• Title/Summary/Keyword: 3 Point bending test

Search Result 370, Processing Time 0.027 seconds

Evaluation of the Bending Behavior of RC beam by Using Color-based Image Processing Method (색상에 기반한 영상분석기법을 이용한 콘크리트 거더의 휨 거동 분석)

  • Woo, Tae-Ryeon;Jung, Chi-Young;Kim, In-Tae;Lee, Jong-Han;Cheung, Jin-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.4
    • /
    • pp.48-54
    • /
    • 2020
  • Cracks in reinforced concrete structures are the most common type of damage and are used as important analytical data to understand the fracture behavior characteristics of structures. Currently, there is a problem that most of the crack investigation relies on visual inspection, therefore many researchers have proposed image analysis techniques to improve the problem. In this study, we proposed a crack evaluation method to be applied at an indoor experimental level using image analysis method. The image analysis technique using color is for distinguishing a boundary surface between objects existing in an image, and is a method for separating similar colors into one region based on a predefined color. In this study, to improve the accuracy of image analysis, blue paint was applied to the concrete surface and bending experiments were performed. The image analysis method was able to measure the crack width with superior accuracy compared to the crack diameter, and at the same time, it was also possible to analyze the deflection of the beam. Both the crack and deformation were able to confirm the accuracy similar to the existing measurement method, and it was found that the image analysis method was very excellent in terms of applicability.

A Study on Wafer-Level 3D Integration Including Wafer Bonding using Low-k Polymeric Adhesive (저유전체 고분자 접착 물질을 이용한 웨이퍼 본딩을 포함하는 웨이퍼 레벨 3차원 집적회로 구현에 관한 연구)

  • Kwon, Yongchai;Seok, Jongwon;Lu, Jian-Qiang;Cale, Timothy;Gutmann, Ronald
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.466-472
    • /
    • 2007
  • A technology platform for wafer-level three-dimensional integration circuits (3D-ICs) is presented, and that uses wafer bonding with low-k polymeric adhesives and Cu damascene inter-wafer interconnects. In this work, one of such technical platforms is explained and characterized using a test vehicle of inter-wafer 3D via-chain structures. Electrical and mechanical characterizations of the structure are performed using continuously connected 3D via-chains. Evaluation results of the wafer bonding, which is a necessary process for stacking the wafers and uses low-k dielectrics as polymeric adhesive, are also presented through the wafer bonding between a glass wafer and a silicon wafer. After wafer bonding, three evaluations are conducted; (1) the fraction of bonded area is measured through the optical inspection, (2) the qualitative bond strength test to inspect the separation of the bonded wafers is taken by a razor blade, and (3) the quantitative bond strength is measured by a four point bending. To date, benzocyclobutene (BCB), $Flare^{TM}$, methylsilsesquioxane (MSSQ) and parylene-N were considered as bonding adhesives. Of the candidates, BCB and $Flare^{TM}$ were determined as adhesives after screening tests. By comparing BCB and $Flare^{TM}$, it was deduced that BCB is better as a baseline adhesive. It was because although wafer pairs bonded using $Flare^{TM}$ has a higher bond strength than those using BCB, wafer pairs bonded using BCB is still higher than that at the interface between Cu and porous low-k interlevel dielectrics (ILD), indicating almost 100% of bonded area routinely.

A COMPARATIVE STUDY OF THE PHYSICOCHEMICAL PROPER TIES AND BOND STRENGTH TO METAL BETWEEN THE REGULAR OPAQUE POWDER AND CORE POWDER (도재소부전장금관용 Opaque 분말과 도재전장관용 core 분말의 물리화학적 성질 및 금속과의 결합력에 대한 비교연구)

