와 밀착성이 우수한 품질이 요구된다. 일반적으로 크롬도금은 산업현장에서 컨베이어 벨트 방식으로 장식이나, 내식성 및 내마모성의 특성을 필요로 할 때 사용되고 있으나, 선재에 크롬도금을 릴투릴(Reel to Reel) 방식으로 적용되는 경우는 세계적으로 아주 드물다. 핵융합 마그넷의 CICC(Conduct In Cable Conduit)도체를 만들기 위해서는 초전도선재를 이용, 3(Sc 2+OFC 1)$^*3^*5^*5^*6$형태로 연선과 케이블링을 하게 되며, 초전도 선재를 연선하고 케이블링을 할 때 크롬 도금층이 박리될 가능성이 있어 크롬도금 방법과 프로세스를 특별히 고안할 필요가 있다. ITER핵융합로 마그넷의 TF코일은 높이 14m, 폭 9m 최대자장 12Tesla, 최대전류 68kA, CICC도체 직경이 40mm로서 그 초전도 조관/도체 내부에 0.82mm 직경의 Nb3Sn 초전도 선재가 약 1350가닥으로 연선과 케이블링으로 구성되어 있다. ITER 핵융합 마그넷용 초전도 선재의 크롬도금은 마그넷 권선 후 Nb3Sn 초전도물질을 형성하기 위해서 $650^{\circ}C$에서 500시간 열처리를 실시하며 열처리 시 초전도 선재의 소선들 사이에 발생할 수 있는 소착을 방지하고, 초전도 선재에서 발생하는 AC loss를 감소시키며, Quench시 발생되는 열을 쉽게 확산시킴으로써, 초전도 마그넷의 열적 안정성(Thermal Stability) 향상과 필요에 따라서 소선간 통전울 가능하게 한다. 고려제강의 자회사인 케이에이티는 크롬도금 밀착성이 우수하고 도금두께 0.1마이크로 미터 이내 제어가 가능한 얇고 균일한 도금품질을 개발하여 한국형 핵융합 실험로인 KSTAR에 65톤 전량 공급하였고, 크롬 도금된 무산소동 선재 32톤과 초전도 선재 93톤을 전량 ITER 프로젝트에 공급하고 있으며, 2013년도 상반기에는 공급을 마무리할 예정이다.

  • PDF

Imaging Assessment of Visceral Pleural Surface Invasion by Lung Cancer: Comparison of CT and Contrast-Enhanced Radial T1-Weighted Gradient Echo 3-Tesla MRI

  • Yu Zhang;Woocheol Kwon;Ho Yun Lee;Sung Min Ko;Sang-Ha Kim;Won-Yeon Lee;Suk Joong Yong;Soon-Hee Jung;Chun Sung Byun;JunHyeok Lee;Honglei Yang;Junhee Han;Jeanne B. Ackman
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.829-839
    • /
    • 2021
  • Objective: To compare the diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3-tesla (3T) magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of visceral pleural surface invasion (VPSI). Visceral pleural invasion by non-small-cell lung cancer (NSCLC) can be classified into two types: PL1 (without VPSI), invasion of the elastic layer of the visceral pleura without reaching the visceral pleural surface, and PL2 (with VPSI), full invasion of the visceral pleura. Materials and Methods: Thirty-three patients with pathologically confirmed VPSI by NSCLC were retrospectively reviewed. Multidetector CT and contrast-enhanced 3T MRI with a free-breathing radial three-dimensional fat-suppressed volumetric interpolated breath-hold examination (VIBE) pulse sequence were compared in terms of the length of contact, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. Supplemental evaluation of the tumor-pleura interface (smooth versus irregular) could only be performed with MRI (not discernible on CT). Results: At the tumor-pleura interface, radial VIBE MRI revealed a smooth margin in 20 of 21 patients without VPSI and an irregular margin in 10 of 12 patients with VPSI, yielding an accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and F-score for VPSI detection of 91%, 83%, 95%, 91%, 91%, and 87%, respectively. The McNemar test and receiver operating characteristics curve analysis revealed no significant differences between the diagnostic accuracies of CT and MRI for evaluating the contact length, angle of mass margin, or arch distance-to-maximum tumor diameter ratio as predictors of VPSI. Conclusion: The diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3T MRI and CT were equal in terms of the contact length, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. The advantage of MRI is its clear depiction of the tumor-pleura interface margin, facilitating VPSI detection.

Magnetization characteristics of melt-textured Y-Ba-Cu-O with BaCe$O_{3}$ addition (용융공정으로 제조한 Y-Ba-Cu-O/BaCe$O_{3}$ 초전도체의 자화특성)

  • Kim, Chan-Jung;Park, Hae-Ung;Kim, Gi-Baek;Hong, Gye-Won
    • Korean Journal of Materials Research
    • /
    • v.5 no.4
    • /
    • pp.433-444
    • /
    • 1995
  • BaCe$O_{3}$를 첨가하여 용융공정으로 제조한 단결정형 Y$Ba_{2}$$Cu_{3}$$O_{x}$(1-2-3) 초전도체의 온도에 대한 자화특성을 연구하였다. 고상반응법과 용융공정으로 0에서 30wt% BaCe$O_{3}$를 1-2-3 결정내에 미세 분산시켰다. 초전도체의 자화특성은 VSM(vibrating sample magnetometer)을 사용하여 77K, 60K, 40K와 20K, 2 Tesla 자장범위에서 측정하였다. BaCe$O_{3}$를 첨가하지 않은 겨우나 5wt% BaCe$O_{3}$를 첨가한 1-2-3 결정의 경우, 77K, 외부자장이 증가시 자화율 차이가 증가하는 비정상 자화특성이 관찰된다. 측정온도가 60K에서는 제2차 최대점이 나타나는 자장값이 고자장쪽으로 이동한다. 20K와 40K의 저온에서는 비정상자화특성이 2 T의 자장범위까지 관찰되지 않았다. 15wt%와 20wt% BaCe$O_{3}$첨가한 시편에서는 자장이 증가하면 자화율차이가 단순히 감소한다. Y-Ba-Cu-O의 flux pinning 기구를 BaCe$O_{3}$첨가에 의한 미세조직변화로 설명하였다.

  • PDF