• 제목/요약/키워드: 2D position measurement

검색결과 188건 처리시간 0.032초

복합레진의 초기 동적 체적 중합수축의 실시간 측정 -새로운 측정장치의 개발에 대한 소고- (A NEW METHOD - REAL TIME MEASUREMENT OF THE INITIAL DYNAMIC VOLUMETRIC SHRINKAGE OF COMPOSITE RESINS DURING POLYMERIZATION)

  • 이인복
    • Restorative Dentistry and Endodontics
    • /
    • 제26권2호
    • /
    • pp.134-140
    • /
    • 2001
  • The polymerization shrinkage of composite resins is an important drawback although the composites have many advantages-more esthetic and conservative than metallic restoratives etc. The purposes of this research were to develop a new measurement method and to manufacture an instrument that can measure the initial dynamic volumetric shrinkage of composite resins during polymerization. The instrument was basically an electromagnetic balance that constructed with a force transducer using position sensitive photo detector(PSPD) and a negative feedback servo amplifier of proportional-derivative(PD) controller. The volumetric change of composites during polymerization was detected continuously as buoyancy change in distilled water by means of Archimedes's principle. It was converted to continuous electrical voltage signal in real time. The signal was properly conditioned and filtered and then it was stored in computer by a data acquisition(DAQ) board. By using this electronic instrument. the dynamic patterns of the polymerization shrinkage of eight commercial(Z-100, DenFil, AeliteFil, Z-250, P-60, SureFil, Synergy compact, and Tetric ceram) composite resins were measured and compared. The results were as follows. 1. From this project of developing instrument, the ability has been achieved that can acquire and process data of electrical signal transformed from various physical phenomenon by using temperature, displacement. photo. and force transducer. As a consequence, the instrumentation and measurement system used to analyze the physical characteristics of various dental materials in dental research field can be designed, manufactured and implemented in lab. 2. This instrument has some advantages. It was insensible to temperature change and could measure true dynamic volumetric shrinkage in real time without complicated process. It showed accuracy and high precision results with small standard deviation. 3. The polymerization shrinkage of composites was significantly different between brands and ranged from 2.47% to 3.89%, The order of polymerization shrinkage was as follows, in order of increasing shrinkage, SureFil, P60, Z250, Z100, Synergy compact. DenFil, Tetric ceram, and AeliteFil. 4. The polymerization shrinkage rate per unit time, dVol%/dt, showed that the instrument can provide an indirect research method for polymerization reaction kinetics.

  • PDF

소동물 실험용 다중코일형 자계발생장치의 설계 및 성능평가 (Design and Evaluation of a Magnetic Field Generator for Biological Experiment)

  • 명성호;이재복;김상범;추장희;이동일;김정부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.271-273
    • /
    • 2000
  • A magnetic field generator for small animal study was designed and constructed. For calculation of magnetic fields inside the cage, a three-dimensional calculation program was made. Using this, optimum electric current ratio and position of each coil were determined. Meanwhile, inductance of the generator was calculated for design of power supply. The field measurement results of the manufactured generator showed that the difference between maximum and minimum magnetic field at the living floor was less than 2%.

  • PDF

시간의존법에 의한 금속판재 성형한계변형률의 결정 (Determination of the Forming Limit Strain of Sheet Metals by the Time-dependent Method)

  • 김성곤;오태환;김진동;김형종
    • 소성∙가공
    • /
    • 제24권5호
    • /
    • pp.361-367
    • /
    • 2015
  • The forming limit diagram (FLD) is the most commonly used tool for evaluating of sheet metal formability in the manufacturing field as well as the finite element analysis (FEA)-based design process. Determination of the forming limits is considerably influenced by testing/measuring machines, techniques and conditions. These influences may cause a large scatter in FLD from laboratory to laboratory. Scatter is especially true when the ‘position-dependent method’, as is specified in most national and international standards, is used. In the current study a new ‘time-dependent method’ is proposed, which is to determine the forming limit strains more accurately and reasonably when producing a FLD from experimental data. This method is based on continual strain measurement during the test. The results are compared to those from the existing standardized methods.

자동 화물처리를 위한 실시간 팔레트 측정 방법 (Pallet Measurement Method for Automatic Pallet Engaging in Real-Time)

