• 제목/요약/키워드: 2D moving target

검색결과 73건 처리시간 0.028초

Compact and versatile range-finding speedometer with wide dynamic range

  • Shinohara, Shigenobu;Pan, Derong;Kosaka, Nozomu;Ikeda, Hiroaki;Yoshida, Hirofumi;Sumi, Masao
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.158-161
    • /
    • 1995
  • A new laser diode range-finding speedometer is proposed, which is modulated by a pair of positive and negative triangular pulse current superimposed on a dc current. Since a target velocity is directly obtained form a pure Doppler beat frequency measured during the non-modulation period, the new sensor is free from the difficulties due to the critical velocity encountered in the previous sensor. Furthermore, the different amplitude of the two triangular pluses are so adjusted that the measurable range using only one laser head is greatly expanded to 10cm through 150cm, which is about two times that of the previous sensor. The measurement accuracy for velocity of .+-.6mm/s through .+-.20mm/s and for range is about 1%, and 2%, respectively. Because the new sensor can be operated automatically using a microcomputer, it will be useful for application of a 3-D range image measurement of a slowly moving object.

  • PDF

PFA와 CDT 알고리즘을 이용한 2차원 ISAR 영상 생성 (2D ISAR Imaging using PFA and CDT Algorithms)

  • 유지희
    • 한국전자파학회논문지
    • /
    • 제15권9호
    • /
    • pp.906-913
    • /
    • 2004
  • 레이다 데이터로부터 ISAR(Inverse Synthetic Aperture Radar) 영상을 생성 할 때 가장 보편적으로 사용되는 것이 FFT 알고리즘이다. FFT 알고리즘을 넓은 방위각 데이터에 적용할 때는 MTRC(Moving Through Resolution Cell) 현상으로 영상의 번짐이 발생하는데 이를 보정하기 위하여 polar formatting 기법을 적용한다. 그러나 polar formatting도 적용할 수 있는 각도의 한계가 존재하며 만약 지나치게 넓을 경우 polar formatting을 적용하여도 원하는 영상을 얻을 수 없게 된다. 이 논문에서는 ISAR 영상 생성시 내삽법을 사용하는 polar formatting기법과 polar formatting의 단점인 내삽법을 사용하지 않는 CDT(Coherent Doppler Tomography) 기법을 비교하여 각각의 장단점을 분석하였다.

주파수 변조 연속파를 이용한 레벨 측정 시스템 개발에 관한 연구 (A Study on the Development of Level Sensor using Frequency Modulated Continuous Wave)

  • 박동국;한태경;박인용;윤천수
    • 한국항해항만학회지
    • /
    • 제28권6호
    • /
    • pp.497-501
    • /
    • 2004
  • 본 논문은 주파수 변조 연속파 레이더를 사용하여 화물 선박의 탱크의 내용물의 깊이를 측정하는 레벨 센서의 개발에 관한 것이다. 사용 주파수는 10∼11 GHz를 이용하였으며, 테스트용 물체는 RCS가 $0.8\textrm{m}^2$인 도체판을 사용하였다. 실험은 연구실 내부와 운동장에서 하였으며, 스윕 주기가 100ms, 안테나 이득이 약 22dBi인 사각형 혼 안테나를 사용하여 약 8 dBm의 신호를 안테나에 인가하여 40m 까지 물체를 움직이며 비트주파수를 측정하여 이론치와 비교하였다. 실험치와 이론치가 잘 일치하였으나 전압제어 발진기의 비선형으로 인해 분해능이 약 10cm 정도로 측정되었다.

팬/틸트 제어기반의 스데레오 카메라의 기하학적 정보를 이용한 새로운 높이 추정기법 (A New Height Estimation Scheme Using Geometric Information of Stereo Camera based on Pan/tilt control)