  • Lim, Jang-Seop;Chung, Chang-Mo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.1
    • /
    • pp.144-164
    • /
    • 1997
  • The purpose of this study were to investigate the chemical composition, mean particle size, linear thermal expansion coefficient and metal-bonding strength of the regular opaque powder and core powder. In this study, 4 types of ceramic powders, namely Duceram Jacket Opaque powder, Duceram Opaque powder, Vita Hi-Ceram powder, Vita VMK Paint On-88 powder were used. Chemical composition was evaluated by EDS(Energy Dispersive X-ray Spectrophotometer, Oxford QX-2000, England), particle size was measured by MALVERN Instruments(MALVERN Instruments SB. OC., U.S.A.. ad linear thermal expansion coefficient was measured by dilatometer(Motoyama, Japan). Bond strength was measured by the Universal tsting machine(Istron Co., Ltd., U.S.A.). The Results were as follows : 1. Through recognition of the relative difference in chemical composition between the core powder and the regular opaque powder, the difference in the proportion of $Al_2O_3$ in each type of material is demonstrated ; Duceram Jaket Opaque powder : 30.16%, Duceram Opaque powder : 16.60%, Vita Hi-Ceram : 63.64%, Vita VMK Paint-On 88 : 16.16%. 2. There was no significant difference in the proportion of metal-bonding materials between the core powder and the regular opaque powder. 3. In the regular opaque powder, alkaline materials were incoporated in order to increase the coefficient of thermal expansion. 4. In the particle size analysis, there was no significant difference in mean particle size or in the particle size distribution between the core powder and the regular opaque powder. 5. In the thermal expansion test for temperature range of $25-600^{\circ}C$, the regular opaque powder had higher coefficient of thermal expansion than that of core powder. 6. In the 4 point flexural bending test, there was no statistically significant difference in the mean bond strength between the core powder and the opaque powder among the Duceram products.

  • PDF

Influence of Oxidation Inhibitor on Carbon-Carbon Composites : 7. Studies on Work of Adhesion and Fracture Toughness of Carbon-Carbon Composites (산화억제제를 첨가한 탄소/탄소 복합재료의 물성에 관한 연구 : 7. 탄소/탄소 복합재료외 부착력과 파괴인성)

  • 박수진;서민강;이재락
    • Polymer(Korea)
    • /
    • v.25 no.3
    • /
    • pp.435-440
    • /
    • 2001
  • The objective of this study was to examine the effect of oxidation inhibitor contents on the work of adhesion, fracture toughness, and impact strength of the unidirectional carbon-carbon composites (C/C composites). The molybdenum disilicide ($MoSi_2$) used as an oxidation inhibitor was impregnated with phenolic resins to improve the anti-oxidation properties of the composites in different concentrations of 4, 12 and 20 wt%. Based on Wilhelmy equation, the work of adhesion of C/C composites was calculated by contact angle methods. Fracture toughness and impact strength were pressured by three-point bending test for the critical intensity factor ($K_IC$) and Izod test method, respectively. As a result, the composites made with $MoSi_2$ resulted in an increasing of both fracture toughness and impact strength. Especially, the composites made with 12 wt% $MoSi_2$ content showed the highest value of London dispersive component, $W_A\;^L$, in work of adhesion, resulting from improving the interfacial adhesion force among fibers, filler, and matrix in this system.

  • PDF

A COMPARATIVE STUDY BETWEEN DEGREE OF CONVERSION AND FLEXURAL STRENGTH OF COMPOSITE RESINS

  • Lee Seong-Hee;Pae Ahran;Kim Sung-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.333-342
    • /
    • 2006
  • Statement of problem. Although many studies have been carried out to investigate the correlation between the degree of conversion and the flexural strength of composite resins, there is minimal information in the literature attempting to compare degree of conversion, flexural strength and their correlation between restorative composite resins and flowable composite resins. Purpose. The purposes of this study were to measure the degree of conversion and flexural strength of composite resins with different rheological behavior and to correlate the two properties. Materials and methods. Four restorative (Vit-1-escence, Z-250, Tetric ceram, Esthet-X) and four flowable (Aeliteflo, Admiraflow, Permaflo, Revolution) light-curing composite resins were investigated. The degree of conversion(DC) was analyzed with Fourier transfer infra-red spectroscopy(FTIR) spectrum by a potassium bromide(KBr) pellet transmission method. The spectrum of the unpolymerized specimen had been measured before the specimen was irradiated for 60s with a visible light curing unit. The Poiymerized specimen was scanned for its in spectrum. The flexural strength(FS) was measured with 3-point bending test according to ISO 4049 after storage in water at $37^{\circ}C$ for 24 hours. The data were statistically analyzed by an independent sample t-test and one-way ANOVA at the significance level of 0.05. The dependence of flexural strength on the degree of conversion was also analyzed by regression analysis. Results. Mean DC and FS values ranged from 43% to 61% and from 84.7MPa to 156.7MPa respectively. DC values of the flowable composite resins were significantly higher than those of restorative composite resins (P < 0.05). The FS values of restorative composite resins were greater than those of flowable composite resins. No statistically significant correlation was observed between the DC and the FS tested in any of the composites. The dependence of FS on DC in restorative or flowable composite resins was not significant. Conclusion. It can be concluded that radical polymerization of the organic matrix is not a major factor in determining flexural strength of the commercially available composite resins.

