• Title/Summary/Keyword: 3차원초음파

Search Result 186, Processing Time 0.024 seconds

Development of a Ultrasound Probe for 3-D Ultrasonic Imaging (3차원 의료기기용 초음파진단기 프로브 개발)

  • Park, Jong-Soo;Kim, Seong-Rae;Nam, Yoon-Su
    • Journal of Industrial Technology
    • /
    • v.25 no.A
    • /
    • pp.87-93
    • /
    • 2005
  • Three-dimensional ultrasonic probes being applied to the medical imaging can be grouped into three depending on the scanning methods, which are a mechanical type system, a free-hand system, and 2D phased arrays system. A mechanical type scanner uses a mechanically driven transducer to acquire series of 2D plane images. By integrating these images, a 3-D medical image can be constructed. A motor driving mechanism is a conventional choice for mechanically driving a transducer assembly which picks the raw ultrasonic images up. In this paper we attempt to design a 3D ultrasonic probe which has a operating mechanism of s tilting 3-D scanning. The motion of a transducer assembly of the ultrasonic probe is analytically modelled. We propose a selection procedure for the diameter of a wire rope driving the transducer assembly and the size of torsional spring which gives an initial tension to wire ropes.

  • PDF

New Performance Evaluation Method of Focused Ultrasonic Transducers By Using Virtual 3D Graphic (가상 3D 그래픽을 이용한 집속형 초음파 탐촉자 성능평가 방법)

  • Lee, Sun-Heum;Choi, Kwan-Sun;Kim, Dong-Sik
    • The KIPS Transactions:PartB
    • /
    • v.14B no.6
    • /
    • pp.407-412
    • /
    • 2007
  • The performance of ultrasonic testing systems for industrial or medical purpose largely depends on the performance of ultrasonic transducers. Generally, the information about an ultrasonic transducer performance characteristics are expressed by the ultrasonic R/F signal back from a reflector and its frequency characteristics in the data sheet provided by manufacturers. In case of focused ultrasonic transducers, the two pieces of information can, however, hardly assure that the focused ultrasonic transducer would produce well-focused C-scan images. Therefore, we propose the measured size of focal spot and the reconstructed shape of effective focal zone in the focused sound field as novel measures for the performance evaluation of the focused ultrasonic transducers. The process of getting the both measures of the transducers is conducted by the implemented software including sound field scanning and virtual 3D reconstruction functions which requires the echo of a point reflector. The proposed method could, otherwise impossible in the existing method, effectively and simply distinguish superior ones among many transducers made in the same specification and be also used to detect the performance degradation due to the aging of the transducers. Eventually, the quality of performance of the ultrasonic testing systems for industrial or medical purpose is secured.

3-D Underwater Object Recognition Using PZT-Epoxy 3-3 Type Composite Ultrasonic Transducers (PZT-에폭시 3-3형 복합압전체 초음파 트랜스듀서를 사용한 3차원 수중 물체인식)

  • Cho, Hyun-Chul;Heo, Jin;SaGong, Geon
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.286-294
    • /
    • 2001
  • In this study, 3-D underwater object recognition using the self-made 3-3 type composite ultrasonic transducer and modified SOFM(Self Organizing Feature Map) neural network are investigated. Properties of the self-made 3-3 type composite specimens are satisfied considerably with requirements as an underwater ultrasonic transducer's materials. 3-D underwater all object's recognition rates obtained from both the training data and testing data in different objects, such as a rectangular block, regular triangular block, square block and cylinderical block, were 100% and 94.0%, respectively. All object's recognition rates are obtained by utilizing the self-made 3-3 type composite transducer and SOFM neural network. From the object recognition rates, it could be seen that an ultrasonic transducer fabricated with the self-made 3-3 type composite resonator will be able to have application for the underwater object recognition.