  • 고정환;김은수
    • 한국통신학회논문지
    • /
    • 제31권2C호
    • /
    • pp.156-165
    • /
    • 2006
  • 본 논문에서는 지능적인 보안 시스템 구현의 새로운 접근 방식으로, 인공지능형 시각 시스템에 기반한 팬/틸트 탑재형 스테레오 카메라의 기하학적 정보를 이용한 사람 키 높이 추정기법을 제안하였다. 제안된 시스템에서는 먼저, 스데레오 카메라에서 입력된 영상으로 부터 YCbCr 컬러 모델과 위상형 상관 기법을 사용하여 표적 얼굴영역의 중심좌표를 검출한 다음, 지능형 시각 시스템에 기반한 팬/틸트 탑재형 스테레오 카메라의 능동적인 제어각도 산출을 통해 표적의 다양한 변화에 관계없이 표적의 3차원 좌표를 실시간적으로 검출하고, 이를 통한 표적 대상의 적응적인 신체 크기 추정을 수행하였다. 각기 다른 신장을 가진 3사람의 다양한 이동경로를 가진 480 프레임의 테스트용 스테레오 영상을 사용한 실험 결과, 표적의 추정된 신체 크기값 역시 계산치 및 측정치 사이의 표준편차가 평균 1.03의 작은 값으로 유지됨은 물론, 제안된 시스템에서 계산된 좌표값과 실제 실험대상으로 참여한 사람의 정확한 실제 위치와의 차이 역시 평균 1.2cm 미만의 오차와 전체적으로 1.18$\%$의 오차를 보임으로써 이를 통한 새로운 실시간 스테레오 표적 감시추적 시스템의 구현 가능성을 제시하였다.

Development of Optical Sighting System for Moving Target Tracking

  • Jeung, Bo-Sun;Lim, Sung-Soo;Lee, Dong-Hee
    • Current Optics and Photonics
    • /
    • 제3권2호
    • /
    • pp.154-163
    • /
    • 2019
  • In this study, we developed an optical sighting system capable of shooting at a long-distance target by operating a digital gyro mirror composed of a gyro sensor and an FSM. The optical sighting system consists of a reticle part, a digital gyro mirror (FSM), a parallax correction lens, a reticle-ray reflection mirror, and a partial reflection window. In order to obtain the optimal volume and to calculate the leading angle range according to the driving angle of the FSM, a calculation program using Euler rotation angles and a three-dimensional reflection matrix was developed. With this program we have confirmed that the horizontal leading angle of the developed optical sighting system can be implemented under about ${\pm}8^{\circ}$ for the maximum horizontal driving angle (${\beta}={\pm}12.5^{\circ}$) of the current FSM. Also, if the ${\beta}$ horizontal driving angle of the FSM is under about ${\pm}15.5^{\circ}$, it can be confirmed that the horizontal direction leading angle can be under ${\pm}10.0^{\circ}$. If diagonal leading angles are allowed, we confirmed that we can achieve a diagonal leading angle of ${\pm}10.0^{\circ}$ with a vertical driving angle ${\alpha}$ of ${\pm}7.1^{\circ}$ and horizontal driving angle ${\beta}$ of ${\pm}12.5^{\circ}$.

밀리미터파(W 밴드) 탐색기용 FMCW SAR 영상의 2차원 엔트로피 최소 자동 초점 기법 (Two-Dimensional Entropy Minimizing Autofocusing of Millimeter-Wave (W-Band) FMCW SAR)

  • 박재현;전주환;이혁중;송성찬
    • 한국전자파학회논문지
    • /
    • 제29권4호
    • /
    • pp.316-319
    • /
    • 2018
  • 전방 이동지상 표적 탐지를 위해 미사일은 FMCW 레이다를 통해 획득한 SAR 영상을 활용할 수 있다. 하지만 미사일 이동 과정에서 난기류 또는 비행경로 상태에 따른 요동 오차로 인해 SAR 영상의 품질이 떨어지게 된다. 본 논문에서는 이러한 전방을 바라보는 SAR 영상의 요동 오차를 보상하기 위한 엔트로피 최소 자동초점기법을 제안한다. 특히, 전방을 바라보는 레이다 특성 상, 요동 오차는 2차원의 형태(방위각 및 시간 축)로 SAR 영상에 영향을 미치며, 이를 보상하기 위해 2차원 자동초점기법을 제시한다.

2차원 모델을 이용한 도어 개폐력 해석 (Analysis of Door Effort using 2D Model)

  • 김창원;강성종
    • 한국자동차공학회논문집
    • /
    • 제11권3호
    • /
    • pp.131-137
    • /
    • 2003
  • Proper door effort, required force to open or close a vehicle door, is an essential door design factor for the safety of passengers and pedestrians. Section shape of the door checker arm is the most influential design parameter for achieving a door effort design target. In this research. an analysis procedure to predict door effort using a simplified plane strain finite element model wes investigated for two passenger cars, for which mechanism of checker systems were: different. The variation of checker arm force to be required during moving on arm in opening and closing direction was estimated through analysis, and the result was transformed to the door effort with respect to door opening angle by considering door characteristics. Also, the self·closing force due to door weight was theoretically calculated and added to the door effort from checker arm force. Finally the estimated results of door effort were compared with test results.

