• Title/Summary/Keyword: 2D rectangular cylinder

Search Result 16, Processing Time 0.021 seconds

Evaluation on Noise Characteristics by Field Application of Improved Rumble Strip (개선된 럼블스트립의 현장적용에 따른 사후 소음특성 평가)

  • An, Deok-Soon;Suh, Young-Chan;Son, Hyeon-Jang;Lee, Jae-Jun;Eom, Byeong-Sik
    • International Journal of Highway Engineering
    • /
    • v.15 no.6
    • /
    • pp.33-39
    • /
    • 2013
  • PURPOSES : This research investigates traffic noise characteristics as change the transverse rumble strips shape from rectangular to cylinder at toll plaza of highway. METHODS : The traffic noise was investigated at two different places at toll plaza of highway. One is modified grooving, another is employed cylinder shape of TRS instead of rectangular shape of TRS. A measurement of traffic noise was conducted at same location and time period. The traffic volume information was gotten from office of highway office and vehicle speed was measured by speed measuring device. The traffic noise measurement was conducted from 13:00 to 23:00 and by pass-by method. Also, the traffic noise was measured behind noise barrier. Various distance from noise barrier(7.5m, 30m, 50m) and different heights(1.2m, 3m, and 5m) were parameter for measurement of traffic noise in this study. RESULTS : The class 1 vehicle was contributed from traffic volume which was increased 1,500. However, the distribution of traffic speed didn't change compare to previous investigated period. From this study, It was found that the external traffic noise was changed as function of geometric shape of TRS. The external noise from modified grooving was less than 1.2dB(A) of the current TRS. A difference of traffic noise was 20dB(A) before and after barrier. It came from a noise barrier effect as reduction of traffic noise. According to investigate a traffic noise distribution near barrier, there is similar noise characteristic as function of height at 7.5m distance from noise barrier. Also, There is no different traffic noise between 30m and 50m from source of the noise of sound barrier. CONCLUSIONS : Based on this traffic noise investigation result, there is a clear characteristic difference as changed TRS shape. The traffic noise was reduced by changed TRS shape. Specially, traffic noise was decreased although the traffic volume was increase for same investigation time and period. It is implied that cylinder type of TRS significantly reduces the traffic noise. The specification of various TRS will be studied in the future.

A Study of Spectral Domain Electromagnetic Scattering Analysis Applying Wavelet Transform (웨이블릿을 이용한 파수영역 전자파 산란 해석법 연구)

  • 빈영부;주세훈;이정흠;김형동
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.3
    • /
    • pp.337-344
    • /
    • 2000
  • The wavelet analysis technique is applied in the spectral domain to efficiently represent the multi-scale features of the impedance matrices. In this scheme, the 2-D quadtree decomposition (applying the wavelet transform to only the part of the matrix) method often used in image processing area is applied for a sparse moment matrix. CG(Conjugate-Gradient) method is also applied for saving memory and computation time of wavelet transformed moment matrix. Numerical examples show that for rectangular cylinder case the non-zero elements of the transformed moment matrix grows only as O($N^{1.6}$).

  • PDF

A Study on the Improvement of the Directivity for Rectangular Microstrip Patch Array Antennas Conformed to a Cylindrical Surface (원통면에 정합-배열된 장방형 마이크로스트립 패치 안테나의 지향성 개선을 위한 연구)

  • 고광태;구연건
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.5 no.2
    • /
    • pp.46-54
    • /
    • 1994
  • In this paper, an analysis and design method is proposed, which is to improve the directivity of microstrip array antennas conformed to a cylindrical surface. In the case of forming an arc-array in the circumferential direction on a circula-cylinder surface, the circular-cylinder can be approximated to a polygonal-pillar and on each pillar-planes the sub-arrays, Dolph-Tschebyscheff array and uniform array with a beam steered in the desired direction, would make a sharp directivity for the total cylin- drical array antenna. And the radiation pattern according to the type of its sub arrays is analyzed and compared using the cylindrical-cavity codel. A cylindrical microstrip array antenna, with 12 elements and uniform arra as a sub-array which have an equal distance$\lambda_0$/2between the elements, is manufactured and conformed to a cylinder with radius of 6 The measured data of side lobe level, HPBW and FNBW are - 13dB, $9^{\circ}$, and $15{\circ}$, ,respectively. This result shows a good improvement on the directivity comparing with a linear array.

