• Title/Summary/Keyword: 2D scanner

Search Result 403, Processing Time 0.025 seconds

A STUDY ON THE VOLUMES AND FORMS OF THE PALATE FOR DECIDUOUS AND PERMANENT DENTITION (유치열과 영구치열의 구개 형태에 관한 연구)

  • Yang, Yeon-Mi;Baik, Byeong-Ju;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.4
    • /
    • pp.696-706
    • /
    • 2003
  • The purpose of this study was to clarify the palatal forms through palatal curvatures of right to left, anterior to posterior direction, and difference of right and left palatal volumes in the primary and permanent dentition. Samples were consisted of normal occlusion of both dentition(50 males and 50 females each). Their upper plaster casts were used, measuring points were decided, through 3-dimensional laser scanning(3-D Laser Scanner, DS4060, LDI, U.S.A.), and fitting standard horizontal plane were made for measuring the height and sectioned volumes of palate. The results were as follows: 1. Palatal volume and height were greater at the right side of the palate in the primary and permanent dentition of male and female, but there was no significance. 2. Palatal height was greater in male compared to female, especially, there was significant difference at intercuspid, inter-second premolar area in the permanent dentition(P<0.05). 3. To the height of A-P direction of mid-palatal area, the highest point was 20mm in the primary dentition, 30mm in the permanent dentition from interdental papilla of central incisors. 4. Palatal height of inter-cuspid and inter-second premolar became shallow and broad, high and broad each, compared to inter-deciduous canine and inter-second deciduous molar.

  • PDF

A study on Broad Quantification Calibration to various isotopes for Quantitative Analysis and its SUVs assessment in SPECT/CT (SPECT/CT 장비에서 정량분석을 위한 핵종 별 Broad Quantification Calibration 시행 및 SUV 평가를 위한 팬텀 실험에 관한 연구)

  • Hyun Soo, Ko;Jae Min, Choi;Soon Ki, Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.20-31
    • /
    • 2022
  • Purpose Broad Quantification Calibration(B.Q.C) is the procedure for Quantitative Analysis to measure Standard Uptake Value(SUV) in SPECT/CT scanner. B.Q.C was performed with Tc-99m, I-123, I-131, Lu-177 respectively and then we acquired the phantom images whether the SUVs were measured accurately. Because there is no standard for SUV test in SPECT, we used ACR Esser PET phantom alternatively. The purpose of this study was to lay the groundwork for Quantitative Analysis with various isotopes in SPECT/CT scanner. Materials and Methods Siemens SPECT/CT Symbia Intevo 16 and Intevo Bold were used for this study. The procedure of B.Q.C has two steps; first is point source Sensitivity Cal. and second is Volume Sensitivity Cal. to calculate Volume Sensitivity Factor(VSF) using cylinder phantom. To verify SUV, we acquired the images with ACR Esser PET phantom and then we measured SUVmean on background and SUVmax on hot vials(25, 16, 12, 8 mm). SPSS was used to analyze the difference in the SUV between Intevo 16 and Intevo Bold by Mann-Whitney test. Results The results of Sensitivity(CPS/MBq) and VSF were in Detector 1, 2 of four isotopes (Intevo 16 D1 sensitivity/D2 sensitivity/VSF and Intevo Bold) 87.7/88.6/1.08, 91.9/91.2/1.07 on Tc-99m, 79.9/81.9/0.98, 89.4/89.4/0.98 on I-123, 124.8/128.9/0.69, 130.9, 126.8/0.71, on I-131, 8.7/8.9/1.02, 9.1/8.9/1.00 on Lu-177 respectively. The results of SUV test with ACR Esser PET phantom were (Intevo 16 BKG SUVmean/25mm SUVmax/16mm/12mm/8mm and Intevo Bold) 1.03/2.95/2.41/1.96/1.84, 1.03/2.91/2.38/1.87/1.82 on Tc-99m, 0.97/2.91/2.33/1.68/1.45, 1.00/2.80/2.23/1.57/1.32 on I-123, 0.96/1.61/1.13/1.02/0.69, 0.94/1.54/1.08/0.98/ 0.66 on I-131, 1.00/6.34/4.67/2.96/2.28, 1.01/6.21/4.49/2.86/2.21 on Lu-177. And there was no statistically significant difference of SUV between Intevo 16 and Intevo Bold(p>0.05). Conclusion Only Qualitative Analysis was possible with gamma camera in the past. On the other hand, it's possible to acquire not only anatomic localization, 3D tomography but also Quantitative Analysis with SUV measurements in SPECT/CT scanner. We could lay the groundwork for Quantitative Analysis with various isotopes; Tc-99m, I-123, I-131, Lu-177 by carrying out B.Q.C and could verify the SUV measurement with ACR phantom. It needs periodic calibration to maintain for precision of Quantitative evaluation. As a result, we can provide Quantitative Analysis on follow up scan with the SPECT/CT exams and evaluate the therapeutic response in theranosis.