Fracture Properties of High Strength Concrete Disk with Center-Crack (중앙에 노치가 있는 고강도 콘크리트 디스크의 파괴특성)

  • 진치섭;김희성;박현재;김민철
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.2
    • /
    • pp.161-167
    • /
    • 2001
  • It is difficult to obtain accurate fracture toughness values using three point bending test(TPB) proposed by RILEM committees because the shape of load-deflection curve is irregular and final crack propagation occurs after some slow stable cracking. However, fracture toughness is easily obtained from crack initiation load in the disk test. In this paper, the fracture properties of high strength concrete disks with center-crack was investigated. For this purpose, the experimental results were compared with the results by finite element analysis(FEA). And the experimental fracture locus was compared with theoretical fracture locus. Also, the results of fracture properties for the degree of concrete strength are presented. It is concluded from this study that results from FEA with maximum stress theory were compared well with the results from experiment. And the degree of concrete strength was contributed to the crack initiation load and fracture toughness, but was not contributed to the failure angle. Also, The discrepancy of fracture locus between the maximum stress theory and the experiment for concrete is considered to depend upon a large energy requirement for inducing the mixed-mode and sliding mode fractures.

Physicochemical characterization of two bulk fill composites at different depths

  • Guillermo Grazioli ;Carlos Enrique Cuevas-Suarez ;Leina Nakanishi ;Alejandro Francia;Rafael Ratto de Moraes
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.3
    • /
    • pp.39.1-39.12
    • /
    • 2021
  • Objectives: This study analyzed the physical-chemical behavior of 2 bulk fill resin composites (BFCs; Filtek Bulk Fill [FBF], and Tetric-N-Ceram Bulk Fill [TBF]) used in 2- and 4-mm increments and compared them with a conventional resin composite (Filtek Z250). Materials and Methods: Flexural strength and elastic modulus were evaluated by using a 3-point bending test. Knoop hardness was measured at depth areas 0-1, 1-2, 2-3, and 3-4 mm. The translucency parameter was measured using an optical spectrophotometer. Real-time polymerization kinetics was analyzed using Fourier transform infrared spectroscopy. Results: Flexural strength was similar among the materials, while TBF showed lower elastic modulus (Z250: 6.6 ± 1.3, FBF: 6.4 ± 0.9, TBF: 4.3 ± 1.3). The hardness of Z250 was similar only between 0-1 mm and 1-2 mm. Both BFCs had similar hardness until 2-3 mm, and showed significant decreases at 3-4 mm (FBF: 33.45 ± 1.95 at 0-1 mm to 23.19 ± 4.32 at 3-4 mm, TBF: 23.17 ± 2.51 at 0-1 mm to 15.11 ± 1.94 at 3-4 mm). The BFCs showed higher translucency than Z250. The polymerization kinetics of all the materials were similar at 2-mm increments. At 4-mm, only TBF had a similar degree of conversion compared with 2 mm. Conclusions: The BFCs tested had similar performance compared to the conventional composite when used in up to 2-mm increments. When the increment was thicker, the BFCs were properly polymerized only up to 3 mm.

