• Title/Summary/Keyword: 3중 접합

Search Result 432, Processing Time 0.025 seconds

Automatic Identification of the Lumen Border in Intravascular Ultrasound Images (혈관 내 초음파 영상에서 내강 경계면 자동 분할)

  • Park, Jun-Oh;Ko, Byoung-Chul;Park, Hee-Jun;Nam, Jae-Yeal
    • The KIPS Transactions:PartB
    • /
    • v.19B no.3
    • /
    • pp.201-208
    • /
    • 2012
  • Accurately segmenting lumen border in intravascular ultrasound images (IVUS) is very important to study vascular wall architecture for diagnosis of the cardiovascular diseases. After each of IVUS image is transformed to a polar coordinated image, initial points are detected using wavelet transform. Then, lumen border is initialized as the set of important points using non parametric probability density function and smoothing function by removing outlier initial points occurred by noises and artifacts. Finally, polynomial curve fitting is applied to obtain real lumen border using filtered important points. The evaluation of proposed method was performed with related method and the proposed method produced accurate lumen contour detection when compared to another method in most types of IVUS images.

The Evaluation for Stability at Joint Part in Composition Dam (복합댐 접합부의 안정성 평가)

  • Kim, Jae-Hong;Oh, Byung-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.3
    • /
    • pp.155-166
    • /
    • 2008
  • Research dam is consisted of concrete gravity dam that right bank department is built to concrete material, left bank department is composition dam that is consisted of rockfill dam that consist of rockfill material In domestic case, composition dam form of storage of water facilities of about 17,000 does not exist hardly in dam of irrigation water industry drinking water purpose that manage local government or other institution, Even if exist, is real condition that there is total nonexistence administrator fare of facilities, Choose unique dam of domestic multipurpose dam and analyzed conduct special quality of con'c gravity dam and rockfill dam joint part To analyze dynamic conduct special quality of composition dam by analytic method in this research, Do modelling via axis of dam and achieved static(Psuedo-static, modify Psuedo-static) and dynamic analysis, When achieving earthquake response analysis, analyzed seismic response analysis between concrete part and rockfill's part.

Status and Prospect of Site Welding Technology for LNG Strorage Tank (LNG 저장탱크의 현장용접 시공기술의 현상 및 전망)

  • 이광희;전혁성
    • Journal of Welding and Joining
    • /
    • v.13 no.3
    • /
    • pp.8-17
    • /
    • 1995
  • LNG를 저장할 수 있는 탱크는 주로 지상식이거나 반지하식이며 그 용량은 매우 다양하다. 우리나라에서는 지상식 탱크가 평택 인수기지에 10만m$^{3}$급 Membrane Type 6기가 건설되었고 1기는 거의 완성단계이며, 현재 추가로 건설 중인 3기를 포함하면 총 10기의 탱크를 확보하게 된다. 또한 제2인수기지인 인천에도 동급 으로서 9%Ni강을 사용하는 Double Wall Type LNG 탱크 3기를 건설 중이다. 전세계적 으로 볼 때 LNG 저장 탱크의 78%는 지상식으로 Double Wall Type 또는 Membrane 저장 탱크 형식을 취하고 있으나, 최근에는 안전성 측면, 토지 가격의 상승, 토지의 합리적 이용 측면 등을 감안하여 LNG 탱크를 지하화, 대형화하는 추세이다. 본고에서는 Fig. 1과 같은 구조의 Double Wall Type LNG 저장탱크 중 초저온의 LNG에 직접 접하는 저 온용 재료(9%니켈강)로 만들어지는 내조 용접에 대해서 중점적으로 논하기로 하며, 특히 9% 니켈강 Shell Plate Horizontal Joint에 채용되는 Automatic Submerged ARC 용접에 대해 실제 현장 용접 시공상태를 나타내고자 한다.