Plasma Uniformity Analysis of Inductively Coupled Plasma Assisted Magnetron Sputtering by a 2D Voltage Probe Array

  • Joo, Junghoon
    • Applied Science and Convergence Technology
    • /
    • 제23권4호
    • /
    • pp.161-168
    • /
    • 2014
  • A real-time monitoring of immersed antenna type inductively coupled plasma (ICP) was done with a homemade 2 dimensional voltage probe array to check the uniformity of the plasma. Measured voltage values with a high impedance voltmeter are close to the floating potential of the plasma. As the substrate carrier was moving into a magnetron sputtering plasma diffusive from a $125mm{\times}625mm$ size cathode, measured results showed reliably separation of plasma into the upper and lower empty space over the carrier. Infra red thermal imaging camera was used to observe the cross corner effect in situ without eroding a target to the end of the usage. 3 dimensional particle trace model was used to analyze the magnetron discharge's behavior.

팬톰을 이용한 전산화 단층촬영방법에 따른 재현성에 대한 고찰 (A Study for Reappearance Acording to the Scan Type, the CT Scanning by a Moving Phantom)

  • 최재혁;정도형;최계숙;장요종;김재원;이희석
    • 대한방사선치료학회지
    • /
    • 제19권2호
    • /
    • pp.123-129
    • /
    • 2007
  • 목 적: 전산화 단층촬영방법(Computed Tomography, CT)에 따라 고식적(Axial), 나선식(Helical), 연속(Cine) 주사방법으로 획득되어진 영상은 주사방법이 다르므로 각각의 재현되는 이미지 상에서 차이가 존재한다. 각각의 전산화 단층촬영 주사방법(scan type)이 움직임을 얼마나 정확히 묘사하는지 알아보고자 구동 팬톰을 이용하여 재현성에 대해 고찰해 보고자 한다. 대상 및 방법: 상 하 방향, 위 아래 방향 움직임을 재현하기 위해 자체 제작한 구동 팬톰과 호흡동조 구동 motor를 이용한다. 구동 motor 위에 표지자를 올려놓고 전산화 단층촬영 시 움직임을 구별하기 위해 표지자에 위치 표시를 위한 방사선 비투과성 물질(Localizer)을 부착한다. 자체 제작한 구동 팬톰을 이용하여 위 아래 움직임은 1.3 cm (16회/1분당)으로 고정 시키고, 호흡동조 구동 motor을 이용하여 상 하 움직임은 0.2 cm (8 rot/1분당)으로 고정 한다. 각각의 움직임을 고정 시키고 난 후, 전산화 단층 촬영 방법에 따라 고식적(Axial), 나선식(Helical), 연속(Cine) 주사방법으로 촬영한다. RPT 장비를 이용하여 움직임을 나타내는 표지자에 부착한 방사선 비투과성 물질과 볼륨 재현성이 정확한지 비교, 분석 한다. 결 과: 표지자의 전체 체적은 88.2 $cm^3$로 위 아래 방향 3 cm, 상 하 방향 0.3 cm 이동을 고려했을 때는 전체 체적이 184.3 $cm^3$이었다. 각각의 전산화 단층촬영방법에 따른 전체 체적은 고식적 주사방법에서는 135 $cm^3$, 나선식 주사방법에서는 164.9 $cm^3$, 연속 주사방법에서는 181.7 $cm^3$였다. 움직임에 대한 재현성을 나타내는 데 있어 연속 주사방법에서 가장 근접하게 표지자를 묘출하였다. 또한, 표지자에 부착한 방사선 비투과성 물질의 재현성에서도 연속 주사방법에서 가장 근접하게 나타내었다. 결 론: 전산화 단층촬영방법에 따른 고식적, 나선식, 연속 주사방법은 움직임에 영향을 많이 받는 장기를 촬영할 때, 움직임에 따른 정확한 장기 묘사 및 종양 조직의 움직임을 재현해야 한다. 본 실험에서 사용한 구동 팬톰을 이용한 표지자를 재현하는데 있어 전산화 단층촬영 시 연속 주사방법에서 촬영 할 때 가장 재현성이 높았다. 하지만, 임상 적용 시 환자의 호흡이나 움직임이 팬톰처럼 일정하지 않기 때문에 이를 위한 환자 교육 및 호흡을 일정하게 해줄 수 있는 장치의 사용 및 개발이 필요하며, 각각의 전산화 단층촬영방법에 대한 피폭선량에 대해서도 고려해야 할 것이라 사료 된다.

