• 제목/요약/키워드: 3상 DC/AC 인버터

검색결과 46건 처리시간 0.02초

4-레그 PWM 컨버터/인버터와 AC 리액터를 사용한 새로운 3상 라인 인터렉터브 무정전전원장치의 개발 (Development of Novel 3-Phase Line-interactive UPS System using 4-leg PWM Converter/Inverter and AC Reactor)

  • 지준근;김효성;설승기;김경환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.77-81
    • /
    • 2004
  • In this paper a novel line interactive UPS (Uninterruptible Power Supply) using the two 4-leg VSCs and AC line reactor is proposed. The 4-leg Voltage Source Converter(VSC) can use the DC link voltage effectively by the 3-D SVPWM method. Hence the DC battery voltage can be reduced by $15\%$ in comparison to that of the conventional line-interactive UPS system. One VSC is in parallel with the AC line reactor of the power source side, and the other is in series with the load. The parallel 4-leg voltage source inverter controls three-phase line voltage independently in order to control the line reactor current indirectly. It eliminates the neutral line current and the active ripple power of the source side using the pqr theory so that unity power factor and the sinusoidal source current can be achieved even though both the source and the load voltages have zero sequence components. The series 4-leg voltage source inverter compensates the line voltage and allows the load voltage to be balanced and harmonic-free. Both of parallel and series 4-leg voltage source inverters always act as independently controllable voltage sources, so that three-phase output voltage shows a seamless transition to the backup mode. The feasibility of the proposed UPS system has been investigated and verified through computer simulation results.

  • PDF

3상 레귤러 샘플링 PWM 인버터의 출력파행 분석에 관한 연구 (A Study on the Analysis of the Output Waveform of Three-Phase Regular Sampling PWM Inverter)

  • 노창주
    • 수산해양기술연구
    • /
    • 제28권3호
    • /
    • pp.274-285
    • /
    • 1992
  • Among various Power converters, a variable voltage variable frequency (VVVF) three-phase PWM inverter is regarded as most promising power converter due to its capabilities, which permits the control of voltage, frequency and harmonic contents in a single power stage employing only on DC source. As a modulating technique of the PWM inverter, the regular sampling technique has rendered possible the on-line computation and generation of PWM control waveforms with a reasonably high switching frequencies. In this paper, microprocessor based three-phase regular samping PWM inverter with real-time control algorithm and control circuits for driving three phase AC motor has been developed. Harmocic components of PWM waveform were analized theoretically in terms of Bessel function series and then calculated by digital computer and observed with spectrum analyzer.

  • PDF

3상 임베디드 Z-소스 인버터 (Three Phase Embedded Z-Source Inverter)

  • 오승열;김세진;정영국;임영철
    • 전력전자학회논문지
    • /
    • 제17권6호
    • /
    • pp.486-494
    • /
    • 2012
  • In this paper, we proposes the three-phase embedded Z-source inverter consisting of the three embedded Z-source converters and it's the output voltage control method. Each embedded Z-source converter can produce the bipolar output capacitor voltages according to duty ratio D such as single-phase PWM inverter. The output AC voltage of the proposed system is obtained as the difference in the output capacitor voltages of each converter, and the L-C output filter is not required. Because the output AC voltage can be stepped up and down, the boost DC converter in the conventional two-stage inverter is unnecessary. To confirm the validity of the proposed system, PSIM simulation and a DSP based experiment were performed under the condition of the input DC voltage 38V, load $100{\Omega}$, and switching frequency 30kHz. Each converter is connected by Y-connection for three-phase loads. In case that the output phase voltage is the same $38V_{peak}$ as the input DC voltage and is the 1.5 times($57V_{peak}$), the simulation and experimental results ; capacitor voltages, output phase voltages, output line voltages, inductor currents, and switch voltages were verified and discussed.

3상 인버터에서의 직류단 단일 션트 저항을 이용한 평균 상전류 추정 방법 (Average Phase Current Estimation Method using a DC Link Shunt Resistor in the Three-Phase Inverter)

  • 구현근;염한범;김장목
    • 전력전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.343-350
    • /
    • 2016
  • Generally, the average phase current is sampled at the midpoint of a PWM signal for the vector control of an AC motor. The three-phase current can also be reconstructed from a DC-link shunt resistor by sampling the shunt voltage during the active vectors of the SVPWM. However, the reconstructed current is different from the average current because of the deviation of the sampling point from the midpoint of the PWM signal. This paper proposes an algorithm to estimate the average current from the reconstructed current in a single-shunt inverter. The proposed method is derived from the phase current slopes based on switching states and corresponding switching time. In addition, the proposed method is generalized for all the six sectors of the space vector hexagon. The validity of the proposed algorithm is verified with simulations and experiments.

새로운 영상전류 주입법에 의한 다이오드 정류기의 고조파 저감 (Harmonic Reduction of Diode Rectifiers by a New Zero-Sequence Current Injection Method)

  • 김현정;장민수;최세완;원충연;김규식
    • 전력전자학회논문지
    • /
    • 제7권6호
    • /
    • pp.596-603
    • /
    • 2002
  • 본 논문에서는 영상고조파 주입법을 사용하여 3상 다이오드 정류기의 입력전류를 개선하는 새로운 방식의 고조파 저감기술을 제안한다. 3고조파 주입을 근간으로 하는 본 방식은 다이오드 정류기의 상측과 하측의 전류를 독립적으로 제어하기 위하여 두 대의 단상 반파 인버터와 두 대의 단상 변압기로 구성되어져 있다. 이렇게 만들어진 영상전류는 zigzag 변압기에 의해서 다이오드 정류기의 상측과 하측으로 주입이 되어진다. 이 결과 3상 다이오드 정류기의 입력전류는 순수한 정현파 전류가 된다. 본 방식의 타당성을 1.5kVA 시작품의 실험을 통하여 입증하였다.

3상 양방향 인버터의 계통전압 불평형 및 왜곡에 의한 계통전류 불평형 및 왜곡 보상 (A Compensation of the Grid Current Unbalance and Distortion caused by the Grid Voltage Unbalance and Distortion in 3-Phase Bi-Directional DC to AC Inverter)

  • 양승대;김승민;최주엽;최익;송승호;이상철;이동하
    • 전력전자학회논문지
    • /
    • 제18권2호
    • /
    • pp.161-168
    • /
    • 2013
  • This paper presents an algorithm of a compensation of the grid current distortion caused by the grid voltage unbalance and distortion in 3-phase bi-directional DC to AC inverter. Usually 3-phase grid system has unbalance and distortion because of connecting 1-phase and non-linear load with 3-phase load using same input node. Controlling 3-phase inverter by general method under the unbalanced and distorted grid voltage, the grid current has distortion. This distortion of the grid current cause the grid voltage distortion again. So, it need to control the grid current balanced and non-distorted, even the grid voltage gets unbalanced and distorted. There are some complex method to compensate the gird current distortion. it suggest simple method to solve the problem. Simulation and experiment is used to validate the proposed algorithm.