  • PDF

Seismic Performance Evaluation of R/C Frame Apartment Strengthened with Kagome Truss Damper External Connection Method by Pseudo Dynamic Test (유사동적실험에 의한 외부접합형 카고메 트러스 제진장치가 설치된 RC 라멘조 공동주택의 내진성능 평가)

  • Heur, Moo-Won;Chun, Young-Soo;Hwang, Jae-Seung;Lee, Kang-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.23-34
    • /
    • 2015
  • Recently a new damper system with Kogome truss structure was developed and its mechanical properties were verified based on the laboratory test. This paper presents a Kagome truss damper external connection method for seismic strengthening of RC frame structural system. The Kagome external connection method, proposed in this study, consisted of building structure, Kagome damper and support system. The method is capable of reducing earthquake energy on the basis of the dynamic interaction between external support and building structures using Kagome damper. The pseudo-dynamic test, designed using a existing RC frame apartment for pilot application of LH corporation, was carried out in order to verify the seismic strengthening effects of the proposed method in terms of the maximum load carrying capacity and response ductility. Test results revealed that the proposed Kagome damper method installed in RC frame enhanced conspicuously the strength and displacement capacities, and the method can resist markedly under the large scaled earthquake intensity level.

Theoretical Models for Predicting Racking Resistance of Shear Walls (전단벽의 전단성능 예측 모형)

  • Jang, Sang Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.96-105
    • /
    • 2002
  • Shear wall is the most important component resisting lateral loads imposed to a building by wind or earthquake. In shear walls, lateral load applied to framing is transmitted to sheathing panel through nailed joints between sheathing and framing so that the load is resisted by in-plane shear strength of sheathing. Therefore, nailed joints are the most basic and important component in the viewpoint of stiffness and strength of shear walls. In this study, stiffness and strength of single nailed joint were measured by single shear tests of nailed joints and used as input for theoretical models developed to estimate racking behavior of shear walls. And shear walls were tested to check the accuracy of theoretical models estimating racking resistance of shear walls. Stiffness of nailed joint was affected by grain direction of stud but direction of sheathing panel had little effect. Behavior of nailed joint and shear walls under lateral loads could be represented by three lines. Theoretical model II was more accurate than theoretical model I in estimating racking behavior of shear wall under loads.

Dynamic Analysis of Superstructures on Very Large Floating Structure with Semi-Rigid Connections (반강접 접합부를 적용한 초대형 부유식 구조물 상부구조체에 대한 동적해석)

  • Song Hwa-Cheol;Kim Woo-Nyon
    • Journal of Navigation and Port Research
    • /
    • v.29 no.5 s.101
    • /
    • pp.389-394
    • /
    • 2005
  • The additional moment occurs because the superstructures of VLFS are influenced by wave loads instead of earthquake loads. In order to reduce the additional moment, this study used the semi-rigid connections which lie between fully rigid and pinned. If the semi-rigid connections are used for superstructures of VLFS, the moment of beams can be reduced and more economical construction will be possible. This study aims to show the effect of wave loads on structure and the efficiency of the semi-rigid connections due to wave loads by analyzing the time history responses. The dynamic behaviors of the rigid frame are compared with those of the semi-rigid frame considering of static loads, wave loads and combination loads for a four-bay, three-story frames. The semi-rigid connection type is a steel tubular column with square external-diaphragm connections and the time history analysis is used for the dynamic responses. The additional moment responses due to wave loads increase $33\%$ in the rigid frame, $26\%$ in the semi-rigid frame with the spring model.

Performance of Feature-based Stitching Algorithms for Multiple Images Captured by Tunnel Scanning System (터널 스캐닝 다중 촬영 영상의 특징점 기반 접합 알고리즘 성능평가)

  • Lee, Tae-Hee;Park, Jin-Tae;Lee, Seung-Hun;Park, Sin-Zeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.30-42
    • /
    • 2022
  • Due to the increase in construction of tunnels, the burdens of maintenance works for tunnel structures have been increasing in Korea. In addition, the increase of traffic volume and aging of materials also threatens the safety of tunnel facilities, therefore, maintenance costs are expected to increase significantly in the future. Accordingly, automated condition assessment technologies like image-based tunnel scanning system for inspection and diagnosis of tunnel facilities have been proposed. For image-based tunnel scanning system, it is key to create a planar image through stitching of multiple images captured by tunnel scanning system. In this study, performance of feature-based stitching algorithms suitable for stitching tunnel scanning images was evaluated. In order to find a suitable algorithm SIFT, ORB, and BRISK are compared. The performance of the proposed algorithm was determined by the number of feature extraction, calculation speed, accuracy of feature matching, and image stitching result. As for stitching performance, SIFT algorithm was the best in all parts of tunnel image. ORB and BRISK also showed satisfactory performance and short calculation time. SIFT can be used to generate precise planar images. ORB and BRISK also showed satisfactory stitching results, confirming the possibility of being used when real-time stitching is required.