3D Face Recognition using Projection Vectors for the Area in Contour Lines (등고선 영역의 투영 벡터를 이용한 3차원 얼굴 인식)

  • 이영학;심재창;이태홍
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.2
    • /
    • pp.230-239
    • /
    • 2003
  • This paper presents face recognition algorithm using projection vector reflecting local feature for the area in contour lines. The outline shape of a face has many difficulties to distinguish people because human has similar face shape. For 3 dimensional(3D) face images include depth information, we can extract different face shapes from the nose tip using some depth values for a face image. In this thesis deals with 3D face image, because the extraction of contour lines from 2 dimensional face images is hard work. After finding nose tip, we extract two areas in the contour lilies from some depth values from 3D face image which is obtained by 3D laser scanner. And we propose a method of projection vector to localize the characteristics of image and reduce the number of index data in database. Euclidean distance is used to compare of similarity between two images. Proposed algorithm can be made recognition rate of 94.3% for face shapes using depth information.

  • PDF

Engineering design process of tight-fit sportswear using 3D information of dermatomes and skin deformation in dynamic posture (동적자세와 피부분절을 이용한 기능성 밀착의복 제작 프로세스)

  • Kim, So-Young;Hong, Kyung-Hi
    • Korean Journal of Human Ecology
    • /
    • v.21 no.3
    • /
    • pp.551-565
    • /
    • 2012
  • The primary goal of this study was to provide a systematic methodology of utilizing 3D technology for tight-fit performance sportswear using information of skin deformation in various posture. Technical tools used in this study are Cyberware whole body scanner, RapidForm2004, 2C-AN 3D pattern development program, and YukaCAD. Analysis of the 3D skin deformation while knee joint was bent from $0^{\circ}$ to $60^{\circ}$ revealed that the length of dermatomes L4 was remained consistent during knee bending. Therefore, L4 was chosen as a major cutting line. To develop a highly ergonomic pattern, replicas of static and dynamic postures were developed and integrated using two methods, one is morphing method (Sqirlz Morph), and the other is AutoCAD. Experimental tight-fit garments called 'Derm-Mov Pattern' was designed using dematomes L4, L2, and inner line under knee and compared with four other patterns. As results, AutoCAD was appropriate as a integrating method of various postures. In wear test, 'Derm-Mov Pattern' was rated high (p < .001), in terms of pressure comfort especially around front crotch area. However, wear sensation was not signipicantly different in other area due to highly extensible property of materials. Pressure distribution was relatively even in these experimental garments.

Design of Three-dimensional Face Recognition System Using Optimized PRBFNNs and PCA : Comparative Analysis of Evolutionary Algorithms (최적화된 PRBFNNs 패턴분류기와 PCA알고리즘을 이용한 3차원 얼굴인식 알고리즘 설계 : 진화 알고리즘의 비교 해석)

  • Oh, Sung-Kwun;Oh, Seung-Hun;Kim, Hyun-Ki
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.6
    • /
    • pp.539-544
    • /
    • 2013
  • In this paper, we was designed three-dimensional face recognition algorithm using polynomial based RBFNNs and proposed method to calculate the recognition performance. In case of two-dimensional face recognition, the recognition performance is reduced by the external environment like facial pose and lighting. In order to compensate for these shortcomings, we perform face recognition by obtaining three-dimensional images. obtain face image using three-dimension scanner before the face recognition and obtain the front facial form using pose-compensation. And the depth value of the face is extracting using Point Signature method. The extracted data as high-dimensional data may cause problems in accompany the training and recognition. so use dimension reduction data using PCA algorithm. accompany parameter optimization using optimization algorithm for effective training. Each recognition performance confirm using PSO, DE, GA algorithm.

A Study on Optical Coherence Tomography System by Using the Optical Fiber (광섬유를 이용한 광영상단층촬영기 제작에 관한 연구)

  • 양승국;박양하;장원석;오상기;이석정;김기문
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.34-40
    • /
    • 2004
  • In this paper, we have studied the OCT(Optical Coherence Tomography) system which has been advantages of high resolution, 2-D cross-sectional images, low cost and small size configuration. The characteristics of light source determine the resolution and coherence length. The light source has a commercial SLD with a central wavelength of 1,285 ill11, 35.3 nm(FWHM). The optical delay line is necessary to make equal with the optical path length to scattered light or reflected light from a sample. In order to make equal the optical path length, the stage that is attached to a reference mirror is controled by a step motor. And the interferometer is configured with the Michelson interferometer by using a single mode fiber, and the scanner can be focused on the sample by using a reference ann Also, the 2-dimension cross-sectional images were measured with scanning the transverse direction of the sample by using a step motor. After detecting the internal signal of lateral direction, a scanner is moved to obtain the cross-sectional image of 2-dimension by using step motor. A photodiode, which has high detection sensitivity and excellent noise characteristics has been used. The detected small signal has a noise and interference. After filtering and amplifying the signal, the output signal is demodulated the waveform And then, a cross-sectional image is seen through converting this signal into a digitalized signal by using an AID converter. The resolution of the sample is about 30${\mu}{\textrm}{m}$, which corresponds to the theoretical resolution. Also, the cross-sectional images of onion cells were measured in real time scheme.

