• Title/Summary/Keyword: 3변의 합의 크기

Search Result 15, Processing Time 0.035 seconds

A study on the Logical Reclassification of Parcel Service Tariffs (택배요금기준의 합리적 재설정에 관한 연구)

  • Cho, Yoon-Sung;Lee, Tae-Hwee
    • Journal of Distribution Science
    • /
    • v.10 no.5
    • /
    • pp.45-55
    • /
    • 2012
  • In Korea, the parcel delivery service was launched officially in 1992, and the market has grown to 13.2 billion units, or 3.5 trillion won, as of 2011. The service companies accept small packages under 30 kg and deliver them on the next day in most domestic areas. This service plays an important role in business and personal activities. The parcel service companies have themselves designed the tariff for the delivery service based on two criteria: weight and the sum of three side lengths. Further, the tariff is graded in steps of three or four rate structures based on size (small, medium, large, and extra-small). However, the basic freight rate is generally decided according to the cargo's weight or measurement size, and an extra rate is added according to some factors (handling, stowability, liability, and so on). The parcel service tariff adopted by the companies is illogically designed, and this study was carried out to assess the need for redesigning the tariff structure. The cargo volume cannot be logically reflected by three side lengths. For example, two parcels measuring 160 cm based on three side lengths may have different volumes, one measuring 0.152 cbm (53.33 cm × 53.33 cm × 53.34 cm) and the other 0.05 cbm (100 cm × 50 cm × 10 cm). A small package of less than120 cm (sum of three side lengths) may have a volume of as much as 0.064 cbm (40 cm × 40 cm × 40 cm). Sample comparison showed that 17% of medium-size parcels (based on the sum of three side lengths) are small-volume packages, 24% of large-size parcels are small- or medium-volume packages, and 40% of extra-big-size parcels are big- or under-size packages. Therefore, if parcel service companies rate their services for volume cargo based on the three side lengths standard, users may have to pay higher than normal rates, particularly because a large percentage of parcels are volume cargo. According to this study, the average weight per 1 cbm is less than 300 kg. Therefore, users face an increasing risk of paying higher than logical freight charges. Generally, transportation companies are called "public interest enterprises," and parcel service companies operate as postal services. Public interest enterprises must provide the delivery service to all customers without discrimination at a reasonable service level and logical service charges. Therefore, parcels service tariffs must be designed and adopted logically. In this study, freight theories and prior research findings were used to consider the importance of freight rates, and distortion of parcel service rates based on the three side lengths system was verified through regression analysis of a parcel sample and sample comparison. In conclusion, volume sizes based on three side lengths have a higher correlation to the rate level than does the sum of three side lengths. Further, compared to the sum of three side lengths, volume size has a higher correlation to cargo weight, which is the most basic factor determining transportation cost. Therefore, the existing parcel service tariff should be changed to weight- and volume-based rates, and the tariff must be graded in steps of 8 to 10 higher rate structures for a logical freight schedule based on service cost.

  • PDF

A Cumulative Damage Theory of Concrete under Variable Amplitude Fatigue Loadings (변동진폭(變動振幅)의 피로하중(疲勞荷重)을 콘크리트의 누적손상이론(累積損傷理論))

  • Oh, Byung Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.6 no.4
    • /
    • pp.79-88
    • /
    • 1986
  • A nonlinear cumulative damage theory, which can model the effects of the magnitude and sequence of variable amplitude fatigue loadings, is proposed. The concrete beam specimens are prepared and tested in four-point flexural loading conditions. The variable-amplitude fatigue loadings in two and three stages are considered. The present experimental study indicates that the fatigue failure of concrete is greatly influenced by the magnitude and sequence of applied, variable-amplitude fatigue loadings. It is seen that the linear damage theory proposed by Palmgren and Miner is not directly applicable to the concrete under such loading cases. The sum of the cumulative damage is found to be greater than 1 when the magnitude of fatigue loading is gradually increased and less than 1 when the magnitude of fatigue loading is gradually decreased. The proposed nonlinear damage theory, which includes the effects of the magnitude and sequence of applied fatigue loadings, allows more realistic fatigue analysis of concrete structures.