Application of Improved Invert in Combining Manhole (합류맨홀에서 개선형 인버트의 적용)

  • Jo, Jun Beom;Lee, Min Sung;Rim, Chang Soo;Yoon, Sei Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.287-287
    • /
    • 2018
  • 우수관거 시설에서 맨홀은 관거의 접합을 위해 반드시 설치되어야 하는 중요한 요소이다. 이러한 맨홀 접합부에서는 유입관으로 유입되는 유량의 급격한 확대와 유출관으로 배수되는 유량의 급격한 축소 등 흐름의 복잡한 변화가 발생한다. 맨홀에서의 복잡한 흐름은 설계강우를 초과하지 않는 강우량에서 과부하 조건을 형성하며 도심지 침수의 심각한 영향을 미친다. 특히 여러 관이 접합되어 있는 합류맨홀의 경우 유출관거로의 원활한 배수가 유도되지 않을 뿐 아니라 다양한 방향의 흐름이 서로 상충하며 급격한 에너지 손실을 유발한다. 도심지 중 하류부에서 주로 발생하는 침수피해는 복잡한 우수관거 시설의 구성에 따른 합류맨홀의 증가로 인해 그 규모가 늘어나는 추세이다. 바닥이 평평한 기본형태의 맨홀에서 발생되는 과부하 흐름과 여러 유량 조건에서의 에너지 손실에 관한 연구는 지속적으로 수행되어왔다. 최근 맨홀 내부에 흐름을 유도시켜주는 인버트를 설치하여 에너지 손실을 저감하려는 연구가 활발히 이루어지고 있지만 이를 실제 도시지역에 적용하여 침수해석이나 관거 배수능력 평가를 수행하기 위한 필요한 기초자료는 미비한 실정이다. 본 연구에서는 인버트가 설치된 개선형 4방향 합류맨홀의 유량 조건을 다양하게 변화시키며 유입유량 조건에 따른 개선형 맨홀의 손실계수를 분석하였다. 유량 조건은 세 개의 유입관에서 각각 설계유량 $1{\ell}/s$의 유량이 유입되는 총 유입유량 $3{\ell}/s$를 기준으로 각 유입관의 유입유량을 10%씩 변화시킨 40case의 유량 조건을 선정하였다. 이렇게 선정된 유량 조건은 경우에 따라 중간 맨홀, 3방향 합류맨홀 또는 4방향 합류맨홀의 흐름을 다양하게 나타내었으며, 40case의 손실계수를 분석하여 모든 맨홀 접합 조건에서의 손실계수를 파악할 수 있었다. 합류맨홀에서의 개선형 인버트 적용성을 확인하기 위하여 인버트가 설치된 개선형 맨홀에서 산정된 손실계수를 기초로 모든 유입유량 조건에서 적용이 가능한 손실계수 범위도를 작도하였다. 손실계수 범위도는 통계분석에 활용되어 개선형 맨홀의 유입유량 조건에 따른 손실계수 산정식을 도출하는 기초자료로 활용되었다. 이와 같이 도출된 산정식을 적용하면 실제 도심지에 개선형 맨홀을 적용하였을 경우에도 정확한 침수 해석이나 관거 배수능력 평가가 가능할 것으로 판단된다.

  • PDF

Effect of Interlayer Materials on Bending Strength and Reliability of Si$_3$N$_4$/S. S316 Joint (Si$_3$N$_4$/S. S316 접합에서 중간재가 접합강도 및 신회도에 미치는 영향)

  • 윤호욱;박상환;최성민;임연수;정윤중
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.3
    • /
    • pp.219-230
    • /
    • 1998
  • Various interlayer materials have been tested for active metal(Cusil ABA) brazing of Si3N4/S. S316 joint. In general multilayer joint had higher strength(80-150 MPa) and better reliability than monolayered one. The joint with Cu(0.2)/Mo(0.3)/Cu(0.2mm) interlayer showed the highest bending strength of abou 490 MPa and the joint with Cu(0.2)/Mo(0.3mm) interlayer the best reliability (14.6 Weibull modulus). The stresses distributed in joint materials during 4-point bending test were estimated by CAE von Mises analysis; the estimated stresses were In good agreement with the measured data. In multilayer joint Cu was though to reduce the residual stresses induced by the difference in thermal expansion coefficient between the ceramic Mo and metal It apperared that a Cu/Mo was optimum interlayer material for Si3N4/S. S316 joint with high bending strength (420 MPa) and reliability. In addition the various shapes and types of compound were examined by EPMA in joining interface.