  • 변성민;김민환
    • 한국멀티미디어학회논문지
    • /
    • 제14권2호
    • /
    • pp.171-181
    • /
    • 2011
  • 본 논문에서는 자율주행 지게차에서 팔레트 화물을 자동 인식하여 운송할 수 있도록 하는 비전 기반의 팔레트 자세 및 위치 측정 방법을 제안한다. 일반적으로 3차원 측정에서는 스테레오 비전 기술이 사용되나, 제안한 방법에서는 지게차의 포크 캐리지에 설치한 한 대의 카메라만을 사용한다. 먼저 어떤 별도의 표식이 없는 팔레트의 자세를 측정하기 위해 영상 역투영 기법을 제시하였는데, 이 기법에서는 팔레트 앞면 영상에서의 두 특징 직선을 3차원 공간에서 주어진 축 중성으로 회전시킬 수 있는 가상평면에 역투영 시킨다. 가상평면에 역투영된 두 특정 직선이 평행하게 되면 그 때의 가상평면의 회전각이 팔레트의 자세를 나타낸다는 사실을 이용한다. 팔레트 위치 측정 방법에서는 역투영된 특징 직선 간의 거리와 팔레트 앞면에서의 실제 직선간 거리의 비율을 이용한다. 실제 팔레트 영상에 대한 실험을 통하여 제안된 방법의 타당성 및 실시간 실행 가능성을 보였다.

3차원 안면자동인식기의 Positioning 오차분석 (An Positioning Error Analysis of 3D Face Recognition Apparatus)

  • 곽창규;조용범;손은혜;유정희;고병희;김종원;김규곤;이의주
    • 사상체질의학회지
    • /
    • 제18권2호
    • /
    • pp.34-40
    • /
    • 2006
  • 1. Objectives We are going to develope 3D Face Recognition Apparatus to analyse the facial characteristics of the Sasangin. In the process, we should identify the recognition rate of the three dimensional position using this Apparatus. 2. Methods We took a photograph of calibrator($280{\times}400mm$) with interval of 20mm longitudinal direction of 10 times using 3D Face Recognition Apparatus. In the practice, we obtained 967 point to the exclusion of points deviating from the visual field of dual camera. And we made a comparison between measurement values and three dimensional standard values to calculate the errors. 3. Results and Conclusions In this test, the average error rate of X axis values was 0.019% and the maximum error rate of X axis values was 0.033%, the average error rate of Y axis values was 0.025% and the maximum error rate of Y axis values was 0.044%, the average error rate of Z axis values was 0.158% and the maximum error rate of Z axis values was 0.269%. This results exhibit much improvement upon the average error rate 1% and the maximum error rate 2.242% of the existing 3D Recognition Apparatus. In conclusion, we assessed that this apparatus was adaptable to abstract the facial characteristic point from three dimensional face shape in the mechanical aspects.

  • PDF

심매설 접지봉의 위치결정을 위한 대지구조 분석 방법들의 비교분석 (Comparison Analysis of Soil Structure Methods for Deciding the Position of a Deeply Driven Ground Rod)

  • 엄주홍;조성철;이태형;이복희
    • 조명전기설비학회논문지
    • /
    • 제21권7호
    • /
    • pp.37-45
    • /
    • 2007
  • 최근 뇌보호용 접지시스템 심매설 봉전극을 사용하는 경우가 늘고 있다. 심매설 봉전극의 경우에는 수직으로 깊게 봉전극을 시설하기 때문에 메시그리드 전극에 비해 장소의 제약을 덜 받는 장점이 있지만 국지적인 대지저항률에 의해 접지임피던스가 크게 변동하므로 설계시에 세밀한 대지구조의 분석이 필요하다. 기존의 Wenner법에 의한 대지저항률 측정은 널리 사용되는 방법이지만 국지적인 대지저항률의 변화를 알아내기가 불가능하였고 또한 겉보기 대지저항률로 측정결과가 나타나므로 정확한 깊이를 예측하기가 어렵다. 따라서 본 연구에서는 96채널 측정설비를 이용하여 대지구조를 2-D 이미지로 분석하였으며, 뇌보호용 심매설 전극을 효과적으로 설계하기 위해 국지적인 대지저항률 변동 및 대지층 깊이의 분석을 시도하였다. 대지저항률의 2-D 이미지 분석은 Wenner alpha법, Dipole-dipole법, Schlumberger법을 사용하였으며, 분석결과를 토대로 기존의 Wenner 1-D법으로 측정한 결과를 CDEGS로 분석한 대지구조와 비교하였다.

지능형 맥진기 구현 (Implementation of Intelligence Pulse Wave Detection System)

  • 홍유식;유준상;장세진;선승호;이우범;남동현;유문성;최명복;이상석
    • 한국인터넷방송통신학회논문지
    • /
    • 제13권2호
    • /
    • pp.245-254
    • /
    • 2013
  • 동양 의학에서는 맥파를 분석해서 많은 질병을 분류하고 치료하고 있다. 그러나 현재까지 맥파를 분석하는 방법은 매우 주관적인 방법을 사용하기 때문에 신뢰도가 떨어지는 문제점이 발생한다. 뿐만 아니라, 기존 맥진기의 문제점으로는 요골동맥에 정확하게 맥진 센서가 위치하지 못하기 때문에 측정 위치에 따라 측정결과가 상이하고 측정절차에 매우 민감하여 높은 재현성을 실현 못하고 있는 실정이다. 본 논문에서는 이러한 문제점을 해결하기 위해서 홀센서를 이용한 휴대용 맥진기를 이용해서 실맥 및 허맥을 분석 하는 연구 결과를 제안하였다. SPSS 통계 기법으로 분석한 실맥 및 허맥 최종 분석결과, 95% 신뢰도 구간에서 N.time(절흔점 시간) 및 S.amp (상승파형 크기) 평균치가 유의성이 있음을 입증하였다.

