• Title/Summary/Keyword: 2nd-Order plus dead time

Search Result 2, Processing Time 0.016 seconds

Design of the Controllers for the Improved Response of Time Delay Systems (시간지연 시스템의 응답특성 개선을 위한 제어기 설계)

  • Lee, Suk-Won;Yang, Seung-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.15-19
    • /
    • 2005
  • The practical control problems for the lime-delay system is considered. The delay-free characteristics of the Smith Predictor is available only when both the process and it's model are exactly matched. So it does not used widely in practical industrial processes. In this paper, using the 2nd-order plus dead time model in place of the plant model of the Smith Predictor, the proposed controller shows the improved performance in case of the very long time delay. And the range of integral constant of the PI controller is also proposed.

Improved Performance of the Time-Delay Systems Using the Approximated End-Order Plus Dead Time Model (근사화된 2계 모델을 이용한 시간지연을 갖는 제어시스템의 성능개선)

  • Lee, Kyu-Yong;Yang, Seung-Hyun;Hur, Myung-Joon;Lee, Suk-Won
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.518-520
    • /
    • 1999
  • The practical control problems for the time-delay system is considered. The delay-free characteristics of the Smith Predictor is available only when both the process and it's model are exactly matched. So it does not used widely in practical industrial processes. In this paper, using the 2nd-order plus deadtime model in place of the plant model of the Smith predictor, the proposed controller shows the improved performance in case of the very long time delay. And the range of integral constant of the PI controller is also proposed.

  • PDF