  • PDF

The effects of hydrogen treatment on the properties of Si-doped Ga0.45In0.55P/Ge structures for triple junction solar cells

  • Lee, Sang-Su;Yang, Chang-Jae;Ha, Seung-Gyu;Kim, Chang-Ju;Sin, Geon-Uk;O, Se-Ung;Park, Jin-Seop;Park, Won-Gyu;Choe, Won-Jun;Yun, Ui-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.143-144
    • /
    • 2010
  • 3-5족 화합물 반도체를 이용한 집광형 삼중 접합 태양전지는 40% 이상의 광변환 효율로 많은 주목을 받고 있다[1]. 삼중 접합 태양전지의 하부 셀은 기계적 강도가 높고 장파장을 흡수할 수 있는 Ge이 사용된다. Ge위에 성장될 III-V족 단결정막으로서 Ge과 격자상수가 일치하는 GaInP나 GaAs가 적합하고, 성장 중 V족 원소의 열확산으로 인해 Ge과 pn접합을 형성하게 된다. 이때 GaInP의 P의 경우 GaAs의 As보다 확산계수가 낮아 태양전지 변환효율향상에 유리한 얇은 접합 형성이 가능하고, 표면 에칭효과가 적기 때문에 GaInP를 단결정막으로 선택하여 p-type Ge기판 위 성장으로 단일접합 Ge구조 제작이 가능하다. 하지만 이종접합 구조 성장으로 인해 발생한 계면사이의 전위나 미세결함들이 결정막내부에 존재하게 되며 이러한 결함들은 광학소자 응용 시 비발광 센터로 작용할 뿐 아니라 소자의 누설전류를 증가시키는 원인으로 작용하여 태양전지 변환효율을 감소시키게 된다. 이에 결함감소를 통해 소자의 전기적 특성을 향상시키고자 수소 열처리나 플라즈마 공정을 통해 수소 원자를 박막내부로 확산시키고, 계면이나 박막 내 결함들과 결합시킴으로서 결함들의 비활성화를 유도하는 연구가 많이 진행되어 왔다 [2][3]. 하지만, 격자불일치를 갖는 GaInP/Ge 구조에 대한 수소 열처리 및 불순물 준위의 거동에 대한 연구는 많이 진행되어 있지 않다. 따라서 본 연구에서는 Ga0.45In0.55P/Ge구조에 수소 열처리 공정을 적용을 통하여 단결정막 내부 및 계면에서의 결함밀도를 제어하고 이를 통해 태양 전지의 변환효율을 향상시키고자 한다. <111> 방향으로 $6^{\circ}C$기울어진 p-type Ge(100) 기판 위에 유기금속화학증착법 (MOCVD)을 통해 Si이 도핑된 200 nm의 n-type GaInP층을 성장하여 Ge과 단일접합 n-p 구조를 제작하였다. 제작된 GaInP/Ge구조를 furnace에서 250도에서 90~150분간 시간변화를 주어 수소열처리 공정을 진행하였다. 저온 photoluminescence를 통해 GaInP층의 광학적 특성 변화를 관찰한 결과, 1.872 eV에서 free-exciton peak과 1.761 eV에서 Si 도펀트 saturation에 의해 발생된 D-A (Donor to Acceptor)천이로 판단되는 peak을 검출할 수 있었다. 수소 열처리 시간이 증가함에 따라 free-exciton peak 세기 증가와 반가폭 감소를 확인하였고, D-A peak이 사라지는 것을 관찰할 수 있었다. 이러한 결과는 수소 열처리에 따른 단결정막 내부의 수소원자들이 얕은 불순물(shallow impurity) 들로 작용하는 도펀트들이나, 깊은 준위결함(deep level defect)으로 작용하는 계면근처의 전위, 미세결함들과의 결합으로 결함 비활성화를 야기해 발광세기와 결정질 향상효과를 보인 것으로 판단된다. 본 발표에서는 상술한 결과를 바탕으로 한 수소 열처리를 통한 박막 및 계면에서의 결함준위의 거동에 대한 광분석 결과가 논의될 것이다.

  • PDF