  • PDF

Functional beamforming for high-resolution ultrasound imaging in the air with random sparse array transducer (고해상도 공기중 초음파 영상을 위한 기능성 빔형성법 적용)

  • Choon-Su Park
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.361-367
    • /
    • 2024
  • Ultrasound in the air is widely used in industry as a measurement technique to prevent abnormalities in the machinery. Recently, the use of airborne ultrasound imaging techniques, which can find the location of abnormalities using an array transducers, is increasing. A beamforming method that uses the phase difference for each sensor is used to visualize the location of the ultrasonic sound source. We exploit a random sparse ultrasonic array and obtain beamforming power distribution on the source in a certain distance away from the array. Conventional beamforming methods inevitably have limited spatial resolution depending on the number of sensors used and the aperture size. A high-resolution ultrasound imaging technique was implemented by applying functional beamforming as a method to overcome the geometric constraints of the array. The functional beamforming method can be expressed as a generalized beam forming method mathematically, and has the advantage of being able to obtain high-resolution imaging by reducing main-lobe width and side lobes. As a result of observation through computer simulation, it was verified that the resolution of the ultrasonic source in the air was successfully increased by functional beamforming using the ultrasonic sparse array.

A Study on the Development of High-intensity focused Ultrasound Device for the Beauty Treatment Health Care (미용 치료 헬스케어를 위한 고강도 집속 초음파 장치 개발 연구)

  • Lee, Woo-Cheol;Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.12
    • /
    • pp.1259-1264
    • /
    • 2016
  • Ultrasonic therapy has received great attention in the field of cosmetics related to the treatment of skin thickening because of its fast recovery and safety. In this study, an output circuit of a high intensity focused ultrasound system was developed for the treatment of beauty. To verify the applicability of the high intensity focused ultrasound system to the cosmetic treatment field, we measured and analyzed the 3D ultrasound intensity energy using a hydrophone. And high-intensity focused ultrasound devices were found to be useful for cosmetic treatment.

Study of Ultrasonic 3-Dimensional Image Reconstruction (초음파를 이용한 3차원 영상 재구성에 관한 연구)

  • 안승옥;홍기상
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.18 no.2
    • /
    • pp.54-63
    • /
    • 1981
  • An ultrasonic imaging system with fan reflection mode time of fight is developed and its performance has been examined by system implementation. Experimental results obtained indicafe potential of the method for tomographic imaging. The basic concept of this method is reconstruction of reflectivity with reflection data collected in fan mode using a new "arbitrary ray" reconstruction algorithm. Computer simulations as well as experimental results are presented.presented.

  • PDF

Detecting the Prostate Boundary with Gabor Texture Features Average Shape Model of TRUS Prostate Image (TRUS 전립선 영상에서 가버 텍스처 특징 추출과 평균형상모델을 적용한 전립선 경계 검출)

  • Kim, Hee Min;Hong, Seok Won;Seo, Yeong Geon;Kim, Sang Bok
    • Journal of Digital Contents Society
    • /
    • v.16 no.5
    • /
    • pp.717-725
    • /
    • 2015
  • Prostate images have been used in the diagnosis of prostate using TRUS images being relatively cheap. Ultrasound images are recorded with 3 dimension and one diagnostic exam is made with a number of the images. A doctor can see 2 dimensional images on the monitor sequentially and 3 dimensional ones to diagnose a disease. To display the images, 2-d images are used with raw 2-d ones, but 3-d images need to be segmented by the prostates and their backgrounds to be seen from different angles and with cut images of inner side. Especially on detecting the boundary, the ones in the middle of all images are easy to find the boundary but the base and apex of the images are hard to do it since there are lots of uncertain boundary. So, in this paper we propose the method that applies an average shape model and detects the boundary, and shows its superiority compared to the existing methods with experiments.

Nondestructive Diagnosis of NPP Piping System Using Ultrasonic Wave Imaging Technique Based on a Pulsed Laser Scanning System (펄스 레이저 스캐닝 기반 초음파 영상화 기술을 활용한 원전 배관 비파괴 진단)

  • Kim, Hyun-Uk;Lee, Chang-Gil;Park, Seung-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.166-173
    • /
    • 2014
  • A noncontact nondestructive testing (NDT) method is proposed to detect the damage of pipeline structures and to identify the location of the damage. To achieve this goal, a scanning laser source actuation technique is utilized to generate a guided wave and scans a specific area to find damage location more precisely. The ND: YAG pulsed laser is used to generate Lamb wave and a piezoelectric sensor is installed to measure the structural responses. The measured responses are analyzed using three dimensional Fourier transformation (3DFT). The damage-sensitive features are extracted by wavenumber filtering based on the 3D FT. Then, flaw imaging techniques of a pipeline structures is conducted using the damage-sensitive features. Finally, the pipes with notches are investigated to verify the effectiveness and the robustness of the proposed NDT approach.