• Title/Summary/Keyword: 3상 6펄스 정류기

Search Result 5, Processing Time 0.022 seconds

A Study on the D-Q Control based Output Voltage Control Algorithm and EMTP-RV Simulation of Three-phase 6-Pulse PWM Rectifier (3상 6펄스 PWM 정류기의 D-Q 제어 기반 출력전압 제어 알고리즘 및 EMTP-RV 시뮬레이션 연구)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.1
    • /
    • pp.45-52
    • /
    • 2021
  • The space vector control based voltage control method for a three-phase PWM rectifier requires a lot of effort to design an optimal switching pattern since a switching pattern for the switching section must be designed. In this study, a D-Q control based SPWM output voltage control algorithm was studied for the three-phase six-pulse CVS type rectifier. In the output voltage control algorithm, three-phase reference signals are obtained from the D-Q transformation based on the space vector representation method, instead of the switching pattern, SPWM method is used to generate rectifier switching control signals. Next, a three-phase six-pulse CVS PWM rectifier based on D-Q transformation and SPWM was modeled using EMTP-RV. Finally, the validity of the D-Q control-based SPWM voltage control algorithm was confirmed by comparing the output voltage waveform obtained through EMTP-RV simulation works with a reference value and confirming that the output voltage accurately follows the reference voltage.

Analysis of the performance of a 4.2MW (600VDC, 7kADC) DC pulsed power supply (4.2MW (600VDC, 7kADC)직류 펄스 전원장치의 성능분석)

  • 노의철
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.6
    • /
    • pp.73-80
    • /
    • 1996
  • 본 논문은 펄스 형태의 출력전류를 얻기 위한 직류 직원 장치의 성능분석에 관한 것이다. 직류 전원장치의 입력은 3상 3,300[V]이고 펄스 출력용량은 4.2MW( 600VDC, 7kADC)이며 용도는 플라즈마의 밀폐 및 구속을 위한 전자적 구동용이다. 펄스폭인 10초인 펄스 파형이 150초 주기로 출력되면서 동작함에 따라 전원장치를 구성하는 변압기와 위상제어 정류기의 용량선정시 전원장치의 성능과 설비비를 고려하여 최적화할 필요가 있다. 본 논문에서는 변압기의 용량선정시 역률과 전압강하를 고려하여 가능한 한 용량을 최소화하였으며 선정된 변압기에 대하여 변압기의 %Z에 따른 직류 출력전압 강하, 역류, 전고조파 왜율 등의 특성을 시뮬레이션을 통하여 분석하였으며 제작된 전원장치의 실험을 통하여 분석하였으며 제작된 전원장치의 실험을 통하여 분석의 타당성을 검증하였다. 특히, 전원장치의 과부하 동작시 변압기의 %Z가 출력성능에 미치는 영향에 대하여 중점적으로 시뮬레이션 하였으며 실험적으로 확인하였다.

  • PDF

A Study on The Three-Phase Active Power Filter Using Voltage-Source PWM Converter (전압형 PWM 컴버터를 이용한 3상 능동 전력 필터에 관한 연구)

  • 박민호;김한성;최규하;이제필
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.5
    • /
    • pp.370-379
    • /
    • 1989
  • This paper describes a three-phase active power filter using voltage-source PWM converter, which can eliminate the harmonics and compensate the reactive power in the ac sides of 6-pulse rectifier. The active filter consists of three-phase PWM inverter and a capacitor, and the hysteresis control technique is used to make the compensating current close to the existing harmonic current and also to improve the response of the filter with simple control circuit. As a result the compensated ac line current becomes sinusoidal and the input power factor is improved roughly to unity.

A Study of LCD Panel Cleaning Effect of Plasma Generation Power Source (플라즈마 발생용 전원장치의 LCD 패널 세정효과에 관한 연구)

  • Kim, Gyu-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.5
    • /
    • pp.44-51
    • /
    • 2008
  • UV lamp systems have been used for cleaning of display panels of TFT LCD or Plasma Display Panel (PDP). However, the needs for high efficient cleaning and low cost made high voltage plasma cleaning techniques to be developed and to be improved. Dielectric-Barrier Discharges (DBDs), also referred to as barrier discharges or silent discharges have been exclusively related to ozone generation for a long time. In this paper, a 6kW high voltage plasma power supply system was developed for LCD cleaning. The 3-phase input voltage is rectified and then inverter system is used to make a high frequency pulse train, which is rectified after passing through a high-power transformer. Finally, hi-directional high voltage pulse switching circuits are used to generate the high voltage plasma. Some experimental results showed the usefulness of atmospheric plasma for LCD panel cleaning.

A Study to Improve the DC Output Waveforms of AFE Three-Phase PWM Rectifiers (AFE 방식 3상 PWM 정류기의 직류 출력파형 개선에 관한 연구)

  • Jeon, Hyeon-Min;Yoon, Kyoung-Kuk;Kim, Jong-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.6
    • /
    • pp.739-745
    • /
    • 2017
  • Many studies have been conducted to reduce environmental pollution by ships and reduce fuel consumption. As part of this effort, research on power conversion systems through DC distribution systems that link renewable energy with conventional power grids has been pursued as well. The diode rectifiers currently used include many lower harmonics in the input current of the load and distort supply voltage to lower the power quality of the whole system. This distortion of voltage waveforms causes the malfunctions of generators, load devices and inverter pole switching elements, resulting in a large number of switching losses. In this paper, a controller is presented to improve DC output waveforms, the input Power Factor and the THD of an AFE type PWM rectifier used for PLL. DC output voltage waveforms have been improved, and the input Power Factor can now be matched to the unit power factor. In addition, the THD of the input power supply has been proven by simulation to comply with the requirements of IEEE Std514-2014.