A Study of Roughness Measurement of Rock Discontinuities Using a Confocal Laser Scanning Microscope (콘포컬 레이저 현미경을 이용한 불연속면의 거칠기 측정 연구)

  • Byung Gon Chae;Jae Yong Song;Gyo Cheol Jeong
    • The Journal of Engineering Geology
    • /
    • v.12 no.4
    • /
    • pp.405-419
    • /
    • 2002
  • Fracture roughness of rock specimens is observed by a new confocal laser scanning microscope (CLSM; Olympus OLS1100). The wave length of laser is 488 nm, and the laser scanning is managed by a light polarization method using two galvano-meter scanner mirrors. The function of laser reflection auto-focusing enables us to measure line data fast and precisely. The system improves resolution in the light axis (namely z) direction because of the confocal optics. Using the CLSM, it is Possible to measure a specimen of the size up to $10{\;}{\times}{\;}10{\;}cm$ which is fixed on a specially designed stage. A sampling is managed in a spacing $2.5{\;}\mu\textrm{m}$ along x and y directions. The highest measurement resolution of z direction is $10{\;}\mu\textrm{m}$, which is more accurate than other methods. Core specimens of coarse and fine grained granite are provided. Fractures are artificially maneuvered by a Brazilian test method. Measurements are performed along three scan lines on each fracture surface. The measured data are represented as 2-D and 3-D digital images showing detailed features of roughness. Line profiles of the coarse granites represent more frequent change of undulation than those of the fine granite. Spectral analyses by the fast Fourier transform (FFT) are performed to characterize the roughness data quantitatively and to identify influential frequency of roughness. The FFT results suggest that a specimen loaded by large and low frequency energy tends to have high values of undulation change and large wave length of fracture roughness.

Sensor Model Design of Range Sensor Based Probabilistic Localization for the Autonomous Mobile Robot (자율 주행 로봇의 확률론적 자기 위치 추정기법을 위해 거리 센서를 이용한 센서 모델 설계)

  • Kim, Kyung-Rock;Chung, Woo-Jin;Kim, Mun-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.27-29
    • /
    • 2004
  • This paper presents a sensor model design based on Monte Carlo Localization method. First, we define the measurement error of each sample using a map matching method by 2-D laser scanners and a pre-constructed grid-map of the environment. Second, samples are assigned probabilities due to matching errors from the gaussian probability density function considered of the sample's convergence. Simulation using real environment data shows good localization results by the designed sensor model.

  • PDF

ABSOLUTE SPECTROPHOTOMETRY OF SOME GALACTIC WOLF-RAYET STARS: EFFECTIVE TEMPERATURES AND BOLOMETRIC CORRECTIONS

  • Woo, Jong-Ok
    • Journal of The Korean Astronomical Society
    • /
    • v.21 no.1
    • /
    • pp.57-65
    • /
    • 1988
  • The absolute measurements of fluxes in the region ${\lambda}{\lambda}3,100-8,090\;{\AA}$ emitted in the visible continua of some galactic Wolf-Rayet stars are presented. These observations were made by a two-channel scanner which was built up cooperatively by the Observatoire of Lyon and the Laboratoire d'Astronomie Spatiale. The fluxes, dereddened from those data, were combined with IUE and ANS ultraviolet measurements. These fluxes were compared with those of LTE plane paralleled model atmospheres of Kurucz (1979) and were also integrated in order to derive effective temperatures and bolometric corrections for the program stars. The derived effective temperatures and bolometric corrections for the stars were in the range of $25,000\;K{\sim}32,700\;K$, and of $-2.5\;mag.{\sim}-3.7\;mag.$, respectively.

  • PDF

The Characteristics of Water-Jet Chipping Performance & Geometry of Chipping Surface (수압파쇄에 의한 치핑성능 및 치핑면의 기하학적 특성)

  • Jang Bong Seok;Im Eun Sang;Woo Gi Hong;Park Seo Kyu;Kim Jin Woo;Yoo Young Ha
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.343-346
    • /
    • 2005
  • This study makes the performance evaluation of water-jet chipping through analysis of ruggedness of chipping surface. The ruggedness is mapped by 3D Laser Scanner and the results are also compared with the chipping surface by mechanical chipping. And the details of in-situ works is investigated for increasing interface adhesion between existing concrete and repairing mortar. Water-jet has good operation efficiency which is up $60m^2$ per hour when the chipping depth is 7cm and also has a large ruggedness about 1.65.

  • PDF