  • PDF

폐암 SBRT에서 호흡동조 VMAT의 정확성 분석을 위한 새로운 4D 팬텀 모델 개발 (Development of New 4D Phantom Model in Respiratory Gated Volumetric Modulated Arc Therapy for Lung SBRT)

  • 윤경준;곽정원;조병철;송시열;이상욱;안승도;남상희
    • 한국의학물리학회지:의학물리
    • /
    • 제25권2호
    • /
    • pp.100-109
    • /
    • 2014
  • 정위신체방사선치료(SBRT)에서 환자의 호흡에 대한 정확한 치료위치의 확보는 필수적으로 고려되어야 하며 그 정확성에 관련하여 많은 연구들이 진행되어왔다. 본 연구에서는 실제 호흡에 의한 움직임과 실제 환자 폐의 형태를 고려한 팬텀실험으로 실제 치료에서 일어나는 임상적 상황을 모사함으로 호흡 동조 부피적조절회전 방사선치료(Volumeric Modulated Arc Therapy, VMAT) 기법을 이용한 폐부 SBRT의 정확성을 분석하는 방법을 제시하고자 하였다. SBRT을 받은 폐암 환자의 CT 영상을 기반으로 3D 프린터를 이용하여 치료부위와 유사하게 폐 팬텀을 제작하였고 환자 호흡과 동일하게 움직임을 재현할 수 있도록 $QUASAR^{TM}$ 호흡 동조 구동 팬텀(Modus Medical Devices, London, Canada)에 장착하여 호흡동조 VMAT에서의 2차원 선량 분포를 평가할 수 있는 시스템을 구축하였다. 폐 팬텀은 종양부위를 중심으로 2등분하여 EBT3 필름을 삽입하고 선량분포를 측정할 수 있도록 제작되었다. 비균질 조건에서의 선량계산의 정확성을 확인하기 위하여 균질한 플라스틱 팬텀과 제작된 비균질 폐 팬텀에서 Analytical Anisotropic Algorithm (AAA)와 AcurosXB (AXB) 두가지 알고리즘으로 선량계산을 하여 비교, 분석하였다. 움직임에 대한 치료의 정확성을 평가하기 위하여 호흡동조와 비 호흡동조의 경우, 그리고 움직임이 없는 조건에서 선량분포를 취득하여 치료계획 선량에 대한 감마지표를 분석하였다. 치료부위 GTV에서의 CT number는 실제 환자의 경우 78 HU를 나타내었고 모사된 폐 팬텀의 경우 92 HU를 나타내었다. 팬텀 내 폐 조직부분은 3D프린터로 적층하는 과정에서 격자구조의 형태를 이용하여 구현하였다. 측정된 필름선량은 AAA 알고리즘을 이용한 치료계획 선량에 대하여 움직이는 팬텀에서 호흡동조의 유무에 따라 3%/3 mm 감마지표 조건하에서 각각 88%와 78%의 감마합격률을 나타내었으며, 움직임이 없는 경우 95% 이상의 감마합격률을 보였다. AXB 알고리즘을 적용하였을 경우에는 모든 경우에서 98% 이상의 합격률을 나타내었다. 균질한 플라스틱 팬텀에 대하여 측정하였을 때 두가지 선량계산 알고리즘을 포함한 모든 조건에서 99% 이상의 감마합격률을 나타내었다. 선택된 환자의 호흡 진폭이 비교적 작고 inhale보다는 exhale에 더 오래 머무르는 호흡패턴 때문에 3%/3 mm 감마 기준에서는 호흡에 따른 차이가 거의 나타나지 않은 것으로 이해되었다. 선량계산의 정확성에서는 AAA 알고리즘을 적용하였을 때보다 AXB 알고리즘을 적용하였을 때가 균질과 비균질 환경에서의 선량 분포에 따른 감마 합격률의 차이가 적게 나타남을 확인 할 수 있었다. 본 논문에서는 환자와 유사하게 제작된 폐 팬텀에 실제 환자 호흡 패턴을 연동함으로 새로운 4D 치료선량 분포 검증 방법을 제시하였고 보다 사실적인 선량분포를 반영한 개별 환자 치료의 정확성 검증이 가능할 것으로 평가되었다.