  • PDF

Study of Rainfall-Runoff Variation by Grid Size and Critical Area (격자크기와 임계면적에 따른 홍수유출특성 변화)

  • Ahn, Seung-Seop;Lee, Jeung-Seok;Jung, Do-Joon;Han, Ho-Chul
    • Journal of Environmental Science International
    • /
    • v.16 no.4
    • /
    • pp.523-532
    • /
    • 2007
  • This study utilized the 1/25,000 topographic map of the upper area from the Geum-ho watermark located at the middle of Geum-ho river from the National Geographic Information Institute. For the analysis, first, the influence of the size of critical area to the hydro topographic factors was examined changing grid size to $10m{\times}10m,\;30m{\times}30m\;and\;50m{\times}50m$, and the critical area for the formation of a river to $0.01km^2{\sim}0.50km^2$. It is known from the examination result of watershed morphology according to the grid size that the smaller grid size, the better resolution and accuracy. And it is found, from the analysis result of the degree of the river according to the minimum critical area for each grid size, that the grid size does not affect on the degree of the river, and the number of rivers with 2nd and higher degree does not show remarkable difference while there is big difference in the number of 1st degree rivers. From the results above, it is thought that the critical area of $0.15km^2{\sim}0.20km^2$ is appropriate for formation of a river being irrelevant to the grid size in extraction of hydro topographic parameters that are used in the runoff analysis model using topographic maps. Therefore, the GIUH model applied analysis results by use of the river level difference law proposed in this study for the explanation on the outflow response-changing characters according to the decision of a critical value of a minimum level difference river, showed that, since an ogival occurrence time and an ogival flow volume are very significant in a flood occurrence in case of not undertow facilities, the researcher could obtain a good result for the forecast of river outflow when considering a convenient application of the model and an easy acquisition of data, so it's judged that this model is proper as an algorism for the decision of a critical value of a river basin.

A Study on Coupling Coefficient and Resonant Frequency Controllable Internal PIFA (결합계수 및 공진 주파수 조절이 가능한 내장형 PIFA에 관한 연구)

  • Lee, Sang-Hyun;Lee, Moon-Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.10
    • /
    • pp.99-104
    • /
    • 2010
  • In this paper, the internal antenna for mobile communication handset which is able to control both coupling coefficient and resonant frequency without any major modification of radiator and ground plane of PIFA(Planner Inverted F Antenna). The resonant frequency as well as amount of coupling between feeding point and shorting post can be adjusted by changing inductance. Because the inductor is connected on shorting post where the strength of electric field is weak, the performance reduction of the proposed antenna is very small enough to neglect. For the variation of the inductance value within 3.3nH, the resonant frequency of antenna can have operating range of 1650MHz ~ 1830MHz. And as be increased the inductance, the coupling coefficient of antenna is over coupled. This means that it can be electrically controlled the resonant frequency and input impedance of antenna by inductance and minimized the mismatch loss. Size reduction of 10% for PIFA is obtained without any major modifications of antenna elements. For the frequency range from 1650 to 1830MHz, reduction of the measured antenna gain is within 0.93dB as varying the value of inductance from 0 to 3.3nH.

Preparation of Zirconia Nanocrystalline Powder by the Hydrothemal Treatment at low Temperature (수열법에 의한 저온 결정형 지르코니아 나노 분말의 제조)

  • Noh, Hee-Jin;Lee, Jong-Kook;Seo, Dong-Seok;Hwang, Kyu-Hong
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.3
    • /
    • pp.308-314
    • /
    • 2002
  • The nanocrystalline zirconia powder was synthesized from the zirconium hydroxide precipitate by hydrothermal process with the reaction temperature range 100∼250$^{\circ}$C, reaction time 1∼48 hours and additive concentration 1, 5 N NaOH solutions. The lower hydrothermal treatment temperature, the inner spherical tetragonal zirconia was synthesized. The fraction of monoclinic phase zirconia with rod shape increased with increasing the hydrothermal treatment temperature. As the concentration of the NaOH solution increases, the synthesized particle in breadth and length increased; breadth and length ratio decreased. In the case of the low concentration of NaOH solution, however, the particle length became relatively larger than its breadth resulting in the rod-shaped particles with bigger aspect ratio.

Study of Monitoring Parameters for Coherent Beam Combination through Fourier-domain Analysis of the Speckle Image (스펙클 이미지의 푸리에 공간 분석을 통한 결맞음 빔결합 상태 모니터링 변수 도출)

  • Park, Jaedeok;Choe, Yunjin;Yeom, Dong-Il
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.6
    • /
    • pp.268-273
    • /
    • 2020
  • We analyze the characteristics of the coherent beam combination of lasers by monitoring the speckle pattern of the beam reflected from a scattering medium. Three collimated laser sources with high coherence are focused on a scattering target using a lens, and we then examine the speckle pattern of the returned beam in the Fourier domain. We observe that the size of the speckle pattern changes, depending on the focused-beam size or degree of spatial overlap of the three beams. Furthermore, through Fourier-domain analysis of the speckle pattern we obtain the monitoring variable to qualify the efficiency of the coherent beam combination.