  • PDF

Determination of the Strouhal number based on the aerodynamic behavior of rectangular cylinders

  • Choi, Chang Koon;Kwon, Dae Kun
    • Wind and Structures
    • /
    • v.3 no.3
    • /
    • pp.209-220
    • /
    • 2000
  • The Strouhal number is an important nondimensional number which is explanatory of aerodynamic instability phenomena. It takes on the different characteristic constant value depending upon the cross-sectional shape of the body being enveloped by the flow. A number of investigations into this subject, especially on the drag test, surface pressure test and hot-wire test, have been carried out under the fixed state of the body in the past. However, almost no investigations concerning the determination of the St on wind-induced vibration of the body have been reported in the past even though the aerodynamic behavior of the body is very important because the construction of wind-sensitive structures is recently on the sharp increase. Based on a series of wind tunnel tests, this paper addresses a new method to determine the Strouhal number of rectangular cylinder in the uniform flow. The central idea of the proposed method is that the Strouhal number can be obtained directly by the aerodynamic behaviors of the body through wind-induced vibration test. The validity of proposed method is evaluated by comparing with the results obtained by previous studies in three B/Ds at attack angle $0^{\circ}$ and a square cylinder with various attack angles. The values and trends of the proposed Strouhal numbers are in good agreements with values of previous studies. And also, the Strouhal numbers of B/D=1.5 and 2.0 with various attack angles are obtained by the proposed method and verified by other method. This proposed method is as good as any other previous methods to obtain the Strouhal number.

An Application of the Localized Finite Element Method to Two-dimensional Free Surface Wave Problems (2차원 자유표면파 문제에서의 국소 유한요소법의 응용)

  • Hyun-Kwon,Kil;K.J.,Bai
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.22 no.3
    • /
    • pp.9-18
    • /
    • 1985
  • The numerical calculation for solving boundary-value problem related to potential flows with a free surface is carried out by application of the localized finite element method. Only forced motion of 2-D body in infinitely deep fluid is considered, although this schemes is equally applicable to any first order time-harmonic problems of similar nature. The infinite domain of the fluid is separated into the inner flow field and the outer flow field with common inter-surface boundary. The finite element method is applied to obtain the solution in the inner flow field and the Green functions are utilized to represent the solution in the outer flow field. At the inter-surface boundary, the continuity of the value of potential and the normal derivative of the potential(i.e. matching condition) is conserved. The present method has better computational efficiency than the previous LFEM and the integral equation method of Frank. This enhanced computational efficiency is presumably due to the fact that the present method gives a symmetric coefficient matrix and requires less computational time in calculating the influence coefficient matrix of Green function than the integral equation method. And the irregular frequency desen't exist because the uniqueness of the solution is assured by the such that the exact free surface condition is satisfied on the boundary of the localized finite element region(i.e. inner region). As an example of the above method, the hydrodynamic forces for the circular cylinder and the rectangular cylinders are calculated. In the computed results, the small number of singularity distribution segments($3{\sim}6$) give good result relative to Ursell's and Vugts'.

  • PDF

Quantitative Measurement of Soot concentration by Two-Wavelength Correction of Laser-Induced Incandescence Signals (2파장 보정 Laser-Induced Incandescence 법을 이용한 매연 농도 측정)

  • 정종수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.3
    • /
    • pp.54-65
    • /
    • 1997
  • To quantify the LII signals from soot particle of flames in diesel engine cylinder, a new method has been proposed for correcting LII signal attenuated by soot particles between the measuring point and the detector. It has been verified by an experiment on a laminar jet ethylene-air diffusion flame. Being proportional to the attenuation, the ratio of LII signal at two different detection wavelengths can be used to correct the measured LIIsignal and obtain the unattenuated LII signal, from which the soot volume fraction in the flame can be estimated. Both the 1064-nm and frequency-doubled 532-nm beams from the Nd : YAG laser are used. Single-shot, one-dimensional(1-D) line images are recorded on the intensified CCD camera, with the rectangular-profile laser beam using 1-mm-diameter pinhole. Two broadband optical interference filters having the center wavelengths of 647 nm and 400 nm respectively and a bandwidth of 10 nm are used. This two-wavelength correction has been applied to the ethylene-air coannular laminar diffusion flame, previously studied on soot formation by the laser extinction method in this laboratory. The results by the LII measurement technique and the conventional laser extinction method at the height of 40 nm above the jet exit agreed well with each other except around outside of the peaks of soot concentration, where the soot concentration was relatively high and resulting attenuation of the LII signal was large. The radial profile shape of soot concentration was not changed a lot, but the absolute value of the soot volume fraction around outside edge changed from 4ppm to 6.5 ppm at r=2.8mm after correction. This means that the attenuation of LII signal was approximately 40% at this point, which is higher than the average attenuation rate of this flame, 10~15%.

  • PDF