Fabrication of Molybdenum Alloys with Improved Fracture Toughness through the Dispersion of Lanthanum Oxide (란타넘 산화물의 분산을 통해 향상된 파괴인성을 갖는 몰리브데넘 합금의 제조)

  • Choi, Won June;Park, Chun Woong;Park, Jung Hyo;Kim, Young Do;Byun, Jongmin
    • Journal of Powder Materials
    • /
    • v.26 no.3
    • /
    • pp.208-213
    • /
    • 2019
  • In this study, lanthanum oxide ($La_2O_3$) dispersed molybdenum ($Mo-La_2O_3$) alloys are fabricated using lanthanum nitrate solution and nanosized Mo particles produced by hydrogen reduction of molybdenum oxide. The effect of $La_2O_3$ dispersion in a Mo matrix on the fracture toughness at room temperature is demonstrated through the formation behavior of $La_2O_3$ from the precursor and three-point bending test using a single-edge notched bend specimen. The relative density of the $Mo-0.3La_2O_3$ specimen sintered by pressureless sintering is approximately 99%, and $La_2O_3$ with a size of hundreds of nanometers is uniformly distributed in the Mo matrix. It is also confirmed that the fracture toughness is $19.46MPa{\cdot}m^{1/2}$, an improvement of approximately 40% over the fracture toughness of $13.50MPa{\cdot}m^{1/2}$ on a pure-Mo specimen without $La_2O_3$, and this difference in the fracture toughness occurs because of the changes in fracture mode of the Mo matrix caused by the dispersion of $La_2O_3$.

Effect of Grain Size and Predeformation on Shape Memory Ability and Transformation Temperature in Iron Base Fe-Mn-Si System Shape Memory Alloy (다결정질 Fe-Mn-Si계 형상기억합금의 형상기억합금과 변태점에 미치는 결정입도와 이전가공의 영향)

  • Choi, Chong Sool;Kim, Hyun Woo;Jin, Won;Shon, In Jin;Baek, Seung Han
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.3 no.1
    • /
    • pp.34-41
    • /
    • 1990
  • Effects of grain size and cold rolling degree on shape memory ability and transformation temperature were studied in Fe-35% Mn-6% Si shape memory alloy. Md point of the alloy was determined by variation of yield stress with test temperature. The Md point measured in this way was linearly increased with increasing grain size. Shape memory ability of the alloy was decreased with increasing grain size, showing a minimum value at around $63{\mu}m$, and then increased with increasing grain size. From this result, it was concluded that the shape memory ability in the grain size smaller than a critical value is controlled by amount of retained ${\gamma}$ and prior ${\varepsilon}$ phase, but that the shape memory ability in the grain size greater than the critical value is mainly dominated by grain boundary area in unit volume of parent phase. The shape memory ability was decreased with increasing deformation degree. This was because the ${\gamma}$ content being available for the formation of ${\varepsilon}$ martensite during bending was decreased with increasing deformation degree.

  • PDF

Assessment of effect of accelerated aging on interim fixed dental materials using digital technologies

  • Omar, Alageel;Omar, Alsadon;Haitham, Almansour;Abdullah, Alshehri;Fares, Alhabbad;Majed, Alsarani
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.360-368
    • /
    • 2022
  • PURPOSE. This study assessed the physical and mechanical properties of interim crown materials fabricated using various digital techniques after accelerated aging. MATERIALS AND METHODS. Three groups of interim dental restorative materials (N = 20) were tested. The first group (CO) was fabricated using a conventional manual method. The second group (ML) was prepared from prefabricated resin blocks for the milling method and cut into specimen sizes using a cutting disc. The third group (3D) was additively manufactured using a digital light-processing (DLP) 3D printer. Aging acceleration treatments using toothbrushing and thermocycling simulators were applied to half of the specimens corresponding to three years of usage in the oral environment (N = 10). Surface roughness (Ra), Vickers microhardness, 3-point bending, sorption, and solubility tests were performed. A 2-way analysis of variance (ANOVA) and Fisher's multiple comparison test were used to compare the results among the groups. RESULTS. The mean surface roughness (Ra) of the resin after accelerated aging was significantly higher in the CO and ML groups than that before aging, but not in the 3D group. All groups showed reduced hardness after accelerated aging. The flexural strength values were highest in the 3D group, followed by the ML and CO groups after accelerated aging. Accelerated aging significantly reduced water sorption in the ML group. CONCLUSION. According to the tested material and 3D printer type, both 3D-printed and milled interim restoration resins showed higher flexural strength and modulus, and lower surface roughness than those prepared by the conventional method after accelerated aging.