Study on the channel of bipolar plate for PEM fuel cell (고분자 전해질 연료전지용 바이폴라 플레이트의 유로 연구)

  • Ahn Bum Jong;Ko Jae-Churl;Jo Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.2 s.23
    • /
    • pp.15-27
    • /
    • 2004
  • The purpose of this paper is to improve the performance of Polymer electrolyte fuel cell(PEMFC) by studying the channel dimension of bipolar plates using commercial CFD program 'Fluent'. Simulations are done ranging from 0.5 to 3.0mm for different size in order to find the channel size which shoves the highst hydrogen consumption. The results showed that the smaller channel width, land width, channel depth, the higher hydrogen consumption in anode. When channel width is increased, the pressure drop in channel is decreased because total channel length Is decreased, and when land width is increased, the net hydrogen consumption is decreased because hydrogen is diffused under the land width. It is also found that the influence of hydrogen consumption is larger at different channel width than it at different land width. The change of hydrogen consumption with different channel depth isn't as large as it with different channel width, but channel depth has to be small as can as it does because it has influence on the volume of bipolar plates. however the hydrogen utilization among the channel sizes more than 1.0mm which can be machined in reality is the most at channel width 1.0, land width 1.0, channel depth 0.5mm and considered as optimum channel size. The fuel cell combined with 2cm${\times}$2cm diagonal or serpentine type flow field and MEA(Membrane Electrode Assembly) is tested using 100W PEMFC test station to confirm that the channel size studied in simulation. The results showed that diagonal and serpentine flow field have similarly high OCV and current density of diagonal (low field is higher($2-40mA/m^2$) than that of serpentine flow field under 0.6 voltage, but the current density of serpentine type has higher performance($5-10mA/m^2$) than that of diagonal flow field under 0.7-0.8 voltage.

  • PDF

Fabrication of high purified zirconium dioxide (ZrO2) and stabilized zirconia (TZP: tetragonal zirconia polycrystal) powders (고순도 산화지르코늄(ZrO2) 및 안정화 지르코니아 (TZP: tetragonal zirconia polycrystal) 분말제조)

  • 최의석
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1996.06b
    • /
    • pp.55-85
    • /
    • 1996
  • 지르코니아 분말은 ZrO2 결정상이 온도변화에 따라 부피변화를 수반하는 상전이변태를 나타낸다. 단사정 ZrO2가 110$0^{\circ}C$에서는 정방정으로, 2$700^{\circ}C$ 내외에서는 입방정으로 결정구조가 가역적으로 변한다. 이 ZrO2에 금속산화물을 고용시키면 형석 (CaF2:Florite)형의 입방정 결정구조가 실온에서도 안정하게 존재하게 된다. 안정화제 산화물은 caO, MgO등 2가 산화물외에 3가 또는 4가의 금속산화물로서 Sc2O3, Y2O3, Sm2O3, Nd2O3, Gd2O3, Y2O3, CeO2 등이며 이들은 금속이온의 원자가가 변하기 쉬운 희토류 산화물이다. 안정화 지르코니아는 형석형 결정구조이며 결정화학적으로 보면 금속양이온이 산소이온에 대해서 정육면체형의 8배위를 하고 있다. 이때 이온반경비(양이온/음이온)에 따라 Zr+4자리와 O-2자리의 격자위치와 모양이 형성되므로 비틀어진 정육면체구조이건 이상적인 정육면체 형석구조를 이룬다. 이는 지르코니아의 결정상의 2상-3상인 부분안정화 지르코니아다결정체(PSZ : partially stabilized zirconia)이거나 단일상-2상인 정방정 지르코니아다결정체(TZP : tetragonal zirconia polycrystal)의 결정구조를 가지는데 기인한다. PSZ는 주로 MgO, CaO를 안정화제로 고용시켜 입방정 영역에서 소결하고 이를 다시 입방정과 정방정의 상 영역에서 열처리하여 입방정 입자내부에 정방정을 석출 형성시킨 것이며 TZP는 Y2O3 및 CeO2를 고용시켜 PSZ와 다르게 일반적인 상압소결한 정방정 결정상의 미립자이다. 산화지르코늄 분말은 지르콘사에서 열분해시킨 지르코늄소결.융해괴(caustic fusion clinker)를 산처리하여얻어진 지르코늄산용액(zirconyl acid solution : cloride, sulfide, nitride 등)으로부터 제조된다. 고순도 산화지르코늄은 용액 결정석출법에 의해 ZrOCl2.8H2O, 5ZrO2.3SO3.15H2O, ZrO(NO3)2.xH2O 등의 지르코늄 수화물만을 재결정화시킨 것으로부터 얻을 수 있으며 이 지르코늄염 수용액으로부터 입자미세구조를 효과적으로 제어하여 산화지르코늄 및 안정화 지르코니아 분말제조가 가능하다. 안정화 지르코니아 분말은 ZrO2와 안정화산화물의 고용을위하여 가열처리를 필요로 하며 일정온도에서 최적상태로 숙성하므로서 2가지 상(phase) 이상의 고용체를 가지게 된다. 안정화 지르코니아 분말은 고용처리온도를 낮추고 효과적으로 생성시키기 위해서는 지르코늄 및 안정화제염을 혼합하고 습식 직접합성하여 저온에서 고용체의 합해진상 영역을 생성시키는 것이다. 이는 지르코니아 원료분말의 미세구조를 제어하므로서 가능하며 이때 화학성분조성과 크기형태가 균일하게 분포된 입자분말을 얻을 수 있다.