자동차 점화계통에서 발생된 전자파 잡음의 측정 및 통계적 모형 (Measurements and Statistical Modeling of Ignition Noise from Vehicle)

  • 김종호;윤현보;백락준;우종우
    • 한국전자파학회논문지
    • /
    • 제8권4호
    • /
    • pp.390-402
    • /
    • 1997
  • 자동차의 점화계통에서 발생하는 전자파 잡음을 측정하고 통계확률적인 방법을 이용하여 모델링을 하였다. 낮은 크기의 잡음도 측정이 가능하도록 수신기와 3축 안테나의 사이에 저잡음증폭기와 대역통과필터를 연결 구성하고, 800 MHz 대역의 진폭확률분포(APD)와 펄스간격분포(PSD)를 측정하였다. 측정된 APD 곡선을 3개(A급) 또는 6개(B급)의 변수로 모형화하였으며, 변수의 최적치를 쉽게 계산할 수 있는 합성근사화 알고리즘을 사용하였다. 진폭확률분포에 관한 모형변수를 추출함으로써 전자파환경의 데이터 베이스화가 가능하며, 송.수신기의 출력 및 감도의 마진 결정에 기초적인 자료로 이용이 가능하다.

  • PDF

넓은 덕트 단면내의 음원 분포 규명 (Identification of the Sectional Distribution of Sound Source in a Wide Duct)

  • 허용호;이정권
    • 한국음향학회지
    • /
    • 제33권2호
    • /
    • pp.87-93
    • /
    • 2014
  • 덕트 내 음원 면에서의 음압과 입자 속도분포를 상세히 알 수 있다면, 주된 소음원들의 위치와 강도를 분석하여 전파특성을 잘 이해할 수 있고, 이에 따라 저소음화 설계에 유용한 정보로 활용가능하다. 이를 위한 기존의 방법들은 대개 단면상 위치와 무관한 일정 변수로 나타내는 제한점이 있다. 본 논문에서는 음원의 단면 분포를 높은 공간분해능으로 관찰할 수 있는 방법에 대해 연구하였다. 모드 합성법을 기반으로 감쇠파의 영향과 근접장 측정을 포함하는 행렬식을 유도하였으며, 컴프레션 드라이버에 의해 일부 단면이 가진된 유동이 없는 덕트 시스템에서 검증하였다. 감쇠파모드 개수의 증가에 따라 음압 스펙트럼을 더욱 정확하게 근사화 할 수 있었으며, 26개의 감쇠파 모드를 포함한 수렴 결과로부터 관심 헬름홀쯔 수 영역에서 -25 dB 이하의 오차로 예측할 수 있었다. 수렴된 모드 진폭들을 이용하여 kR = 1에서 음원 면에서의 음원변수 분포를 관찰한 결과, 실제 음원이 설치된 국소 위치에서 높은 음압과 입자 속도 값을 분명히 나타내는 것을 보였다. 또한, 감쇠 모드의 역추산시에 정규화기법을 도입하여, 과결정된 반경방향 모드에 의해 발생된 무의미한 피크들을 효과적으로 제거할 수 있었다.

웨어러블 근전도 디바이스 결합형 스마트의류 개발 및 성능평가 (Development and Evaluation of Wearable Smart Clothing for Combined EMG Devices)

  • 이소정;김혜림;정원영
    • 한국의류산업학회지
    • /
    • 제25권2호
    • /
    • pp.210-220
    • /
    • 2023
  • Recently, smart wearable products, including electromyography (EMG) measurement devices and clothing, have been developed to monitor users' exercise levels, muscle activation, and muscle balance more effectively during fitness activities. However, technical and socioeconomic barriers, such as flexibility and durability, still pose challenges in terms of comfort, ease of wear, and wearability of smart clothing, which includes devices and circuits. To address these issues, this study developed a wearable EMG device integrated with clothing to collect valid EMG signals from desired muscles while maintaining comfort, functionality, and ease of wear. After deriving a combined structure that could stably position the wearable device within the clothing, a prototype was manufactured and evaluated for fit, compression, comfort, and exercise comfort test by ten participants (height = 176.2 cm, weight = 76.4 kg, chest circumference = 101.2 cm). The study found that the prototype had smaller circumferences around the chest, waist, and abdomen compared to commercial products, resulting in lower ratings for wearing comfort and ease of wear. However, the prototype received high ratings for fitting, pressure, and the exercise comfort test. Valid signals were obtained when the EMG device was combined to the prototype for the rectus femoris muscle, indicating stable positioning of the device during exercise.