  • PDF

Development of Quality Control Method for Visibility Data Based on the Characteristics of Visibility Data (시정계 자료 특성을 고려한 시정계 자료 품질검사 기법 개발)

  • Oh, Yu-Joo;Suh, Myoung-Seok
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_1
    • /
    • pp.707-723
    • /
    • 2020
  • In this study, a decision tree type of quality control (QC) method was developed to improve the temporal-spatial representation and accuracy of the visibility data being operated by the Korea Meteorological Administration (KMA). The quality of the developed QC method was evaluated through the application to the 3 years (2016.03-2019.02) of 290 stations visibility data. For qualitative and quantitative verification of the developed QC method, visibility and naked-eye data provided by the KMA and QC method of the Norwegian Meteorological Institute (NMI) were used. Firstly, if the sum of missing and abnormal data exceeds 10% of the total data, the corresponding point was removed. In the 2nd step, a temporal continuity test was performed under the assumption that the visibility changes continuously in time. In this process, the threshold was dynamically set considering the different temporal variability depending on the visibility. In the 3rd step, the spatial continuity test was performed under the assumption of spatial continuity for visibility. Finally, the 10-minute visibility data was calculated using weighted average method, considering that the accuracy of the visibility meter was inversely proportional to the visibility. As results, about 10% of the data were removed in the first step due to the large temporal-spatial variability of visibility. In addition, because the spatial variability was significant, especially around the fog area, the 3rd step was not applied. Through the quantitative verification results, it suggested that the QC method developed in this study can be used as a QC tool for visibility data.

Diagnosis and Treatment of Brown Tumor (Brown 종양의 진단 및 치료)

  • Cho, Yong Jin;Cho, Yung Min;Na, Seung Min;Jung, Sung-Taek
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.54-61
    • /
    • 2020
  • Purpose: Brown tumor is a tumor-like disease that can occur as a linked disease of hyperparathyroidism which can causes osteoporosis, osteitis fibrosa cystica, pathologic fractures. Brown tumor has been reported as a case report, but there is no comprehensive report on the exact diagnosis and principle of management for osseous lesion. The purpose of this study is to report the treatment and results of osseous lesions through 5 cases. Materials and Methods: From February 2004 to May 2015, five cases of Brown tumor were diagnosed in Chosun University Hospital and Chonnam National University Hospital orthopedic department. Medical records and radiographs were reviewed retrospectively. Parathyroid tumors were surgically removed, and surgical treatment and observation were performed for orthopedic osseous lesions. Results: The mean length of the long axis of the symptomatic osseous lesion was 6.2 cm (4.5-9.0 cm). An average of 7.6 (range, 3 to 14) of high uptake osseous lesion showed in whole body bone scan. The absolute value, T-score and Z-score of the vertebrae and proximal femur were adequate for diagnosis of osteoporosis using dual energy X-ray absorptiometry bone mineral density at diagnosis and recovered to normal at the last follow-up. In laboratory tests, serum concentrations of total calcium, ionized calcium, inorganic phosphorus, serum alkaline phosphatase, and parathyroid hormone were helpful to diagnosis and normalized upon successful removal of parathyroid adenoma or cancer. Conclusion: For accurate diagnosis of Brown tumor, it should be accompanied by systemic examination as well as clinical symptoms, laboratory tests and radiologic examination for osseous lesions. And a good prognosis can be expected if the hyperparathyroidism is treated together with the comprehensive treatment of osseous lesions.